Page 181

Chapter 4, Using the Terminal Emulation Menus

S TxRate The data rate (in Mb/s) of the last message transmitted by the Lucent radio. The default TXRate of 2 Mb/s and will be displayed when the terminal starts up and has not transmitted a frame yet. High speed Lucent radios are capable of data rates of 1 Mb/s, 2 Mb/s, 5.5 Mb/s, and 11 Mb/s. The TxRate 5.5 Mb/s data rate is displayed as 6 Mb/s. This occurs because the Lucent radio reports an integer value for current transmission data rate, so the data rate of 5.5 Mb/s is rounded up to 6 Mb/s. Radio Test PRI: v4.0 SEC: v4.52 RFLINK: Excellent SNR: 99dBm SSID: xxxxxxx B SSID: xxxxxxxxxxxx TxRate:xMb/s std

Primary version of Lucent driver Secondary version of driver RF link quality Signal-to-Noise ratio Network name in use MAC address of access point Data rate

2) RS232 Test (6400, 5055 DOS, 59XX, 17XX, 11XX) Tests the data communication port on the terminal, requiring a special loop-back connector that links the following input and output pins on the data connector: S TX output to the RX input S DTR output to the DSR input S CTS output to the RTS input To run the test, select 2) RS232 Test, attach the loop-back connector to the port connector on the terminal, then press [Enter]. The display changes to the second RS232 Test menu shown below. The condition of each line-pair displays as passing or failing the test. If any test fails, return the terminal for service.

RS232 Test Attach RS232 Loopback Connector Press Enter

RS232 Test RTS-CTS: PASS DTR–DSR: PASS TX-RX: PASS Any Key To Stop

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

157

Page 182

Chapter 4, Using the Terminal Emulation Menus

3) Display Test (6400, 5055 DOS, 59XX, 17XX, 11XX) 3) Display Test tests the operation of and activates each element in the terminal LCD panel. If a line appears broken, or there are gaps in the display, replace the LCD panel. 1 From the Display Test menu, press [Enter] to start the test. The display screen is painted with a series of vertical lines. Visually inspect the lines. All lines should appear clear and complete (no broken segments). 2 Press [Enter] to move to a screen drawn with horizontal lines. Visually inspect the lines using the same criteria. 3 Press [Enter] to move to the final screen. Visually inspect the painted black lines which should be uniformly black for monochrome displays and uniformly white for color displays. 4 Press [Enter] to return to the 1) Peripherals menu.

4) Keyboard Test (6400, 5055 DOS, 59XX, 17XX, 11XX) Tests each key on the terminal keypad or 5055 DOS external keyboard. Press each key, except the [Enter] key, and a character corresponding to the pressed key should appear on the display. Keyboard Test Press A Key ENTER To Exit Key = ’A’

5) Scanner Test This option tests the operation of an attached bar code scanner. From this menu, scan an enabled bar code. The bar code and the bar code length should appear on the display to pass. Press any key to exit. Scanner Test Scan Code> Length>

158

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

Page 183

Chapter 4, Using the Terminal Emulation Menus

2) Converters (59XX) Use this option to test the analog-to-digital (A to D) and the digital-toanalog (D to A) converters. The RSSI Test (not available on all radios) offers a choice of graphics displays of the received radio signals. Press any key to exit. Converters 1) A to D 2) D to A 3)

3) Memory View (6400, 5055 DOS, 17XX, 11XX) This menu is reserved for engineering test and evaluation. Press [F1] to exit out of this test, [F2] to view the heap, [F3] to view the far heap, or [F4] to do a memory dump. Memory View F1 - Exit F2 - Heap F3 - Far Heap F4 - Memory Dump Address: xxxxxx

4) Packet Driver (6400, 5055 DOS, 59XX, 17XX, 11XX) 4) Packet Driver tests accuracy of data transmissions to and from the terminal. Packet Driver 1) 2) 3) Packet Stats 4) Histogram 5) 6)

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

3) Packet Stats is for 6400, 5055 DOS, 59XX, 17XX, 11XX

159

Page 184

Chapter 4, Using the Terminal Emulation Menus

3) Packet Stats (Statistics) (6400, 5055 DOS, 59XX, 17XX, 11XX) Shows the number of packets sent and received, number of errors, and number of packets dropped. Receive Statistics Pkt xxx Chr xxx Err xxx Lost xxx

Transmit Statistics Pkt xxx Chr xxx Err xxx * See Text ’Histogram Options’ Transaction Statistics Qty xxx Sec xxx Qty/Min xxx Ops xxx

RTC Statistics

160

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

Page 185

Chapter 4, Using the Terminal Emulation Menus

4) Histogram An Intermec engineer may ask you to access this menu if your terminal has problems. From this menu you can provide the Intermec system engineer with vital information about your unit. The actual menus are not shown in this manual, however some of the general terminology is shown below. Several of the menu options, such as “Clear. . ., ” are password-protected and are only accessible if the engineer provides you with the correct password. An Intermec system engineer will work with you on these selections. Terminology you might see: S avg tx time

S send retries

S avg trans time

S rcv retries

S ptt (push-to-talk) count

S reset count

S addrs on list

S interval time

S poll no data

S time bucket #

Histogram 1) Start 2) Stop 3) View

5) Numbers (blank for 5055 .NET, 700 Series, CK30, CV60) 5) Numbers checks the operation of the terminal microprocessor. During the test, the terminal display is filled with hexadecimal numbers that move across the screen horizontally and scroll vertically. Character movement indicates that the processor is still running. To stop the test, press any key. This test is helpful in detecting lockups during severe operating conditions.

6) Timed Numbers (blank for 5055 .NET, 700 Series, CK30, CV60) 6) Timed Numbers does the same thing as 5) Numbers except that it keeps track of the time in seconds that it took to run the test. The test terminates when a key is pressed or when 65,536 numbers are displayed.

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

161

Page 186

Chapter 4, Using the Terminal Emulation Menus

5) Version Info (Information) 5) Version Info shows the name, version, and release date of the program you are using, the version of the radio driver, and the MAC address of the 6400, 5055 DOS, or 11XX Terminal. See Chapter 1, “Getting Started,” for TE program names.

MLID Name and MLID ver are for 6400, 5055 DOS

Version Info Firmware <TE Program Name> Version <number> Date <ddmmyy> MLID Name ZZZZZZ MLID ver xx.xx (mac address)

6) Exit Menus Note: If direct connect is used, the terminal may reboot upon exiting the TE configuration menu. Use 6) Exit Menus to exit the TE configuration menus. If you changed any parameter settings, the terminal displays the following when you exit the menus. Save Parms Enter ’Y’ to save parms

If you press [Y] (“yes”), you are prompted for a password. “cr52401” is the default password. Save Parms Enter Password > .......

162

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

Page 187

Chapter 4, Using the Terminal Emulation Menus

After you enter the correct password, your settings are saved to Flash, and the terminal may reboot. (Some changes automatically reboot the terminal.) If you press a key other than [Y], you exit the menus and the new settings are not saved. In this case, the new settings are lost when you reboot your terminal. When you exit the TE configuration menus, the following information appears: <TE program name> <version> Session: <number> Host: <data stream>

7) More (Main Menu 2) Select 7) More to open the Main Menu 2 screen. Main Menu 2 1) Keyboard Opts 2) Save Parms 3) Cloning Opts 4) Session Menu

3) Cloning Opts is for 59XX, 17XX, 11XX 4) Session Menu is for 2415 (WTP), 2425 (WTP), 2435A (WTP), 2455 (WTP), 2475 (WTP), 248X (WTP), 6400, 5020 (TCP/IP), 5055 DOS, 5055 .NET, 17XX, 11XX, 700 Series, CK30, CV60

1) Keyboard Opts Use 1) Keyboard Opts > 1) Type-Ahead to key in information when the terminal cannot immediately send data to the host computer. 1) Type-Ahead enters information when the terminal cannot immediately send data to the host. Keyboard Opts 1) Type - Ahead

This stores keystrokes after the Input Inhibited annunciator (below) appears on the status line, and then saves them for the next input field. Type-ahead is enabled by default.

X

Input Inhibited annunciator

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

163

Page 188

Chapter 4, Using the Terminal Emulation Menus

2) Save Parms (Parameters) Use 2) Save Parms to retain the changes made to TE configuration settings. When saved, changes become the default settings for the terminal. Note: Use this option sparingly. Each time it is used, additional memory space is occupied because previously saved changes are not erased. The memory cannot be recovered on 11XX, 17XX, and 59XX Terminals without reflashing. Ensure that the parameters are correct before choosing 2) Save Parms. When selected, you are prompted to enter a seven-character password. The default password is CR52401; which can be altered with a custom configuration to be a string of 1 to 10 characters long. After you enter the correct password, your changes are written to Flash. If an error is made or the incorrect password is entered, the terminal will return to 2) Save Parms screen without saving your entries. Save Parms

Save Parms

Enter Password: > . . . . . . .

Working Please Wait ........

3) Cloning Opts (59XX, 17XX, 11XX) Note: 3) Cloning Opts is disabled for 59XX Terminals. These options transfer the application program or parameter settings from one terminal to another. All three choices are password-protected, with CR52401 as the default password. To perform this function you need a cloning cable and both terminals set for cloning. Cloning Opts 1) Clone Prgms 2) Clone Parms 3) Receive Parms

1 Connect the two terminals together using the cloning cable. Use cable P/N: 216-911-001, with radio terminals containing 12-volt Flash (see illustration on page 165) for connecting with the NC1100 Power Supply and Charger (see illustration on page 166). 2 Plug the NC1100 Power Supply and Charger into an ac outlet. Use cable P/N: 216-909-001, with radio terminals containing 5-volt Flash. You may use the 12-volt Flash cable, but this is optional.

164

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

Page 189

Chapter 4, Using the Terminal Emulation Menus

3 Turn on the source terminal from which to copy the application. 4 Press 3) Cloning Opts, then 1) Clone Prgms. 5 Key in the password. 6 Hold down the [I] key while turning on the terminal receiving the program. The application program will copy into the receiving terminal. To Source Terminal

To NC1100 Charger

To Receiving Terminal

12-Volt Cable (P/N: 216-911-001)

5-Volt Cable (P/N: 216-909-001)

To Source Terminal

To Receiving Terminal

This illustrations shows the FLASH cloning cable connections as they pertain to step 1 on the previous page.

To clone parameters from one terminal to another, first ensure the desired parameters are already set in the terminal you wish to transfer from. Then: 1 Connect the terminals together using the cloning cable. Data Terminals with 12-volt FLASH use P/N: 216-911-001. Data Terminals with 5-volt FLASH use P/N: 216-909-001. 2 With both terminals turned ON, press 3) Cloning Opts on both terminals. 3 On the source terminal (the terminal with the parameters from which to copy), press 2) Clone Parms.

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

165

Page 190

Chapter 4, Using the Terminal Emulation Menus

4 On the receiving terminal, press 3) Receive Parms. If using the cable that requires the NC1100 Power Supply and Charger, make sure it is connected to the NC1100 Power Supply and Charger.

Follow the alignment from the NC1100 power supply to the cloning cable connection. This illustration pertains to step 1 on page 164.

4) Session Menu (2415, 2425, 2435A, 2455, 2475, and 248X with WTP, 6400, 5020, 5055 DOS, 5055 .NET, 59XX, 17XX, 11XX, 700 Series, CK30, CV60) 4) Session Menu defines different host communication sessions and designates a “hot key” that allows switching quickly between the different sessions.

1) Switch Use this option to change the current session. The current (or intended) session must be identified (or designated) before setting Parameters.

2) Set Hot Key (Available on units that support session-switching) Displays the current hot key. Use the up and down keys to view the available choices. Press [Enter] to designate a key for the hot key.

3) Copy Setup (Password-protected) This copies parameters from the background session to the current session. Session Menu 1) Switch 2) Set Hot Key 3) Copy Setup

Select Session Use Cursor Up And Down Keys To Adjust

[1]

Session: x Host: xxxx <Datastream>.....xxx

166

[2]

Set Hot Key Use Cursor Up And Down Keys To Adjust < xx >

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide