Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 20 of 47

TE 2000 VT/ANSI Terminal Emulation Programmer's Guide: Chapter 4: Using the Terminal Emulation Menus, pages 171 to 180

Pages 171 to 180 of 416, from TE 2000 VT/ANSI Terminal Emulation Programmer's Guide

The original document is the PDF (3.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 2435

Page 171

Chapter 4, Using the Terminal Emulation Menus

59XX Terminal Screen Sizes Choices for the 59XX Terminal includes the following. Only one option can be selected at a time. (Default is 12 x 40) S 8 rows, with 40, 60, or 80 columns per row S 10 rows, with 40, 60, or 80 columns per row S 12 rows, with 40, 60, or 80 columns per row S 16 rows, with 40, 60, or 80 columns per row S 21 rows, with 80 columns per row S 25 rows, with 80 columns per row Screen Size 40

60

80

8

Off

Off

Off

10

Off

Off

Off

12

On

Off

Off

16

Off

Off

Off

21

Off

25

Off

17XX Terminal Screen Sizes Choices for the 17XX Terminal include the following. Only one option can be selected at a time. (Default is 8 x 22) S 4 lines, with 12, 17, 22, or 26 characters per line S 6 lines, with 12, 17, 22, or 26 characters per line S 8 lines, with 12, 17, 22, or 26 characters per line S 10 lines, with 12, 17, 22, or 26 characters per line S 12 lines, with 12, 17, 22, or 26 characters per line S 16 lines, with 12, 17, 22, 26, or 31 characters per line S 21 lines, with 12, 17, 22, or 26 characters per line Screen Size

4 6 8 10 12 16 21

12

17

22

26

Off Off Off Off Off Off off

Off Off Off Off Off Off off

Off Off On Off Off Off off off off off off off off off

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

31 off

147

Page 172

Chapter 4, Using the Terminal Emulation Menus

11XX Terminal Screen Sizes Choices for the 11XX Terminal include the following. Only one option can be selected at a time. (Default is 9 x 16) S 4 rows, with 12 or 16 characters per row S 6 rows, with 12 or 16 characters per row S 8 rows, with 12 or 16 characters per row S 9 rows, with 12 or 16 characters per row

12 4 6 8 9

Select Size 16 Off Off Off Off

Off Off Off On

700 Series Computer Screen Sizes Choices for the 700 Series Computer include the following. Only one option can be selected at a time. (Default is 10 x 20) S 8 rows, with 10, 13, 16, 20, 23, 26, or 30 characters per row S 10 rows, with 10, 13, 16, 20, 23, 26, or 30 characters per row S 12 rows, with 10, 13, 16, 20, 23, 26, or 30 characters per row S 14 rows, with 10, 13, 16, 20, 23, 26, or 30 characters per row S 16 rows, with 10, 13, 16, 20, 23, 26, or 30 characters per row Screen Size

8 10 12 14 16

148

10

13

16

20

23

26

30

Off Off Off Off Off

Off Off Off Off off

Off Off Off Off off off On Off Off Off

Off Off Off off Off

Off Off Off Off Off

Off Off Off Off Off

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

Page 173

Chapter 4, Using the Terminal Emulation Menus

CK30 PC Screen Sizes Choices for the CK30 Data Collection PC include the following. Only one option can be selected at a time. (Default is 10 x 20) S 8 rows, with 10, 16, 20, 26, or 30 characters per row S 10 rows, with 10, 16, 20, 26, or 30 characters per row S 12 rows, with 10, 16, 20, 26, or 30 characters per row S 14 rows, with 10, 16, 20, 26, or 30 characters per row S 16 rows, with 10, 16, 20, 26, or 30 characters per row Screen Size

8 10 12 14 16

10

16

20

26

30

Off Off Off Off Off

Off Off Off Off off

Off On Off Off off off Off Off Off Off

Off Off Off off Off

3) Screen Mode 3) Screen Mode selects the cursor position and movement as you scroll through data in the display buffer. This buffer stores data in a standard CRT format (as sent from the host computer). Since the terminal display is smaller than a CRT, these 3) Screen Mode options optimize your view of information (data) on the display. Default is 2) Corner Mode. Use arrow keys to scroll (or “move”) the screen’s view port on the display. Screen Mode 1) Center Cursor 2) Corner Mode 3) Page Mode 4) Lazy Mode 5) Locked Mode 6) Define Origin

1) Center Cursor In this mode, the cursor begins near the center of the display and attempts to remain there as you scroll through the data. Upon reaching an outside boundary of the full CRT screen, the display stops advancing while the cursor moves beyond the center of the screen. When the cursor reaches the boundary of the CRT screen, an error tone sounds, such as a “beep.” The cursor does not wrap to the next line in the display.

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

149

Page 174

Chapter 4, Using the Terminal Emulation Menus

2) Corner Mode Starts the display at the upper-left corner of the full CRT screen and keeps the cursor in the lower-right corner of the display. As you scroll, the cursor remains there as data advances in the scrolled direction (up, down, right, or left) until an outside boundary of the full CRT screen is reached. Then the screen stops moving in relation to the display and the cursor moves in the scrolled direction (the cursor no longer remains in the corner of the display). When the cursor reaches the CRT screen boundary it stops moving. The cursor does not wrap to the next line in the display. An error tone sounds if you try to move the cursor beyond the boundary. This option is recommended when your application uses only the upperleft corner of the full CRT screen.

3) Page Mode Divides the full CRT screen into predefined “pages,” and starts the terminal display on page 1. The cursor first appears in the upper-right corner of the display. As you scroll, only the cursor moves (the data on the screen does not appear to move). When you scroll off the edge of the displayed page, the display snaps to the next (or previous) page. Upon reaching the boundary of the CRT screen, the cursor stops moving and an error tone sounds each time you attempt to move beyond the boundary. Some “pages” in 3) Page Mode overlap each other (the same information is shown on both pages). This overlap occurs because the 24-row by 80-column CRT screen cannot be divided equally.

4) Lazy Mode Starts the cursor in the upper left corner of the terminal display. The cursor moves across the display in the scrolled direction. When the cursor goes beyond the edge of the display, the data begins to move in the opposite direction that the cursor is moving in and the cursor remains at the edge of the display. When you reach an outside boundary of the full CRT display, an error tone sounds each time you try to move beyond the boundary.

5) Locked Mode When this is selected the screen view is locked to the upper left-hand corner of the display. Any characters selected outside of the display window size are written to the screen but are not visible. The windowing keys do not move the visible window. Note: In 5250 emulation, the err_row is mapped to the last row of the screen size selected.

150

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

Page 175

Chapter 4, Using the Terminal Emulation Menus

6) Define Origin Use this option to specify the “X,Y” origin of the terminal display. Enter a number from the range of 0–79 for the “X” origin and a number from the range of 0–23 for the “Y” origin. Default is 0 for both “X” and “Y” origins . Define Origin 1) X Origin 2) Y Origin

Y Origin

X Origin 0

[1]

[2]

Enter number from 0–79

0 Enter number from 0–23

4) Annunciators (Blank for 17XX, 11XX) 4) Annunciators selects and changes the location of the annunciators on the display screen. Press the up or down arrows to position the annunciators around each of the four display corners, once as a line and once as a box. You can also select “Stealth Mode” which displays the annunciators only when you make a change and then hides it when you press a key. Default is “Stealth Mode.” Annunciators Use cursor up and down keys to Adjust.

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

151

Page 176

Chapter 4, Using the Terminal Emulation Menus

5) Backlight (59XX, 17XX) This adjusts the intensity (brightness) of the display backlight. The intensity can be set from 0 (off) to 15 (fully on). Keep in mind that the backlight uses considerable battery power. To conserve battery power, keep the intensity and duration of the backlight as low as possible. Use the up and down arrow keys to adjust the intensity of the backlight. Press the up arrow key to increase the intensity, the down arrow key to decrease. Press [Enter] when finished to return to the LCD Parms screen. BLight Intensity Use cursor up and down keys to Adjust. xx

6) Key Uppercase When enabled, 6) Key Uppercase causes the alphabetic keys (A–Z) to display as uppercase characters regardless of the shift or caps lock mode settings.

7) Scroll Window 7) Scroll Window defines the cursor movement, just how far it moves with each press of the arrow keys. Default is 1) Tab Size.

1) Tab Size Moves the cursor by the amount configured for 3) Define Width and 4) Define Height.

2) Screen Size Causes the cursor to move by the virtual screen size selected in 2) LCD Parms under the Main Menu.

3) Define Width and 4) Define Height These options customize the x-axis and y-axis (up and down) movement of the cursor when 1) Tab Size is selected. Default is 8. Scroll Window 1) Tab Size 2) Screen size 3) Define Width 4) Define Height

152

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

Page 177

Chapter 4, Using the Terminal Emulation Menus

3) Beeper Setup The 3) Beeper Setup menus adjust the beeper tones for key clicks (presses) and error conditions. For 17XX Terminals, 3) Beeper Select directs the audio output to the internal buzzer or to a headset. Beeper Setup 1) Key Click 2) Error Tone 3) Beeper select

1) Key Click is for 6400, 5055 DOS, 59XX, 17XX, 11XX 3) Beeper Select is for 6400, 5055 DOS, 17XX, 11XX

1) Key Click (6400, 5055 DOS, 59XX, 17XX, 11XX) Use 1) Key Click to adjust the frequency and length (duration) of the sound made when you press a key. To adjust the key click tone, press the appropriate Key Click option, then press the up or down arrow keys to make the desired adjustment. Each key press is accompanied by a tone at the new frequency or length. Press [Enter] to confirm the selection and return to the previous 1) Key Click screen.

1) Volume (59XX) Press [1] , then the up and down arrow keys to adjust the length in steps from 0 to 32.

2) Length Press [2] , then the up and down arrow keys to adjust the length in steps from 0 to 10.

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

153

Page 178

Chapter 4, Using the Terminal Emulation Menus

3) Frequency (6400, 17XX, 11XX) Press [3], then the up and down arrow keys to adjust the tone frequency in steps from 0 to 32.

Key Click 1) Volume 2) Length 3) Frequency

Volume Use Cursor Up And Down Keys To Adjust

[1]

1) Volume is for 59XX 3) Frequency is for 6400, 17XX, 11XX

[2]

Key Click> xx

Frequency Use Cursor Up And Down Keys To Adjust

Length Use Cursor Up And Down Keys To Adjust Key Click> xx

[3]

Key Click> xx

2) Error Tone 2) Error Tone adjusts the length and frequency of the tone made when an error occurs (for example, pressing an invalid key). The 2) Error Tone adjustments, and the procedures for making them are identical to the 1) Key Click adjustments. Press 2) Length to set the length. The range is 1 through 10, which equates to a 500 to 5000 ms beep for all errors. Default error tone length is 3 (or 1500 ms). Error Tone 1) Volume 2) Length 3)

Volume Use Cursor Up And Down Keys To Adjust Error Tone> xx

154

[1]

1) Volume is for 59XX

[2]

Length Use Cursor Up And Down Keys To Adjust Error Tone> xx

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

Page 179

Chapter 4, Using the Terminal Emulation Menus

3) Beeper Select (6400, 5055 DOS, 17XX, 11XX) For 17XX, 11XX, both buzzers are not allowed to beep simultaneously when using a headset. If both options are enabled, the head set buzzer will beep first before the internal buzzer. If you are using the RS-232 port for communications, enable 1) Beep Internal and disable 2) Beep Head Set.

1) Beep Internal Press [1] to direct the audio to the internal beeper. Default is enabled.

2) Beep Head Set (11XX) Press [2] to direct sound to the headset. Beeper Setup 1) Beep Internal 2) Beep Head Set

2) Beep Head Set is for 17XX, 11XX

4) Tests Intermec Systems Engineers use the 4) Tests menus to verify terminal operation during environmental stress tests, peripherals, the display, RF communications, and memory. Tests 1) Peripherals 2) Converters 3) Memory View 4) Packet Driver 5) Numbers 6) Timed Numbers

2) Converters is for 59XX 3) Memory View and 4) Packet Driver are for 6400, 5055 DOS, 59XX, 17XX, 11XX 5) Numbers and 6) Timed Numbers are blank for 5055 .NET, 700 Series, CK30, CV60

1) Peripherals 1) Peripherals tests terminal peripheral devices, such as radio, RS-232, display, keyboard, and scanner. Detailed descriptions of each peripheral test follows. Peripherals 1) Radio Test 2) RS232 Test 3) Display Test 4) Keyboard Test 5) Scanner Test

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide

1) Radio Test is for 6400, 5055 DOS 802.11 (Lucent) radios 2) RS232 Test, 3) Display Test, and 4) Keyboard Test are for 6400, 5055 DOS, 59XX, 17XX, 11XX

155

Page 180

Chapter 4, Using the Terminal Emulation Menus

1) Radio Test (802.11 (Lucent) Radios, 6400, 5055 DOS) Several factors influence the rate at which a frame is transmitted. First, the radio’s transmission rate is configured in the net.cfg file. The keyword Transmit_Rate in net.cfg holds a numeric value for the transmission rate. The transmission rate is also affected by the characteristics of the RF link. If the radio encounters problems sending a higher transmission rate because the RF link is weak, busy, or noisy, the radio may retry the transmission at a lower data rate. Thus, the TxRate reported may be lower than the configured transmission rate. Only the transmission rate of the most recent and successful transmission is reported. Transmit_Rate values and their respective supported transmission rates available in the high speed Lucent radios are as follows: 1 Fixed Low (1 Mb/s) 5 Fixed High (11 Mb/s) 2 Fixed Standard (2 Mb/s) 4 ARS Standard (2 Mb/s) 3 ARS High (11 Mb/s default) 4 ARS Medium (5.5 Mb/s) 4 Fixed Medium (5.5 Mb/s) S PRI The primary version of low-level radio firmware. S SEC The secondary version of the low-level radio firmware. S RFLINK A general description of the RF connection overall quality between Lucent radios in the terminal and radios in the Access Point. The Lucent radio grades the RF link on a scale from 0–92, representing the RF channel Signal-to-Noise Ratio. The RF link quality descriptions are assigned as: 0–23 “Adequate,” 24–47 “Good,” or 48–92 “Excellent.” S SNR (Signal-to-Noise Ratio) Calculated by dividing the RF signal level by the RF noise level. The result is a number that indicates the overall communications quality of the RF link and is expressed in dBm. S SSID (Service Set ID) A 32-character, alphanumeric string that identifies the service set, or infrastructure, with which the terminal is currently associated. The SSID is a user-configurable parameter and is configured by the keyword WaveLAN_Network_Name in the net.cfg file. Setting the keyword to ANY allows the station to associate with any service set. S B SSID (Basic Service Set ID) The 6-byte MAC address of the Lucent radio in the Access Point with which the station is associated. The Lucent radio in the terminal may associate with a non-Lucent (but 802.11-compliant) radio in an Access Point. Looking at the first three bytes of the MAC address (OUI) can help identify the Access Point radio’s manufacturer.

Example An OUI of “00601D” points to a Lucent radio, while “0020A6” indicates a Proxim radio.

156

TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide