The text of a manual · part 22 of 47
TE 2000 VT/ANSI Terminal Emulation Programmer's Guide: Chapter 4: Using the Terminal Emulation Menus, pages 191 to 196
Pages 191 to 196 of 416, from TE 2000 VT/ANSI Terminal Emulation Programmer's Guide
The original document is the PDF (3.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2435
Page 191
Chapter 4, Using the Terminal Emulation Menus
Restarting Terminal Emulation Note: The reset firmware bar code is not supported on the 5020, 5055 .NET, 59XX, 17XX, 11XX, 700 Series, CK30, or CV60 Terminals. Instead, do the cold-start function to exit the TE application and return to the Windows CE main menu. You need to restart your TE application if you are having problems or if you want to reconnect to the host with a new configuration. Restarting your TE application also clears the auto-login information, preventing another user from establishing a TE session using your login information. You can restart your TE application by either scanning the following Reset Firmware bar code or by using the 6) Cold Start option in the TE configuration Main Menu. Both methods reset all terminal firmware and the application and run the application in a new session. Reset Firmware
*/M.* *-.*
The terminal restarts your TE application using the configuration saved in CONFIG.DAT, or follow this procedure: 1 At the third initialization screen or anywhere in a TE session, access the Main Menu by pressing the appropriate key combination (see page 4).
COPR. 1991-2003 INTERMEC. ALL RIGHTS RESERVED V<version number> <release date>
TE 2000(TM)
<program name> <version> Host: <host name> <emulation type>
<program name> <version> <emulation type> Host: <host name>
For Version 7.26 or greater
TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide
167
Page 192
Chapter 4, Using the Terminal Emulation Menus
Note: If not connected to the DCS 300 or host, or have problems accessing the Main Menu, reset the terminal to go to the initialization screens. 2 Select 1) Setup Parms, then enter the “cr52401” password. Do not press Enter. 3 Select 6) Cold Start, press [Y] when prompted to restart, then start using the application or change the TE configuration. See the terminal’s user guide or manual for information on how to recover from a lock-up condition.
2415, 2425, 2435A, 2455, 2475, 248X Terminals The following instructions are specific for 2415, 2425, 2435A, 2455, 2475, and 248X Terminals. You can configure several options for VT/ANSI TE on your Trakker AntaresR Terminal, including: S UDP Plus or TCP/IP communications S VT/ANSI options S Main Menu password Note: You can also set the password for UDP Plus Terminals from the DCS 300. You can access the TE configuration menus when the initialization screens appear or once you establish a TE session. The TE initialization screens appear each time you reboot the terminal or restart your application. Note: Some parameters for 2415, 2425, 2435A, 2455, 2475, and 248X Terminals are available through the TRAKKER Antares 2400 Menu System. They are not reproduced in the TE configuration menus. See the terminal’s user manual for information about the menu system.
168
TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide
Page 193
Chapter 4, Using the Terminal Emulation Menus
6400 Computer The terminal emulation screens support terminals running Intermec Terminal Emulation or 6400 TCP/IP software. This describes the menus used to set operating and scanning parameters for the hand-held computer. Additional information can be found in the technical overview for your emulation program. Note: Ensure there is a fully-charged battery pack in the 6400 Computer before setting parameters.
Opening the Main Menu The Main Menu is the first screen displayed when you open the computer menus. All other menus are accessed from the Main Menu. To open the Main Menu, press the [Yellow] shift, then the [Blue] shift key. Briefly, these keys generally operate as: S [Blue] shift, for functions labeled by blue legends above the keys. S [Green] shift, for functions labeled by green legends above the keys. S [Yellow] shift, for functions labeled by yellow legends above the keys. S [Blue], then [Green] shift is CAPS LOCK. S [Blue], then [Yellow] shift is Alphabetic Lock (6400 Computer 41-key units). S [Yellow], then [Blue] shift is Terminal Emulation menus; your particular emulation software probably treat the keys for contrast control, backlighting and other functions differently.
To Exit Emulation Mode and Return to DOS Do a cold-restart to exit the current emulation program and return back to the DOS keyboard layout. Press [Y], press [Enter] several times to put you at the DOS C:\ prompt. To exit to the beginning of the current emulation, press and hold the [Blue] and [Yellow] shift keys, and both [ENT] keys to do the hard reset.
TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide
169
Page 194
Chapter 4, Using the Terminal Emulation Menus
5055 Data Collection PC If you are running terminal emulations and ever update the DOS load on the internal SanDisk IDE drive on the 5055 PC, be aware that when updating 50DS1000, avoid copying the CONFIG.SYS and AUTOEXEC.BAT files. The new versions of these two files may interfere with existing applications, such as Terminal Emulations. If affected, Terminal Emulations will automatically run on boot up. In all other situations, do copy the CONFIG.SYS and AUTOEXEC.BAT files. This contains information about the terminal emulations with keyboards supported for the 5055 Data Collection PC. The 5055 PC supports terminal emulations with rugged keyboards. FWP650H0 is DOS-based and is not compatible with Windows DOS prompts. An external PS/2-compatible keyboard is required for configuring and using terminal emulations. Terminal emulation font files are needed to generate the various character fonts. See the related terminal emulation programmer’s reference guide for additional information.
Programs Used to Create Terminal Emulation Menus The Terminal Emulation Menu Screens are provided to support terminals running Intermec Terminal Emulation software. This describes the menus that set operating and scanning parameters for the 5055 PC. Additional information can be found in the programmer’s guide or technical overview for your emulation program. When you power on the 5055 PC, the AUTOEXEC.BAT file executes the following programs, in sequential order, to create the terminal emulation menus. Listed are their descriptions. S LSL Creates the link layer for the protocol stack. S rl2pcm Includes the Proxim radio driver for the Proxim RangeLAN2 radio, or wvlan43 Includes the WaveLAN/IEEE radio driver for the 802.11b HR radio. S 6500ikps Installs multitasking, beeper, and key remapping TSRs. S wtppkt Includes the WTP Packet driver program if a WTP link accesses the host computer, or ethdrv and odipkt Includes the Ethernet and ODI Packer driver programs if a TCP/IP link and a controller are used to gain access to the host computer.
170
TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide
Page 195
Chapter 4, Using the Terminal Emulation Menus
S 65scn7b -c1 Activates the scanner driver. S 6500dbcs Intercepts INT10 and display characters on the display. S fwp650h0 Activates the terminal emulation program. Press <Alt>, then [M] on the external keyboard to access the setup menus. Note: On terminal emulation keyboards, use the yellow key in place of the <Alt> key. For example, to access the Setup Menus, press [Yellow], then [M].
Opening the Main Menu The Main Menu is the first screen displayed when you open the computer menus. All other menus are accessed from the Main Menu. To open the Main Menu, press the yellow shift, then the blue shift (MENU) key. Briefly, these keys generally operate as: S [Blue] shift, for functions labeled by blue legends above the keys. S [Green] shift, for functions labeled by green legends above the keys. S [Yellow] shift, for functions labeled by yellow legends above the keys. S [Blue], then [Green] shift is CAPS LOCK. S [Yellow], then [Blue] shift is Terminal Emulation menus; your particular emulation software probably treat the keys for contrast control, backlighting and other functions differently.
To Exit Emulation Mode and Return to DOS Do a cold-restart to exit the current emulation program and return back to the DOS keyboard layout. Press [Y], then press [Enter] several times to arrive at the DOS C:\ prompt. To exit to the beginning of the current emulation, press and hold the [Blue] and [Yellow] shift keys, and both [ENT] keys to do the hard reset.
TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide
171
Page 196
Chapter 4, Using the Terminal Emulation Menus
172
TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide