Page 149
Chapter 4, Using the Terminal Emulation Menus
WTP Stack Options Controller Type 1) 2) RTC/WTP 3)
[2] Host/Cntl 1) Radio Setup 2) Host/Cntl
[1]
For 802.11 Radios Only
[2]
Go to Host/Cntl on the next page
For Non 802.11 Radios
Radio Setup Network Name
Radio Setup LAN xxxx Enter up to 34 characters for a name xx
ENTER
Radio Setup Radio Config#
Only if a “radio cfg“ file is present on the terminal.
ENTER (5055 -- continue to Host/Cntl setups)
Set Mode/Channel is for RM60 (902 MHz) radios
Set Mode/Channel Use Cursor Up and Down Keys To Adjust DS xxxx channel xx
Set Frequency Use Cursor Up and Down Keys To Adjust
Set Frequency is for Synthesized UHF radios xxxxxxxxx ENTER (continue to Host/Cntl setups)
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
125
Page 150
Chapter 4, Using the Terminal Emulation Menus
ENTER
Host/Cntl Settings Host/Cntl 1) CNTL A 2) CNTL B 3) CNTL C ENTER
DONE
ENTER
Controller (x) Enter Unit Number xxx
ENTER Controller (x) (cust emulation) unit # xxx Host Name Enter up to 16 characters/Numbers for a name. ENTER Emulation (x) Enter Unit 1) Native 2) 3270 3) 5250 4) VT/ANSI
ENTER
Telnet (x) 1) Enabled 2) Disabled
ENTER
3) Direct Connect (6400, 5055) The first option if exercising TCP/IP stack is 1) Radio Setup. Once selected, enter your network name or LAN ID. If using a 902 MHz radio module, use the up and down arrows to pick the Direct Sequence (DS) and Channel configuration. If using a Synthesized UHF radio, select possible frequencies for your radio module from the list. The 2) Host/Cntl option changes the host setting to designate up to three host computers for each 6400 Computer or 5055 PC. Each host is assigned a separate priority level (1, 2, or 3). When powered on, the 6400 Computer or 5055 PC seeks host A. If host A is not available, then the unit seeks host B; if host B is unavailable, the unit then logs onto host C.
126
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
Page 151
Chapter 4, Using the Terminal Emulation Menus
When designating additional hosts for the 6400 Computer or 5055 PC, you must: S Tell the 6400 Computer or 5055 PC the host type of each host computer: (3270, 5250, or VT/ANSI). S Tell the 6400 Computer or 5055 PC the name of each host. Note: Selections in these menus apply only to the current session. Use 4) Session Menu to verify or change the current session. TCP/IP Stack Options Direct 1) Radio Setup 2) Host Setup
[1]
For 802.11 Radios Only
[2]
Host 1) Host A 2) Host B 3) Host C
For Non 802.11 Radios
Radio Setup Network Name
Radio Setup LAN
ENTER Host Name (x) Host emulation xxxx Enter up to 34 characters for a name xx
Host Name Enter up to 64 character/numbers for a name
ENTER
ENTER Radio Setup Radio Config#
Only if a “radio cfg“ file is present on the terminal.
Emulation (x) 1) 2) 3270 3) 5250 4) VT/ANSI
ENTER (5055 -- continue to Host/Cntl setup)
Set Mode/Channel is for RM60 (902 MHz) radios
Set Mode/Channel Use Cursor Up and Down Keys To Adjust DS xxxx channel xx
Set Frequency Use Cursor Up and Down Keys To Adjust
Set Frequency is for Synthesized UHF radios xxxxxxxxx
ENTER (continue to Host/Cntl setups)
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
127
Page 152
Chapter 4, Using the Terminal Emulation Menus
3) Direct Connect (2415, 2425, 2435A, 2455, 2475, 248X, 5020, 700 Series, CK30, CK31, CK60 with TE/IP) To set these options, select 3) Direct Connect, 2) Host Setup, then 1) Host A. Use the Emulation (A) option to tell the terminal the type of each host computer. Default is VT/ANSI. Note: You can also set the emulation type through the 2) Data Stream option on the 3) Protocol Opts menu. Controller Type 1) 2) 3) Direct Connect
[3] Direct Connect 1) 2) Host Setup
[2] Host 1) Host A 2) Host B 3) Host C
2) Host B and 3) Host C are for 5020, 700 Series, CK30, CK31, CV60
ENTER Host Name (x) Host emulation Unit # xxx Host Name Enter up to 64 character/numbers for a name
Unit # xxx is for 700 Series, CK30, CK31, CV60 and appears if RTC over TCP is enabled.
ENTER Port Number (x)
If you want to use a port other than 23, enter that port here. Range is 0–65535.
23
These two boxes are for 700 Series, CK30, CK31, CV60
ENTER Emulation<A, B, or C> 1) Native 2) 3270 3) 5250 4) VT/ANSI
128
Note: If the Native protocol is selected, RTC over TCP cannot be disabled.
Emulation<A, B, or C> 1) RTC over TCP ENTER
Emulation<A, B, or C> ENTER
Enter Unit Number: xxx
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
Page 153
Chapter 4, Using the Terminal Emulation Menus
2) Barcode Parms (2415, 2425, 2435A, 2455, 2475, 248X, 5020) The 2) Barcode Parms (parameters) menus designate whether you are using a bar code scanner and scan options. Barcode Parms 1) Code 39 Encoded 2) 3) Concatenate 4) RS232 Stream 5) Stream Scan 6) Scan All Flds
4) RS232 Stream is blank for 5020
1) Code 39 Encoded By default, 1) Code39 Encoded is disabled. When you enable this option, the key press sequences for Encoded Code 39 are used. For more information, see Appendix A, “Bar Code Scanning.”
3) Concatenate Each bar code read is added to the end of the previous bar code read until the 2415, 2425, 2435A, 2455, 2475, 248X, or 5020 Terminal meets a condition forcing transmission to the host. When this option is OFF, each bar code read is placed at the beginning of the current input field. After a bar code is placed in a field, any subsequent read replaces the first read. Note: If you access the TE configuration menus when 4) RS232 Stream is enabled, all RS-232 data received during this time is lost. Only the data arriving from the COM1 port on the hand-held terminal is received.
4) RS232 Stream (blank for 5020) If this option is enabled, the terminal watches the RS-232 port for activity in which the terminal reads in the RS-232 data and sends it to the host. This enables support for fixed-station scanners or scales that send only RS-232 data without having the host send an extended command to enable the RS-232 port. Default for 4) RS232 Stream is disabled. For information about setting scanner options when this is enabled, see Chapter 2, “Using Terminal Emulation Applications.”
5) Stream Scan If the scanned bar code is too big for the input field, the overflow information appears in the next field and continues until the entire bar code is entered. When this option is OFF, and the scanned bar code is too big for the input field, the overflow information is dropped.
6) Scan All Flds (Fields) When this option is selected, the scanner is enabled when the cursor is in an input field. When this option is OFF, the host computer must enable the scanner for each input field that requires scanned data. TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
129
Page 154
Chapter 4, Using the Terminal Emulation Menus
2) Barcode Parms (6400, 5055, 59XX, 17XX, 11XX, 700 Series, CK30, CK31, CV60) Selecting 2) Barcode Parms displays either the Scanner Type menu or the Scan Options menu, pending on your terminal: S For the 6400, 5055, 59XX, 17XX, 11XX Terminals, Selecting 2) Barcode Parms displays the Scanner Type menu. S For the 700 Series, CK30, CK31, CV60 Terminals, Selecting 2) Barcode Parms displays the Scan Options menu.
Scanner Type (6400, 5055, 59XX, 17XX, 11XX) Use the Scanner Type menu to designate the type of bar code scanner. To make a selection, press the numeric key corresponding to the desired option, then press [Enter] to access the Scan Options menu. Note: If 1) No Scanner is chosen, you can set the remaining scanner and bar code options. Then, if a scanner is used at a later time, you only designate the scanner type. Selected options are highlighted on the display. Press a key corresponding to that option to deselect a selected option. Scanner Type 1) No Scanner 2) Wand 3) Laser 4) Wand Emulate 5) Auto Detect
2) Wand, 4) Wand Emulate, and 5) Auto Detect are for 59XX, 17XX, 11XX
Scan Options Use the Scan Options menu to assign scan options, enable bar code symbologies to use (the terminal can only decode the enabled symbologies), and set options for each enabled bar code symbology, such as the bar code lengths. Press [Enter] to advance to other Scan Options menus. Scan Options 1) Redundancy 2) MOD 10 Check 3) Concatenate 4) BC Type Char 5) Stream Scan 6) Scan All Flds 7) More
1) Redundancy is for 6400, 59XX, 17XX, 11XX 3) Concatenate is for 6400, 5055, 700 Series, CK30, CK31, CV60 4) BC Type Char is for 6400, 59XX, 17XX, 11XX, 700 Series, CK30, CK31, CV60
1) Redundancy (6400, 59XX, 17XX, 11XX) This option requires two identical scans of a bar code, one right after another, before the terminal accepts the scan as valid.
130
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
Page 155
Chapter 4, Using the Terminal Emulation Menus
2) Mod 10 Check When you select this option, a check digit is added at the end of the bar code after a good read for transmission to the host. The host can then validate the transmitted data using the check. This feature is not needed with modem transmission protocols. The bar code number is divided by 10, until the number (or modulus) is less than 10. If the modulus subtracted from 10 (remainder) is equal to zero, then the bar code number is valid. 3) Concatenate (6400, 5055, 700 Series, CK30, CK31, CV60) Each bar code read is added to the end of the previous bar code read until the 6400, 5055, 700 Series, CK30, CK31, or CV60 Terminal meets a condition forcing transmission to the host. When this option is OFF, each bar code read is placed at the beginning of the current input field. After a bar code is placed in a field, any subsequent read replaces the first read. 4) BC Type Char (6400, 59XX, 17XX, 11XX, 700 Series, CK30, CK31, CV60) This adds a character associated with the bar code type at the beginning of the scanned bar code. See page 382 for bar code type characters. 5) Stream Scan If the scanned bar code is too big for the input field, the overflow information appears in the next field and continues until the entire bar code is entered. When this option is OFF, and the scanned bar code is too big for the input field, the overflow information is dropped. 6) Scan All Flds When this option is selected, the scanner is enabled when the cursor is in an input field. When this option is OFF, the host computer must enable the scanner for each input field that requires scanned data. 7) More This brings you additional scanning options that adjust scanning timeout and characters sent before and after the scanned data. S 1) Scan Timeout (59XX, 17XX, 11XX) Use this option to adjust the scanning timeout period from 1 to 200 seconds. When using a proximity-detect scanner, you can shorten the timeout period to speed up scanning while also reducing the duration of errant scans. With a long-range scanner, you may want to increase the timeout period to ensure sufficient aiming time. Scan Timeout Seconds XXX
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
131
Page 156
Chapter 4, Using the Terminal Emulation Menus
S 2) Scan PreChar and 3) Scan PostChar Enter a hexadecimal value from 00–FF for the character to be sent preceding the scanned data or after the scanned data. The value of 20h means that pre- or post-characters are not sent. S 4) ParmsBySession (5020, 700 Series, CK30, CK31, CV60) When enabled, the symbology parameters under 1) Set-up Parms > 2) Barcode Parms configure Windows CE terminal scanning devices on a per-session basis. When disabled (default), the 2) Barcode Parms option is ignored. The TE 2000 application does not configure symbology parameters for Windows CE terminal scanning devices. The settings selected via the Windows CE System Data Collection applet are used for both TE 2000 sessions. You can configure the symbology parameters under 1) Set-up Parms > 2) Barcode Parms , however these are not used. S 5) Use Wedge Mode (700 Series, CK30, CK31, CV60) This causes the TE 2000 application to use the system Scanners and Symbologies settings. All scanned data will come into the TE 2000 application from the system Virtual Wedge per the Virtual Wedge settings as if the scanned bar code characters were typed into the keyboard. When Use Wedge Mode is enabled, none of the TE 2000 menu options for scanning will function, such as the following: S Auto Tab Scan, Aut Entr Scn, BRT Auto Enter, ANY Auto Enter, Scan PreChar, Scan PostChar, symbology enable, disable, mix-max or fixed lengths, drop leading, or trailing characters. Scanner data will not be inhibited when in a non-scannable field in TE 2000 3270 or TE 2000 5250. When Use Wedge Mode is enabled, all of the system Scanners and Symbologies capabilities will be available. This means that all of the symbology options and grid options for special edits can be used. Use Wedge Mode can be enabled in TE_SETTINGS.INI by session but only the setting for Session 1 will be used. The Session 1 setting will be propogated across all sessions. If you enable Use Wedge Mode in TE 2000 menus and then save the parameters, you will see the TE_SETTINGS.INI contains the same Use Wedge Mode value for all sessions. Scan Options 1) Scan Timeout 2) Scan PreChar 3) Scan PostChar 4) ParmsBySession 5) Use Wedge Mode
132
1) Scan Timeout is for 59XX, 17XX, 11XX 4) ParmsBySession is for 5020, 700 Series, CK30, CK31, CV60 5) Use Wedge Mode is for 700 Series, CK30, CK31, CV60
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
Page 157
Chapter 4, Using the Terminal Emulation Menus
Scan Options to Enable Bar Codes There are menus of options to enable (or disable) various bar code symbologies. To enable a bar code, press the numeric key corresponding to the number of the bar code symbology (shown on menu), then press [Enter]. After enabling a particular bar code, options may have to be selected for the bar code. After selecting the desired options, set the length requirements (such as minimum and maximum length, fixed lengths, leading and trailing character options, etc.). Once the length requirements are set, the terminal returns to the same Scan Options menu. Choose another bar code symbology from that menu or press [Enter] to advance to the next Scan Options menu. Scan Options 1) UPC 2) EAN 3) Code 39 4) Code 128 5) Codabar
4) Sys 1 UPCE is for 6400, 17XX, 11XX, 700 Series, CK30, CK31, CV60 3) Extended is blank for 700 Series, CK30, CK31, CV60 6) Relax Std is for 59XX, 17XX, 11XX
UPC 1) Enabled 2) Add-On 2 3) Add-On 5 4) Sys 1 UPCE 5) Sys 0 UPCE 6) Expand E To A
Code 39 1) Enabled 2) Chk Digit 3) Extended 4) Encoded 5) Auto-Encoded 6) Relax Std 7) Full ASCII
[1]
[3]
[2]
[4]
EAN 1) Enabled 2) Add-On 2 3) Add-On 5 4) Expand 8 To 13
2) Add-On 2 and 3) Add-On 5 if using 700 Series, CK30, CK31, or CV60, see the following note.
Code 128 1) Enabled 2) UCC/EAN 3) No UCC Type 4) UCC F1 Value
[6] RELAX CODE 39 1) Quiet zone 2) Data Decode 3) Element Decode 4) START Decode
[5]
Codabar 1) Codabar 2) ABC Codabar
2) ABC Codabar is for 59XX, 17XX, 11XX
Note: For 700 Series, CK30, CK31, CV60 Terminals, this implementation of the TE 2000 application processes EAN 8 and UPC E bar codes in the same manner. The type character for EAN 8 with Add-On 2 or Add-On 5 will decode as UPC E with Add-On 2 or Add-On 5, respectively. The bar code type character will also indicate UPC E with Add-On 2 or Add-On 5, respectively. Consequently, the drop leading and trailing UPC options will be used when an EAN 8 with Add-On 2 or Add-On 5 is decoded.
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
133
Page 158
Chapter 4, Using the Terminal Emulation Menus
Scan Options 2 (Additional Bar Codes) This menu offers additional bar code selections. After enabling a bar code symbology, various options, including length can be set. When all options are set, the display returns to the Scan Options 2 menu. This menu and the bar code symbologies to be enabled are shown below. When all needed bar code symbologies are enabled, press [Enter] to return to the Scan Options menu. Press [Enter] again to back out and return to the 1) Set-up Parms menu. Scan Options 2 1) Plessey 2) Str 2of5 3) Int 2of5 4) CI 2of5 5) Code 11 6) Code 93
5) Code 11 is for 59XX, 17XX, 11XX, 700 Series, CK30, CK31, CV60
3) MOD11 Chk is blank for 700 Series, CK30, CK31, CV60 4) Allow Alpha is for 59XX, 17XX, 11XX
Plessey 1) Enabled 2) MOD10 Chk 3) MOD11 Chk 4) Allow Alpha
Int 2of5 1) Enabled 2) Chk Digit
Code 11 1) Enabled 2) Chk Dig 1 3) Chk Dig 2
134
[1]
[3]
[5]
[2]
Str 2of5 1) Enabled 2) Disabled
[4]
CI 2of5 1) Enabled 2) Disabled
[6]
Code 93 1) Enabled 2) Disabled
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide