Page 159
Chapter 4, Using the Terminal Emulation Menus
Lengths Options The Lengths Options menus determine the maximum and minimum length for a specific bar code symbology. Setting the length of enabled bar codes helps the terminal determine if a scanned bar code is valid and improves response time. The length options must be set for each enabled bar code. Enter this information in the order listed. 1 Key in the maximum length (0–99), then press [Enter]. For 700 Series, CK30, CK31, CV60 Terminals, set this as high as you intend to set the minimum length. 2 Key in the minimum length (0–99), then press [Enter]. 3 Fixed-length entries override the maximum and minimum length entries (minimum and maximum are used for chosen codes). If fixed lengths are not needed for the enabled bar code, enter zero (0). Enter the fixed length (0–99), then press [Enter]. Up to four prompts to set another fixed length will appear. Enter zero (0) for the unused fixed lengths. Note that I 2 of 5 only supports fixed lengths 1 and 2. Entries in 3 and 4 are ignored. 4 Enter the number of characters (0–15) to drop from the front (leading) edge of the scanned bar code, then press [Enter]. 5 Enter the number of characters (0–15) to drop from the rear (trailing) edge of the scanned bar code, then press [Enter]. 700 Series, CK30, CK31, CV60 Exceptions The following exceptions apply only to 700 Series, CK30, CK31, and CV60 Terminals: S Codabar, Str 2of5, Int 2of5, and CI 2of5 bar code symbologies set the length, if fixed-length 1 is non-zero, to three fixed-length entries equal to the first three fixed-lengths (fourth fixed-length is ignored). Otherwise, the length is set to greater than or equal to the minimum length. S Code 39, Code 128, Code 93, and Plessey set the length to any length greater than or equal to the minimum length. S UPC/EAN and Code 11 lengths are not used, ANY is allowed. S Codabar options will not decode less than two data characters (four characters including Start and Stop). S CI 2of5 options override Str 2of5 options, if both CI 2of5 and Str 2of5 are selected. S EAN Add-on settings override UPC add-on settings, if both UPC and EAN options are selected. S If “Sys 1 UPCE” or “Sys 0 UPCE” is selected, then both UPCE number system 0 and 1 are enabled. S Code 11 does not support “No check digits.” Select either 1 check digit (Chk Dig 1) or 2 check digits (Chk Dig 2) according to your bar codes. If neither check digit option is selected, then 2 check digits will be used as a default. TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
135
Page 160
Chapter 4, Using the Terminal Emulation Menus
After all of the length options are set for the enabled bar code, the display returns to either the Scan Options menu or the Scan Options 2 menu (pending on from which menu the bar code was enabled).
(bar code type) Max Length xx
(bar code type) Max Length xx Min Length xx Fix Length 1 xx Fix Length 2 xx Fix Length 3 xx
(bar code type) Max Length xx Min Length xx
(bar code type) Max Length xx Min Length xx Fix Length 1 xx Fix Length 2 xx Fix Length 3 xx Fix Length 4 xx
(bar code type) Max Length xx Min Length xx Fix Length 1 xx
(bar code type) Drop Leading xx
(bar code type) Max Length xx Min Length xx Fix Length 1 xx Fix Length 2 xx
(bar code type) Drop Leading xx Drop Trailing xx
3) Protocol Opts Use the 3) Protocol Opts menu to designate the type of terminal emulation the host supports. You can also use it to designate additional commands and command sets. Protocol Opts 1) Host View Sze 2) Data Stream 3) Extended Cmds 4) 5250 5) 3270 6) VT/ANSI 7) Native
136
7) Native is blank if UDP Plus or TCP/IP
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
Page 161
Chapter 4, Using the Terminal Emulation Menus
1) Host View Sze The 1) Host View Sze option tells the terminal the format of display information sent from the host. The display viewing size equals 1920 (the number of rows times the number of columns). The exception is with 5250 Terminal Emulation which has an additional row for error messages and therefore has 2000 characters. The default setting for Native Terminal Emulation is 120 columns by 16 rows (equals 1920). The default for VT/ANSI Terminal Emulation is 80 columns by 24 rows (equals 1920). The default for 5250 Terminal Emulation is 80 columns by 24 rows (25 with error messages). The default for 3270 Terminal Emulation depends on what the original setting was before changing to the 3270 Terminal Emulation. Remember that the total characters must equal 1920 (number of rows by the number of columns) unless using 5250 Terminal Emulation with error messages. Enter a number between 1–80 to change the width. Press [Enter] to return to the 3) Protocol Opts menu. “xx” is the width.
Host View Sze Width xx
2) Data Stream Enter the number corresponding to the type of host computer to specify the data stream used. Press [Enter] to return to the 3) Protocol Opts menu. Data Stream 1) Native 2) 3270 3) 5250 4) VT/ANSI
1) Native is blank if UDP Plus or TCP/IP
Note: For 2415, 2425, 2435A, 2455, 2475, 248X, 5020, 700 Series, CK30, CK31, and CV60 Terminals, you can also set the emulation type through the 1) ITC Server or 3) Direct Connect options.
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
137
Page 162
Chapter 4, Using the Terminal Emulation Menus
For information about 3270, 5250, or Native TE, see these manuals: S TE 2000 3270 Terminal Emulation Programmer’s Guide (P/N 977-055-003) S TE 2000 5250 Terminal Emulation Programmer’s Guide (P/N 977-055-004) S Native Terminal Emulation Programmer’s Guide (P/N: 977-055-006)
3) Extended Cmds (Commands) Use 3) Extended Cmds to enable or disable extended commands. By default, extended commands are disabled. For more information about extended commands, see Chapter 7, “Extended Commands.” When this option is enabled, the host computer can change or use RS-232 communications (such as printers), bar code options, display screen and font size, and error tone features of the unit. Press [1] to enable or press [2] to disable the extended command list. Press [Enter] to return to the 3) Protocol Opts menu. Extended Cmds 1) Enabled 2) Disabled
4) 5250 (Options) The 4) 5250 menu enables the following features if the 5250 communication protocol is used. Press the appropriate number to enable an option, then press [Enter] to return to the 3) Protocol Opts menu. 1) Beep On Error Causes the buzzer to emit when an error condition occurs; does not lock up the keyboard. 2) Auto Tab Scan Causes the cursor to automatically tab forward to the next input field when a good scan is obtained. 3) Telnet (blank for 5020, 700 Series, CK30, CK31, CV60) Handles the Telnet option negotiations to establish a session with an appropriate telnet server. Note: 3) Telnet is not changeable if TCP/IP is used.
138
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
Page 163
Chapter 4, Using the Terminal Emulation Menus
4) Device Name Enters a physical name for a device. This is 1–10 characters with allowable values of A–Z, a–z, 0–9, the pound symbol (#), the dollar sign ($), the ampersand (@), and an underscore ( _ ). 5250E RFC 1572 Support. Note: The first character of 4) Device Name cannot start with a number (0–9). The following screen displays after a physical name is entered. S 1) 5250 Allow Alias If this is enabled, and your current device name returns an error in use, then the terminal attempts to append a “$” (dollar sign) to the end of your device name to initiate a session to your host. When disabled, the device name is resent to the host for the host to send a FIN packet to the terminal, causing the terminal to reboot. This continues until the device name is no longer in use. Allow Alias 1) 5250 Allow Alias
5) Allow NAWS (Negotiate About Window Size) When enabled, the terminal will support Telnet option 31 if prompted. When disabled, this option will return a “won’t do” message. 6) Skip FldExit When this option is enabled, a field that would generate an error code of “0020” (field exit required) when [Enter] was pressed now sends the field data. The legacy TE application would send the entire field so a “7” entered into a 3-character blank-filled field would transmit as “7bb”, a “12” would transmit as “12b”. The TE 2000 application strips the field fill characters so “7” will transmit as a “7”, “12” will transmit as a “12” and so forth. Note A “b” indicates a one-byte space. 7) More Select 7) More to modify the function of the period key or backspace key. S 1) Period–Comma (2415, 2425, 2435A, 2455, 2475, 248X) Select 1) Period–Comma to change the period key ( . ) to a comma. S 2) Destructive BS (backspace) Press [2] to use the backspace key to remove (delete) any previouslykeyed data characters. When disabled, the backspace key goes back one character, but does not delete that character. TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
139
Page 164
Chapter 4, Using the Terminal Emulation Menus
S 3) Lock Error Msg The TE 2000 cursor modes ensure that the cursor location of the screen and its surrounding data is visible. The 5250 error message line is typically not visible because the error message line 24 is too far away from the cursor location. Enabling this option causes a 5250 Write Error Code command error message to be visible by placing the cursor on the error message line. When the RESET key is pressed, the cursor is restored to where it would have been if this option was not enabled (the location specified by a 5250 Insert Cursor command) and the cursor mode option then causes that area of the screen to be visible. Disabling this option causes normal behaviour for the 5250 Write Error Code command error message. The Write Error Code command error message is displayed on the error message line of the screen and the cursor is placed at the location specified by the host Insert Cursor command. The cursor mode then causes the cursor area of the screen to be visible. S 4) Use Color When enabled, the TE 2000 5250 application emulates single byte IBM-5292-2 and double byte IBM-5555-C01 terminals. Monochrome was and still emulates single byte IBM-5291-1 and double byte IBM-5555-B01 terminals. The 5250 Column Separator attribute is emulated using the ExtraLight font attribute which may not be noticeable on some terminals. 5250 1) Beep On Error 2) Auto Tab Scan 3) Telnet 4) Device Name 5) Allow NAWS 6) Skip FldExit 7) More
3) Telnet is blank for 5020, 700 Series, CK30, CK31, CV60
[7] 5250 1) Period-Comma 2) Destructive BS 3) Lock Error Msg 4) Use Color
1) Period-Comma is for 2415, 2425, 2435A, 2455, 2475, 248X
5) 3270 (Options) The 5) 3270 menu enables the following features if the 3270 communication protocol is used. Press the appropriate number to enable an option, then press [Enter] to return to the 3) Protocol Opts menu. 1) Keybrd Unlock Unlocks the keyboard after the [PA1], [PA2], or [CLEAR] keys are pressed. (Normally the keyboard remains locked, until unlocked or the terminal is reset by the host, after any of these keys are pressed.) When using Token Ring on your host, the tab key also unlocks the keyboard.
140
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
Page 165
Chapter 4, Using the Terminal Emulation Menus
2) Auto Tab Scan Causes the cursor to tab forward to the next input field when a good scan is obtained. Note: 2) Auto Tab Scan cannot be enabled at the same time as 3) Auto Entr Scan. 3) Auto Entr Scan Actuates the <Enter> function when a good scan is obtained. Note: 3) Auto Entr Scan cannot be enabled at the same time as 2) Auto Tab Scan. 4) Emulate 3210 (6400, 5055, 59XX, 17XX, 11XX) The Intermec 3210 emulation option allows the 3270 keyboard to emulate an RT3210 Hand-Held Computer, performing the same functions. For full 3210 compatibility, disable buffering the keyboard, set cursor to lazy mode, and set the LCD Parms to Key Uppercase. 5) Telnet (blank for 5020, 700 Series, CK30, CK31, CV60) Handles telnet option negotiations to establish a session with an appropriate telnet server. Note: 5) Telnet cannot be changed if you are using TCP/IP. 6) Origin Set When enabled, resets the screen origin when an exclamation mark is found in the data stream. 7) More Select 7) More for additional features. S 1) Device Name Enters a physical name for a device. This is 1–10 characters with allowable values of A–Z, a–z, 0–9, the pound symbol (#), the dollar sign ($), the ampersand (@), and an underscore ( _ ). 3270E RFC 2355 Support. Note: The first character of 1) Device Name cannot start with a number (0–9). S 2) Allow NAWS (Negotiate About Window Size) When enabled, the terminal will support Telnet option 31 if prompted. When disabled, this option will return a “won’t do” message. S 3) BRT (bright) Auto Enter When enabled, if the last field on a screen has the reverse video attribute set, then when that field is exactly filled, the terminal will automatically send the data for this screen back to the host with an “Enter AID” code. If disabled, the screen will wait for the user to hit the AID key prior to sending data back to the host. Default is disabled.
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
141
Page 166
Chapter 4, Using the Terminal Emulation Menus
S 4) Any Auto Enter When enabled, an automatic “enter” occurs when a reverse video attribute field is filled by keying or scanning data. Any extra scanned data is discarded. If disabled, the screen will wait for the user to hit the AID key prior to sending data back to the host. Default is disabled. 3270 1) Keybrd Unlock 2) Auto Tab Scan 3) Auto Entr Scn 4) Emulate 3210 5) Telnet 6) Origin Set 7) More
4) Emulate 3210 is for 6400, 5055, 59XX, 17XX, 11XX 5) Telnet is blank for 5020, 700 Series, CK30, CK31, CV60
[7] 3270 1) Device Name 2) Allow NAWS 3) BRT Auto Enter 4) Any Auto Enter
6) VT/ANSI The 6) VT/ANSI menu enables the following features if the VT/ANSI communication protocol is used. VT/ANSI 1) DEL To BS 2) CR To CRLF 3) Auto Entr Scn 4) Auto Tab Scan 5) Local Echo 6) AnswerBack 7) More
1) DEL to BS (Delete to Backspace) Causes the [CLEAR] key to delete the character to the left of the cursor position, and moves the cursor back one space. When this option is not enabled, the [CLEAR] key deletes the character at the cursors position. Default is disabled. 2) CR to CRLF (Carriage Return to Carriage Return/Line Feed) Causes <Enter> to perform a carriage return and a line feed. When this option is not enabled, <Enter> performs a carriage return only. Default is disabled. 3) Auto Entr Scn (Auto Enter Scan) Actuates the <Enter> function whenever a good scan is obtained. Default is enabled for version 6.60 or greater, otherwise the default is disabled. Note: 3) Auto Entr Scn cannot be enabled at the same time as 4) Auto Tab Scan.
142
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
Page 167
Chapter 4, Using the Terminal Emulation Menus
4) Auto Tab Scan Causes the terminal to automatically tab to the next input field when a good scan is obtained. Default is disabled. Note: 4) Auto Tab Scan cannot be enabled at the same time as 3) Auto Entr Scan. 5) Local Echo Allows characters to be displayed from terminal memory but not from host memory. Default is disabled. 6) AnswerBack Enables you to enter a character string that is sent to the host in response to an inquiry (hexadecimal 05). The range is 0–30. Default is null string for 2415, 2425, 2435A, 2455, 2475, 248X, 6400, 5020, 5055, 59XX, 17XX, 11XX Terminals and the terminal’s serial number for 700 Series, CK30, CK31, CV60 Terminals. AnswerBack Message
If you enter any of the following control characters, it is sent out. Note that control strings count as one character. <ACK> <BEL> <BS> <CAN> <CR> <DC1>
<DC2> <DC3> <DC4> <DLE> <EM> <ENQ>
<EOT> <ESC> <ETB> <ETC> <FF> <FS>
<GS> <HT> <LF> <NAK> <NUL> <RS>
<SI> <SO> <SOH> <STX> <SUB> <SYN>
<US> <VT>
7) More Calls up the following VT/ANSI More Options screen. VT/ANSI More Options 1) Screen Lock 2) DiscreteBells 3) UserKey Locked 4) RS232 Setup 5) VT220 Mode 6) Lock Mode 7) More
2) DiscreteBells is for 6400, 5055, 59XX, 17XX, 11XX 4) RS232 Setup is for 6400, 5020, 5055, 59XX, 17XX, 11XX, 700 Series, CK30, CK31, CV60
S 1) Screen Lock Sets and locks the screen to a specified size. Any characters outside this screen size are ignored by the hand-held unit. Default is disabled. TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide
143
Page 168
Chapter 4, Using the Terminal Emulation Menus
S 2) DiscreteBells (6400, 5055, 59XX, 17XX, 11XX) If enabled, the terminal beeps for each bell character the host sends. If disabled, the unit ignores the bell characters if it is already beeping. Default is disabled. S 3) UserKey Locked If set, the host ignores a host command defining the Function keys. Default is disabled. S 4) RS232 Setup (6400, 5020, 5055, 59XX, 17XX, 11XX, 700 Series, CK30, CK31, CV60) When using the media copy command, use this option to set up the communications port, then press [Enter] to return to 3) Protocol Opts. S 1) RS232 Baud Rate Select 1200, 2400, 4800 (6400, 5055, 59XX, 17XX, 11XX), 9600, 19200, 38400, 57600, or 115200 (5020, 700 Series, CK30, CK31, CV60). Default is 9600. S 2) RS232 Parity (6400, 5055, 59XX, 17XX, 11XX) Select from Odd, Even, or None. Default is None. S 3) RS232 Stop Bits (6400, 5055, 59XX, 17XX, 11XX) Select either 1- or 2-bits. Default is 1. S 4) RS232 Data Bits (6400, 5055, 59XX, 17XX, 11XX) Select either 7- or 8-bit. Default is 8.
144
TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide