For the Intermec 2425

Page 139

Chapter 4, Using the Terminal Emulation Menus

1) Set-up Parms (2415, 2425, 2435A, 2455, 2475, 248X) This is password-protected to prevent unauthorized users from changing parameters. You can customize the parameter’s CONFIG.DAT setup file to change the password. See Chapter 5, “Customizing Your Configuration.” Changed parameters apply to the current session. If more than one session is available, use the 7) More > 2) Save Parms > 4) Session Menu to verify or change the current session before going to the next session. To open the 1) Set-up Parms menu, press [1], [Enter], then type “cr52401” at the prompt to access the following menus. Set-up Parms 1) Communication 2) Barcode Parms 3) Protocol Opts 4) Display Opts 5) Radio Comm 6) Cold Start 7) More

1) ITC Server is for 2415, 2425, 2435A, 2455, 248X with TE/UDP Plus 2) RTC/WTP is for 2415, 2425, 2435A, 2455, 2475, 248X with RTC 3) Direct Connect is for 2415, 2425, 2435A, 2455, 2475, 248X with TE/IP

7) Native is blank if UDP Plus or TCP/IP

3) Security ID is for Proxim radios

3) COM Select is for 248X

Controller Type 1) ITC Server 2) RTC/WTP 3) Direct Connect

Protocol Opts 1) Host View Sze 2) Data Stream 3) Extended Cmds 4) 5250 5) 3270 6) VT220 7) Native

Protocol 1) SST 2) SST-Diag Mode 3) Security ID

Set-up Parms 1) Menu Password 2) 3) COM Select

[1] [2]

[3] [4]

5) Radio Comm is blank for 2415, 2425, 2435A, 2455, 2475, 248X Terminals without either an 802.1x supplicant radio driver or UDP Plus

Barcode Parms 1) Code 39 Encoded 2) 3) Concatenate 4) RS232 Stream 5) Stream Scan 6) Scan All Flds

Display Opts 1) Backlight 2) Cursor Mode 3)

Cold Start

[5] [6]

Enter “Y” To Cold Start terminal:

[7]

TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide

115

Page 140

Chapter 4, Using the Terminal Emulation Menus

6400, 5055, 59XX, 17XX, 11XX Menus The following menus pertain to the 6400, 5055, 59XX, 17XX, and 11XX Terminals. To return to the Main Menu, press [Enter] several times, then select 6) Exit Menus, to return to the operating system. Main Menu 1) Set-up Parms 2) LCD Parms 3) Beeper Setup 4) Tests 5) Version Info 6) Exit Menus 7) More

Set-up Parms 1) Communication 2) Barcode Parms 3) Protocol Opts 4) Display Opts 5) Radio Comm 6) Cold Start 7) More

3) Beeper Select is for 6400, 5055, 17XX, 11XX

Beeper Setup 1) Key Click 2) Error Tone 3) Beeper Select

MLID Name and MLID ver are for 6400, 5055

Version Info Firmware <TE Program Name> Version <number> Date <ddmmyy> MLID Name ZZZZZZ MLID ver xx.xx (mac address)

116

[1]

[3]

[5]

[2]

[4]

[7]

LCD Parms 1) LCD Contrast 2) Screen Size 3) Screen Mode 4) Annunciators 5) Backlight 6) Key Uppercase 7) Scroll Window

1) LCD Contrast and 5) Backlight is for 59XX, 17XX 4) Annunciators is blank for 17XX, 11XX

Tests 1) Peripherals 2) Converters 3) Memory View 4) Packet Driver 5) Numbers 6) Timed Numbers

2) Converters is for 59XX

Main Menu 2 1) Keyboard Opts 2) Save Parms 3) Cloning Opts 4) Session Menu

3) Cloning Opts is for 59XX, 17XX, 11XX

TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide

Page 141

Chapter 4, Using the Terminal Emulation Menus

1) Set-up Parms (6400, 5055, 59XX, 17XX, 11XX) This is password-protected to prevent unauthorized users from changing parameters. You can customize the parameter’s CONFIG.DAT setup file to change the password. See Chapter 5, “Customizing Your Configuration.” Changed parameters apply to the current session. If more than one session is available, use the 7) More > 2) Save Parms > 4) Session Menu to verify or change the current session before going to the next session. To open the 1) Set-up Parms menu, press [1], [Enter], then type “cr52401” at the prompt to access the following menus. Set-up Parms 1) Communication 2) Barcode Parms 3) Protocol Opts 4) Display Opts 5) Radio Comm 6) Cold Start 7) More

2) RTC/WTP is for 6400, 5055, 59XX, 11XX, 17XX with RTC 3) Direct Connect is for 6400, 5055 with TE/IP

7) Native is blank if UDP Plus or TCP/IP 1) Backlight is for 6400, 17XX, 11XX 3) Remote Disp is for 17XX

Controller Type

1) 2) RTC/WTP 3) Direct Connect

[1] [2]

Protocol Opts 1) Host View Sze 2) Data Stream 3) Extended Cmds 4) 5250 5) 3270 6) VT220 7) Native

[3] [2]

Display Opts 1) Backlight 2) Cursor Mode 3) Remote Disp

[4] [5]

Cold Start Enter “Y” To Cold Start terminal:

[6]

[7]

TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide

Scanner Type 1) No Scanner 2) Wand 3) Laser 4) Wand Emulate 5) Auto Detect

2) Wand, 4) Wand Emulate, 5) Auto Detect are for 59XX, 17XX, 11XX

Scan Options 1) Redundancy 2) MOD 10 Check 3) Concatenate 4) BC Type Char 5) Stream Scan 6) Scan All Flds 7) More

1) Redundancy is for 6400, 59XX, 17XX, 11XX 3) Concatenate is for 6400, 5055 4) BC Type Char is for 6400, 59XX, 17XX, 11XX

Protocol 1) SST 2) SST-Diag Mode 3) Security ID

Set-up Parms 1) Menu Password 2) Print Device 3) COM Select

3) Security ID is for Proxim radios

2) Print Device is for 6400 3) COM Select is for 5055

117

Page 142

Chapter 4, Using the Terminal Emulation Menus

5020, 700 Series, CK30, CK31, CV60 Menus The following menus pertain to the 5020, 700 Series, CK30, CK31, and CV60 Terminals. To return to the Main Menu, press [Enter] several times, then select 6) Exit Menus, to return to the operating system. Main Menu 1) Set-up Parms 2) LCD Parms 3) Beeper Setup 4) Tests 5) Version Info 6) Exit Menus 7) More

6) Cold Start is for 5020 6) Exit TE2000 is for 700 Series, CK30, CK31, CV60

Set-up Parms 1) Communication 2) Barcode Parms 3) Protocol Opts 4) Display Opts 5) 6) Cold Start 6) Exit TE2000 7) More Beeper Setup 1) Key Click 2) Error Tone 3) Beeper Select

Version Info Firmware <TE Program Name> Version <number> Date <ddmmyy>

[1]

[3]

[5]

[2]

[4]

[7]

3) Beeper Setup is for CK30, CK31

LCD Parms 1) 2) Screen Size 3) Screen Mode 4) Annunciators 5) 6) Key Uppercase 7) Scroll Window 7) More Tests 1) Peripherals 2) 3) 4) 5) 6)

7) Scroll Window is for 5020 7) More is for 700 Series, CK30, CK31, CV60

Main Menu 2 1) Keyboard Opts 2) Save Parms 3) 4) Session Menu

1) Set-up Parms (5020, 700 Series, CK30, CK31, CV60) This is password-protected to prevent unauthorized users from changing parameters. For 5020 Terminals and 700 Series, CK30, CV60 Terminals with TE 2000 application versions older than 8.00, you can customize the parameter in the CONFIG.DAT setup file to change the password. For 700 Series, CK30, CK31, and CV60 Terminals with TE 2000 application version 8.00 or greater, you can customize the parameter in the TE_SETTINGS.INI setup file. See Chapter 5, “Customizing Your Configuration.” Changed parameters apply to the current session. If more than one session is available, use the 7) More > 2) Save Parms > 4) Session Menu to verify or change the current session before going to the next session. To open the 1) Set-up Parms menu, press [1], [Enter], then type “cr52401” at the prompt to access the menus on the next page.

118

TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide

Page 143

Chapter 4, Using the Terminal Emulation Menus

Set-up Parms 1) Communication 2) Barcode Parms 3) Protocol Opts 4) Display Opts 5) 6) Cold Start 6) Exit TE2000 7) More

6) Cold Start is for 5020. 6) Exit TE2000 is for 700 Series, CK30, CK31, CV60.

For 5020 1) ITC Server is for 5020, 700 Series, CK30, CK31, CV60 with TE/UDP Plus 3) Direct Connect is for 5020, 700 Series, CK30, CK31, CV60 with TE/IP

Controller Type 1) ITC Server 2) 3) Direct Connect

[1] [2]

Barcode Parms 1) Code 39 Encoded 2) 3) Concatenate 4) 5) Stream Scan 6) Scan All Flds

For 700 Series, CK30, CK31, CV60 Protocol Opts 1) Host View Sze 2) Data Stream 3) Extended Cmds 4) 5250 5) 3270 6) VT220 7)

[3] [2]

For 700 Series, CK30, CK31, CV60

1) Backlight is for 700 Series 6) Font Quality is for CK30, CK31

Display Opts 1) Backlight 2) Cursor Mode 3) Select Font 4) 5) Display Colors 6) Font Quality 7) More

For 5020

[4] [4]

For 700 Series, CK30, CK31, CV60 Exit TE2000

Display Opts 1) 2) Cursor Mode 3)

For 5020 [6]

[6]

Enter “Y” To Exit TE2000:

Set-up Parms 1) Menu Password 2) Print Device 3)

Scan Options 1) 2) MOD 10 Check 3) Concatenate 4) BC Type Char 5) Stream Scan 6) Scan All Flds 7) More

Cold Start Enter “Y” To Cold Start terminal:

[7]

TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide

119

Page 144

Chapter 4, Using the Terminal Emulation Menus

1) Set-up Parameters The following setup parameter information pertains to all terminals unless otherwise noted.

1) Communication The communication option for the terminals are broken down as follows: S 2415, 2425, 2435A, 2455, 2475, 248X, 5020, 700 Series, CK30, CK31, CV60 with UDP Plus 1) ITC Server via the next paragraph. S 2415, 2425, 2435A, 2455, 2475, 248X with RTC 2) RTC/WTP on page 122. S 6400, 5055, 59XX, 17XX, 11XX with RTC 2) RTC/WTP on page 124. S 6400, 5055 with TCP/IP 3) Direct Connect on page 126. S 2415, 2425, 2435A, 2455, 2475, 248X, 5020 with TCP/IP, 700 Series, CK30, CK31, CV60 3) Direct Connect on page 128.

1) ITC Server (2415, 2425, 2435A, 2455, 2475, 248X, 5020 with TE/UDP Plus, CK30, CK31, CV60) ITC (Intermec Technologies Corporation) Server options are as follows. To set the options, select 1) ITC Server, 2) Host/Srvr, then the Server Setup option (Server A, B, or C). Controller Type 1) ITC Server 2) 3)

[1] ITC Server 1) 2) Host/Srvr

[2] Server Setup 1) Server A 2) Server B 3) Server C

Server <A, B, or C> Server IP <IP address>

Host Setup<A, B, or C> 1) Host Name 2) Upline Prot 3) Port Number 4) Emulation

120

TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide

Page 145

Chapter 4, Using the Terminal Emulation Menus

Server IP <A, B, or C> The Server <A> IP address is read from either the CONFIG.DAT or TE_SETTINGS.INI file (if one is saved) or the TE 2000 application on the terminal. When an IP address is entered, it is written to the terminal’s copy of the TE 2000 application for the next boot. If using the Server <B> or Server <C> option as a fallback IntermecR Application Server, enter the server’s IP address or DNS name. The boot sequence continues to try Server <A>, <B>, then <C> in this order by filling the firmware controller slot with the IP values entered for each server.

Host Setup <A, B, or C> Menu options are as follows: Host Setup<A, B, or C> 1) Host Name 2) Upline Prot 3) Port Number 4) Emulation

Host<A, B, or C> <3270, 5250, or VT/ANSI> Host Name <host name>

[1]

[2]

Port Number<A, B, or C> <port number> [3]

[4]

Upline Prot<A, B, or C> 1)Telnet 2)SNA

Emulation<A, B, or C> 1) 2) 3270 3) 5250 4) VT/ANSI

1) Host Name The host name can be 64 or fewer characters in length. Enter spaces or punctuation where needed. Note that the TE 2000 application performs an auto-enter when the 64th character is entered. It is case-sensitive and must match a host name in the list of available hosts defined on the Intermec Application Server, or remain blank. The name can also be the IP address of the host to which you want to connect. Enter the IP address as four decimal numbers separated by periods. If a terminal was linked with a host name on the Intermec Application Server, or a default host was configured on this Intermec Application Server, you do not need to enter a host name on this screen.

TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide

121

Page 146

Chapter 4, Using the Terminal Emulation Menus

The terminal displays a list of available hosts if these conditions are met. The user can then select the host from the list. S The Intermec Application Server contains multiple hosts. S The terminal is not linked with a host name on the Intermec Application Server. S The host name is blank. 2) Upline Prot When enabled, upline protocol options do the following: S Telnet (Default) Forces the Intermec Application Server to create a Telnet connection to the host. S SNA Forces the Intermec Application Server to create an SNA connection to the host. 3) Port Number This option overrides the port number set for the upline if you have entered a host name and selected Telnet as your upline protocol. Default port number is 23. The maximum port number is 65535. 4) Emulation Use this option to tell the terminal each host computer type. Default is VT/ANSI. Note: You can also set the type through the 2) Data Stream option on the 3) Protocol Opts menu.

2) RTC/WTP (2415, 2425, 2435A, 2455, 2475, 248X) Use 2) RTC/WTP to set, view, or change the terminal ID. This number allows the host computer to identify individual terminals in the radio data network. Each terminal must have a unique number in the same network. Use the numeric keys on the terminal keyboard to modify its ID. Enter a number between 0–126, then press [Enter] to go to 2) Host/Cntl menus. The 1) Radio Setup and 2) Host/Cntl menus are shown on the following pages. Pending on which option you are exercising you will either advance to the WTP Stack settings or the TCP/IP Stack settings. 1) Radio Setup is done in the firmware with the RTC stack.

122

TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide

Page 147

Chapter 4, Using the Terminal Emulation Menus

WTP Stack Options

Controller Type 1) 2) RTC/WTP 3)

[2] Host/Cntl 1) 2) Host/Cntl

[2] Host/Cntl 1) CNTL A 2) CNTL B 3) CNTL C ENTER

DONE

ENTER

Controller (x) Enter Unit Number xxx

ENTER Controller (x) (cust emulation) unit # xxx Host Name Enter up to 16 characters/Numbers for a name. ENTER Emulation (x) Enter Unit 1) Native 2) 3270 3) 5250 4) VT/ANSI

ENTER

Telnet (x) 1) Enabled 2) Disabled

TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide

ENTER

123

Page 148

Chapter 4, Using the Terminal Emulation Menus

2) RTC/WTP (6400, 5055, 59XX, 17XX, 11XX) Use 2) RTC/WTP to set, view, or change the terminal ID. This number allows the host computer to identify individual terminals in the radio data network. Each terminal must have a unique number in the same network. The 1) Radio Setup and 2) Host/Cntl menus are shown on the following pages. Pending on which option you are exercising you will either advance to the WTP Stack settings or the TCP/IP Stack settings. WTP Settings Use the numeric keys on the terminal keyboard or 5055 external keyboard to modify its ID. Enter a number between 0–126, then press [Enter] to go to the 2) Host/Cntl menus. The LAN ID number can be 0–255 depending on the radio being used. With the RM60/70 radio, the number can be 0–255; with the RM80/90 radio, the range is 0–15. Your terminal only communicates with equipment using the same ID number that you assigned to your LAN. If you enter a LAN ID number different from what is configured in the NET.CFG file you get the following message. If this happens, the system modifies NET.CFG, which is used by WTPPKT.EXE on initializing the terminal.

LAN ID changed Need to reboot to take effect.

124

TE 2000™ VT/ANSI Terminal Emulation Programmer’s Guide