Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 23 of 46

TRAKKER Antares 2425 Hand-Held Terminal User's Manual, pages 221 to 230

Pages 221 to 230 of 452

The original document is the PDF (2.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 2425

Page 221

HelvC NugFont

Co d e 39 Troubleshooting

6

5. Line up the alignment marks on the connector end of the antenna with the alignment marks on the terminal antenna connector. Retaining ring slot Retaining ring opening

Antenna (must be in this position)

Retaining ring

242XU.119

6. Push the new antenna onto the antenna connector until it fits flush and the opening for the retaining ring is visible. 7. Insert the retaining ring into the opening. 8. Push the retaining ring down until it is locked in place. 9. Turn the terminal over and adjust the angle of the antenna as needed.

6-33

Page 222

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Cleaning the Scan Module Window and Display To keep the T2425 terminal in good working order, you need to clean the scan module window and terminal display. Clean these surfaces as often as needed or when they are dirty. To clean the scan module window and display 1. Press q to turn off the terminal.

2. Use a solution of ammonia and water. 3. Dip a clean towel or rag in the ammonia solution and wring out the excess solution. Wipe off the scan module window and terminal display. Do not allow any abrasive material to touch these surfaces. 4. Wipe dry.

6-34

Page 223

HelvC NugFont

Co d e 39 Troubleshooting

6

Running Diagnostics You can run diagnostics on the terminal to help analyze and fix hardware and firmware problems, application problems, and to view system information. You use the TRAKKER 2400 Menu System to run diagnostics. Use this table to determine the diagnostic you want to run on the terminal. Diagnostic Test

Description

Access Point

Lists information about the 0100 Access Point the terminal is communicating with across the network.

Application Events

Shows the current status of each application event to help debug applications.

Battery Monitor

Shows the voltage, temperature, and charging status for the main battery pack.

Battery Status

Shows the power remaining in the main battery pack and the power status for the backup battery.

Beeper Test

Sounds a series of beeps to test the beeper by using a range of beep volumes and beep frequencies.

Clear Task Profiles

Clears the Task Status counters so that you can begin accumulating new task statistics for the Task Status screen.

Destructive RAM Test

Extensively tests the RAM.

Display Test

Tests and turns on the pixels on the display to make sure all areas of the display are working correctly.

Error Logger

Lists any errors that the firmware did not expect.

Hardware Configuration

Lists the type of the main hardware components used on the terminal. Also, shows the RF country code configured on the terminal.

Keypad Test

Shows the hexadecimal and decimal key code value for any key on the terminal keypad.

6-35

Page 224

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Diagnostic Tests (continued) Diagnostic Test

Description

Radio Test

Tests the radio to make sure it is working.

RS-232 Loop Back

Verifies that the hardware for the RS-232 port is functioning correctly.

Scanner Test

Tests the laser scanner to make sure it is working.

Subsystem Versions

Lists the version of each major software subsystem loaded on the terminal.

Suspend-Resume Test

Tests the terminal memory to make sure the memory is being preserved through a suspend and resume cycle.

Task Status

Shows the task base address, the percentage of time each subsystem has been running, and the stack usage.

Note: There are two additional diagnostics available from the Software Diagnostics, Event Group Menu. The two diagnostics, Network Events and Network Applications, will be defined in a future release.

Running Diagnostics From the Menu System The TRAKKER 2400 Menu System is a menu-driven application that lets you configure the terminal, view system information, and run diagnostics. You can access the TRAKKER 2400 Menu System and run diagnostics while running any application. To run diagnostics from the TRAKKER 2400 Menu System

) y T 2 M or scan this bar code: Note: You must press the y (Left Enter) key in this key sequence, not the z (Right Enter) or ; keys.

1. Press

6-36

Page 225

HelvC NugFont

Co d e 39 Troubleshooting

6

Enter Test and Service Mode

*..-.* *..-.*

The Main Menu appears.

MAIN

MENU

Configuration Menu Diagnostics Menu System Menu About TRAKKER 2400

_` Select item [Enter] Next screen [F1] Help [Esc] Exit 242XU.001

{

2. Press to choose the Diagnostics Menu and press Menu appears. DIAGNOSTICS

;. The Diagnostics

MENU

Software Diagnostics Hardware Diagnostics System Diagnostics

_` Select item [Enter] Next screen [F1] Help [Esc] Exit 242XU.050

6-37

Page 226

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

The Diagnostics Menu contains these commands: Software Diagnostics Lets you run software diagnostics to help analyze and fix problems on the terminal. For example, you can view the Error Logger file to view system errors. Hardware Diagnostics Lets you run hardware diagnostics to help analyze and fix problems on the terminal. For example, you can check the power remaining and the condition of the batteries. System Diagnostics Lets you run system diagnostics to help analyze and fix problems on the terminal. For example, you can run diagnostics to check the communications between the terminal and the 0100 Access Point or the Model 200 Controller.

[ {

;

3. Press or to choose Software Diagnostics, Hardware Diagnostics, or System Diagnostics and press . One of these menus appear. SOFTWARE DIAGNOSTICS

HARDWARE DIAGNOSTICS

Error Logger Event Group Menu Task Status Clear Task Profiles

Hardware Config Battery Status Display Test Keypad Test Main Board Menu Radio Test RS-232 Loop Back Scanner Test

_` Select item [Enter] Next screen [F1] Help [Esc] Exit 242XU.065

SYSTEM

DIAGNOSTICS

Subsystem Versions Access Point Suspend-Resume Test

_` Select item [Enter] Next screen [F1] Help [Esc] Exit 242XU.069

6-38

_` Select item [Enter] Next screen [F1] Help [Esc] Exit 242XU.067

Page 227

HelvC NugFont

;

Co d e 39 Troubleshooting

6

[ {

4. Press or to choose the diagnostic test you want to run and press . The diagnostic screen appears. Use the information on the screen or follow the instructions to run the diagnostic test. For help, see “Defining the Diagnostics Screens” later in this section.

d to exit each diagnostic screen and to exit the diagnostics menus. 6. Choose another menu from the Main Menu or press d to exit the

5. Press

TRAKKER 2400 Menu System. If you have made any changes, a screen prompts you to store the changes in flash memory. For help, see “Exiting the TRAKKER 2400 Menu System” in Chapter 3.

After you exit the menu system, the T2425 terminal will resume the application you were running when you started the menu system.

Defining the Diagnostics Screens You can find the following information about each diagnostic test in this section: • Description and purpose • Menu where the diagnostic is available • Sample diagnostic screen • Definition and explanation of the diagnostic screen The diagnostics are grouped into three categories: • Software diagnostics • Hardware diagnostics • System diagnostics Within each category, the diagnostics are listed alphabetically by name.

6-39

Page 228

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Defining the Software Diagnostics Screens Each software diagnostic screen is defined in this section.

Application Events Purpose:

A programmer can use the current status of each event to help debug applications running on the terminal.

Where Available: Choose the Event Group Menu from the Software Diagnostics menu. Note: There are two additional diagnostics available from the Software Diagnostics, Event Group Menu. The two diagnostics, Network Events and Network Applications, will be defined in a future release. Sample Screen:

APPLICATION 0:0 1:0 2:0 3:0 4:0 5:0 6:0 7:0

EVENTS

NO SELECT COM1 SELECT COM2 SELECT RESERVED NET SELECT LABEL SELECT KEYBOARD SELECT COM1 TX SELECT

[Enter] Next [Esc] Exit screen

APPLICATION 8:0 9:0 10:0

EVENTS

COM2 TX SELECT NET TX SELECT TIME SELECT

[Enter] Next [Esc] Exit screen

242XU.130

Definition:

The TRAKKER 2425 terminal uses an event-driven architecture. All inputs to the terminal, such as keypad or from the network, arrive in the form of an event. You can check the status of each event using the Application Events screen. When an event is serviced by the application, the event is cleared. 0 means the event is cleared. 1 means the event has occurred (or is set).

6-40

Page 229

HelvC NugFont

Co d e 39 Troubleshooting

6

Clear Task Profile Purpose:

Clears the task profile counters so that you can begin accumulating statistics on the firmware subsystem tasks from a known point in time.

Where Available: Software Diagnostics menu Sample Screen:

CLEAR

TASK

PROFILES

Operating system task profile counters have been cleared.

[Esc]

Exit 242XU.132

Definition:

When you select the Clear Task Profiles option, the terminal clears the %Time field on the Task Status screen.

6-41

Page 230

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Error Logger Purpose:

You can use the Error Logger screen to display any errors that the system could not fix while you were using the terminal. For help solving an error, contact your local Intermec service representative.

Where Available: Software Diagnostics menu Sample Screen:

ERROR LOGGER Current Time:231912 Time Err# Address 024401 0003 90000548 024359 0002 90000548 024358 0001 90000548

[Enter] Next [Esc] Exit screen

242XU.134

Definition:

6-42

;

The Error Logger screens shows the last 30 errors. Press to see the next screen of errors. The first column displays the time in HHMMSS. The second column displays the error number. The third column displays the address or segment offset of the program call that was made to the error logger.