Page 231

HelvC NugFont

Co d e 39 Troubleshooting

6

Task Status Purpose:

A programmer can use the Task Status screens to view the task base address and the percentage of time a task has been running.

Where Available: Software Diagnostics menu Sample Screen:

TASK SLOT 0: 1: 2: 3: 4: 5: 6: 7: 8: 9: 10:

STATUS

ADDRESS ----:---F002:0214 A000:00DA ----:---CE00:001E 2000:0000 DA07:0073 DB06:0047 E000:00E2 ----:-------:----

[Enter] Next [Esc] Exit

%TIME --.-% 00.7% 00.0% --.-% --.-% 10.2% --.-% 00.0% 89.1% --.-% --.-% screen

TASK SLOT 0: 1: 2: 3: 4: 5: 6: 7: 8: 9: 10:

STATUS

STACK ----:---1600:59F8 1600:4F90 ----:---1600:4800 1600:4678 1600:4270 1600:4068 1600:3C60 ----:-------:----

[Enter] Next [Esc] Exit

UNUSED ---0201 0797 ---0587 013D 0391 013E 0292 ------- screen

242XU.131

Definition:

The %Time field measures the relative amount of time that a given software task or component is active. For example, Standby mode in the Power Management software is a component. The %Time that Standby mode is active is directly proportional to battery life. To refresh the statistics and start from a known point in time, use the Clear Task Profile diagnostic option to clear the task status counters.

6-43

Page 232

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Defining the Hardware Diagnostics Screens Each hardware diagnostic screen is defined in this section.

Battery Monitor Purpose:

Use the Battery Monitor screen to get information from the battery monitor processor about the main (lithium-ion) battery pack. You can use the temperature information to make sure you are using the terminal within the operating temperature range.

Where Available: Choose the Main Board Menu from the Hardware Diagnostics menu. Sample Screen:

BATTERY

MONITOR

Battery 8.225 V

Volts (EA)

Battery 25C

Temperature (A6)

Charging: PIC

Rev.:

[Esc]

NO 7

Exit

242XU.006

Definition:

6-44

The screen displays the current volts, temperature, and the charging status (yes or no). The PIC Rev field is the firmware version that is running on the battery monitor processor. The number in parenthesis after the volts and temperature is the hexadecimal value returned from the processor. For more information about the power remaining in the battery pack, use the Battery Status diagnostic screen.

Page 233

HelvC NugFont

Co d e 39 Troubleshooting

6

Battery Status Purpose:

Use the Battery Status screen to find out how much power you have remaining in the main (lithium-ion) battery pack, and to get the current power status for the backup (NiCad) battery.

Where Available: Hardware Diagnostics menu Sample Screen:

BATTERY

STATUS

Main Battery Capacity E

F 30%

BACKUP BATTERY GOOD

[Esc]

Exit

242XU.141

Definition:

Main Battery Capacity tells you the percentage of battery power remaining in the battery pack. For example, there is 30% power remaining. You can continue using the battery pack until the Battery icon appears on the display to indicate a low battery. The backup battery test shows that the backup battery power is either GOOD or LOW. If the status is LOW, turn off the terminal. Let the main battery pack charge the backup battery. The backup battery will be fully charged in approximately 18 hours.

6-45

Page 234

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Beeper Test Purpose:

You can test the terminal beeper to make sure the entire beep volume range and beep frequency range are available and working correctly. The Beeper Test can also help you distinguish the different beep volumes to choose a level that you can hear in your working environment.

Where Available: Choose the Main Board Menu from the Hardware Diagnostics menu. Sample Screen:

BEEPER

TEST

SELECT BEEP TEST: (Hold down any key to stop test) 1-Frequency Up/Down 2-Volume Up/Down 3-Club 39 Jam 4-K. 622

[Esc]

Exit

242XU.145

Definition:

1

Press to test the beep frequency range. The terminal will sound a series of beeps starting from a low frequency beep through the range to a high frequency beep, and then back to a low frequency beep.

2

Press to test the beep volume. The terminal sounds a series of beeps from a quiet beep to a very loud beep. Tests 3 and 4 also test the beep volume and frequency by playing a short tune. If you do not hear any beeps during any of these tests, you may have a problem with the beeper or internal speakers. For help, contact your local Intermec service representative.

6-46

Page 235

HelvC NugFont

Co d e 39 Troubleshooting

6

Destructive RAM Test Purpose:

Use the Destructive RAM Test if you are think the RAM may be bad.

Where Available: Choose the Main Board Menu from the Hardware Diagnostics menu. Sample Screen:

DESTRUCTIVE

RAM

TEST

The following test will cause the unit to reboot, causing loss of all RAM resident data.

PROCEED?

Memory

Pass

#:

Test

Passed

00037

Press a key to Reboot Unit

PRESS 'Y' to proceed...

[Esc]

Exit

242XU.143

Definition:

Y

Before you run this test, save your data and end your current TE session. Press to start the test. All data in RAM will be lost. The terminal starts the RAM test and clears the display. You hear a beep after a successful test of each 64K block of data. After 15 beeps, a test pass is complete and the results appear. The sample screen shows a successful test pass. To run another test pass, do not press a key and the next test begins after a 5 second pause. You may let the test continue and test the RAM several times to get a test over time. To exit the test, press once a test pass is complete. The terminal reboots and restarts your default application.

;

If an error is found, the Destructive RAM Test stops and displays the error address, the data written to RAM, and the data read from RAM. Note this information and contact your local Intermec service representative.

Caution If the Destructive RAM Test fails, stop using the terminal. Contact your local Intermec service representative. Conseil Si le test Destructive RAM échoue, veuillez ne plus utiliser le terminal. Contactez le représentant du service clientèle Intermec de votre région.

6-47

Page 236

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Display Test Purpose:

Use the Display Test screen to make sure that every pixel on the display is working correctly. For example, you may want to test the display if you are not seeing complete characters on the display.

Where Available: Hardware Diagnostics menu Sample Screen:

DISPLAY

[Enter] Next [Esc] Exit

TEST pattern

242XU.135

Definition:

;

;

Press to display each of the four patterns. After 5 seconds, the entire display is filled with the current test pattern. Press to display the next pattern. The first two patterns appear as a shaded pattern and turn off every other pixel. The third pattern turns on every pixel and appears as a black square. The fourth pattern turns off every pixel and appears as a clear square. If any of these patterns do not display correctly, you may have a problem with the display. For help, contact your local Intermec service representative.

6-48

Page 237

HelvC NugFont

Co d e 39 Troubleshooting

6

Hardware Configuration Purpose:

If you are discussing a problem with Intermec, you can use the Hardware Configuration screen to tell the Intermec representative the exact version of hardware on the terminal. You can also use this screen to see the radio frequency and country code that are configured on the terminal.

Where Available: Hardware Diagnostics menu Sample Screen:

HARDWARE

CONFIG

HARDWARE

Country USA

Code: (80,01)

PCMCIA PCMCIA

Display Display Display

Type: Rev.: Cont:

0 0 32

PCB

Type : Rev. : Table:

0 0 0

Keypad Keypad Keypad

[Enter] Next [Esc] Exit screen

Type: Rev.:

Rev.

:

[Enter] Next [Esc] Exit

CONFIG 2 1 1 screen

242XU.142

Definition:

;

Press to display the next screen of hardware information. If you are having a specific problem with one system, such as the radio, note the hardware version on the terminal before contacting your local Intermec service representative. The country code information on the Hardware Configuration screen is only valid when the radio (Network Activate command) is enabled. If the radio is disabled, the country code information is not valid. For help, see “Network Activate” in Chapter 8.

6-49

Page 238

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Keypad Test Purpose:

An application programmer can use the Keypad Test screen to quickly find out the hexadecimal and decimal key code values for any key on the keypad. You can also use the test to make sure the keypad is operating correctly.

Where Available: Hardware Diagnostics menu Sample Screen:

KEYPAD Key 'a' 'b' 'c' 'd' 'e' 'f' 'g' 'h' 'i' 'j' 'k' 'l' 'm'

Hex 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D

[Esc]

Exit

TEST Decimal 97 98 99 100 101 102 103 104 105 106 107 108 109

242XU.133

Definition:

6-50 d

Press any key on the keypad to display the hexadecimal and decimal value of the key. When you press , the terminal pauses for a few seconds to display the hexadecimal and decimal values before you exit the screen.

Page 239

HelvC NugFont

Co d e 39 Troubleshooting

6

Radio Test Purpose:

Use the Radio Test screen to verify that you have a working radio.

Where Available: Hardware Diagnostics menu Sample Screen:

RADIO

TEST

TESTING Test:

PASSED

[Enter] Execute [Esc] Exit test

242XU.138

Definition:

Before you start the test, make sure the radio (Network Activate command) is enabled. If the radio is disabled, the test results on the Radio Test screen are not valid. For help, see “Network Activate” in Chapter 8.

;

Press to start the radio test. The results of the test display on the screen once the test is complete. If SUCCESS or PASSED display, the radio is working correctly. If FAILED displays, note the error number. You may have a problem with the radio inside the terminal. For help, contact your local Intermec service representative. Caution If the Radio Test fails, stop using the terminal. Contact your local Intermec service representative. Conseil Si le test Radio échoue, veuillez ne plus utiliser le terminal. Contactez le représentant du service clientèle Intermec de votre région.

6-51

Page 240

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

RS-232 Loop Back Purpose:

Use the RS-232 Loop Back test to verify that the hardware for the RS-232 port is functioning correctly. Note: The RS-232 port will be available in a future model of the TRAKKER 2425 terminal.

Where Available: Hardware Diagnostics menu Sample Screen:

RS-232

LOOP

BACK

RECEIVING

/CTS 0

[Esc]

Exit

242XU.144

Definition:

The RS-232 test begins immediately. If the RS-232 hardware is functioning correctly, the terminal displays WAITING and then RECEIVING. If there is a problem, an error message appears. The status information on the screen is updated every 500 ms. Note: Once the RS-232 port is available on a future model on the T2425 terminal, you would contact your local Intermec service representative to report an error found during this test.

6-52