For the Intermec 2425

Page 211

HelvC NugFont

Co d e 39 Troubleshooting

6

Bar Code Labels Will Not Scan If you cannot scan bar code labels or you are having problems with the scan module, check these possible problems: Problem

Solution

A scan module is not installed.

Make sure a scan module is installed correctly. You must install either a module for cabled scanners or a standard range scan module before you can use the terminal.

The terminal is turned off.

Make sure the terminal is turned on. Press terminal.

You cannot see a red beam of light from the standard range scan module when you press the Scan button and aim the scanner at a bar code label.

There are two possible problems:

q to turn on the

• You may be too far away from the bar code label. Try moving closer to the bar code label and scan it again. • You may be scanning the bar code label “straight on.” Try changing the scanning angle until the laser beam is the brightest. This is the best scanning angle. You can test the effective range of the scanner. Move within 2 feet of a wall and test the scanner. You need to be within the scanning range to scan bar code labels. For help on scanning distances, see “Physical and Environmental Specifications” in Appendix A.

Warning Do not look directly into the window area or at a reflection of the laser beam while the laser is scanning. Long-term exposure to the laser beam can damage your vision. Advertissement Ne regardez pas directement la réflexion d’un rayon laser ou dans la fenêtre du laser lorsque celui-ci est en opération. Si vous regardez trop longtemps un rayon laser, cela peut endommager votre vue. An input device is not attached to the module for cabled scanners.

Make sure an input device, such as a 1550 laser scanner, is attached correctly to the module for cabled scanners. You must install an input device before scanning bar code labels.

6-23

Page 212

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Bar Code Labels Will Not Scan (continued) Problem

Solution

You have an input device attached to the module for cabled scanners and cannot read any bar code labels.

You may not be using an input device that is supported with the module for cabled scanners. Make sure you are using one of the supported input devices: • • • • •

Intermec 126X and 127X wands Intermec 146X CCD scanners Intermec 151x, 1545, and 155x laser scanners JANUS™ 7010 hand-held imager Compatible Symbol scanners (reverse polarity enabled)

You must use an interface cable to connect the input device to the module. If you are using the J7010 imager, you need to use a wedge interface cable (P/N 062168) and set the Cable ID parameter on the J7010 to the “Force 97xx Wedge” option. For help, see the TRAKKER 2400 Series Module for Cabled Scanners Instruction Sheet (P/N 064219-001). The scan module or input device will not read the bar code label.

Try one of these solutions: • Make sure you aim the scanner beam so it crosses the entire label in one pass. • The angle you are scanning the bar code label may not be working well, or you may be scanning the label “straight on.” Try scanning the bar code label again, but vary the scanning angle. • The bar code label print quality may be poor or unreadable. To check the quality of the bar code label, try scanning a bar code label that you know scans. Compare the two bar code labels to see if the bar code quality is too low. You may need to replace the label that you cannot scan. • Make sure the bar code symbology you are scanning is enabled. Use the TRAKKER 2400 Menu System to check the symbologies. On the Symbologies Menu, each symbology that is enabled has an asterisk (*) next to the name of the symbology. If your bar code symbology is disabled, enable it and then try scanning the bar code label again.

6-24

Page 213

HelvC NugFont

Co d e 39 Troubleshooting

6

Bar Code Labels Will Not Scan (continued) Problem

Solution

The input device connected to the module for cabled scanners does not appear to work well or read bar code labels very quickly.

Try setting the Scanner Selection command to the specific input device you have attached. Check the bar code symbologies you have enabled on the terminal. Enable only the symbologies that you are using.

The standard range scan module does not read the bar code labels quickly, or the scanning beam seems to be faint or obscured.

The standard range scan module window may be dirty. Clean the scanning window of the scan module with a solution of ammonia and water. Wipe dry. Do not allow abrasive material to touch the window.

When you press the Scan button, the scanner LEDs at the top of the keypad do not light up.

Move within 2 feet of a wall and press the Scan button again. Make sure the scan module emits the red laser beam. If the LEDs do not light, there may be a problem with them. For help, contact your local Intermec service representative. If the laser beam does not turn on, check the other problems in this section for a possible solution.

When you release the Scan button, the scanner LEDs at the top of the keypad do not turn off.

The scanner LEDs will remain on if you configure the terminal to use edge triggering. If you configure the terminal for level triggering and the scanner LEDs remain on, there may be a problem with the LEDs. Press the Scan button again without scanning a bar code label. If the LEDs are still on, contact your local Intermec service representative.

6-25

Page 214

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Guidelines for Managing Batteries Follow these guidelines to manage the terminal batteries, prevent problems, and preserve battery power: Main Battery Pack

• ALWAYS turn off the terminal BEFORE you remove the main battery pack. • ALWAYS keep a charged or partially charged main battery pack in the terminal. • Keep a spare, charged battery pack on hand. • If the Battery icon appears and remains on solid, you have a low main battery pack, replace or charge the battery pack as soon as possible. • When you remove a low main battery pack from the terminal, recharge the battery pack you just removed. • If the terminal turns off due to a low main battery pack, do not turn on the terminal. Replace or charge the main battery pack before you continue using the terminal. • Use the battery charger to charge the main battery pack. Charge the main battery pack for a minimum of 2 hours to make sure the battery pack is fully charged.

Backup Battery

• If you have a low backup battery, turn off the terminal. Insert a fully charged main battery pack. The main battery pack will fully charge the backup battery in approximately 18 hours. • ALWAYS turn off the terminal BEFORE you remove the backup battery.

Storing the Terminal

6-26

• If you are going to store the terminal for less than 2 weeks, keep both batteries installed in the terminal. Insert a fully charged main battery pack before you store the terminal.

Page 215

HelvC NugFont

Co d e 39 Troubleshooting

6

Storing the Terminal (continued)

• If you are going to store the terminal for more than 2 weeks, save your data and end your TE or screen mapping session to minimize the risk of data loss. Remove both the main battery pack and the backup battery from the terminal.

Cold Temperatures (Using the terminal in sub-freezing environments)

• If you use the terminal in a cold temperature environment, battery life will be reduced. Battery life depends on temperature, battery model, input device, age of the battery pack, your usage, and duty cycle factors. If you use the terminal for extended periods of time in sub-freezing environments, you may need to change the battery pack more often. • Do not store the terminal in a cold temperature environment. When you are not using the terminal, keep it in a warmer area to make sure the battery chargers will continue operating. • If the Battery icon blinks, the backup battery charge is low. Move the terminal to a warmer environment to charge the backup battery. The backup battery charger operates between 32°F and 104°F (0°C and 40°C). If you are using the terminal in an area outside this temperature range, the backup battery will not charge. • Store the battery chargers and spare batteries in a warm (office) environment to assure the most efficient operation. • Charge the main battery pack in an area or room where the temperature is above freezing. • If you have been using the terminal in a cold temperature environment and need to replace or charge either battery, let the batteries warm up for a half hour before you charge them.

6-27

Page 216

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Booting and Resetting the Terminal You seldom need to boot or reset the TRAKKER 2425 terminal. When you boot the terminal, it runs through power-on self test (POST) to test each major subsystem. The terminal uses the configuration currently saved in flash memory. Once the terminal is finished booting, your TE application or screen mapping application appears on the display. You only reset the terminal when the terminal or an application are locked up and will not respond to any key sequences. The terminal also boots and resets after a firmware upgrade or if you remove both batteries. The next instructions explain how you boot and reset the terminal.

Booting the Terminal You can boot the terminal using these two methods: • Configure the q key to boot the terminal when you turn on the terminal.

• Use the Boot Menu.

Booting the Terminal on Resume q q

When you press to turn off the terminal, it turns off and goes into Suspend mode. When you press to turn on the terminal, it resumes or boots depending on the terminal configuration. There are two ways to configure the configuration command:

q key using the Resume Execution q

Resume Execution Not Allowed Configures the terminal to boot and restart your TE application or screen mapping application each time you press to turn on the terminal. Use this option if you want to restart your application every time you turn on the terminal.

Resume Execution Allowed Configures the terminal to resume exactly where it was when you turned off the terminal. Use this option to resume working each time you turn on the terminal. You can configure the Resume Execution command by using the TRAKKER 2400 Menu System or by scanning these bar code labels. For help, see Chapter 3, “Configuring the Terminal,” or “Resume Execution” in Chapter 8.

6-28

Page 217

HelvC NugFont

Co d e 39 Troubleshooting

Resume Execution Not Allowed

*$+ER0*

6

Resume Execution Allowed

*$+ER1*

*$+ER0*

*$+ER1*

Using the Boot Menu The Boot menu appears after you: • remove both batteries, install them again, and turn on the terminal. • upgrade the firmware. • reset the terminal.

BOOT MENU b - Boot System l - Run Loader q - Power Down

POWER DOWN IN 60 SEC 242XU.104

The Boot Menu contains these commands:

B

Boot System If you did remove the batteries, make sure you install a charged main battery pack or the terminal will not turn on. Press to boot the terminal. Once the terminal is finished booting, your TE application or screen mapping application appears on the display.

L

Run Loader Press to load the terminal firmware. To upgrade or load the firmware, you should use the Firmware Upgrade option in the TRAKKER 2400 Menu System. For help, see “Upgrading the Firmware” in Chapter 3.

Q

Power Down Press to turn off the terminal. When you turn on the terminal, the Boot Menu screen appears if POST passes.

6-29

Page 218

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Resetting the Terminal If the terminal or application is locked up and the terminal will not respond to any key sequences, you can reset the terminal. Before you reset the terminal, try the following in order: • Press q to turn off the terminal.

• Scan the Reset Firmware label to restart the firmware and application. Reset

*-.* *-.*

If the terminal or application still will not respond, reset the terminal. To reset the terminal 1. Press the 2. Press

) - ; - q keys in sequence. The terminal turns off.

q to turn on the terminal. The Boot Menu appears. BOOT MENU b - Boot System l - Run Loader q - Power Down

POWER DOWN IN 60 SEC 242XU.104 q

) ;

Note: If the terminal returns to the exact same screen, the reset sequence did not work. Repeat Step 1. Make sure you press the key just after the and .

B to boot the terminal. Once the terminal has finished booting, 3. Press your TE application or screen mapping application appears. If the terminal still will not reset or boot, try loading the firmware. For help, contact your local Intermec service representative.

6-30

Page 219

HelvC NugFont

Co d e 39 Troubleshooting

6

Maintaining and Cleaning the Terminal The TRAKKER 2425 terminal is built for use in a rugged, industrial working environment. You may need to perform these minor maintenance tasks to keep the terminal in good working order: • Replace the antenna • Clean the display • Clean the standard range scan module window The antenna is one of the few exposed parts that may be damaged while you use the terminal. You can order and replace the antenna using the instructions in this section. If you do have problems with other mechanical parts, contact your local Intermec service representative for help. Clean the scan module window and display as often as needed for the environment in which you are using the terminal. Each procedure is described in detail in this section. To order replacement parts, contact your local Intermec service representative or contact Intermec at: Intermec Corporation 6001 36th Ave. West P.O. Box 4280 Everett, Washington 98203-9280 Telephone: 1-206-348-2600

6-31

Page 220

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Replacing the Antenna If your antenna is damaged, you can replace it. To replace the antenna, you need these items: • 2.4 GHz SMB antenna (Part No. 063825) • Retaining ring (Part No. 064101) • Small straight-slot screwdriver To replace the antenna 1. Rotate the antenna to line up the alignment marks on the connector end of the antenna with the alignment marks on the terminal antenna connector. 2. Insert the straight-slot screwdriver into the retaining ring opening so that the screwdriver is in the retaining ring slot. Retaining ring opening

Antenna (must be in this position)

242XU.147

3. Pry the retaining ring up out of the opening and remove it. 4. Pull the antenna off the antenna connector on the terminal.

6-32