Page 201

HelvC NugFont

Co d e 39 Troubleshooting

6

Terminal Will Not Communicate With Network Devices If you cannot get the terminal to communicate with other devices in the 2.4 GHz network, check these possible problems: Problem

Solution

The Radio icon on the terminal display remains on.

Either the Network Activate command is disabled or there is a problem with the radio card and it is turned off. Make sure the Network Activate command is enabled. Use the TRAKKER 2400 Menu System or scan the Network Activate command to enable the 2.4 GHz network and turn on the radio. For help, see “Network Activate” in Chapter 8. If the network is enabled and the Radio icon remains on, there may be a problem with the radio card. For help, contact your local Intermec service representative.

The Connect icon is not lit on the terminal display.

The terminal is not connected to the 0100 Access Point. Make sure the access point is turned on and operating. You may also be using the terminal out of the RF range of an access point. Try moving closer to an access point to re-establish communications. Make sure the terminal is configured correctly for your network. To communicate with the access point, the RF domain and RF security ID on the terminal must match the values set for all access points the terminal may communicate with. For help, see “Installing and Configuring the Terminal” in Chapter 4.

The Connect icon blinks on the terminal display.

*

The terminal is trying to establish communications with the Model 200 Controller. You may need to check the terminal configuration, or make sure the controller is running and data collection is started. Make sure the access point is still turned on. Each device in the 2.4 GHz network must have a valid IP address. The IP addresses set on the terminal must match the addresses configured on the controller. For help, see “Installing and Configuring the Terminal” in Chapter 4.

6-13

Page 202

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Terminal Will Not Communicate With Network Devices (continued) Problem

Solution

The terminal is connected to the host computer and you move to a new site to collect data. The Connect icon was on and now begins to blink or turns off.

You may have gone out of range of an access point. Try moving closer to an access point or to a different location to re-establish communications. Once you are in range again, the Connect icon will appear and remain on. Any data you collected while you were out of range will be transmitted over the network.

* The Connect icon blinks on the terminal display and you see this message: Unable to connect to controller. Error 102. Unable to establish connection to host. Session ended.

The Connect icon remains on, but the host computer is not receiving any data from the terminal.

* The Connect icon remains on, but you cannot establish a terminal emulation session with the host computer.

*

6-14

The terminal is connected to the 0100 Access Point, but is trying to establish communications with the Model 200 Controller and the host computer. Make sure the terminal is correctly configured for your network. Make sure the controller is configured and running. Make sure the host computer is configured and running. If you have configured the network correctly, try restarting the controller to establish communications. You can also try resetting the terminal. For help resetting the terminal, see “Booting and Resetting the Terminal” later in this chapter. There may have a problem with the connection between the Model 200 Controller and the host computer. Check with your network administrator or use the Model 200 Controller System Manual to troubleshoot any potential problems on the controller. There may be a problem with the host computer, or the connection between the Model 200 Controller and the host computer. Check with your network administrator to make sure the host computer is running and allowing users to login to the system.

Page 203

HelvC NugFont

Co d e 39 Troubleshooting

6

Problems Using Terminal Emulation Applications There are two types of error messages that you may see while running the 3270 or 5250 terminal emulation application on the terminal: • Recoverable error • Non-recoverable error Recoverable errors display in the status line on the bottom line of the terminal display. If the status line option is not currently selected, the status line will appear if there is a recoverable error. A non-recoverable error appears directly on your display and your TE session ends. You must follow the instructions on the terminal display to continue with your session. If the Model 200 Controller detects an error and ends the session, you will see a controller error message on the terminal display. Record this error message and pass it on to your network administrator or contact your local Intermec service representative. The 3270, 5250, and VTXXX/ANSI terminal emulation applications have an error handling routine that detects local editing errors and command handling errors. If you have a problem while running your TE application, check these possible problems: Note: Many of the error messages in the next table only apply when running the 5250 TE application. Error Message

Solution

Attn Not Processed (5250 error)

The host computer was unable to process your Attention to reset the terminal and try again later. request. Press

Digit Only (5250 error)

You have entered an invalid character in a digit only (numeric) field. Reenter a valid character for this type of field.

DUP Field Required (5250 error)

You have pressed a DUP key in a field that does not have the DUP bit enabled. Enter a valid command for this type of field.

Field minus invalid (5250 error)

You have pressed the Field- key in a non-numeric field. Use the Field Exit or Field+ key.

Field not in Field Format Table (5250 error)

The cursor is not positioned correctly in a data input field. Position the cursor correctly and try again.

(d

6-15

Page 204

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Problems Using Terminal Emulation Applications (continued) Error Message

Solution

FM Field Required (5250 error)

You have pressed a Field Mark key in a field that does not have the DUP bit enabled. Enter a valid command for this type of field.

Function not implemented (5250 error)

You have pressed an unsupported function key or entered an invalid key sequence. Try the function again using the correct key sequence.

Help Not Processed (5250 error)

The host computer was unable to process your Help request. to reset the terminal and try again. Press

Invalid control sequence

You have pressed an unsupported function key or entered an invalid key sequence. Reenter a valid key sequence.

Mandatory field! (5250 error)

You have attempted to bypass a mandatory data entry field using a Field+, Field-, or Field Exit key. Enter data in the field.

Monocase Only (5250 error)

You have entered an invalid character in a monocase only field. Reenter a valid character for this type of field.

No more room for insert

You have entered more characters than allowed in a field. to reset the terminal. Enter your data again using Press fewer characters.

Numeric Only

You have entered an invalid character in a numeric only field. Reenter a valid character for this type of field.

Parameter error. (5250 error)

The command received from the host computer contained an invalid parameter. Try to establish a host connection later by selecting Exit Config from the TE Configuration menu.

Protected Field

You are attempting to enter data in a protected region of the to reset the terminal. screen. Press

Roll Down Not Processed (5250 error)

The host computer was unable to process your Roll Down to reset the terminal and try again. request. Press

6-16

(d

(d

(d

(d

Page 205

HelvC NugFont

Co d e 39 Troubleshooting

6

Problems Using Terminal Emulation Applications (continued) Error Message

Solution

Roll Up Not Processed (5250 error)

The host computer was unable to process your Roll Up to reset the terminal and try again. request. Press

Session ended.

This message indicates a fatal error. Record the controller primary and secondary return codes and contact your network administrator. Wait a few minutes and try to connect again by selecting Exit Config from the TE Configuration menu.

Signed Numeric Only (5250 error)

You have entered an invalid character in a signed numeric field. Reenter a valid character for this type of field.

SysRq Not Processed (5250 error)

The host computer was unable to process your System to reset the terminal and try again. Request. Press

(d

(d

6-17

Page 206

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Problems Using the Screen Mapping Application There are three types of errors that you may see while running the screen mapping application on the terminal: • Initialization errors that occur while trying to start the screen mapping application, download the template, or loading a screen. • Communications errors that occur while trying to communicate with the Model 200 Controller. • Data entry errors that occur while entering data in the fields on a screen. If you have a problem while using your screen mapping application, check these possible initialization, communications, or data entry problems.

Screen Mapping Initialization Errors Problem

Solution

Restart T2400.

The screen mapping application did not start correctly. Scan this bar code label to reset the firmware and restart the application: Reset Firmware

*-.* *-.* Error Reading Template File.

You are trying to download the template file from the Model 200 Controller and a file error occurred. Make sure you enter a valid template name that is currently stored on the correct directory on the controller. Try requesting or downloading the template again. For help, see the Model 200 Controller System Manual.

Screen must have one input field defined.

The screen you selected has not been defined correctly. An input screen must have at least one input field defined. You need to fix the template and the screen definition on the controller and download a new template.

Required Fields Not Complete.

You skipped at least one required field. You must enter data in each required field on the screen. Make sure you have entered data in every required field to continue.

6-18

Page 207

HelvC NugFont

Co d e 39 Troubleshooting

6

Screen Mapping Initialization Errors (continued) Problem

Solution

Error building list from template file.

The template file was downloaded from the controller, but there was a problem building the list of screens. The template file on the terminal is corrupted. Try requesting or downloading the template again. For help, see “Requesting a New Template” in Chapter 5.

No menu items defined in Template.

The template file was downloaded from the controller, but either no menu items were defined in the template or there is a problem reading the template. The template file on the terminal is corrupted. Try requesting or downloading the template again. For help, see “Requesting a New Template” in Chapter 5.

Template file error reading menu.

The template file was downloaded from the controller, but there was a problem reading the menu. The template file on the terminal is corrupted. Try requesting or downloading the template again. For help, see “Requesting a New Template” in Chapter 5.

Could not open Template file.

The template file was downloaded from the controller, but the terminal could not open the template file. The template file on the terminal is corrupted. Try requesting or downloading the template again. For help, see “Requesting a New Template” in Chapter 5.

There are no Screen items defined in Template.

The template file was downloaded from the controller, but no screen items are defined in the template. Check the template on the controller and make sure you have defined screens. The template file on the terminal is corrupted. Try requesting or downloading the template again. For help, see “Requesting a New Template” in Chapter 5.

Error reading Screens in Template file.

The template file was downloaded from the controller, but there was a problem reading the screens in the template. The template file on the terminal is corrupted. Try requesting or downloading the template again. For help, see “Requesting a New Template” in Chapter 5.

6-19

Page 208

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Screen Mapping Initialization Errors (continued) Problem

Solution

Link List error, Program exiting.

The template file was downloaded from the controller, but there was a problem. The template file on the terminal is corrupted. Try requesting or downloading the template again. For help, see “Requesting a New Template” in Chapter 5.

Build screen error.

The template file was downloaded from the controller, but there was a problem building the screens. The template file on the terminal is corrupted. Try requesting or downloading the template again. For help, see “Requesting a New Template” in Chapter 5.

Error on read.

The template file was downloaded from the controller, but there was a problem reading the file. The template file on the terminal is corrupted. Try requesting or downloading the template again. For help, see “Requesting a New Template” in Chapter 5.

Screen Mapping Communications Errors Problem

Solution

Transaction Buffer Full.

The buffer holding transactions to be sent to the controller is full. Stop collecting data with this terminal. Make sure the terminal is communicating with the Model 200 Controller and let the terminal send all the transactions in the buffer before you continue collecting data.

Sending Buffer Transactions.

This is an information message to tell you that buffered transactions are now being sent to the controller. You can begin collecting data again once the message clears.

Transaction Aborted.

The transaction just sent to the controller was not received. Try sending the transaction again.

6-20

Page 209

HelvC NugFont

Co d e 39 Troubleshooting

6

Screen Mapping Communications Errors (continued) Problem

Solution

Transmit Error XX, press Enter.

There is an error transmitting data to the controller. XX represents the status code error. Note the error code listed in the message and contact your local Intermec service to continue. representative for help. Press

;

Receive Error XX, press Enter.

There is an error receiving data from the controller. XX represents the status code error. Note the error code listed in the message and contact your local Intermec service to continue. representative for help. Press

;

Shutting down.

The Model 200 Controller is shutting down. You may continue collecting data and buffer the transactions in the terminal until the controller starts again, or stop collecting data with the terminal.

Controller Shutdown.

The Model 200 Controller has shut down. You may continue collecting data and buffer the transactions in the terminal until the controller starts again, or stop collecting data with the terminal.

Screen Mapping Data Entry Errors Problem

Solution

Minimum length error.

You entered too few characters in the field. Enter your data again using the required number of characters.

This field is required.

You cannot skip a required field. Enter data in the field to continue.

Prefix error.

The prefix character entered is incorrect. Enter your data again using a valid prefix.

Bad Data.

The data entered did not pass the input test defined for this field. Enter your data again.

6-21

Page 210

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Screen Mapping Data Entry Errors (continued) Problem

Solution

Validation File Missing.

The validation file used for the screen is not stored on the terminal. You can download the validation file from the Model 200 Controller or request the file from the terminal. For help, see “Loading a Validation File” in Chapter 5.

Range Error.

The data entered is out of the range defined for this field. Enter your data again.

Bad Picture Match.

The data entered does not match the picture defined for this input field. Enter your data again.

Numeric Only.

The data entered was not numeric and this is a numeric field. Enter your data again using only numeric data.

Hour Greater Than 23.

You are entering data in a Time field and entered an invalid hour. Enter the time again using an hour from 0 to 23.

Minutes Greater Than 59.

You are entering data in a Time field and entered invalid minutes. Enter the time again using minutes from 0 to 59.

Seconds Greater Than 59.

You are entering data in a Time field and entered invalid seconds. Enter the time again using seconds from 0 to 59.

Days Error.

You are entering data in a Date field and entered an invalid day. Enter the date again using a valid day for the month.

Month Error.

You are entering data in a Date field and entered an invalid month. Enter the date again with a valid month from 1 to 12.

Year Error.

You are entering data in a Date field and entered an invalid year. Enter the date again with a valid year.

Input Length Error.

The data entered exceeded the length defined for this field. Enter your data again.

6-22