Co d e 39 Troubleshooting

6

This chapter lists the problems you may have while using the terminal and gives some possible solutions. You will also find instructions that explain how to replace the antenna, clean parts of the terminal, and run diagnostic tests.

How to Use This Chapter If you have any problems with the TRAKKER 2425 terminal, use this table as a guide to find the problem and solution in this chapter: Problem

See This Section to Find a Solution

Page

Display is blank

“Terminal Will Not Turn On”

6-5

Terminal locked up Message displayed

“Problems While Operating the Terminal”

6-6

Configuring the terminal

“Problems While Configuring the Terminal”

6-10

Communications error

“Terminal Will Not Communicate With Network Devices”

6-13

TE application error

“Problems Using Terminal Emulation Applications”

6-15

Screen mapping application error

“Problems Using the Screen Mapping Application”

6-18

Scanning labels

“Bar Code Labels Will Not Scan”

6-23

Battery management

“Guidelines for Managing Batteries”

6-26

Boot Menu appears or terminal locked up

“Booting and Resetting the Terminal”

6-28

Antenna is damaged

“Maintaining and Cleaning the Terminal”

6-31

Diagnostics and troubleshooting

“Running Diagnostics”

6-35

6-3

Page 192

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Finding and Solving Problems If you have a problem while configuring or using the terminal, use the tables in this section to find a solution. For easy reference, problems are grouped into these topics: • Terminal Will Not Turn On • Problems While Operating the Terminal • Problems While Configuring the Terminal • Terminal Will Not Communicate With Network Devices • Problems Using Terminal Emulation Applications • Problems Using the Screen Mapping Application • Bar Code Labels Will Not Scan • Guidelines for Managing Batteries

Caution There are no user-serviceable parts inside the terminal. Opening the unit will void the warranty and may cause damage to the internal components. Conseil La terminal ne contient pas de pièces révisibles par l’utilisateur. Le fait d’ouvrir l’unité annule la garantie et peut endommager les pièces internes. If you send the terminal in for service, it is your responsibility to save the terminal data and configuration. Intermec is responsible only for ensuring that the keypad and other hardware features match the original configuration when repairing or replacing your terminal.

6-4

Page 193

HelvC NugFont

Co d e 39 Troubleshooting

6

Terminal Will Not Turn On q

If you press to turn on the TRAKKER 2425 terminal and nothing happens, check the terminal for these possible problems. For more help, see Chapter 1, “Getting Started.” Problem

Solution

A scan module is not installed.

Make sure a scan module is installed correctly. You must install either a module for cabled scanners or a standard range scan module before you can turn on the terminal.

A main battery pack is not installed. You see the Battery icon on the top line of the display.

Remove the battery door on the terminal and make sure the main lithium-ion battery pack is installed correctly. Slide the battery pack toward the top of the terminal to lock the battery pack into the connectors.

The main battery pack is not charged. You see the Battery icon on the top line of the display.

The main battery pack may be discharged. Replace the battery pack with a spare charged battery pack, or charge the battery pack and try again.

6-5

Page 194

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Problems While Operating the Terminal If you are operating the TRAKKER 2425 terminal and have trouble, check these possible problems and solutions: Problem

Solution

You scan a reader command, such as Backlight On, and nothing happens.

The reader commands are disabled. Scan the Enable Override command shown here to temporarily enable all of the reader commands. You can also enable or disable reader commands with the TRAKKER 2400 Menu System. For help, see “Command Processing” in Chapter 8. When you are finished, remember to disable the override so that your data is not interpreted as a command. Enable Override

*$+DC3* *$+DC3* You scan a valid bar code label to enter data for your application. The data decoded by the scan module does not match the data encoded in the bar code label.

The terminal may have decoded the bar code label in a symbology other than the label’s actual symbology. Try scanning the bar code label again. Make sure you scan the entire label.

You want to set the terminal back to the default configuration to start over configuring the terminal.

Scan this bar code label:

To operate the terminal quickly and efficiently, you should enable only the bar code symbologies that you are going to scan. If you enable multiple symbologies, the terminal may on rare occasions decode a bar code according to the wrong symbology and produce erroneous results.

Default Configuration

*.+* *.+*

Or, use the TRAKKER 2400 Menu System and follow the instructions in “Restoring the Terminal’s Default Configuration” in Chapter 3. Note: After you load the default configuration, you may need to set the primary network communications parameters to communicate with other devices in the 2.4 GHz network.

6-6

Page 195

HelvC NugFont

6

Co d e 39 Troubleshooting

Problems While Operating the Terminal (continued) Problem

Solution

You cannot scan bar code labels with the standard range scan module or the module for cabled scanners.

See “Bar Code Labels Will Not Scan” later in this chapter.

The terminal appears to be locked up and you cannot enter data.

Try these possible solutions: • Wait at least 10 seconds and try again. If the terminal is still connecting to the controller, the terminal ignores any input from the keypad or scanner. Make sure the Connect icon appears and remains on before continuing. • Scan any bar code label to see if the terminal responds.

q to turn off the terminal. If it turns off, press • Press to turn on the terminal. You can continue working.

q

• If the terminal will not turn off, press these keys in sequence to reset the terminal:

)-;-q q

The terminal turns off. Press to turn on the terminal. It boots all the systems, clears RAM memory, and starts your application.

q

Note: If the terminal does not boot when you press , you did not press the reset sequence correctly. Press and hold the and keys first, then press .

) ;

q

• Remove the main battery pack and disconnect the backup battery. Let the terminal sit for 1 minute. Install the battery pack and connect the backup battery. Press to turn on the terminal.

q

• If you keep returning to the Boot Menu, try loading the firmware. For help, see “Upgrading the Firmware” in Chapter 3. • If the terminal will not boot or reset, contact your local Intermec service representative for help.

6-7

Page 196

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Problems While Operating the Terminal (continued) Problem

Solution

The terminal is booting and you see a message that POST failed.

The screen displays the system that failed POST. Report the error message to your supervisor.

d B to exit the error message. The Boot Menu appears. Press Press to boot the terminal. Your application appears on the display. If the terminal still will not boot, contact your local Intermec service representative for help. The terminal displays the Boot Menu.

You will see the Boot Menu in these two situations: • You remove both batteries at the same time. Once you replace the batteries and turn on the terminal, the Boot Menu appears. Press to boot the terminal and continue working.

B

B

• You just finished upgrading the firmware on the terminal and POST failed. Press to boot the terminal. Report the problem to your supervisor. For help on the Boot Menu, see “Booting and Resetting the Terminal” later in this chapter. You insert a main battery pack. The terminal will not turn on and the Battery icon is not displayed.

The main battery is completely discharged of power. The terminal does not even register enough power to identify a main battery pack and display the Battery icon. Replace the main battery pack with a spare charged battery pack, or charge the battery pack.

You see both these symptoms:

The main battery pack charge is low. You have a few minutes of power left. Replace the main battery pack with a spare charged battery pack, or charge the battery pack.

• The Battery icon remains on solid. • The terminal beeps once every 15 seconds.

6-8

Page 197

HelvC NugFont

Co d e 39 Troubleshooting

6

Problems While Operating the Terminal (continued) Problem

Solution

The Battery icon blinks on the top line of the terminal display.

The backup battery charge is low, or the backup battery is not connected. Make sure the backup battery wire connectors are firmly locked together. Check the wires leading into the backup battery and into the bottom case for any damage or loose connections.

Note: The terminal is not beeping.

Make sure a main battery pack is installed and connected. Turn off the terminal. Let the main battery pack charge the backup battery. The backup battery will be fully charged in approximately 18 hours. If you have been using the terminal in a cold temperature environment, move the terminal to a warmer environment to charge the backup battery. If the backup battery will not charge, you may need to replace it. For help, contact your local Intermec service representative. You see both these symptoms: • The Battery icon blinks. • The terminal beeps once every 15 seconds.

The main battery pack charge and the backup battery charge are both low. Immediately turn off the terminal. Replace the main battery pack with a spare charged battery pack. Let the main battery pack charge the backup battery. The backup battery will be fully charged in approximately 18 hours. If you have been using the terminal in a cold temperature environment, move the terminal to a warmer environment to charge the backup battery. If the backup battery will not charge, you may need to replace it. For help, contact your local Intermec service representative.

6-9

Page 198

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Problems While Configuring the Terminal You can configure the terminal by using the TRAKKER 2400 Menu System or by scanning configuration commands. If you have problems configuring the terminal, check these possible problems and solutions. Problem

Solution

You see this error message when exiting the Configuration Menu:

The 2.4 GHz network is enabled and there is a problem with the network configuration. There are four possible problems to check and fix in the Communications Menu:

Communications Menu configuration error. Configuration was not updated.

• The terminal IP address or the controller IP address is set to 0.x.xx.x or 127.x.x.x. These are invalid addresses. Set a valid IP address for the terminal and/or controller. • The terminal IP address and the controller IP address are both set to the same address. Set a valid IP address for the terminal and controller. • The terminal and controller are on different networks, but the terminal IP address and the default router address are both set to the same address. Set a valid IP address for the terminal and the default router. • The terminal and controller are on different networks, and the terminal is not on the same network as the default router. When the terminal is on a different IP subnetwork from the controller, you must set the Default Router and Subnet Mask commands. Set a valid IP address for terminal, controller, and default router. For help, see “Installing and Configuring the Terminal” in Chapter 4. If you cannot fix the addressing problem, check with your network administrator to get the IP address assigned to the terminal and the controller.

You configure the RF security ID and the changes do not appear to be saved.

6-10

You can only set the RF security ID with the 2.4 GHz network enabled. The Network Activate configuration command must be configured to 2.4 GHz RF Network before you can save any changes to the RF security ID command.

Page 199

HelvC NugFont

Co d e 39 Troubleshooting

6

Problems While Configuring the Terminal (continued) Problem

Solution

You see this error message when exiting the Configuration Menu:

The two-character name (syntax) of the configuration command that failed is listed on the first line of the error message. For example, you may see this message:

Commandname command failed.

SS command failed.

Remainder of configuration not updated.

There may be a problem with the configuration due to a change made with the Scanner Selection (SS) command. Check the command listed in the message. To find the command, use the “Configuration Commands by Syntax” table in Appendix A. Make sure the command is set correctly for the options and network you are using with the terminal. For help, see Chapter 8, “Configuration Command Reference.”

You scan a configuration command, such as Keypad Caps Lock, and you hear three low beeps.

If you are working in the TRAKKER 2400 Menu System, you cannot scan configuration commands. Use the Configuration Menu to change the terminal’s configuration, or exit the menu system to scan configuration commands.

You scan a configuration command, such as Keypad Caps Lock, and nothing happens.

There are two possible solutions: • You may have one or more reader commands disabled, such as Change Configuration, so that you cannot change the configuration. Enable all of the reader commands and try again. • The terminal may be waiting for another command to complete the configuration change. If you started by scanning the Enter Accumulate command, you must finish the command by scanning the Exit Accumulate command. For help, see Chapter 8, “Configuration Command Reference.” Scan the Enable Override to temporarily enable all of the reader commands. When you are finished, remember to disable the override so that your data is not interpreted as a command. Enable Override

*$+DC3* *$+DC3*

6-11

Page 200

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Problems While Configuring the Terminal (continued) Problem

Solution

You scan a configuration command to set one of these parameters and hear three low beeps:

If the Network Activate command is enabled (2.4 GHz network enabled) and you are configuring the terminal, these addresses must define a valid network configuration. For example, an invalid network configuration would be a controller IP address set to 0.0.0.0 with the network enabled.

• • • •

Controller IP Address Terminal IP Address Default Router Network Activate

To set these four parameters, follow these steps: 1. Disable the Network Activate (NA) configuration command. 2. Set the terminal IP address and the controller IP address. 3. Set the default router address (if necessary). 4. Enable the Network Activate command. You can change an IP address with the network enabled as long as it still defines a valid network configuration.

6-12