Page 161

HelvC NugFont

Co d e 39

2. Choose Configure TE and press appears.

TE

Running Applications

5

;. The TE Configuration menu

CONFIGURATION

Terminal Communications Viewport Exit Config Help

_` Select item [Enter] Next [F1] Help [Esc] Exit 242XU.019

;

[ {

3. Press or to highlight the function you want to configure and press . To exit, see “Exiting the TE Configuration Menu” later in this chapter. The Terminal screen contains this option:

TERMINAL Text Size Regular

OK

Height

CANCEL 242XU.020

Text Size Selects the size of text the T2425 terminal displays on the terminal screen. Options are regular height (normal characters) and double height (double high text).

5-9

Page 162

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual THelvC NugFont

Co d e 39

The Communications screen contains this option:

COMMUNICATIONS Host Name IMSYSD

OK

CANCEL 242XU.021

Host Name Enter the name of the host to which you want the terminal to connect. You can enter a host name that is up to 13 characters long. Note: If you have linked a terminal with a host name on the Model 200 Controller, you do not need to enter a host name in this screen. If you have not linked a terminal with a host name on the controller, you must enter a host name for this parameter. The host name in this screen must match a host name in the list of available hosts defined on the controller. The Viewport screen contains these options

VIEWPORT Viewport Mode Follow Side Boundary 1 Side Jump 10 Vertical Boundary 1 Vertical Jump 8 OK

CANCEL 242XU.022

5-10

Page 163

HelvC NugFont

Viewport Mode

Co d e 39

Running Applications

5

Select one of these viewport movement modes:

Follow

Enables viewport Follow Cursor mode.

Center

Enables viewport Center mode. The viewport always centers around the cursor.

Disable

Disables viewport movement. You must manually move the cursor to each field in the screen.

You can set these parameters for Follow Cursor mode only: Side Boundary The viewport moves when the cursor is this number of characters from the right or left side boundary. You can enter a number from 1 to 10. Side Jump The number of characters the viewport moves right or left when you reach a horizontal boundary. You can enter a number from 1 to 10. Vertical Boundary The viewport moves when the cursor is this number of characters from the top or bottom boundary. You can enter a number from 1 to 10. Vertical Jump The number of characters the terminal moves up or down when you reach a vertical boundary. You can enter a number from 1 to 10.

5-11

Page 164

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual THelvC NugFont

Co d e 39

Exiting the TE Configuration Menu After entering all configuration parameters, you are prompted to save the new configuration and exit the Configuration menu. You can choose between several options when prompted to save the new configuration. To exit the TE Configuration menu 1. From the TE Configuration menu, choose Exit Config and press Save new configuration screen appears.

Save

;. The new configuration?

Yes

No

CANCEL

242XU.023

;

2. Choose Yes and press if you want to save the TE configuration. Your terminal saves the configuration options to flash memory and the sign on screen appears.

;

Choose No and press if you do not want to save the TE configuration. You exit the TE Configuration menu and the sign on screen appears.

;

Choose Cancel and press to return to the TE Configuration menu. You can continue making changes to the TE configuration

5-12

Page 165

HelvC NugFont

Co d e 39

Running Applications

5

Understanding Status Line Messages TRAKKER 2425 terminals provide a status line when configured as 3270 or 5250 terminals. You will see the status messages on the status line or bottom line of the terminal display. The status messages report the operating status of both the T2425 terminal and the host system. Use

( Q to toggle the status line on and off, or scan this bar code:

Status

*/ESTAT* *%STAT*

You will see screens similar to these:

TE Session Established

Host Processing Data

Sign on User.............. Password.......... Program/procedure. Menu.............. Current Library...

Sign on User.............. Password.......... Program/procedure. Menu.............. Current Library...

TNAPP TNAPP

TNAPP

F

F XSYS

F

LOCK 242XU.024

This table summarizes information you may see in the status line. Status Line Message

Description blank

No activity, ready for operator input.

ERR (5250 only)

The terminal operator pressed an AID key to transmit data to the host. The host did not accept the data and transmitted a Write Error command to the TE application indicating the field where the error occurred. Use the viewport to view the error message and corrective procedure. Press ErrRst to clear this message.

5-13

Page 166

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual THelvC NugFont

Co d e 39

Status Line Messages (continued) Status Line Message

Description

INIT

Terminal is attempting to connect to the server.

INS

Terminal is in Insert mode.

LOCK

Keypad is locked by the host application.

MSGWAIT (5250 only)

A system message is waiting to be read.

PEND

The terminal is connected to the server and is waiting for an active host session.

TNAPP

Terminal is in session with a host application.

TNSVR

Terminal is connected to the server.

F, C, or D

Current Viewport mode of the T2425 terminal. One of these characters is displayed to indicate the Viewport mode status:

XSYS

F

Viewport Follow mode is enabled

C

Viewport Center mode is enabled

D

Viewport movement is disabled

Keypad is disabled and the TE application is waiting for a host response.

Auto-Advancing Through Fields on 5250 TE Screens You can set up your TRAKKER 2425 terminal so that when a user scans data into a field on a 5250 TE screen, a Field Exit command clears the rest of the field, advances to the next field, and triggers an auto-enter field to send an ENTER to the application and submit the data. The user can just scan data and never has to touch the keypad. To set this up, you need to set the Postamble command to the 5250 Field Exit code. However, you cannot use the TRAKKER 2400 Menu System nor scan the value using the Postamble configuration command. These two configuration methods currently do not support the extended ASCII character set, which includes the ASCII equivalents for special 5250 keys such as Field Exit. However, the terminal does support the extended ASCII character set.

5-14

Page 167

HelvC NugFont

Co d e 39

Running Applications

5

You must configure the postamble to the Field Exit’s literal value using the download server on the Model 200 Controller. You can use the download server on the controller to configure one or more terminals in the network. To configure and use Field Exit as a postamble 1. In the download server on the controller, select the terminal or group to which you want to download the Postamble (AE) configuration command. For help on configuring a group of terminals, see the Model 200 Controller System Manual. Note: You can continue running the 5250 TE application on the T2425 while configuration a terminal from the controller. 2. Choose the option to enter a command. 3. Type the string $+AE and then enter the ASCII code 154 by holding down the Alt key while typing 154 on the numeric keypad. You should see an Ü (umlaut) to represent the literal Field Exit code in the edit box, which now shows this command and value: $+AEÜ 4. Choose Download to download the commands and change the runtime configuration of the terminals selected. When you configure the terminal from the controller, the configuration changes are saved in RAM, but not in flash memory. You must use the TRAKKER 2400 Menu System to save the configuration in flash memory. For help, see “Saving Configuration Changes in Flash Memory” in Chapter 3. You can set the postamble or preamble to any character from the extended ASCII character set using these instructions. Find the literal ASCII value and type that value in Step 3 instead of the Field Exit code. To set the preamble, use the syntax $+AD instead of $+AE.

5-15

Page 168

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual THelvC NugFont

Co d e 39

Using VT100/220/320 or ANSI Terminal Emulation Your TRAKKER 2425 terminal contains a special keypad and firmware that provide most of the commands available to emulate a VT100/220/320 or ANSI terminal. You can use your T2425 terminal to: • emulate VT100/220/320 and ANSI keyboards by using the scan module or the keypad. • run host applications using the VT100/220/320 or ANSI terminal emulation features. After you have installed the terminal in your system, you need to learn how to configure and use the terminal emulation application. The next sections cover these topics: • Using the VTXXX/ANSI keypad • Configuring VTXXX/ANSI TE parameters

5-16

Page 169

HelvC NugFont

Co d e 39

Running Applications

5

Using the VTXXX/ANSI Keypad The TRAKKER 2425 TE terminal comes with a special keypad that contains most of the keys available on your VT100/220/320 keyboard. Use the T2425 keypad to enter data in the TE screens. As on all terminal keyboards, the keys on the T2425 keypad have their main character or function marked directly on the key itself. To access that character or function, just press the key. Your TRAKKER 2425 terminal keypad provides access to TE commands and functions printed above the keys by pressing key combinations. Use the Function Left ( ), Function Right ( ), and Shift ( ) keys to access those characters or functions that do not have an actual key on the keypad. Use this illustration to understand how the keypad works:

)

(

?

Home &

7 242XU.125

For help on how the keypad works, see “Using the Keypad” in Chapter 2. Use this table to locate the VT220/320 editing key functions on the TRAKKER 2425 keypad. VT220/320 Editing Key Find Insert Remove Select Previous screen

Next screen

TRAKKER 2425 Key

(K ( L or ) O (M (P (Q (R

5-17

Page 170

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual THelvC NugFont

Co d e 39

Using the VTXXX/ANSI Keypad

I/O Return

Return

F10

F6

F7 F1

F8 F2

F9 F5

F4

F3

Home &

- *

7

8

9

%

PgRt ^

$

PgLft

4

5

6

!

@

PgDn #

End

Function Left (FnL) key

’

(

PgUp

1

2

BkSp

3

)

Ins

>

Del

0 Fn L f A :

F16

]

Find

<

Sel

F12

F17

-

Ins

"

Prev

? Next

G ;

P

F18

Rem

V

E

Function Right (FnR) key

F19 [ F20 I

J

N

O \

’ S

T

X

Y

/ W

Caps Z

F15

:

R .

F14 } D

=

M

Q ,

{

H

L >

F13 C

`

K

U

+

B

F

Shift key

Enter f

F11 _

~

.

Fn R

Ctrl Tab

Esc

242XU.031

5-18