The text of a manual · part 16 of 46
TRAKKER Antares 2425 Hand-Held Terminal User's Manual, pages 151 to 160
Pages 151 to 160 of 452
The original document is the PDF (2.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2425
Page 151
HelvC NugFont
Co d e 39 Operating the Terminal in a Network
4
The TRAKKER 2425 terminal uses these protocols: Layer
Protocol
Description
Physical
2.4 GHz radio
Provides spread spectrum radio signal control.
Data Link
2.4 GHz RF protocol driver
Provides RF media access control. The default hardwired media access control (MAC) protocol used with TCP/IP supports the Ethernet II standard.
Network
IP and ARP
The Internet Protocol (IP) complies with the standard outlined in RFC 791. The Address Resolution Protocol (ARP) complies with the standard outlined in RFC 826.
Transport
Session and Presentation
UDP
The User Datagram Protocol (UDP) complies with the standard outlined in RFC 768.
ICMP
The Internet Control Message Protocol (ICMP) complies with the standard outlined in RFC 792.
UDP Plus
UDP Plus is an Intermec proprietary session layer protocol built on the UDP protocol. The UDP Plus session layer provides these services: • • • • • •
Presentation and Application guaranteed delivery duplicated message removal link connection and status management network error recovery congestion control device error detection
TFTP
Trivial File Transfer Protocol (TFTP) allows efficient file exchange between the terminal and the Model 200 Controller. TFTP complies with the standard outlined in RFC 1350.
TMF
Terminal Message Format is used to route data, configuration, and network management messages between applications on the T2425 terminal and peer tasks on the controller or host.
4-23
Page 152
Page 153
5 Running Applications
Page 154
HelvC NugFont
Co d e 39
Page 155
HelvC NugFont
Co d e 39
Running Applications
5
This chapter provides information to configure and run applications on your TRAKKER 2425 hand-held terminal.
Learning About the Terminal Applications Your TRAKKER 2425 terminal is configured and loaded with one of these applications: • IBM 3270 terminal emulation (Telnet terminal type 3278-2) • IBM 5250 terminal emulation (Telnet terminal type 3179-2) • VT100/220/320 and ANSI terminal emulation • 3270 or 5250 screen mapping Terminal emulation (TE) and screen mapping run on the Intermec UDP Plus protocol that provides reliable data transfer between a host computer and the T2425 hand-held terminals. TE allows the terminal to communicate through the Model 200 Controller to the host application as if it were directly connected to the host. The controller sends data to the terminal in a screen format that emulates the host session. You can use the viewporting capabilities on the terminal to view the host screen. Screen mapping sends screen transactions from a terminal through the controller to a host application. On the controller, you create the terminal screens, group them into menus, and generate each menu into a terminal template that is downloaded to the terminal. Script files that you build on the controller allow the transaction fields from the terminal screens to be mapped to different host screen fields.
5-3
Page 156
TRAKKER Antares 2425 Hand-Held Terminal User’s Manual THelvC NugFont
Co d e 39
Starting Your Application Make sure you have installed the terminal in your 2.4 GHz network. For help, see Chapter 1, “Getting Started.” If you have already completed these tasks, you can start your application. To start your application 1. Press the q key to turn on the terminal.
2. Wait a few seconds while the display clears and the application starts. Once the display on the T2425 shows the sign on screen, you are ready to use your terminal. For screen mapping, you may also see the template menu if a template has been downloaded from the controller.
3270/5250 Sign On Screen
VTXXX/ANSI Login Screen
* Sign on User.............. Password.......... Program/procedure. Menu.............. Current Library...
*
* File
<login:
TNAPP TNAPP
Screen Mapping Screen
F
Name:
TNAPP
F
F 242XU.014
Note: If your application does not start after a few seconds, you may not have configured the T2425 correctly. For help, see Chapter 1, “Getting Started.” Now that you have started your application, you need to learn how to use it. For help, turn to these sections: • “Using 3270 and 5250 Terminal Emulation,” on page 5-5. • “Using VT100/220/320 or ANSI Terminal Emulation,” on page 5-16. • “Using 3270 and 5250 Screen Mapping,” on page 5-26.
5-4
Page 157
HelvC NugFont
Co d e 39
Running Applications
5
Using 3270 and 5250 Terminal Emulation Your TRAKKER 2425 terminal contains a special keypad and firmware that provide most of the commands available to emulate an IBM 3270 or 5250 terminal. You can use your T2425 terminal to: • view host terminal screens on your T2425 display. • enter data into the screens using the scan module or keypad. • access host commands and perform host functions. • automatically transmit the data to the host. After you have installed the terminal in your system, you need to learn how to configure and use the terminal emulation application. The next sections cover these topics: • Using the 3270 or 5250 keypad • Configuring 3270 or 5250 TE parameters • Understanding status line messages
5-5
Page 158
TRAKKER Antares 2425 Hand-Held Terminal User’s Manual THelvC NugFont
Co d e 39
Using the 3270 or 5250 Keypad The TRAKKER 2425 terminal comes with a special keypad that contains most of the keys available on your 3270 or 5250 terminal keyboard. Use the T2425 keypad to enter data in the TE screens. As on all terminal keyboards, the keys on the T2425 keypad have their main character or function marked directly on the key itself. To access that character or function, just press the key.
)
Your T2425 keypad provides access to TE commands and functions printed above the keys by pressing key combinations. Use the Function Left ( ), Function Right ( ), Shift ( ), and Control ( ) keys to access those characters or functions that do not have an actual key on the keypad. Use this illustration to understand how the keypad works:
(
Fld +
?
=
* Fld-
8 242XU.124
For help on how the keypad works, see “Using the Keypad” in Chapter 2.
5-6
Page 159
HelvC NugFont
Co d e 39
5
Running Applications
Using the 3270 or 5250 Keypad 3270
5250
I/O
I/O Enter
F6
F7 F1
F8 F2
7
8
9
%
PgRt ^
5
6
PA3 @
PgDn #
1
2
3
)
Ins
F11 A
: F16
F17
-
F22
"
Stat
?
G ;
F18
D
E
4
5
6
!
@
PgDn #
1
M
2
P
Q
R
S
, Hm
. Clear
/ Attn
U
V
W
X Ctrl
Tab
T ¢
>
Del
U
Y
F17
-
F22
"
Stat
?
G ;
,
F13
F18
Z
F15 E
F19 [ F20 I
J F24
M R
F14 } D
=
F23
’
N
O \ Help
R
S
Hm
. Clear
/ Attn
V
W
X Ctrl
Tab
¬ E-Eof
R
Q
Caps
Reset Esc
{
H
L >
P | Sysrq
E-Inp
+
C
`
K < NL
F12 B
F
Shift key
Enter f _
F16
F21
.
Fn R
A
]
O \
3
)
Ins
~ F11
:
¬ E-Eof
N ’
Caps
Function Right (FnR) key
J F24
| Sysrq
Z
9
0
F19 [ F20 I
F23
(
PgRt ^
Fn L
F15
Fld- PgUp
%
BkSp
F14 }
=
H
L >
{
*
M3 F5
8 f F13
F4
$
End
Enter
C
`
K < NL
+
B
F ] F21
F12
Fld+
F10 M2
M1 F9 F3
7 f _
F8
.
Fn R f ~
Function Left (FnL) key
Fld Exit
F2
Home &
>
Del
0 Fn L
F7 F1
PgLft
!
BkSp
F6
(
PgUp
4 End
M3 F5
F4
*
PA2
PgLft $
F10 M2
M1 F9 F3
PA1
Home &
Fld Exit
Enter
T ¢
E-Inp Y ErrRst Esc
Control key 242XU.015
5-7
Page 160
TRAKKER Antares 2425 Hand-Held Terminal User’s Manual THelvC NugFont
Co d e 39
Configuring 3270 or 5250 TE Parameters You can configure several parameters for 3270 and 5250 terminal emulation on the TRAKKER 2425 terminal. These are the TE parameters you can configure: • Terminal • Communications • Viewport
Configuring Terminal Emulation Screens and Options You can access the TE Configuration menu at any time during your terminal emulation session. Use this procedure to configure your 3270 or 5250 terminal emulation program. To configure 3270 or 5250 TE options
(!
1. Press to access the Terminal Emulation menu. The Terminal Emulation menu appears.
TERMINAL
EMULATION
Exit TE Configure
TE
_` Select item [Enter] Next [F1] Help [Esc] Exit 242XU.018
Note: Do not choose the Exit TE option, which exits the terminal emulation application. If you do accidentally exit TE, a warning screen appears and you will be prompted to return to the TE Configuration menu.
5-8