Page 141

HelvC NugFont

You See These Icons

* The Connect icon blinks.

Co d e 39 Operating the Terminal in a Network

4

Status of Communications

What You Need to Do

Partial communications.

You may need to configure the terminal to communicate with the controller. For help, see “Installing and Configuring the Terminal” earlier in this chapter.

The T2425 terminal is trying to establish communications with the Model 200 Controller.

If the terminal is configured, you may need to configure the controller. Make sure the terminal is configured correctly and enabled. Make sure the controller is turned on and data collection is started.

*

Normal communications.

The Connect icon remains on.

The T2425 terminal can communicate with the 0100 Access Point and the Model 200 Controller.

*• The Connect icon remains on, and the Data icon blinks.

*• The Connect icon and Data icon remain on.

Normal communications. The T2425 terminal is sending data to or receiving data from the Model 200 Controller.

Normal communications. The T2425 terminal has received data for an application from the Model 200 Controller. The data is stored in the terminal’s radio buffer until the application is ready to process the data.

You can send and receive data between the terminal and the Model 200 Controller.

You can send and receive data between the terminal and the Model 200 Controller. Note: You may not see the Data icon blink if communications are occurring instantaneously. You can send and receive data between the terminal and the Model 200 Controller.

4-13

Page 142

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Using the Terminal Between Access Points The 0100 Access Point acts as a wireless bridge to provide communications between the TRAKKER 2425 terminal and the Ethernet network. You may have multiple access points in your 2.4 GHz network to provide uninterrupted wireless communication at any location within your facility. To use the terminal between access points and continue sending and receiving data, you must follow these guidelines: • The radio coverage of each access point must overlap to ensure that the roaming T2425 terminal will always have a connection available. • You configure each access point with the same RF domain number and security ID. • You configure the T2425 terminals with the same RF domain and security ID as the access points to which they may communicate. • All access points that the T2425 terminals may communicate with and roam between must be installed in the same IP subnetwork. The T2425 terminal cannot roam between IP subnetworks. Once the network is configured, you can collect data anywhere within range of the access points in the wireless network. When you move out of range of one access point, the terminal automatically polls the other access points in the same RF domain to continue the network connection. If you are out of range of all access points in the network, the data is stored in the terminal’s radio buffer. The Data icon appears on the display and the Connect icon starts flashing or turns off. You can continue to collect data until the radio buffer is full. When the buffer is full, the application displays a communication timeout status. When you move back into range and network communications are re-established, the data in the radio buffer is transmitted to the controller and you can once again transmit data.

4-14

Page 143

HelvC NugFont

Co d e 39 Operating the Terminal in a Network

4

Configuring the Terminal Over the Network You can remotely configure the TRAKKER 2425 terminal by using one of these methods: • Send a command from the Model 200 Controller. • Send a command from an application on the host computer. You cannot configure any of the network parameters, such as terminal IP address, over the network. Once the terminal is communicating, you can configure bar code symbologies and operating commands. Note: You can configure the terminal locally by using the TRAKKER 2400 Menu System or by scanning a command from a Code 39 or Code 93 bar code label. For help, see Chapter 3, “Configuring the Terminal.”

Configuring the Terminal From the Controller You can use the Model 200 Controller to configure one or more terminals in your 2.4 GHz network. You can also send reader commands such as Backlight On to one or more terminals. This method is very fast and efficient if you need to change the same configuration parameters for several terminals in one area. For example, you may want to set the Beep Volume to very loud and turn on Keypad Caps Lock for all the terminals in one area. Note: You can configure a terminal from the Model 200 Controller, but you cannot get configuration data from the terminal. To send commands from the controller 1. Using the Download Server feature on the controller, select the terminal or group to which you want to download the configuration commands. For help on configuring a group of terminals, see the Model 200 Controller System Manual. Note: You can continue running an application on the TRAKKER 2425 terminal while configuring the terminal from the controller.

4-15

Page 144

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

2. Choose the option to enter a command. 3. Enter the reader or configuration command and choose Add. The command appears in the Files and Data box. For example, enter this command to set the Beep Volume to very loud: $+BV4 For a list of reader commands, see Chapter 7, “Reader Command Reference.” For a list of configuration commands, see Chapter 8, “Configuration Command Reference.” Note: You can set the Postamble or Preamble command to use characters from the extended ASCII character set such as the Field Exit code for 5250 TE. For help, see “Auto-Advancing Through Fields on 5250 TE Screens” in Chapter 5. 4. Repeat Step 3 to add another reader or configuration command, or choose OK. 5. Choose Download to download the commands and change the runtime configuration of the terminals selected. When you remotely configure the terminal, the commands change the terminal’s runtime configuration. The configuration changes are not saved in flash memory. You must use the TRAKKER 2400 Menu System to save the configuration in flash memory. For help, see “Saving Configuration Changes in Flash Memory” in Chapter 3.

4-16

Page 145

HelvC NugFont

Co d e 39 Operating the Terminal in a Network

4

Configuring the Terminal From the Host Computer You can use the host computer to configure one TRAKKER 2425 terminal in your 2.4 GHz network. For example, you may want to change the Beep Volume command and the Display Backlight Timeout command. To send and receive configuration data, you need to write an application for the host computer that can communicate with the Model 200 Controller. For help, see the Model 200 Controller Technical Reference Manual. You use the Terminal Message Format (TMF) protocol in the 2.4 GHz network to send and receive transactions between the host application and the terminal. When you remotely configure the terminal from a host application, the commands change the terminal’s runtime configuration. The configuration changes are not saved in flash memory. You must use the TRAKKER 2400 Menu System to save the configuration in flash memory. For help, see “Saving Configuration Changes in Flash Memory” in Chapter 3. Note: You can continue running an application on the TRAKKER 2425 terminal while configuring the terminal from the host computer. To set up the Model 200 Controller • Configure a destination name for the host application. Create a transaction ID, $NGCFGRSP, that will be routed to this destination name. The controller uses the transaction ID to route responses from the terminal back to the host application. $NGCFGRSP is a special transaction ID that the controller uses to forward configuration response data from a terminal. All configuration responses will be routed with the $NGCFGRSP transaction ID. The controller cannot keep track of multiple applications sending configuration commands. If you have two host applications sending configuration commands, they must both be configured to receive the $NGCFGRSP transactions, and therefore both will receive all responses from all TRAKKER 2425 terminals. To set up the host computer • Verify that you can communicate with the Model 200 Controller.

4-17

Page 146

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

To set up the application • Prepare and write a host application that can communicate with the controller and send transactions to and receive transactions from the terminal in this format: transaction header

TMF field configuration command where: transaction header is a 96-byte field containing the message number, date and time, source application ID, destinations application ID, transaction ID, and other information. You must set the system message (SYS$MSG) flag to E in the transaction header. For help, see the Model 200 Controller Technical Reference Manual.

TMF field is a 2-byte field containing one of these values:

TMF field (continued)

configuration command

4-18

CG

Configuration Get request sent from the host application.

Cg

Configuration Get response sent from the terminal to the host.

CS

Configuration Set request sent from the host application.

Cs

Configuration Set response sent from the terminal to the host.

is the configuration command or commands you want to set on the terminal, or get the current value of from the terminal. For a list of configuration commands, see Chapter 8, “Configuration Command Reference.”

Page 147

HelvC NugFont

Co d e 39 Operating the Terminal in a Network

4

Example 1 In the host application, you want to get the current values of three configuration commands from the terminal. Send this transaction from the host application: CG$+NABVDF Note: The transaction header is not shown in this example. where: CG is a TMF Configuration Get request.

$+ is the Change Configuration reader command.

NA is the Network Activate configuration command.

BV is the Beep Volume configuration command.

DF is the Display Backlight Timeout configuration command.

The terminal returns this transaction to the host application. Cg$+NA1BV2DF60 where: Cg is a TMF Configuration Get response.

$+ is the Change Configuration reader command.

NA1 means the Network Activate configuration command is currently set to a value of 1, which means that the 2.4 GHz network is enabled.

BV2 means the Beep Volume configuration command is currently set to a value of 2, which is a normal beep volume.

DF60 means the Display Backlight Timeout configuration command is currently set to a value of 60 seconds.

4-19

Page 148

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Example 2 In the host application, you want to set the value for two configuration commands on the terminal. Send this transaction from the host application: CS$+BV4DF30 Note: The transaction header is not shown in this example. where: CS is a TMF Configuration Set request.

$+ is the Change Configuration reader command.

BV4 sets the Beep Volume configuration command to a value of 4, which is a very loud beep volume.

DF30 sets the Display Backlight Timeout configuration command to a value of 30 seconds.

The terminal returns this transaction to the host application. Cs$+BV4DF30 where:

4-20

Cs is a TMF Configuration Set response.

$+ is the Change Configuration reader command.

BV4 means the Beep Volume configuration command has been changed to a value of 4, which is a very loud beep volume.

DF30 means the Display Backlight Timeout configuration command has been changed to a value of 30 seconds.

Page 149

HelvC NugFont

Co d e 39 Operating the Terminal in a Network

4

About Network Connectivity and Protocols The TRAKKER 2425 terminals are hand-held data collection terminals with network support. The T2425 terminal communicates with a host computer in the 2.4 GHz network through the Model 200 Controller across the Ethernet network. The 0100 Access Point acts as a bridge between the Ethernet network and the wireless 2.4 GHz network. The controller supports the terminals using Intermec’s UDP Plus protocol. The communications protocol stack for the TRAKKER 2425 terminal is fit to the Open Systems Interconnection (OSI) seven layer model. The illustration on the next page shows how the 2.4 GHz network maps into the OSI model. The terminal applications including terminal emulation and screen mapping are on top of the protocol stack. Intermec provides a terminal communications API (application program interface) to interface to the protocol stack. The API provides a common interface to these Intermec value-added protocols: • Terminal Message Format (TMF) is used to route data and network management messages between applications on the T2425 terminal and peer tasks on the controller or host computer. • UDP Plus is an Intermec protocol built on top of User Datagram Protocol (UDP). It maximizes the performance of wireless (RF) and hardwired networks. • Trivial File Transfer Protocol (TFTP) allows efficient file exchange between the T2425 terminal and the Model 200 Controller. • Network management provides network access to the T2425 terminal configuration, status, and statistics. Network management uses the Terminal Message Format to receive and send messages. The remaining layers in the protocol stack are a series of standard protocols that interface with the drivers and hardware needed to support the 2.4 GHz network.

4-21

Page 150

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

TRAKKER 2425 Terminal Protocol Stack s tion inal applica m r e g T n appi 2425 KERscreen m K A d TR n an 425 latio u KER 2 m al e TRAKrminal n i m Te ter ack col St Proto s ddition and a I P A ) ons t (TMF unicati Forma e Comm g a s al Mes Termin lus UDP P l File Trivia rotocol P r fe s Tran FTP) (T rk Netwo nt me e g a n ma ation

Applic n ntatio

Prese n

Sessio port

Trans rk

Netwo UDP ICMP ink

Data L

P nd AR

IP a river col d F proto zR

H 2.4 G io

Hz rad

2.4 G

4-22 al

Physic

0

U.09

242X