Page 131
HelvC NugFont
Co d e 39 Operating the Terminal in a Network
4
This chapter describes the 2.4 GHz network and explains how the TRAKKER 2425 terminal fits in your network. It also explains how to install and configure the terminal, use RF communications, configure the terminal over the network, and provides technical details about network connectivity and protocols.
How the TRAKKER 2425 Fits Into Your Network The TRAKKER 2425 terminal is a hand-held data collection terminal with network support. The T2425 terminal communicates with a host computer in the Intermec 2.4 GHz network through the Model 200 Controller across the Ethernet network. The 0100 Access Point acts as a bridge to allow communications between the Ethernet network and the wireless T2425 terminals.
TRAKKER 2425 Terminals in a 2.4 GHz Radio Frequency Data Collection Network Host
TRAKKER 2425 terminals
0100 Access Point
Ethernet Model 200 Controller
242XU.095
4-3
Page 132
TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont
Co d e 39
Installing TRAKKER 2425 Terminals in Multiple Subnetworks Model 200 Controller
192.9.175.7
Router Ethernet
0100 Access Point
TRAKKER 2425 terminals 192.9.200.5, 192.9.200.6
T2425's cannot roam between subnetworks
192.9.200.X subnetwork
0100 Access Point
192.9.175.X subnetwork
0100 Access Point
TRAKKER 2425 terminals 192.9.175.10 192.9.175.11 192.9.175.12
242XU.091
You can install the TRAKKER 2425 terminals, 0100 Access Points, and Model 200 Controller in your 2.4 GHz network as shown in the illustration above. The T2425 terminals may only communicate with the access points that are in the same IP subnetwork. All the terminals and access points in this illustration communicate with the controller at IP address 192.9.175.7.
4-4
Page 133
HelvC NugFont
Co d e 39 Operating the Terminal in a Network
4
TRAKKER 2425 Terminals Communicating Across Subnetworks Model 200 Controller
192.9.200.5
192.9.200.X subnetwork
Router
192.9.175.X subnetwork Ethernet
192.9.175.1
0100 Access Point
TRAKKER 2425 terminals 192.9.175.9 192.9.175.10 192.9.175.11
242XU.092
You can install the TRAKKER 2425 terminals and 0100 Access Points in one IP subnetwork and install the Model 200 Controller in another IP subnetwork as shown in the illustration. In this network, you must configure additional network parameters (default router and subnet mask) as described later in this chapter. Note: All 0100 Access Points that the TRAKKER 2425 terminal may communicate with and roam between must be on the same IP subnetwork. The terminal cannot roam between IP subnetworks.
4-5
Page 134
TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont
Co d e 39
Installing and Configuring the Terminal Before you can begin using the TRAKKER 2425 terminal to collect data, you need to install and configure each device in the 2.4 GHz network by performing these steps: 1. Plan and prepare your network. Make sure you have all the equipment required to use the terminal in the network. Make sure you have IP addresses for all devices in the network. 2. Configure the Model 200 Controller. 3. Configure the 0100 Access Point. 4. Configure each TRAKKER 2425 terminal. Each step is described in detail in the next sections.
Planning the Network Connection To use the TRAKKER 2425 terminal in the 2.4 GHz network, you need these minimum requirements: • Model 200 Controller • 0100 Access Point • An Ethernet cable drop: 10Base2 (thin coax BNC) or 10BaseT (twisted pair) When you first consider purchasing a wireless data collection system, an Intermec representative works with you to perform a site survey at your facility. The site survey analyzes the range of radio frequency devices in your facility and determines the placement of the access points. The site survey ensures that the coverage of each access point overlaps to provide uninterrupted wireless access at any location within the building. This manual assumes that a site survey is complete and the access points are installed in your facility. You need to work with your network administrator to plan and assign the IP address for each device in the 2.4 GHz network. You must assign and set the IP address for the Model 200 Controller, each 0100 Access Point, and each TRAKKER 2425 terminal.
4-6
Page 135
HelvC NugFont
Co d e 39 Operating the Terminal in a Network
4
Configuring the Model 200 Controller The Model 200 Controller supports communications with the 2.4 GHz network across the Ethernet network. When you install and configure the controller, you identify the host computer(s) and TRAKKER 2425 terminals in your network. The terminals communicate through the controller with your host computer. For help installing the controller, see the Model 200 Controller System Manual (Part No. 063439). To have the T2425 terminal communicate with the controller, you must configure these parameters on the controller: • Configure the UDP (User Datagram Protocol) Plus network. • Assign an IP address to each TRAKKER 2425 terminal. • Enable all T2425 terminals. • Define the host environment parameters, which includes configuring for terminal emulation or screen mapping. • Define the host communications parameters, which includes the physical connection (network adapter cards) to the host computer. To use the screen mapping application on the T2425 terminal, you must also configure the following: • Create the script file using the Script Builder tool on the controller. • Generate the template to download to the T2425 terminal.
Configuring the 0100 Access Point The 0100 Access Point acts as a wireless bridge to provide RF communications between the TRAKKER 2425 terminal and the Model 200 Controller. For help, see the 0100 Access Point User’s Manual (Part No. 062367). Note: All access points that the TRAKKER 2425 terminal may communicate with and roam between must be in the same IP subnetwork. To have the T2425 terminal communicate with the access point, you must know the value of these parameters on the access point: • RF domain • RF security identification (ID) (optional)
4-7
Page 136
TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont
Co d e 39
Configuring the Terminal When you install the TRAKKER 2425 terminal in a network, you must configure a set of network parameters that control how the terminal communicates in the network. There are two ways to configure the network parameters: • Use the TRAKKER 2400 Menu System. For help on configuring the network parameters, see Chapter 1, “Getting Started.” For help on the menu system, see Chapter 3, “Configuring the Terminal.” • Scan the configuration command from a Code 39 or Code 93 bar code label. The configuration commands are listed alphabetically by command name in Chapter 8, “Configuration Command Reference.” The set of network parameters you must configure depends on whether you install the terminal on the same IP subnetwork as the Model 200 Controller, or on a different subnetwork. This table lists the parameters you configure in each type of network: Network Parameters Time and date
Same IP Subnetwork? X
Different IP Subnetwork? X
Network activate
X
X
Controller IP address
X
X
Terminal IP address
X
X
RF domain
X
X
Optional
Optional
RF security ID Default router
X
Subnet mask
X
The network parameters are defined in the next section.
Defining the Network Parameters This section defines the network parameters you configure when installing the TRAKKER 2425 terminal in a network. For each parameter’s syntax and options, see Chapter 8, “Configuration Command Reference.”
4-8
Page 137
HelvC NugFont
Co d e 39 Operating the Terminal in a Network
4
Time and Date When you turn on the terminal for the first time, you must set the current time and date. You also need to set the time and date any time you lose all power to the terminal. For help, see “Setting the Time and Date” in Chapter 1. Network Activate Disables or enables RF communications in the 2.4 GHz network. If the Network Activate parameter is disabled, the network is disabled, no RF communications are provided, and the radio is turned off. When the Network Activate parameter is enabled, the TRAKKER 2425 terminal will attempt to connect to the Model 200 Controller. Controller IP Address An IP address is a network level address you assign to each device in a TCP/IP network. The Controller IP Address identifies the IP address assigned to the Model 200 Controller. Terminal IP Address An IP address is a network level address you assign to each device in a TCP/IP network. The Terminal IP Address identifies the IP address assigned to the T2425 terminal. The IP address you set on the terminal must match the address that is set on the controller. RF Domain The domain defines a logical partition or subnetwork of the network. To establish communications, you must assign the same domain number to every RF device in a wireless network. The domain number you set on the terminal must match the domain that is set on each access point the terminal may communicate with. You can continue to collect data with the terminal as you roam in between access points as long as all the devices have the same domain number. RF Security Identification (ID) This optional parameter defines the password you can set for secured transmission and receipt of data between devices in the wireless network. To communicate, each access point and terminal must have matching security IDs. If the security ID is set on the 0100 Access Point, you must also set the security ID on each terminal that may communicate with the access point. Note: You can only set the RF security ID with the 2.4 GHz network enabled. The Network Activate command must be configured to 2.4 GHz RF Network before you can save any changes to the RF security ID parameter.
4-9
Page 138
TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont
Co d e 39
Default Router Provides a software and hardware connection between two or more networks that permits traffic to be routed from one network to another on the basis of the intended destinations of that traffic. When the Model 200 Controller is on a different subnetwork than the T2425 terminal, you need to set the IP address assigned to the default router. The terminal uses the router address to send packets across the network to the controller. The default router must have an IP address on the same subnetwork as the terminal. The default of 0.0.0.0 means there is no default router. Subnet Mask The subnet mask is an internal TCP/IP protocol stack variable that is used in IP protocol to identify the subnetwork for an IP address. The IP protocol performs a bit-wise AND on the IP address and the subnet mask. Each address segment represents one byte, where 255 converts to FF hex. This computation is used to find out if the controller and terminal are on different subnetworks. If the terminal is on a different IP subnetwork than the controller, then you must set the subnet mask and default router. For example, if the terminal IP address is 192.9.150.184 and the subnet mask is 255.255.255.0, the terminal is on the subnetwork 192.9.150.0.
4-10
Page 139
HelvC NugFont
4
Co d e 39 Operating the Terminal in a Network
Using RF Communications on the Terminal Once you have configured the devices in the 2.4 GHz network, you can begin using the TRAKKER 2425 terminal application to collect and transmit data via RF communications. Each terminal is shipped with only one of these applications: • 3270 terminal emulation • 5250 terminal emulation • VT100/220/320 or ANSI terminal emulation • 3270 or 5250 screen mapping To use the terminal q
• Press to turn on the terminal. One of these login or application screens appear. For screen mapping, you may also see the template menu if a template has been downloaded from the controller.
3270/5250 Sign On Screen
VTXXX/ANSI Login Screen
* Sign on User.............. Password.......... Program/procedure. Menu.............. Current Library...
*
F
* File
<login:
TNAPP TNAPP
Screen Mapping Screen
F
TNAPP
Name:
F 242XU.014
If the terminal is correctly configured and communicating with your host computer, the terminal will connect and begin running the default application. You can begin using the terminal to collect data. For help, see Chapter 5, “Running Applications.”
4-11
Page 140
TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont
Co d e 39
Using the Icons to Monitor Communications As you use the TRAKKER 2425 terminal to collect data, icons are displayed to help you monitor RF and network communications on the terminal. Use the two icons shown in the illustration to monitor communications between the terminal and other devices in the 2.4 GHz network.
*• Sign on User.............. Password.......... Program/procedure. Menu.............. Current Library...
TNAPP
F 242XU.093
You See These Icons
Status of Communications
What You Need to Do
No communications.
You need to enable the Network Activate command. For help, see “Network Activate” in Chapter 8.
The Radio icon remains on.
The T2425 terminal is not connected to the 0100 Access Point. The Network Activate command is disabled, or there is a problem with the radio card and it is turned off.
No icons appear.
No communications. The T2425 terminal is not connected to the 0100 Access Point.
Make sure the access point is turned on and operating. You may also be using the terminal out of the RF range of an access point. Try moving closer to an access point to re-establish communications. If the access point is on and you are in range, you may need to configure the terminal to communicate in the network. For help, see “Installing and Configuring the Terminal” earlier in this chapter.
4-12