Page 121

HelvC NugFont

Co d e 39 Configuring the Terminal

3

Upgrading the Firmware The terminal firmware includes these items: • TRAKKER 2400 Menu System • Terminal emulation or screen mapping application • TE Configuration Menu • Operating environment, firmware, and drivers When a new release of the firmware is available, your local Intermec service representative can upgrade the firmware on the TRAKKER 2425 terminal. For help, contact your local Intermec service representative. To upgrade the firmware 1. Press

) y T 2 M or scan this bar code:

Enter Test and Service Mode

*..-.* *..-.*

The Main Menu appears. 2. Choose System Menu and press SYSTEM

;. The System Menu appears.

MENU

Load Default Values Set Time and Date Store Configuration Upgrade Firmware

_` Select item [Enter] Next screen [F1] Help [Esc] Exit 242XU.051

3-23

Page 122

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

3. Choose the Upgrade Firmware command and press Firmware screen appears.

UPGRADE

Co d e 39

;. The Upgrade

FIRMWARE

Upgrade terminal firmware? Make sure the terminal is connected to a host computer through the optical adapter.

OK

CANCEL 242XU.074 d

4. To exit without upgrading, choose Cancel. The System Menu appears. Press to exit the System Menu. The Main Menu appears. If you are upgrading the firmware with your local Intermec service representative, choose OK to continue and upgrade the firmware. The terminal reboots and then displays the Loader Waiting screen. For help, see the Readme.txt file on the TRAKKER Antares Firmware disk.

d q B

Note: If you reach the Loader Waiting screen and cannot upgrade or continue, press or to exit without upgrading the firmware. The Boot Menu appears. Press to boot the terminal and continue. 6. Choose another menu from the Main Menu or press TRAKKER 2400 Menu System.

3-24 d to exit the

Page 123

HelvC NugFont

Co d e 39 Configuring the Terminal

3

Recording Your Terminal’s Configuration These tables list all of the configuration parameters, their options, and where to find them in the Configuration Menu of the TRAKKER 2400 Menu System. The default setting for each parameter is identified in bold italics in these tables. You should have an accurate record of the terminal’s configuration settings in case the terminal’s volatile memory and the configuration setup is lost. You can record the configuration on the following pages by circling the option you chose for each parameter or writing the value.

Bar Code Symbologies Table Parameter (Syntax)

Options

Location in Configuration Menu

Codabar (CD)

Disabled ABC Standard Concatenated

Symbologies Menu, Codabar option

Start/Stop digit

Discard Retain ABCD Retain DC1-DC4

Code 11 (CG)

Disabled One check digit Two check digits

Symbologies Menu, Code 11 option

Code 16K (CP)

Disabled Standard Function code 1

Symbologies Menu, Code 16K option

Code 2 of 5 (CC)

Disabled 3 bar start/stop, label length 2 bar start/stop, label length

Symbologies Menu, 2 of 5, I2 of 5 option

Code 39 (CB)

Disabled No check digit Check digit HIBC AIAG check digit

Symbologies Menu, Code 39 option

Check digit

Discard Retain

3-25

Page 124

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Bar Code Symbologies Table (continued) Parameter (Syntax)

Options

Location in Configuration Menu

Code 39 (continued) ASCII

Non-full ASCII Full ASCII Mixed-full ASCII

Symbologies Menu, Code 39 option

Code 49 (CJ)

Disabled Enabled

Symbologies Menu, Code 49 option

Function Code 1 (CK)

None (disabled) Any two ASCII characters

Function Code 2 (CL)

\x0D\x0A (CR LF) Any four ASCII characters

Function Code 3 (CM)

None (disabled) Any two ASCII characters

Code 93 (CF)

Disabled Enabled

Symbologies Menu, Code 93 option

Code 128 (CH)

Disabled Standard UCC/EAN-128

Symbologies Menu, Code 128 option

Interleaved 2 of 5 (CA)

Disabled Fixed length Variable length, no check digit Case Code, check digit Variable length, check digit

Symbologies Menu, 2 of 5, I2 of 5 option

MSI (CN)

Disabled No check digit 1 modulus 10 check digits 2 modulus 10 check digits

Symbologies Menu, MSI option

Discard Retain

Symbologies Menu, MSI option

Disabled Discard check digit Retain check digit

Symbologies Menu, Plessey option

Check digits Plessey (CI)

3-26

Page 125

HelvC NugFont

Co d e 39 Configuring the Terminal

3

Bar Code Symbologies Table (continued) Parameter (Syntax)

Options

Location in Configuration Menu Symbologies Menu, UPC/EAN option

UPC/EAN (CE) UPC-A/EAN-13 (Version A)

Disabled Enabled UPC-A only

UPC-E (Version E)

Disabled Enabled

EAN-8

Disabled Enabled

Supplementals

Yes No

Check digit

Discard Retain

Number system digit

Discard Retain

UPC-A leading zero

Discard Retain

3-27

Page 126

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Communications Table Parameter (Syntax)

Options

Location in Configuration Menu

Controller IP Address (NC)

0.0.0.0 The IP address field is four numbers separated by periods.

Communications Menu, Primary Network option

Default Router (NX)

0.0.0.0 The Router field is four numbers separated by periods.

Communications Menu, Advanced Network option

Network Activate (NA)

Disabled 2.4 GHz RF (enabled)

Communications Menu, Primary Network option

Network Loopback (NL)

Disabled Enabled

Communications Menu, Advanced Network option

RF Domain (RW)

0 0 - 15

Communications Menu, RF Driver option

RF Security ID (RS)

None (no characters) Any 20 ASCII characters

Communications Menu, RF Driver option

RF Wakeup On Broadcast (RB)

No (disabled) Yes (enabled)

Communications Menu, RF Driver option

Subnet Mask (NS)

255.255.255.0 The Subnet Mask field is four numbers separated by periods. Each number is from 0 to 255.

Communications Menu, Advanced Network option

Terminal IP Address (ND)

0.0.0.0 The IP address field is four numbers separated by periods.

Communications Menu, Primary Network option

UDP Port (NG)

05555 5001 - 65535

Communications Menu, Advanced Network option

3-28

Page 127

HelvC NugFont

Co d e 39 Configuring the Terminal

3

Terminal Operations Table Parameter (Syntax)

Options

Location in Configuration Menu

Append Time (DE)

Disabled Enabled

Terminal Menu, Append Time option

Auto Shutoff (EZ)

0 (disabled) 2 - 75 minutes

Terminal Menu, Power Management option

Beep Volume (BV)

Off Quiet Normal Loud Very loud

Terminal Menu, Beeper option

Decode Security (CS)

Low Moderate High

Terminal Menu, Scanner option

Display Backlight Timeout (DF)

Disabled (0) 1 - 60 seconds 10 seconds

Terminal Menu, Display option

Display Contrast (DJ)

0-7 3

Terminal Menu, Display option

Keypad Caps Lock (KA)

On Off

Terminal Menu, Keypad option

Keypad Clicker (KC)

Disabled Enabled

Terminal Menu, Keypad option

Postamble (AE)

None (no characters) Any 25 ASCII characters

Terminal Menu, Preamble/Postamble option

Preamble (AD)

None (no characters) Any 25 ASCII characters

Terminal Menu, Preamble/Postamble option

Reader Commands (DC)

Disable all reader commands Enable all reader commands Enable override Disable override

Terminal Menu, Reader Commands option

3-29

Page 128

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual HelvC NugFont

Co d e 39

Terminal Operations Table (continued) Parameter (Syntax)

Options

Location in Configuration Menu

Reader Commands (DC) Enable/Disable specific Reader Commands

Backlight Backspace Change Configuration Clear Default Configuration Enter Accumulate mode Exit Accumulate mode Multiple-Read Labels Reset Scanner Trigger Off Scanner Trigger On Test & Service Mode

Terminal Menu, Reader Commands option, Enable single commands option

Resume Execution (ER)

Not Allowed Allowed

Terminal Menu, Power Management option

Scan Ahead (SD)

Disabled Enabled

Terminal Menu, Scanner option

Scanner Mode (SB)

One-Shot mode Automatic (Auto-trigger) mode

Terminal Menu, Scanner option

Scanner Redundancy (SR)

None Normal High

Terminal Menu, Scanner option

Scanner Selection (SS) (See the Note below)

All compatible scanners 146x CCD scanners 155x laser scanners 151x laser scanners 1545 laser scanner Symbol scanners

Terminal Menu, Scanner option

Scanner Timeout (SA)

Disabled (0) 1-60 seconds

Terminal Menu, Scanner option

Scanner Trigger (SC)

Level Edge

Terminal Menu, Scanner option

Time in Seconds (DA)

Disabled Enabled

Terminal Menu, Append Time option

Note: The Scanner Selection command is only used when you have a module for cabled scanners installed. If you have a standard range scan module, Scanner Selection shows the option “Integrated Scanner.”

3-30

Page 129

HelvC NugFont

Co d e 39

4 Operating the Terminal in a Network

Page 130

HelvC NugFont

Co d e 39