Page 171

HelvC NugFont

Co d e 39

Running Applications

5

Configuring VTXXX/ANSI TE Parameters You can configure several parameters for VTXXX/ANSI terminal emulation on the TRAKKER 2425 terminal. These are the TE parameters you can configure: • Terminal • Communications • Viewport

Configuring Terminal Emulation Screens and Options You can access the TE Configuration menu at any time during your terminal emulation session. Use this procedure to configure your VTXXX/ANSI terminal emulation program. To configure VTXXX/ANSI TE options

(!

1. Press to access the TE Configuration menu. The Terminal Emulation menu appears.

TERMINAL

EMULATION

Exit TE Configure

TE

_` Select item [Enter] Next [F1] Help [Esc] Exit 242XU.018

Note: Do not choose the Exit TE option, which exits the terminal emulation application. If you do accidentally exit TE, a warning screen appears and you will be prompted to return to the TE Configuration menu.

5-19

Page 172

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual THelvC NugFont

2. Choose Configure TE and press appears.

TE

Co d e 39

;. The TE Configuration menu

CONFIGURATION

Terminal Communications Viewport Exit Config Help

_` Select item [Enter] Next [F1] Help [Esc] Exit 242XU.019

[ { ;

3. Press or to highlight the function you want to configure and press . To exit, see “Exiting the TE Configuration Menu” later in this chapter. The Terminal screen contains these options: TERMINAL

Page

1

Text Size Regular Height Terminal Type VT320

OK

CANCEL 242XU.026

Text Size Select the size of text the T2425 displays on the terminal screen. Options are regular height (normal characters) or double height. Terminal Type Select the terminal type of the host system. The supported terminal types are: VT100, VT220, VT320, RDRANSI and ANSI.

5-20

Page 173

HelvC NugFont

Co d e 39

Running Applications

5

Note: If you select ANSI, RDRANSI, or VT100 as the terminal type, you will only see part of the options available on page two of the Terminal screens.

VT220 and VT320 Screen TERMINAL

Page

2

ANSI and VT100 Screen TERMINAL

Page

Terminal Mode VT320 7-Bit User-Defined Key Unlock Keypad Mode Numeric Cursor Mode Cursor

Keypad Mode Numeric Cursor Mode Cursor

OK

OK

CANCEL

2

CANCEL 242XU.027

Terminal Mode (VT220/320 only) Select the Terminal mode that corresponds to your terminal type. This field sets the mode VT-series terminals use to exchange escape sequences, control commands, and status reports with an application. User-Defined Key (VT220/320 only) Select whether you want this parameter set to lock or unlock. When you select lock, you cannot reprogram userdefined keys. When you select unlock, you can program user-defined keys from the host application. Keypad Mode Select Numeric or Application mode. These options generate different key codes. If you select Numeric mode, you generate ANSI cursor control ESC sequences that correspond to what appears on the face of the keys. If you select Application mode, you generate application ESC sequences for the key code. For help, see your VT manual. Cursor Mode Select Cursor or Application mode. These two options generate different key codes. If you select Cursor mode, you generate ANSI cursor control ESC sequences that correspond to what appears on the face of the cursor key.

5-21

Page 174

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual THelvC NugFont

Co d e 39

If you select Application mode, you generate application ESC sequences for the key code. For help, see your VT manual.

TERMINAL

Page

Input Mode Character

OK

3

Mode

CANCEL 242XU.028

Input Mode

Select Line mode or Character mode.

;

If you select Line mode, you can enter a line of characters on your T2425 to send each line of terminal before transmitting data to the host. Press text to the host. In Line mode, communications overhead is reduced because input is sent one line at a time instead of one or a few characters at a time. If you select Character mode, keypad input is immediately sent to the host. The Communications screen contains this option:

COMMUNICATIONS Host Name VAX1

OK

CANCEL 242XU.032

5-22

Page 175

HelvC NugFont

Co d e 39

Running Applications

5

Host Name Enter the name of the host to which you want the terminal to connect. You can enter a host name that is up to 13 characters long. Note: If you have linked a terminal with a host name on the Model 200 Controller, you do not need to enter a host name in this screen. If you have not linked a terminal with a host name on the controller, you must enter a host name for this parameter. The host name in this screen must match a host name in the list of available hosts defined on the controller. The Viewport screen contains these options:

VIEWPORT Viewport Mode Follow Side Boundary 1 Side Jump 10 Vertical Boundary 1 Vertical Jump 8 OK

CANCEL 242XU.022

Viewport Mode

Select one of these viewport movement modes:

Follow

Enables viewport Follow Cursor mode.

Center

Enables viewport Center mode. The viewport always centers around the cursor.

Disable

Disables viewport movement. You must manually move the cursor to each field in the screen.

You can set these parameters for Follow Cursor mode only: Side Boundary The viewport moves when the cursor is this number of characters from the right or left side boundary. You can enter a number from 1 to 10. Side Jump The number of characters the viewport moves right or left when you reach a horizontal boundary. You can enter a number from 1 to 10.

5-23

Page 176

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual THelvC NugFont

Co d e 39

Vertical Boundary The viewport moves when the cursor is this number of characters from the top or bottom boundary. You can enter a number from 1 to 10. Vertical Jump The number of characters the terminal moves up or down when you reach a vertical boundary. You can enter a number from 1 to 10.

Exiting the TE Configuration Menu After entering all configuration parameters, you are prompted to save the new configuration and exit the Configuration Menu. You can choose between several options when prompted to save the new configuration. To exit the Configuration menu 1. From the TE Configuration menu, choose Exit Config and press Save new configuration screen appears.

Save

;. The new configuration?

Yes

No

CANCEL

242XU.023

;

2. Choose Yes and press if you want to save the TE configuration. Your terminal saves the configuration options to flash memory and the sign on screen appears.

;

Choose No and press if you do not want to save the TE configuration. You exit the TE Configuration menu and the sign on screen appears.

;

Choose Cancel and press to return to the TE Configuration menu. You can continue making changes to the TE configuration.

5-24

Page 177

HelvC NugFont

Co d e 39

Running Applications

5

Unsupported TE Functions These functions are not supported for the current terminal emulation firmware version. Terminal Type

Unsupported Functions

3270 and 5250

3270 SFE (Start Field Extended) Order and Write Structured Field commands. 5250 PRINT (X’F6) AID. 5250 transparent data. 5250 Write Control Character (WCC) supports error line adjustment field only. 5250 write error code to window and write single structured field. 5250 extended attributes. 5250 I/O Feature Input Field accepts any character from all sources of input. AutoTab, Autorepeat, and Macro functions. Telnet 3270 Regime option (RfC1041).

VT100/220/320 and ANSI

VT100 does not support these edit keys: home, insert, delete, page up, and page down. VT52 mode, Column mode, Reverse Screen mode, and Interlace mode. Double height and double width characters. Programmable LEDs. Screen alignment test and self-tests. Report terminal parameters command. The terminal does not send a response. Identify terminal function. Select character protection attribute. National replacement and downloadable character sets. Autorepeat mode.

All Types

Printing is not supported.

5-25

Page 178

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual THelvC NugFont

Co d e 39

Using 3270 and 5250 Screen Mapping Make sure you have installed the terminal in your 2.4 GHz network. For help, see Chapter 1, “Getting Started.” Before you can run screen mapping on your terminal, you need to generate a terminal template and script file on the Model 200 Controller. For help, see the Model 200 Controller System Manual. If you have already completed these tasks, you can start your screen mapping application.

Starting the Screen Mapping Application There are two ways to load a template on the T2425 terminal: • You can download the template to the T2425 terminal from the controller. For help, see the Model 200 Controller System Manual. • You can have the terminal request a template from the controller. To request a template from the controller q key to turn on the terminal. The T2425 terminal display 1. Press the prompts you to enter the name of the template you want to use:

File name:

242XU.060

2. Type a template name and press template menu.

;. The terminal displays your

Note: Make sure your template name has a .TPL file extension.

5-26

Page 179

HelvC NugFont

Co d e 39

Running Applications

5

Running Screen Mapping on Your Terminal Once you have selected a template, you need to select the screen where you want to enter data. To enter data into a screen 1. From the template menu, use the you want to use.

ABC

[ or { keys to highlight the screen

Company

Work order entry Shipping Receiving Inventory Time card entry

Select

F2

File

F4 242XU.061

@

2. Press to choose the screen. The screen you chose appears on the terminal display and the screen name is in the title bar. 3. Type or scan data into the fields. Use the data for each field.

[ , {, or ; to accept the

4. When you finish entering data into the fields:

! to send the transaction to the controller. • Press # to reset the screen and reposition the cursor to the first input field without sending the data. • Press % to exit the screen without sending the data and return to the

• Press template screen menu.

5-27

Page 180

TRAKKER Antares 2425 Hand-Held Terminal User’s Manual THelvC NugFont

Co d e 39

Requesting a New Template You can run one terminal template at a time on the TRAKKER 2425 terminal. If you want to change templates, you need to request a new one from the Model 200 Controller. To request a new template from the controller 1. From the template screen menu, press

$ to download a new template.

2. Type the name of the template you want to use when the screen prompts you to enter a file name. Note: Make sure your template name has a .TPL file extension.

File name:

242XU.060

3. Press

5-28

;. The new template menu appears on your terminal.