For the Intermec 2420 and Intermec 2425

Page 467

A Terminal Specifications

Page 468

A-2

Page 469

Nugg

Co de

Terminal Specifications 39

A

This appendix lists the terminal’s physical and environmental specifications, lists the default configuration, and provides a configuration command reference list in alphabetical order by command syntax.

Physical and Environmental Specifications This section lists the physical and environmental specifications for the TRAKKER Antares 2420 and 2425 terminals. Note: For programming and file system specifications, see Chapter 5, “Using Custom Applications.”

Terminal Dimensions Length:

10.6 in (26.9 cm)

Height:

2.8 in (7.1 cm) at scan module 2.3 in (5.8 cm) at grip

Width:

3.2 in (8.1 cm) at scan module 2.5 in (6.35 cm) at grip

Weight: T2420 T2425

22 oz (623.7 g) 27 oz (765.45 g)

Note: The weight includes the main battery pack and the backup battery.

Power Specifications Operating

Rechargeable lithium-ion 1350 mAh battery pack

Memory Backup

Rechargeable NiCad 110 mAh battery

Electrical Specifications Electrical Rating

S 7,2V 500mA

A-3

Page 470

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Nugg Co de

39

Temperature Specifications You need to operate and store the terminal within the temperature ranges listed in this table. Note: For information about using the terminal in cold temperature environments, see “Guidelines for Managing Batteries” in Chapter 6.

Type of Operation

Fahrenheit Temperature Range

Celsius Temperature Range

Charging the battery pack

+32°F to +104°F

0°C to +40°C

Operating the terminal

-4°F to +122°F

-20°C to +50°C

Storing the terminal (with or without batteries installed)

-4°F to +140°F

-20°C to +60°C

Relative Humidity Specifications 0% to 95% noncondensing humidity

Screen •

CGA compatible

•

16 lines x 20 columns (128 x 160 dot matrix), backlit LCD

•

25 lines by 80 columns, virtual display with viewport feature

Keypad Options •

Full alphanumeric keypad with 56 keys, available as an English keypad or a multilingual European language keypad

•

Terminal emulation keypads for IBM 3270, IBM 5250, and VT/ANSI Note: Terminal emulation keypads are available only in English. However, TE applications can display characters in the Western European languages. For help, see the TRAKKER Antares Terminal Emulation User’s Guide.

Application Options

A-4

•

Programmable terminal

•

IBM 3270 terminal emulation

•

IBM 5250 terminal emulation

•

VT100/220/320 and ANSI terminal emulation

Page 471

Nugg

Co de

Terminal Specifications 39

A

Memory •

2MB programmable flash memory, 750K available

•

1MB battery-backed RAM, 512K available

•

(Option) 4MB flash memory (additional 2MB flash for double-byte fonts or drive D)

•

(T2420 option) 2MB or 4MB extended storage drive

Radio Frequency Communications •

2.4 GHz (to 2.4835 GHz) radio

•

Frequency hopping spread spectrum radio

•

100 mW maximum output power

•

1.6 Mbits per second data speed

•

Coverage ≥ 240 feet (80 meters)

RF Network Support Options •

Connectivity to a host on an Ethernet, token ring, twinaxial, coaxial, or SDLC network through an access point and DCS 300 using UDP Plus

•

Connectivity to a host on an Ethernet or token ring network through an access point using TCP/IP

Serial Communications •

Optical serial communications port interface

•

RS-232C, up to 38400 baud

•

XMODEM protocol for data transfer

•

Supports Configurable Serial Protocol and XON/XOFF

Cables for Serial Communications To connect the terminal to a host computer or other device, use these cables with the TRAKKER Antares Optical Link Adapter or the TRAKKER Antares TD2400 Communications Dock. Cable

PC Connector

Part Number

5-wire, null modem

9-pin

059167

3-wire, null modem

25-pin

047569

A-5

Page 472

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Nugg Co de

39

Pin Assignments for COM1 You should use a PC/AT compatible 8-pin D-Sub connector for the RS-232 serial cable. Pin

Signal

Direction From Terminal

1

Carrier Detect (CD)

Incoming

2

Received Data (RX)

Incoming

3

Transmitted Data (TX)

Outgoing

4

Data Terminal Ready (DTR)

Outgoing

5

Ground (GND)

6

Data Set Ready (DSR)

Incoming

7

Request to Send (RTS)

Outgoing

8

Clear to Send (CTS)

Incoming

9

Not Supported (NC)

Incoming

Modem Communications •

Direct RJ11 phone connection, up to 33600 baud

•

Supports Configurable Serial Protocol

•

XMODEM or YMODEM protocol for data transfer

Bar Code Symbologies

A-6

•

Codabar

•

Code 93

•

Code One

•

Code 128

•

Code 11

•

Interleaved 2 of 5

•

Code 16K

•

MSI

•

Code 2 of 5

•

PDF 417

•

Code 39

•

Plessey

•

Code 49

•

UPC/EAN

Page 473

Nugg

Co de

Terminal Specifications 39

A

Scan Module Options There are five scan module accessory options: •

Standard range scan module with integrated visible laser diode (670 nm)

•

Long range scan module with integrated visible laser diode (650 nm)

•

High visibility scan module

•

High density scan module

•

Module for cabled scanners

Standard Range Scan Module Optical Parameters Bar Code Specification

Depth of Field / Scanning Range

5.0 mil code

5 to 7 inches

12.7 to 17.8 cm

7.5 mil code

5 to 11 inches

12.7 to 27.9 cm

10 mil code

4 to 15 inches

10.2 to 38.1 cm

15 mil code

4 to 21 inches

10.2 to 53.3 cm

20 mil code

4 to 24 inches

10.2 to 61 cm

40 mil code

5 to 28 inches

12.7 to 71.1 cm

55 mil code

6 to 30 inches

15.2 to 76.2 cm

55 mil code, retroreflective

2 to 7 feet

61 cm to 2.1 m

100 mil code, retroreflective

3 to 13 feet

91.4 cm to 3.96 m

Long Range Scan Module Optical Parameters Bar Code Specification

Depth of Field/Scanning Range

10 mil code

11.6 to 19.6 inches

29.5 to 49.8 cm

15 mil code

8.6 to 33.6 inches

21.8 to 85.3 cm

20 mil code

8.6 to 38.6 inches

21.8 to 98.0 cm

40 mil code

9.6* inches to 6.3 feet

24.4* cm to 1.92 m

55 mil code

9.6* inches to 6.7 feet

24.4* cm to 2.04 m

70 mil code, retroreflective

6.3 to 13.5 feet

1.92 to 4.10 m

100 mil code, retroreflective

7 to 17.5 feet

2.12 to 5.32 m

*Near fields are governed by the width of the bar code. This number is based on a single digit Code 39 label.

A-7

Page 474

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Nugg Co de

39

High Visibility Scan Module Optical Parameters Bar Code Specification

Depth of Field/Scanning Range

5 mil code

3.5 to 5.0 inches

8.8 to 12.5 cm

7.5 mil code

2.5 to 8.0 inches

6.2 to 20.0 cm

10 mil code

2.4 to 9.6 inches

6.0 to 24.0 cm

15 mil code

2.1 to 14.6 inches

5.3 to 36.5 cm

20 mil code

2.6 to 19.6 inches

6.5 to 49.0 cm

40 mil code

4.6 to 31.6 inches

11.5 to 79.0 cm

55 mil code

7.1 to 35.6 inches

17.7 to 89.0 cm

High Density Scan Module Optical Parameters Bar Code Specification

Depth of Field/Scanning Range

2 mil code

1.5 to 2.4 inches

3.9 to 6.1 cm

3 mil code

2.1 to 3.3 inches

5.3 to 8.5 cm

4 mil code

2.3 to 4.0 inches

5.8 to 10.2 cm

5 mil code

2.1 to 5.3 inches

5.3 to 13.5 cm

7.5 mil code

2.1 to 5.3 inches

5.3 to 13.6 cm

13 mil code

2.1 to 6.4 inches

5.3 to 16.3 cm

Input Devices for the Module for Cabled Scanners You can attach these input devices to the module for cabled scanners:

A-8

•

Intermec 146X CCD scanners

•

Intermec 151X, 1545, and 155X laser scanners

•

Intermec 126X, 127X, and 128X wands

•

Tethered long range scanner

•

Compatible Symbol scanners (with reverse polarity enabled)