Page 475
Nugg
Co de
Terminal Specifications 39
A
Default Configuration The next tables show the terminal’s default configuration. You can use the TRAKKER Antares 2400 Menu System to set the terminal to the default configuration. For help, see “Restoring the Terminal’s Default Configuration” in Chapter 3.
Default Configuration for Bar Code Symbologies Parameter
Default
Codabar
Disabled
Code 11
Disabled
Code 16K
Disabled
Code 2 of 5
Disabled
Code 39
Enabled, full ASCII Code 39 enabled with no check digit
Code 49
Disabled
Code 93
Disabled
Code 128
Enabled, standard
Interleaved 2 of 5
Disabled
ISBT Code 128
Enabled, symbology ID disabled, concatenation disabled
MSI
Disabled
Plessey
Disabled
UPC/EAN
Enabled, UPC-A/EAN-13 enabled, UPC-E and EAN-8 enabled, supplementals allowed, transmit check digit, transmit number system digit, and retain leading zero for UPC-A
A-9
Page 476
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Nugg Co de
39
Default Configuration for Operations Parameter
Default
Append Time
Disabled
Automatic Shutoff
Disabled
Beep Volume
Very Loud
Command Processing
All reader commands enabled
Decode Security
Moderate
Display Backlight Timeout
10 seconds
Display Contrast
3 (maximum contrast)
Display Font Type
8x8 font (8 pixels wide by 8 pixels high)
Display Row Spacing
0 (one scan line)
Display Video Mode
Original
Flash Memory Configuration
Configure for double-byte fonts
Keypad Caps Lock
Caps lock off
Keypad Clicker
Enabled
Keypad Type
Hardware default
Postamble
No characters (disabled)
Preamble
No characters (disabled)
RAM Drive Size
No RAM drive
Resume Execution
Allowed
Scan Ahead
Disabled
Scanner Mode
One-Shot mode
Scanner Redundancy
Normal
Scanner Selection
All compatible scanners (see Note below)
Scanner Timeout
Disabled (no timeout)
Scanner Trigger
Level triggering
Suspend/Resume Control
Enabled
Time and Date
960101120000
Time in Seconds
Disabled
Note: The Scanner Selection command is only used when you have a module for cabled scanners, a long range scan module, or a high density scan module installed.
A-10
Page 477
Nugg
Co de
Terminal Specifications 39
A
Default Configuration for RF Network Communications (T2425 Only) Parameter
Default
Acknowledgement Delay Lower Limit
300 ms
Acknowledgement Delay Upper Limit
5000 ms
Controller Connect Check Receive Timer
60 seconds
Controller Connect Check Send Timer
35 seconds
Controller IP Address
0.0.0.0
Default Router
0.0.0.0
Dynamic Host Configuration Protocol
Disabled
Host IP Address
0.0.0.0
Maximum Retries
7
Network Activate
Disabled
Network Loopback
Disabled
Network Port
23 (Telnet) for a TCP/IP network 5555 for a UDP Plus network
RF Domain
0
RF Inactivity Timeout
5 seconds
RF Roaming Flag
Allowed
RF Security Identification (ID)
No characters
RF Transmit Mode
BFSK
RF Wakeup On Broadcast
Disabled
Subnet Mask
255.255.255.0
TCP Maximum Retries
12
TCP/IP Maximum Transmit Timeout
20 seconds
Terminal IP Address
0.0.0.0
A-11
Page 478
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Nugg Co de
39
Default Configuration for Serial (RS-232) Network Communications
A-12
Parameter
Default
Baud Rate
19200
Configuration Commands Via Serial Port
Enabled without TMF
Data Bits
7
End of Message (EOM)
\x03 (hexadecimal value for ETX)
Flow Control
None
Handshake
Disabled
LRC (Longitudinal Redundancy Check)
Disabled
Modem Dial Sequence
None
Modem Initialization Sequence
Auto rate
Parity
Even
Poll (Polling)
Disabled
Serial Port Protocol
Configurable
Start of Message (SOM)
\x02 (hexadecimal value for STX)
Stop Bits
1
Timeout Delay
10 seconds
Page 479
Nugg
Co de
Terminal Specifications 39
A
Configuration Commands by Syntax The next table lists all of the configuration commands that are available on the TRAKKER Antares 2420 and 2425 terminals. The configuration commands are listed in alphabetic order by syntax. Syntax
Command
ADdata
Preamble
AEdata
Postamble
BVdata
Beep Volume
CAdata
Interleaved 2 of 5 Code (I 2 of 5)
CBdata
Code 39
CCdata
Code 2 of 5 (2 of 5)
CDdata
Codabar
CEdata
UPC/EAN
CFdata
Code 93
CGdata
Code 11
CHdata
Code 128
CH8data
ISBT Code 128
CIdata
Plessey
CJdata
Code 49
CKdata
Code 49 Function Code 1
CLdata
Code 49 Function Code 2
CMdata
Code 49 Function Code 3
CNdata
MSI
CPdata
Code 16K
CSdata
Decode Security
DAdata
Time in Seconds
DBdata
Time and Date
DCdata
Command Processing
DEdata
Append Time
DFdata
Display Backlight Timeout
DJdata
Display Contrast
DLdata
Display Row Spacing
DNdata
Display Video Mode
A-13
Page 480
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Nugg Co
Configuration Commands by Syntax (continued)
A-14
Syntax
Command
DTdata
Display Font Type
EFdata
Suspend/Resume Control
ERdata
Resume Execution
EZdata
Automatic Shutoff
FFdata
Flash Memory Configuration
FRdata
RAM Drive Size
KAdata
Keypad Caps Lock
KCdata
Keypad Clicker
KTdata
Keypad Type
NAdata
Network Activate
NCdata
Controller IP Address (UDP Plus network)
NCdata
Host IP Address (TCP/IP network)
NDdata
Terminal IP Address
NGdata
Network Port
NHdata
TCP/IP Maximum Transmit Timeout
NIdata
Dynamic Host Configuration Protocol (DHCP)
NJdata
TCP Maximum Retries
NLdata
Network Loopback
NPdata
Controller Connect Check Receive Timer
NQdata
Controller Connect Check Send Timer
NRdata
Maximum Retries
NSdata
Subnet Mask
NUdata
Acknowledgement Delay Upper Limit
NVdata
Acknowledgement Delay Lower Limit
NXdata
Default Router
RBdata
RF Wakeup On Broadcast
RRdata
RF Roaming Flag
RSdata
RF Security Identification
RTdata
RF Transmit Mode
RWdata
RF Domain de
39
Page 481
Nugg
Co de
Terminal Specifications 39
A
Configuration Commands by Syntax (continued) Syntax
Command
RYdata
RF Inactivity Timeout
SAdata
Scanner Timeout
SBdata
Scanner Mode
SCdata
Scanner Trigger
SDdata
Scan Ahead
SRdata
Scanner Redundancy
SSdata
Scanner Selection
YAn.data
Baud Rate
YBn.data
Parity
YCn.data
Stop Bits
YDn.data
Modem Dial Sequence
YEn.data
Timeout Delay
YFn.data
LRC (Longitudinal Redundancy Check)
YIn.data
Data Bits
YJn.data
Handshake (also know as AFF)
YLn.data
Flow Control
YMn.data
Modem Initialization Sequence
YRn.data
Poll (Polling)
YTn.data
Configuration Commands Via Serial Port
YUn.data
Serial Port Protocol
YYn.data
Start of Message (SOM)
YZn.data
End of Message (EOM)
A-15
Page 482
A-16