For the Intermec 2420 and Intermec 2425
Page 457
Co de
39 Nugget Configuration Command Reference
9
2. Scan a numeric value for data from these bar codes:
*0* *0*
*2*
*1* *1*
*3*
*2*
*3*
*4*
*5*
*4*
*6* *6*
*8* *8*
*5*
*7*
*7*
*9*
*9*
3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
9-111
Page 458
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de
39 Nugget
Terminal IP Address Purpose:
Defines the IP address assigned to the T2425 in your 2.4 GHz RF network. An IP address is a unique network level address you assign to each device in a TCP/IP network. The IP address you set on the T2425 must match the address that is set on the DCS 300 or host computer.
Syntax:
NDn.n.n.n where each n address segment is a number from 0 to 255. The terminal IP address field consists of four separate numbers, each separated by a period. Note: The RF network cannot be activated if the first address segment in the IP address is set to 0, 127, or a number greater than 223.
Default: Scan:
0.0.0.0 To set the default terminal IP address, scan this bar code: Default Terminal IP Address
*$+ND0.0.0.0* *$+ND0.0.0.0*
Or:
To set the terminal IP address: 1. Scan this bar code: Enter Accumulate Mode / Set Terminal IP Address
*+/$+ND* *+/$+ND*
2. Scan a numeric value from 0 to 255 to set an n field of the terminal IP address from these bar codes.
*0* *0*
*2*
*1*
*3*
*2*
*3*
*4*
*5*
*4*
9-112
*1*
*5*
Page 459
Co de
39 Nugget Configuration Command Reference
*6* *6*
*8* *8*
9
*7*
*7*
*9*
*9*
3. Scan this bar code: . (Period)
*.* *.*
4. Repeat Steps 2 and 3 to set the next three numbers in the terminal IP address field. After you scan the last address segment, go to Step 5. Do not scan the period after the last address segment. 5. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
9-113
Page 460
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de
39 Nugget
Time and Date Purpose:
Sets the time and date on the terminal.
Syntax:
DBdata Acceptable values for data are 12 digits corresponding to: yy mm dd hh mm ss
00-99 01-12 01-31 00-23 00-59 00-59
Year Month of the year Day of the month Hour Minutes Seconds
Year values (yy) from 00 to 95 are interpreted as 2000 through 2095. Year values from 96 to 99 are interpreted as 1996 through 1999. Default: Scan:
960101120000 To set the time and date: 1. Scan this bar code: Enter Accumulate Mode / Set Time and Date
*+/$+DB* *+/$+DB*
2. Scan a numeric value for each digit from these bar codes:
*0* *0*
*2*
*1*
*3*
*2*
*3*
*4*
*5*
*4*
*6* *6*
*8* *8*
9-114
*1*
*5*
*7*
*7*
*9*
*9*
Page 461
Co de
39 Nugget Configuration Command Reference
9
3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
Time in Seconds Purpose:
If you enable the Append Time command, you can enable the Time in Seconds command to append the seconds to each bar code label that is scanned on the terminal. To append the time in hours and minutes, disable the Time in Seconds command.
Syntax:
DAdata Acceptable values for data are: 0 1
Default: Scan:
Disabled Enabled
Disabled One of these bar codes: Disable Time in Seconds
*$+DA0* *$+DA0*
Enable Time in Seconds
*$+DA1*
*$+DA1*
9-115
Page 462
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de
39 Nugget
Timeout Delay Purpose:
If handshaking is enabled, the terminal expects a response to each message that is sent to the host through the serial port. The timeout delay is the amount of time the terminal waits to receive a response. When the timeout expires, the terminal tries sending the message again. If no response is received after the terminal tries to send the message three times, a timeout error occurs. In polling mode D, the terminal sends another poll sequence when it resends the message. Note: Before you can enable Timeout Delay, you must configure the EOM and Handshake commands.
Syntax:
YEn.data where n is: 1 3 4
COM1 port COM3 port COM4 port
Acceptable values for data are: 0 1 2 3 4 5 6 7 Default: Scan:
5 ms 100 ms 500 ms 2 sec 10 sec 20 sec 40 sec 60 sec
10 seconds To set the default timeout delay, scan one of these bar codes: Timeout Delay 10 sec for COM1
Timeout Delay 10 sec for COM1
*$+YE1.4*
*$+YE3.4*
*$+YE1.4*
Timeout Delay 10 sec for COM4
*$+YE4.4* *$+YE4.4*
9-116
*$+YE3.4*
Page 463
Co Or:
de
39 Nugget Configuration Command Reference
9
To set the timeout delay for one serial port: 1. Scan this bar code: Enter Accumulate Mode / Set Timeout Delay
*+/$+YE* *+/$+YE*
2. Scan the serial port from these bar codes: COM1
*1.* *1.*
COM3
*3.*
*3.*
COM4
*4.* *4.*
3. Scan the timeout delay from these bar codes: Timeout Delay 5 ms
Timeout Delay 100 ms
*0*
*1*
Timeout Delay 500 ms
Timeout Delay 2 sec
*0*
*2*
*1*
*3*
*2*
*3*
Timeout Delay 10 sec
Timeout Delay 20 sec
*4*
*5*
Timeout Delay 40 sec
Timeout Delay 60 sec
*4*
*6* *6*
*5*
*7*
*7*
4. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
5. Repeat Steps 1 through 4 to set the timeout delay for another serial port.
9-117
Page 464
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de
39 Nugget
Timeout Delay (continued) Notes:
For COM1 only. To provide compatibility with earlier TRAKKER Antares firmware versions, you can also use this syntax: IEdata where data is value from 0 to 7.
UPC/EAN Purpose:
Enables or disables the decoding of Universal Product Code (UPC)/European Article Numbering (EAN) symbology. UPC/EAN are fixed length, numeric, continuous symbologies that use four element widths. A terminal that is configured to decode EAN bar codes can decode UPC, but the reverse is not true. UPC code is a subset of EAN code. To define the UPC/EAN symbology, you set up to seven digits. The fifth, sixth, and seventh digits are optional. To set the sixth digit, you must set the fifth digit. To set the seventh digit, you must set all seven digits.
Syntax:
CEdata where data must be 4 to 7 digits selected from this list:
9-118
First digit:
0 1 2
UPC-A/EAN-13 disabled UPC-A/EAN-13 enabled UPC-A only enabled
Second digit:
0 1
UPC-E disabled UPC-E enabled
Third digit:
0 1
EAN-8 disabled EAN-8 enabled
Fourth digit:
0 1
Supplementals are not allowed Supplementals are allowed
Fifth digit:
0 1
Discard check digit Transmit check digit
Sixth digit:
0 1
Discard number system digit Transmit number system digit
Seventh digit:
0 1
Discard the leading zero for UPC-A Retain the leading zero for UPC-A
Page 465
Co Default:
de
9
1111111 First digit: Second digit: Third digit: Fourth digit: Fifth digit: Sixth digit: Seventh digit:
Scan:
39 Nugget Configuration Command Reference
UPC-A/EAN-13 enabled UPC-E enabled EAN-8 enabled Supplementals allowed Transmit check digit Transmit number system digit Retain leading zero for UPC-A
To disable UPC/EAN, scan this bar code: Disable UPC/EAN
*$+CE0000000* *$+CE0000000*
Or:
To enable UPC/EAN: 1. Scan this bar code: Enter Accumulate Mode / Enable UPC/EAN
*+/$+CE* *+/$+CE*
2. Scan one of these bar codes to set the first digit: Disable UPC/EAN-13
Enable UPC/EAN-13
*0*
*1*
*0*
*1*
Enable UPC-A Only
*2* *2*
3. Scan one of these bar codes to set the second digit: Disable UPC-E
Enable UPC-E
*0*
*1*
*0*
*1*
4. Scan one of these bar codes to set the third digit: Disable EAN-8
Enable EAN-8
*0*
*1*
*0*
*1*
9-119
Page 466
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de
39 Nugget
UPC/EAN (continued) 5. Scan one of these bar codes to set the fourth digit: Supplementals Not Allowed
Supplementals Allowed
*0*
*1*
*0*
*1*
6. (Optional) Scan one of these bar codes to set the fifth digit: Discard Check Digit
Transmit Check Digit
*0*
*1*
*0*
*1*
7. (Optional) Scan one of these bar codes to set the sixth digit: Discard Number System Digit
Transmit Number System Digit
*0*
*1*
*0*
*1*
Note: If you discard the number system digit, one leading digit is discarded from UPC-A, UPC-E, and EAN-8, and two leading digits are discarded from EAN-13. 8. (Optional) Scan one of these bar codes to set the seventh digit: Discard Leading Zero for UPC-A
Transmit Leading Zero for UPC-A
*0*
*1*
*0*
*1*
Note: This option applies only when you enable UPC-A/EAN-13. 9. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
9-120