Page 417

Co de

39 Nugget Configuration Command Reference

9

Modem Dial Sequence Purpose:

Defines the dialing sequence that is used when the terminal establishes a modem connection.

Syntax:

YD3.data where data can be up to 25 characters from this table.

Default: Scan:

Character

Description

0-9

DTMF digits 0 through 9

A-D

DTMF letters A through D

*

The star digit (tone dialing only)

#

The gate digit (tone dialing only)

W

Wait for dial tone

@

Wait for silence

&

Wait for credit card dialing tone

,

Pause

(

Ignored. You can use this character to format the dial sequence.

)

Ignored. You can use this character to format the dial sequence.

-

Ignored. You can use this character to format the dial sequence.

.

Ignored. You can use this character to format the dial sequence.

<space>

Ignored. You can use this character to format the dial sequence.

0 (no dial sequence) To set the default modem dial sequence, scan this bar code: Default Modem Dial Sequence

*$+YD3* *$+YD3*

Or:

To set the modem dial sequence for COM3: 1. Scan this bar code: Enter Accumulate Mode / Set Modem Dial Sequence

*+/$+YD3* *+/$+YD3*

9-71

Page 418

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

39 Nugget

Modem Dial Sequence (continued) 2. Scan a value for data from the “Full ASCII Bar Code Chart” in Appendix B. The modem dial sequence can be from 1 to 25 characters. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

9-72

Page 419

Co de

39 Nugget Configuration Command Reference

9

Modem Initialization Sequence Purpose:

Defines an initialization string that the terminal sends to the modem before the modem dial sequence.

Syntax:

YM3.data where data can be up to 25 characters from this table.

Default: Scan:

Character

Description

0-9

DTMF digits 0 through 9

A-D

DTMF letters A through D

*

The star digit (tone dialing only)

#

The gate digit (tone dialing only)

W

Wait for dial tone

@

Wait for silence

&

Wait for credit card dialing tone

,

Pause

(

Ignored. You can use this character to format the dial sequence.

)

Ignored. You can use this character to format the dial sequence.

-

Ignored. You can use this character to format the dial sequence.

.

Ignored. You can use this character to format the dial sequence.

<space>

Ignored. You can use this character to format the dial sequence.

0 (auto rate) To set the default modem initialization sequence, scan this bar code: Default Modem Initialization Sequence

*$+YM3* *$+YM3*

Or:

To set the modem dial sequence for COM3: 1. Scan this bar code: Enter Accumulate Mode / Set Modem Initialization Sequence

*+/$+YM3* *+/$+YM3*

9-73

Page 420

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

39 Nugget

Modem Initialization Sequence (continued) 2. Scan a value for data from the “Full ASCII Bar Code Chart” in Appendix B. The modem dial sequence can be from 1 to 25 characters. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

9-74

Page 421

Co de

39 Nugget Configuration Command Reference

9

MSI Purpose:

Enables or disables decoding of MSI symbology. MSI code is similar to Plessey code in that it includes a start pattern, data characters, 1 or 2 check digits, and a stop pattern.

Syntax:

CNdata Acceptable values for data are:

Default: Scan:

First digit:

0 1 2 3

Disabled No check digits 1 modulus 10 check digit 2 modulus 10 check digit

Second digit:

0 1

Discard check digit Transmit check digit

Disabled One of these bar codes: Disable MSI

*$+CN00* *$+CN00*

MSI Without Check Digits

*$+CN10* *$+CN10*

MSI With 1 Modulus 10 Check Digit, Discard Check Digit

*$+CN20* *$+CN20*

MSI With 1 Modulus 10 Check Digit, Transmit Check Digit

*$+CN21* *$+CN21*

MSI With 2 Modulus 10 Check Digits, Discard Check Digits

*$+CN30* *$+CN30*

MSI With 2 Modulus 10 Check Digits, Transmit Check Digits

*$+CN31*

*$+CN31*

9-75

Page 422

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

39 Nugget

Network Activate Purpose:

Enables or disables network communications between the T2425 and other devices in the 2.4 GHz RF network. When you enable this parameter, the terminal attempts to establish communications with the DCS 300 or host computer. When you disable this parameter, the network is disabled, no RF communications are provided, and the radio is turned off. Note: You must enable the Network Activate parameter to use the T2425 for RF data collection.

Syntax:

NAdata Acceptable values for data are: 0 1

Default: Scan:

Disabled 2.4 GHz RF network (enabled)

Disabled One of these bar codes: Disable Network Activate

*$+NA0* *$+NA0*

9-76

Enable 2.4 GHz RF Network

*$+NA1*

*$+NA1*

Page 423

Co de

39 Nugget Configuration Command Reference

9

Network Loopback Purpose:

Transmits all messages received from the DCS 300 back to the DCS 300. Messages received by the radio are not passed on to the T2425 applications unless they are configuration commands. Messages continue to be looped back to the DCS 300 as long as this feature is enabled. Messages originating from the T2425 are still transmitted to the DCS 300. Use the Network Loopback parameter to troubleshoot RF communications problems.

Syntax:

NLdata Acceptable values for data are: 0 1

Default: Scan:

Disabled Enabled

Disabled One of these bar codes: Disable Network Loopback

*$+NL0* *$+NL0*

Enable Network Loopback

*$+NL1*

*$+NL1*

9-77

Page 424

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

39 Nugget

Network Port Purpose:

Defines the network port that the TCP/IP or UDP Plus network protocol uses for communications in your 2.4 GHz RF network. In a TCP/IP network, set the network port to the appropriate port for the application you are using on the T2425. The default network port of 23 enables VT/ANSI Telnet communications. In a UDP Plus network, the network port you set on the T2425 must match the network port that is set on the DCS 300.

Syntax:

NGdata Acceptable values for data are any number from 1 to 65535.

Default:

Scan:

00023 05555

T2425 with TCP/IP T2425 with UDP Plus

To set the default network port for a T2425 with TCP/IP, scan this bar code: Default TCP/IP Network Port

*$+NG23* *$+NG23*

To set the default network port for a T2425 with UDP Plus, scan this bar code: Default UDP Plus Network Port

*$+NG5555* *$+NG5555*

Or:

To set the network port: 1. Scan this bar code: Enter Accumulate Mode / Set Network Port

*+/$+NG* *+/$+NG*

2. Scan a numeric value for data from these bar codes:

*0* *0*

*2* *2*

9-78

*1* *1*

*3*

*3*

Page 425

Co de

39 Nugget Configuration Command Reference

*4* *4*

*6* *6*

*8* *8*

9

*5* *5*

*7*

*7*

*9*

*9*

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

9-79

Page 426

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

39 Nugget

Parity Purpose:

Sets the parity for the serial port. The terminal uses parity for error checking in data transmissions.

Syntax:

YBn.data where n is: 1 3 4

COM1 port COM3 port COM4 port

Acceptable values for data are: 0 1 2 Default: Scan:

No parity Even parity Odd parity

Even One of these bar codes: No Parity for COM1

Even Parity for COM1

*$+YB1.0*

*$+YB1.1*

*$+YB1.0*

*$+YB1.1*

Odd Parity for COM1

*$+YB1.2* *$+YB1.2*

No Parity for COM3

*$+YB3.0* *$+YB3.0*

Odd Parity for COM3

*$+YB3.2* *$+YB3.2*

9-80

Even Parity for COM3

*$+YB3.1*

*$+YB3.1*