Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 51 of 64

Trakker Antares 24XX Terminal User's Manual Addendum, with the Trakker Antares 2420 and 2425 Hand-Held Terminal User's Manual: Chapter 9 - Configuration Command Reference, pages 427 to 436

Pages 427 to 436 of 558, from Trakker Antares 24XX Terminal User's Manual Addendum, with the Trakker Antares 2420 and 2425 Hand-Held Terminal User's Manual

The original document is the PDF (4.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 2420 and Intermec 2425

Page 427

Co de

39 Nugget Configuration Command Reference

No Parity for COM4

*$+YB4.0* *$+YB4.0*

9

Even Parity for COM4

*$+YB4.1*

*$+YB4.1*

Odd Parity for COM4

*$+YB4.2* *$+YB4.2*

Notes:

For COM1 only. To provide compatibility with earlier TRAKKER Antares firmware versions, you can also use this syntax: IBdata where data is a value from 0 to 2.

9-81

Page 428

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

39 Nugget

Plessey Purpose:

Enables or disables decoding of Plessey symbology. Plessey code is pulse-width modulated like most other bar codes. It includes a start character, data characters, an eight-bit cyclic check digit, a termination bar, and usually a reverse start character. The code is continuous and not self-checking. You need to configure two parameters for Plessey code: Start Code and Check Digit.

Syntax:

CIdata Acceptable values for data are: 00 Disabled 10 Plessey with reverse start code 30 Transmit check digit 31 Discard check digit

Default: Scan:

Disabled To disable Plessey: Disable Plessey

*$+CI00* *$+CI00*

Or:

To set Plessey, complete these steps: 1. Scan this bar code: Plessey With Reverse Start Code

*$+CI10* *$+CI10*

2. Scan one of these bar codes to transmit or retain the check digit: Transmit Check Digit

Discard Check Digit

*$+CI30*

*$+CI31*

*$+CI30*

9-82

*$+CI31*

Page 429

Co de

39 Nugget Configuration Command Reference

9

Poll (Polling) Purpose:

Solicits or requests data from a polled device. Note: Before you can enable Poll, you must configure the EOM and Handshake commands.

Syntax:

YRn.data where n is: 1 3 4

COM1 port COM3 port COM4 port

Acceptable values for data are: Disabled Enabled Default: Scan:

No polling Set to FS (hexadecimal value of \x1C)

Disabled To disable poll, scan one of these bar codes: Note: To scan these bar code labels, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” earlier in this chapter. Disable Poll for COM1

*/D/KYR1.*

*/D/KYR1.%B*

*$+YR1.*

*$+YR1.%B*

Disable Poll for COM3

Enable Poll (Set to FS) for COM3

*/D/KYR3.*

*/D/KYR3.%B*

Disable Poll for COM4

Enable Poll (Set to FS) for COM4

*/D/KYR4.*

*/D/KYR4.%B*

*$+YR3.*

*$+YR4.*

Notes:

Enable Poll (Set to FS) for COM1

*$+YR3.%B*

*$+YR4.%B*

For COM1 only. To provide compatibility with earlier TRAKKER Antares firmware versions, you can also use this syntax: HBdata where data is disabled or enabled (set to FS).

9-83

Page 430

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

39 Nugget

Postamble Purpose:

Sets the postamble that is appended to any data you scan with the terminal. Common postambles include cursor controls such as a tab or a carriage return line feed. You can set the postamble to use characters from the extended ASCII character set such as the Field Exit code for 5250 TE. However, you cannot scan in extended ASCII characters in the Postamble command. You need to use the TRAKKER Antares 2400 Menu System. For help, see “Entering ASCII Control Characters” in Chapter 3.

Syntax:

AEdata Acceptable values for data are up to 25 ASCII characters. If you enter the AE command without data, the postamble is disabled. If you are entering quotation marks as data or grouping configuration commands, you need to enclose the data within quotation marks (see the example).

Default: Scan:

No characters (disabled) To disable the postamble, scan this bar code: Disable Postamble

*$+AE* *$+AE*

Or:

To set the postamble to an ASCII character string: 1. Scan this bar code: Enter Accumulate Mode / Set Postamble

*+/$+AE* *+/$+AE*

2. Scan a value for data from the “Full ASCII Bar Code Chart” in Appendix B. The postamble can be from 1 to 25 characters. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

9-84

Page 431

Co Example:

de

39 Nugget Configuration Command Reference

9

You want to set a postamble that includes quotation marks. To scan a bar code label that includes quotation marks, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” earlier in this chapter. Enter the postamble by scanning this full ASCII bar code label: Set Postamble to “B”

*/D/KAE/B/B/BB/B/B/B* *$+AE"""B"""*

You must enclose the data within quotation marks and precede each quotation mark with another quotation mark so that the quotation marks are not treated as the end of the data.

Preamble Purpose:

Sets the preamble that precedes any data you scan with the terminal. Common preambles include a data location number or an operator number. You can set the preamble to use characters from the extended ASCII character set. However, you cannot scan in extended ASCII characters in the Preamble command. You need to use the TRAKKER Antares 2400 Menu System. For help, see “Entering ASCII Control Characters” in Chapter 3.

Syntax:

ADdata Acceptable values for data are up to 25 ASCII characters. When you enter the AD command without data, the preamble is disabled. If you are entering quotation marks as data or grouping configuration commands, you need to enclose the data within quotation marks (see the example).

Default: Scan:

No characters (disabled) To disable the preamble, scan this bar code: Disable Preamble

*$+AD* *$+AD*

Or:

To set the preamble to an ASCII character string: 1. Scan this bar code: Enter Accumulate Mode / Set Preamble

*+/$+AD* *+/$+AD*

9-85

Page 432

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

39 Nugget

Preamble (continued) 2. Scan a value for data from the “Full ASCII Bar Code Chart” in Appendix B. The preamble can be from 1 to 25 characters. Note: To scan a bar code label that includes quotes, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” earlier in this chapter. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

Example:

You want to set a preamble that includes quotation marks. To scan a bar code label that includes quotation marks, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” earlier in this chapter. Enter the preamble by scanning this full ASCII bar code label: Set Preamble to “B”

*/D/KAD/B/B/BB/B/B/B* *$+AD"""B"""*

You must enclose the data within quotation marks and precede each quotation mark with another quotation mark so that the quotation marks are not treated as the end of the data.

9-86

Page 433

Co de

39 Nugget Configuration Command Reference

9

RAM Drive Size Purpose:

Configures the size and use of the RAM drive (E). You can disable the RAM drive and use the additional 256K for programmable (Malloc) memory allocations or configure the RAM drive to temporarily store data and files. After you set the RAM drive, you must save the configuration in flash memory and boot the terminal for the change to take effect. Note: When you boot or reset the terminal, all files on the RAM drive are destroyed.

Syntax:

FRdata Acceptable values for data are: 0 16-256

Default: Scan:

Disabled, no RAM drive RAM drive size in kilobytes (K)

Disabled, no RAM drive To disable the RAM drive, scan this bar code: Disable RAM Drive

*$+FR0* *$+FR0*

Or:

To set the RAM drive size: 1. Scan this bar code: Enter Accumulate Mode / Set RAM Drive Size

*+/$+FR* *+/$+FR*

9-87

Page 434

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

39 Nugget

RAM Drive Size (continued) 2. Scan a numeric value for data from these bar codes:

*0* *0*

*2*

*1* *1*

*3*

*2*

*3*

*4*

*5*

*4*

*6* *6*

*8* *8*

*5*

*7*

*7*

*9*

*9*

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

4. Scan this bar code to save the configuration change in flash memory: Save Configuration in Flash Memory

*.+1* *.+1*

5. Scan this bar code to boot the terminal and use the RAM drive: Reset Firmware

*-.* *-.*

9-88

Page 435

Co de

39 Nugget Configuration Command Reference

9

Resume Execution Purpose:

L

L

Defines the way in which the terminal resumes when you press to turn on the terminal. If you set this parameter to resume execution not allowed and you press to turn on the terminal, the terminal will boot and restart the application that was running when you turned off the terminal. If you set this parameter to resume execution allowed and press to turn on the terminal, the terminal resumes exactly where it was when you turned off the terminal.

L Syntax:

ERdata Acceptable values for data are: 0 1

Default: Scan:

Not allowed Allowed

Allowed One of these bar codes: Resume Execution Not Allowed

Resume Execution Allowed

*$+ER0*

*$+ER1*

*$+ER0*

*$+ER1*

9-89

Page 436

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

39 Nugget

RF Domain Purpose:

Defines a logical partition or subnetwork of the network. To establish communications, you must assign the same domain number to every RF device in a wireless network. The domain number you set on the T2425 must match the domain that is set on each access point the T2425 may communicate with. You can continue to collect data with the T2425 as you roam in between access points as long as all the devices have the same domain number.

Syntax:

RWdata Acceptable values for data are any number from 0 to 15.

Default: Scan:

0 1. Scan this bar code: Enter Accumulate Mode / Set RF Domain

*+/$+RW* *+/$+RW*

2. Scan a numeric value for data from these bar codes:

*0* *0*

*2*

*1*

*3*

*2*

*3*

*4*

*5*

*4*

*6* *6*

*8* *8*

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

9-90

*1*

*5*

*7*

*7*

*9*

*9*