Page 407

Co de

39 Nugget Configuration Command Reference

9

Handshake Purpose:

Enables or disables the handshake event that is an affirmative acknowledge to a message received through the serial port. Note: Before you can enable Handshake, you must configure the EOM command. Handshake is also referred to as AFF (affirmative acknowledge) on other Intermec devices.

Syntax:

YJn.data where n is: 1 3 4

COM1 port COM3 port COM4 port

Acceptable values for data are: Disabled Enabled Default: Scan:

No ACK or NAK transmitted Set to ACK (hexadecimal value of \x06)

Disabled One of these bar codes: Note: To scan these bar code labels, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” earlier in this chapter. Disable Handshake for COM1

*/D/KYJ1.*

*/D/KYJ1.$F*

*$+YJ1.*

*$+YJ1.$F*

Disable Handshake for COM3

Enable Handshake (Set to ACK) for COM3

*/D/KYJ3.*

*/D/KYJ3.$F*

Disable Handshake for COM4

Enable Handshake (Set to ACK) for COM4

*/D/KYJ4.*

*/D/KYJ4.$F*

*$+YJ3.*

*$+YJ4.*

Notes:

Enable Handshake (Set to ACK) for COM1

*$+YJ3.$F*

*$+YJ4.$F*

For COM1 only. To provide compatibility with earlier TRAKKER Antares firmware versions, you can also use this syntax: PGdata where data is disabled or enabled (set to ACK).

9-61

Page 408

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

39 Nugget

Host IP Address Purpose:

Defines the IP address assigned to the host computer in your 2.4 GHz RF network. An IP address is a unique network level address you assign to each device in a TCP/IP direct connect network. The host IP address you set on the T2425 must match the address that is set on the host.

Syntax:

NCn.n.n.n where each n address segment is a number from 0 to 255. The host IP address field consists of four separate numbers, each separated by a period. Note: The RF network cannot be activated if the first address segment in the IP address is set to 0, 127, or a number greater than 223.

Default: Scan:

0.0.0.0 To set the default host IP address, scan this bar code: Default Host IP Address

*$+NC0.0.0.0* *$+NC0.0.0.0*

Or:

To set the host IP address: 1. Scan this bar code: Enter Accumulate Mode / Set Host IP Address

*+/$+NC* *+/$+NC*

2. Scan a numeric value from 0 to 255 to set an n field of the host IP address from these bar codes.

*0* *0*

*2*

*1*

*3*

*2*

*3*

*4*

*5*

*4*

*6* *6*

9-62

*1*

*5*

*7*

*7*

Page 409

Co de

39 Nugget Configuration Command Reference

*8* *8*

9

*9*

*9*

3. Scan this bar code: . (Period)

*.* *.*

4. Repeat Steps 2 and 3 to set the next three numbers in the host IP address field. After you scan the last address segment, go to Step 5. Do not scan the period after the last address segment. 5. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

9-63

Page 410

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

39 Nugget

Interleaved 2 of 5 Purpose:

Enables or disables decoding of Interleaved 2 of 5 (I 2 of 5) symbology. I 2 of 5 is a high-density, self-checking, continuous numeric symbology. It is mainly used in inventory distribution and the automobile industry. Enabling I 2 of 5 automatically disables Code 2 of 5.

Syntax:

CAdata Acceptable values for data are: 0 2-32 97 98 99

Disabled Fixed length (even number only) Variable length without a check digit Case code (6 or 14) with a check digit Variable length with a check digit

Caution Using the variable length without a check digit configuration option can cause substitution errors. Conseil Des erreurs de substitution peuvent survenir si vous utilisez la longueur variable sans option de vérification de configuration de chiffres. Default: Scan:

Disabled One of these bar codes: Disable Interleaved 2 of 5

Enable Variable Length Without a Check Digit

*$+CA0*

*$+CA97*

Enable Variable Length With a Check Digit

Enable Case Code With a Check Digit

*$+CA0*

*$+CA99* *$+CA99*

9-64

*$+CA97*

*$+CA98*

*$+CA98*

Page 411

Co Or:

de

39 Nugget Configuration Command Reference

9

To set Interleaved 2 of 5 to a fixed length: 1. Scan this bar code: Enter Accumulate Mode / Set Fixed Length

*+/$+CA* *+/$+CA*

2. Scan a numeric value for data from these bar codes. (Use even numbers 2-32 only.)

*0* *0*

*2*

*1* *1*

*3*

*2*

*3*

*4*

*6*

*4*

*6*

*8* *8*

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

9-65

Page 412

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

39 Nugget

Keypad Caps Lock Purpose:

Turns the caps lock on and off. With the caps lock turned on, all alphabetic characters you type on the keypad will be uppercase or capital letters.

Syntax:

KAdata Acceptable values for data are: 0 1

Default: Scan:

Caps lock off Caps lock on

Caps lock off One of these bar codes: Caps Lock Off

Caps Lock On

*$+KA0*

*$+KA1*

*$+KA0*

*$+KA1*

Keypad Clicker Purpose:

Enables or disables the keypad clicker. The terminal sounds a click each time you press a key or decode a row of a two-dimensional symbology. Note: If the Beep Volume command is set to off, you will not hear any audio signals including the keyclick.

Syntax:

KCdata Acceptable values for data are: 0 1

Default: Scan:

Disable keypad clicker Enable keypad clicker

Enabled One of these bar codes: Disable Keypad Clicker

Enable Keypad Clicker

*$+KC0*

*$+KC1*

*$+KC0*

9-66

*$+KC1*

Page 413

Co de

39 Nugget Configuration Command Reference

9

Keypad Type Purpose:

The keypad type is initially configured in the terminal’s firmware at the Intermec factory. If you change the keypad overlay, you must configure the keypad type to match the new keypad overlay. After you change the keypad type, you must save the configuration in flash memory and boot the terminal for the change to take effect. Note: With the programmable keypad, you can access all the characters in the “TRAKKER Antares Terminal Font Set” in Appendix C.

Syntax:

KTdata Acceptable values for data are: 0 1 2

Default: Scan:

Hardware (factory) default Terminal emulation keypad Programmable (English or European) keypad

Hardware default 1. Scan one of these bar codes: Set Keypad Type to Hardware Default

Set Keypad Type to TE Keypad

*$+KT0*

*$+KT1*

*$+KT0*

*$+KT1*

Set Keypad Type to Programmable Keypad

*$+KT2* *$+KT2*

2. Scan this bar code to save the configuration change in flash memory: Save Configuration in Flash Memory

*.+1* *.+1*

3. Scan this bar code to boot the terminal and use the new keypad type: Reset Firmware

*-.* *-.*

9-67

Page 414

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

39 Nugget

LRC (Longitudinal Redundancy Check) Purpose:

The Longitudinal Redundancy Check (LRC) character is an error-checking character that you can append to transmitted and received blocks of data. Note: Before you can enable LRC, you must enable the EOM command.

Syntax:

YFn.data where n is: 1 3 4

COM1 port COM3 port COM4 port

Acceptable values for data are: 0 1 Default: Scan:

LRC disabled LRC enabled

Disabled One of these bar codes: Disable LRC for COM1

*$+YF1.0*

*$+YF1.1*

Disable LRC for COM3

Enable LRC for COM3

*$+YF3.1*

*$+YF3.0*

*$+YF3.1*

Disable LRC for COM4

Enable LRC for COM4

*$+YF4.0* *$+YF4.0*

*$+YF4.1*

*$+YF4.1*

For COM1 only. To provide compatibility with earlier TRAKKER Antares firmware versions, you can also use this syntax: IFdata where data is a value of 0 or 1.

9-68

*$+YF1.1*

*$+YF1.0*

*$+YF3.0*

Notes:

Enable LRC for COM1

Page 415

Co de

39 Nugget Configuration Command Reference

9

Maximum Retries Purpose:

Defines the number of times the T2425 will attempt to send a disconnect request message to the DCS 300. The T2425 sends connect and disconnect request messages to the DCS 300 when you turn the terminal on and off. Tip: Intermec strongly recommends that you use the optimum setting of 7 retries.

Syntax:

NRdata Acceptable values for data are: 0 1-99

Default: Scan:

T2425 retries indefinitely Number of retries

7 To set the default number of maximum retries, scan this bar code: Default Maximum Retries

*$+NR7* *$+NR7*

Or:

To set the maximum retries: 1. Scan this bar code: Enter Accumulate Mode / Set Maximum Retries

*+/$+NR* *+/$+NR*

2. Scan a numeric value for data from these bar codes:

*0* *0*

*2*

*1* *1*

*3*

*2*

*3*

*4*

*5*

*4*

*6* *6*

*5*

*7*

*7*

9-69

Page 416

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

Maximum Retries (continued)

*8* *8*

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

9-70

*9*

*9*

39 Nugget