Page 397

Co de

39 Nugget Configuration Command Reference

9

Display Font Type Purpose:

Selects the type or size of font that is used on the terminal screen. You can set a regular size font (8x8), a font with double-height characters (8x16), or a font with double-width and double-height characters (16x16).

Syntax:

DTdata Acceptable values for data are: 0 1 2

Default: Scan:

8 pixels by 8 pixels (8x8) font 8 pixels wide by 16 pixels high (8x16) font 16 pixels wide by 16 pixels high (16x16) font

8x8 One of these bar codes: Set Display Font Type to 8x8

*$+DT0* *$+DT0*

Set Display Font Type to 8x16

*$+DT1*

*$+DT1*

Set Display Font Type to 16x16

*$+DT2* *$+DT2*

9-51

Page 398

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

39 Nugget

Display Row Spacing Purpose:

Sets the row spacing on the terminals. Row spacing lets you define the amount of additional space (scan lines) between the lines on the screen. The number of scan lines is two times the value you set for the row spacing. A scan line is a row of pixels. For example, a row spacing of 8 adds 16 blank scan lines between lines on the screen

Syntax:

DLdata Acceptable values for data are any number from 0 to 8.

Default: Scan:

0 One of these bar codes: Set Row Spacing to 0

*$+DL0*

*$+DL1*

*$+DL0*

*$+DL1*

Set Row Spacing to 2

Set Row Spacing to 3

*$+DL2*

*$+DL3*

*$+DL2*

*$+DL3*

Set Row Spacing to 4

Set Row Spacing to 5

*$+DL4*

*$+DL5*

*$+DL4*

*$+DL5*

Set Row Spacing to 6

Set Row Spacing to 7

*$+DL6* *$+DL6*

Set Row Spacing to 8

*$+DL8* *$+DL8*

9-52

Set Row Spacing to 1

*$+DL7*

*$+DL7*

Page 399

Co de

39 Nugget Configuration Command Reference

9

Display Video Mode Purpose:

Sets the Display Video mode that is used on the terminal screen. You can set the Display Video mode to original, normal, or inverse. Original displays black characters on a white background. Normal displays black characters on a white background. Inverse displays white characters on a black background.

Syntax:

DNdata Acceptable values for data are: 0 1 2

Default: Scan:

Original Normal Inverse

Original One of these bar codes: Original Display Video Mode

*$+DN0* *$+DN0*

Normal Display Video Mode

*$+DN1*

*$+DN1*

Inverse Display Video Mode

*$+DN2* *$+DN2*

9-53

Page 400

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

39 Nugget

Dynamic Host Configuration Protocol (DHCP) Purpose:

If your DCS 300 is operating as a DHCP client, its IP address will change each time it is turned on. By enabling DHCP on the T2425, the terminal can locate and use the DCS 300’s new IP address. The terminal’s IP address stays constant and must be assigned to the terminal by your system administrator. Before you can enable DHCP on the T2425, you need to configure the network parameters for the T2425, including the Controller IP Address. The IP address does not need to be the actual IP address for the DCS 300, since the T2425 will locate and reset the IP address after you enable DHCP. Note: DHCP is supported in the TRAKKER Antares firmware version 3.20 or later.

Syntax:

NIdata Acceptable values for data are: 0 1

Default: Scan:

Disable DHCP Enable DHCP

Disabled 1. One of these bar codes to disable or enable DHCP: Disable DHCP

*$+NI0* *$+NI0*

Enable DHCP

*$+NI1*

*$+NI1*

2. To save the changes in flash memory, scan this bar code: Save Configuration in Flash Memory

*.+1* *.+1*

9-54

Page 401

Co de

39 Nugget Configuration Command Reference

9

End of Message (EOM) Purpose:

Attaches an EOM to the end of a data block to indicate the end of data transmission to and from a terminal. When EOM is disabled, the terminal communicates in Character mode. When EOM is enabled, the terminal communicates in Frame mode. You must configure a value for EOM before you can set these other serial communications commands: • • • •

Configuration Commands Via Serial Port Handshake LRC Start of Message (SOM)

EOM cannot equal the same value that is set for SOM. You cannot set EOM to any of these values: • • • • • Syntax:

AFF (ACK) DLE NEG (NAK) Poll RES (EOT)

• • • •

REQ (ENQ) SEL XOFF XON

YZn.data where n is: 1 3 4

COM1 port COM3 port COM4 port

Acceptable values for data are one or two ASCII characters. Default: Scan:

\x03 (hexadecimal value for ETX) To disable EOM, scan one of these bar codes: Disable EOM for COM1

*$+YZ1.* *$+YZ1.*

Disable EOM for COM4

*$+YZ4.*

*$+YZ4.*

9-55

Page 402

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

39 Nugget

End of Message (continued) Or:

To set EOM to one or two ASCII characters for one serial port: 1. Scan this bar code: Enter Accumulate Mode / Set EOM

*+/$+YZ* *+/$+YZ*

2. Scan one of these bar codes to set the COM port: COM1

*1.* *1.*

COM4

*4.*

*4.*

3. Scan one or two bar codes for data from the “Full ASCII Bar Code Chart” in Appendix B. 4. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

5. Repeat Steps 1 through 4 to set the EOM for another serial port. Notes:

For COM1 only. To provide compatibility with earlier TRAKKER Antares firmware versions, you can also use this syntax: PFdata where data is one or two ASCII characters.

9-56

Page 403

Co de

39 Nugget Configuration Command Reference

9

Flash Memory Configuration Purpose:

Configures the use of the optional 2MB flash memory. If you have a terminal with the 4MB flash memory option, you can configure the extra 2MB of flash memory either as a drive D or as a storage space for double-byte fonts. You can store up to 32 files on drive D or store a 2MB double-byte font set. If you configure the flash memory as drive D, use this drive to store large lookup tables and data files. Note: You can only configure 2MB of the 4MB of flash memory as a drive or to store fonts. You cannot use the space for both. If you configure drive D, you cannot store a font in flash memory.

Syntax:

FFdata Acceptable values for data are: 0 Configure flash memory for double-byte fonts 32 Configure flash memory as drive D

Default: Scan:

Configure flash memory for double-byte fonts 1. Scan one of these bar codes: Configure Flash Memory for Double-Byte Fonts

*$+FF0* *$+FF0*

Configure Flash Memory as Drive D

*$+FF32* *$+FF32*

2. Scan this bar code to save the configuration change in flash memory: Save Configuration in Flash Memory

*.+1* *.+1*

3. Scan this bar code to boot the terminal and use the flash memory to store double-byte fonts or as drive D: Reset Firmware

*-.* *-.*

9-57

Page 404

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

39 Nugget

Flash Memory Configuration (continued) Note: When you boot or reset the terminal, any fonts or files in flash memory are erased. 4. If you configured the flash memory to store double-byte fonts, use the TRAKKER Antares Font Editor to download the double-byte font set to the terminal. See your local Intermec sales representative for information about the TRAKKER Antares Font Editor.

Flow Control Purpose:

Regulates the data transmission through the serial port. The terminal is a DTE (Data Terminal Equipment) device. There are several flow control options: •

CTS checking where Clear To Send (CTS) is a hardware signal flow control. The terminal sets and clears Request To Send (RTS) when it is ready to receive. The terminal checks CTS when it tries to transmit data.

•

XON/XOFF response causes the terminal to respond to XON/XOFF characters received while transmitting.

•

XON/XOFF control specifies that the terminal transmits XON/XOFF characters to control the incoming data flow.

•

XON/XOFF response and control specify that the terminal responds to and transmits XON/XOFF characters.

•

CTS/RTS for DTE-DTE allows for peer connections. Each terminal’s RTS output pin is connected to the CTS input pin of the other terminal. Each terminal sets RTS whenever it is ready to receive data and waits for CTS to be set before sending data.

Note: For TRAKKER Antares firmware version 4.X and earlier, you must disable the EOM command (use Character mode) to enable Flow Control with the XON/XOFF options. Syntax:

YLn.data where n is: 1 3 4

9-58

COM1 port COM3 port COM4 port

Page 405

Co de

39 Nugget Configuration Command Reference

9

Acceptable values for data are: 0 1 2 3 4 5 Default: Scan:

No flow control CTS checking XON/XOFF response XON/XOFF control XON/XOFF response and control CTS/RTS for DTE-DTE

No flow control To set the default flow control for each serial port, scan one of these bar codes: No Flow Control for COM1

No Flow Control for COM3

*$+YL1.0*

*$+YL3.0*

*$+YL1.0*

*$+YL3.0*

No Flow Control for COM4

*$+YL4.0* *$+YL4.0*

Or:

To set the flow control for one serial port: 1. Scan this bar code: Enter Accumulate Mode / Set Flow Control

*+/$+YL* *+/$+YL*

2. Scan one of these bar codes to set the COM port: COM1

*1.* *1.*

COM3

*3.*

*3.*

COM4

*4.* *4.*

9-59

Page 406

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

39 Nugget

Flow Control (continued) 3. Scan the flow control setting: No Flow Control

CTS Checking

*0*

*1*

XON/XOFF Response

XON/XOFF Control

*0*

*2*

*1*

*3*

*2*

*3*

XON/XOFF Response and Control

CTS/RTS for DTE-DTE

*4*

*5*

*4*

*5*

4. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

5. Repeat Steps 1 through 4 to set the flow control for another serial port. Notes:

For COM1 only. To provide compatibility with earlier TRAKKER Antares firmware versions, you can also use this syntax: ILdata where data is a numeric value from 0 to 5.

9-60