Page 367
Co de
39 Nugget Configuration Command Reference
9
Code 39 Purpose:
Enables or disables decoding of Code 39 symbology. Code 39 is discrete, variable length, and self-checking. The character set is uppercase A to Z, 0 to 9, dollar sign ($), period (.), slash (/), percent (%), space ( ), plus (+), and minus (-). There are three types of ASCII the terminal decodes: •
Code 39 non-full ASCII
•
Code 39 full ASCII
•
Code 39 mixed-full ASCII
Code 39 non-full ASCII Non-full ASCII uses a one-character encoding scheme. For example, you encode the data “SAMPLE” as follows:
*SAMPLE* *SAMPLE*
This label decodes as SAMPLE. Code 39 full ASCII Full ASCII uses a two-character encoding scheme to extend the character set to 128 characters. You use the dollar sign ($), slash (/), percent (%), or plus (+) followed by an uppercase letter to represent one of the characters in the extended set. You must encode lowercase letters as a plus sign (+) followed by their uppercase equivalents. For a list of ASCII characters and their Code 39 representations, see the “Full ASCII Table” in Appendix B. Use Code 39 full ASCII to enter ASCII control characters or lowercase characters as data. You should also enable Code 39 full ASCII to use ASCII command characters. For example, you encode the data “sample” in Code 39 full ASCII as follows:
*+S+A+M+P+L+E* *+S+A+M+P+L+E*
In Code 39 non-full ASCII, this label decodes as +S+A+M+P+L+E. In Code 39 full ASCII, this label decodes as sample. Code 39 mixed-full ASCII Use mixed-full ASCII when printers encode the same label two different ways. For example, if you have a bar code with the data $%a, some printers encode the data as follows:
*/D/E+A* */D/E+A*
In the Full ASCII Table in Appendix B, /D represents $ and /E represents %. If you configure the terminal for Code 39 full ASCII, the terminal decodes the data as $%a because there are three valid full ASCII character pairs to represent the data.
9-21
Page 368
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de
39 Nugget
Code 39 (continued) Other printers encode the data $%a as:
*$%+A* *$%+A*
The $ and % are valid Code 39 characters in the non-full ASCII character set. However, the terminal will not decode this label if it is configured for full ASCII, because the data is not represented by valid full ASCII character pairs. To decode the label correctly, you need to configure the terminal for mixed-full ASCII. When you configure the terminal for Code 39 mixed-full ASCII, the terminal will decode both of the labels above as $%a. Mixed-full ASCII interprets any valid full ASCII character pairs that appear in the label, but does not require that all data be encoded with a valid full ASCII character pair. If you are uncertain how your labels are encoded, configure the terminal for mixed-full ASCII, which decodes all valid Code 39 labels. If you configure the terminal for Code 39 full ASCII, you should check for Code 39 mixed-full ASCII. Mixed-full ASCII does not apply when you configure the terminal for non-full ASCII. Note: The interpretive text shown under bar code labels does not always accurately reflect the data that is encoded in the label. The interpretive text represents how the label should be decoded. Use this table to help configure your terminal.
Syntax:
Code 39 Option
Bar Code Label
Decodes
Non-full ASCII
$%+A /D/E+A
$%+A /D/E+A
Full ASCII
$%+A /D/E+A
No decode $%a
Mixed-full ASCII
$%+A /D/E+A
$%a $%a
CBdata Acceptable values for data must be three digits, corresponding to: First digit:
9-22
0 1 2 3 4
Disabled Enabled with no check digit Enabled with check digit HIBC (Health Industry Bar Code) With AIAG check digit
Page 369
Co de
39 Nugget Configuration Command Reference
Second digit:
0 1
Discard check digit Transmit check digit
Third digit:
0 1 2
Code 39 non-full ASCII Code 39 full ASCII Code 39 mixed-full ASCII
9
Note: Selecting HIBC Code 39 automatically sets the configuration to non-full ASCII with the check digit transmitted. Default: Scan:
Enable Code 39 Full ASCII with no check digit (111) To disable Code 39: Disable Code 39
*$+CB0* *$+CB0*
Or:
To enable Code 39: 1. Scan this bar code: Enter Accumulate Mode / Enable Code 39
*+/$+CB* *+/$+CB*
2. Scan one of these bar codes to set the first digit: Without a Check Digit
*1*
With a Check Digit
*2*
*1*
*2*
HIBC Code 39
With AIAG Check Digit
*3* *3*
*4*
*4*
3. Scan one of these bar codes to set the second digit: Discard Check Digit
Transmit Check Digit
*0*
*1*
*0*
*1*
9-23
Page 370
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de
39 Nugget
Code 39 (continued) 4. Scan one of these bar codes to set the third digit: Code 39 Non-Full ASCII
Code 39 Full ASCII
*0*
*1*
*0*
Code 39 Mixed-Full ASCII
*2* *2*
5. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
9-24
*1*
Page 371
Co de
39 Nugget Configuration Command Reference
9
Code 49 Purpose:
Enables or disables decoding of Code 49 symbology. Code 49 is a multirow symbology for high data density. The last character in each row is used for row checking and the last two characters of the symbol are used for overall checking. Function codes designate where to place the predefined data string in a Code 49 label. Whenever a terminal encounters a function code, it replaces the function code with the defined string before transmitting the data to the DCS 300. A single Code 49 symbol may contain several different variable length data fields. Function Code 1 (F1) identifies a data system. Function Code 2 (F2) indicates the end of a data field.
Syntax:
CJdata CKdata CLdata CMdata
Code 49 Function Code 1 Function Code 2 Function Code 3
Acceptable values for data are: Code 49 (CJ):
Default: Scan:
0 1
Function Code 1 (CK):
Any two ASCII characters.
Function Code 2 (CL):
Any four ASCII characters
Function Code 3 (CM):
Any two ASCII characters
Disabled One of these bar codes: Disable Code 49
Enable Code 49
*$+CJ0*
*$+CJ1*
*$+CJ0*
Scan:
Disabled Enabled
*$+CJ1*
To disable any of the function codes, scan one of these bar codes: Disable Function Code 1
Disable Function Code 2
*$+CK*
*$+CL*
*$+CK*
*$+CL*
Disable Function Code 3
*$+CM* *$+CM*
9-25
Page 372
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de
39 Nugget
Code 49 (continued) Or:
To set one of the function codes to a character string: 1. Scan one of these bar codes: Enter Accumulate Mode / Set Function Code 1
*+/$+CK* *+/$+CK*
Enter Accumulate Mode / Set Function Code 2
*+/$+CL* *+/$+CL*
Enter Accumulate Mode / Set Function Code 3
*+/$+CM* *+/$+CM*
2. Scan any character from the “Full ASCII Bar Code Chart” in Appendix B. You can define two characters each for Function Codes 1 and 3, and four characters for Function Code 2. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
9-26
Page 373
Co de
39 Nugget Configuration Command Reference
9
Code 93 Purpose:
Enables or disables decoding of Code 93 symbology. Code 93 is a variable length, continuous symbology that uses four element widths.
Syntax:
CFdata Acceptable values for data are: 0 1
Default: Scan:
Disabled Enabled
Disabled One of these bar codes: Disable Code 93
Enable Code 93
*$+CF0*
*$+CF1*
*$+CF0*
*$+CF1*
9-27
Page 374
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de
39 Nugget
Code 128 Purpose:
Enables or disables decoding of Code 128 symbology. Code 128 is a very high density alphanumeric symbology that supports the extended ASCII character set. It is a variable length, continuous code that uses multiple element widths.
Syntax:
CHdata Acceptable values for data are: 0 1 2 8
Disabled Standard Code 128 UCC/EAN Code 128 ISBT Code 128
Note: For help configuring ISBT Code 128, see the next section. Default: Scan:
Standard One of these bar codes: Disable Code 128
*$+CH0*
*$+CH1*
*$+CH0*
*$+CH1*
Enable UCC/EAN Code 128
Enable ISBT Code 128
*$+CH2*
*$+CH8*
*$+CH2*
Notes:
Enable Standard Code 128
*$+CH8*
If you configure Standard Code 128, the terminal will not decode Function Code 1 characters in the first position of a bar code label. Any subsequent Function Code 1 characters are translated to the ASCII GS character as a separator for variable length fields. If you configure UCC/EAN Code 128, the terminal will decode a bar code label as Standard Code 128 unless one of the first two characters are a start character and a Function Code 1. In this case, the bar code label is processed as described next: 1. The Function Code 1 character is not transmitted. 2. The three symbology ID characters, ]C1, are transmitted. 3. The remaining Code 128 characters are decoded as Standard Code 128.
9-28
Page 375
Co de
39 Nugget Configuration Command Reference
9
ISBT Code 128 Purpose:
Enables and configures decoding of ISBT Code 128 symbology. ISBT Code 128 is the global bar code labeling standard for the blood banking industry. It is used to support the world-wide distribution, tracking, and handling of blood bags and blood components. For more information on ISBT Code 128, see the ISBT 128 Bar Code Symbology and Application Specification for Labeling of Whole Blood and Blood Components prepared by the International Council for Commonality in Blood Banking Automation.
Syntax:
CH8data where data can be up to 10 digits selected from this list: Digits
Values
Description
1
0
Symbology identifier (ID) disabled.
1
Symbology ID enabled. Output of ]C0 indicates a single ISBT Code 128 bar code was read. Output of ]C4 indicates that a pair of ISBT Code 128 bar codes was read.
0
Concatenation disabled.
1
Restricted concatenation enabled.
See List*
Left Data ID to be matched for restricted concatenation.
2
3-4
* List of valid combinations are: =% => &> =* &* =< =) &) =& &< &( &! &; =n &n 5-6
See List*
Blood Groups and Rh Expiration Date Expiration Date and Time Collection Date Collection Date and Time ISBT Product Code Manufacturer ID Manufacturer Lot Number Concatenation Bar Code National Product Code National Special Test Unit Exclusion Status National Special Donor Donation ID Number where n is a value from 0 to 9 or uppercase A through Z National Use Bar Code where n is a value from lowercase a through z
Right Data ID to be matched for restricted concatenation. See the list of valid combinations for digits 3 and 4.
9-29
Page 376
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de
39 Nugget
ISBT Code 128 (continued) Digits
Values
Description
7-9
000-999
Bar code concatenation control parameters. If digit 10 is “d,” digits 7 and 8 refer to the nominal distance in millimeters between the stop characters of two bar code labels that can be concatenated, and digit 9 is the bar code label positioning tolerance. If the distance between the two bar code labels is outside this limit (assuming standard ISBT bar code print size), the bar code labels will not be concatenated. If digit 10 is “t,” digits 7, 8, and 9 are the decode time limit in milliseconds. If both bar code labels are not decoded in the same beam sweep within this time, the bar code labels are not concatenated. This time parameter is only accurate to a 25millisecond resolution.
10 d or t
Identifies the concatenation control as either the distance “d” between bar code labels or the time “t” in which concatenated bar code labels must be decoded. See description for Digits 7-9.
Note: The Left Data ID and Right Data ID are used only with the restricted concatenation option. For example, the terminal will concatenate only those bar code labels with data identifiers that match the configured data identifiers. The spacing between bar codes that can be concatenated must be between two and five character widths. Default:
Scan:
Digit 1: Digit 2:
Symbology ID disabled Concatenation disabled
This bar code to enable ISBT Code 128 Enable ISBT Code 128
*$+CH8* *$+CH8*
Note: To scan the following bar codes, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” earlier in this chapter. Or:
To configure ISBT Code 128: 1. Scan this bar code: Enter Accumulate Mode/Enable ISBT Code 128
*+/$+CH8* *+/$+CH8*
9-30