The text of a manual · part 44 of 64
Trakker Antares 24XX Terminal User's Manual Addendum, with the Trakker Antares 2420 and 2425 Hand-Held Terminal User's Manual: Chapter 9 - Configuration Command Reference, pages 357 to 366
Pages 357 to 366 of 558, from Trakker Antares 24XX Terminal User's Manual Addendum, with the Trakker Antares 2420 and 2425 Hand-Held Terminal User's Manual
The original document is the PDF (4.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2420 and Intermec 2425
Page 357
Co de
39 Nugget Configuration Command Reference
9
Automatic Shutoff Purpose:
Defines the maximum length of time the terminal remains on when there is no activity. When you do not use the terminal for the length of time set with this command, the terminal automatically turns off as if you had pressed to turn it off.
L
L
When you press to turn on the terminal, the terminal either resumes exactly where it was when you turned it off or the terminal boots and restarts your application. Resume is controlled through the Resume Execution command. For help, see “Resume Execution” later in this chapter. Power Management Tip: You should use the Automatic Shutoff feature to preserve the main battery pack’s power. Syntax:
EZdata Acceptable values for data are: 0 02-75
Default: Scan:
Disabled (always on) Shutoff time in minutes
Disabled To disable automatic shutoff, scan this bar code: Disable Automatic Shutoff
*$+EZ0* *$+EZ0*
Or:
To set a timeout: 1. Scan this bar code: Enter Accumulate Mode / Set Automatic Shutoff
*+/$+EZ* *+/$+EZ*
9-11
Page 358
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de
Automatic Shutoff (continued) 2. Scan a numeric value for data from these bar codes:
*0* *0*
*2*
*1*
*3*
*2*
*3*
*4*
*5*
*4*
*6* *6*
*8* *8*
3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
9-12
*1*
*5*
*7*
*7*
*9*
*9*
39 Nugget
Page 359
Co de
39 Nugget Configuration Command Reference
9
Baud Rate Purpose:
Sets the baud rate for the serial port on the terminal. The baud rate must match the baud rate of the device (i.e., the host computer) that the terminal is communicating with through the serial port.
Syntax:
YAn.data where n is: 1 3 4
COM1 port COM3 port COM4 port
Acceptable values for data are: 3 4 5 6 7 8
1200 baud 2400 baud 4800 baud 9600 baud 19200 baud 38400 baud
Note: For COM3 ports, the maximum baud rate is actually 33600 baud. Default: Scan:
19200 To set the default baud rate for each serial port, scan these bar codes: Default Baud Rate for COM1
Default Baud Rate for COM3
*$+YA1.7*
*$+YA3.7*
*$+YA1.7*
*$+YA3.7*
Default Baud Rate for COM4
*$+YA4.7* *$+YA4.7*
Or:
To set the baud rate for one serial port: 1. Scan this bar code: Enter Accumulate Mode/Set Baud Rate
*+/$+YA* *+/$+YA*
9-13
Page 360
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de
39 Nugget
Baud Rate (continued) 2. Scan the serial port from these bar codes: COM1
*1.*
*1.*
COM3
*3.*
*3.*
COM4
*4.*
*4.*
3. Scan the baud rate from these bar codes: 1200 Baud
*3*
2400 Baud
*4*
*3*
*4*
4800 Baud
9600 Baud
*5*
*6*
*5*
*6*
19200 Baud
38400 Baud
*7* *7*
*8*
*8*
4. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
5. Repeat Steps 1 through 4 to se the baud rate for another serial port. Notes:
For COM1 only. To provide compatibility with earlier TRAKKER Antares firmware versions, you can also use this syntax: IAdata where data is a value from 3 to 8.
9-14
Page 361
Co de
39 Nugget Configuration Command Reference
9
Beep Volume Purpose:
Adjusts the volume of the terminal’s audio signals. For a list of all the beep sounds and audio signals, see “Understanding the Terminal’s Audio Signals” in Chapter 2. Set the beep and keyclick volume according to operator preference and work environment. Note: If the Beep Volume command is set to off, you will not hear any audio signals including the keyclick.
Syntax:
BVdata Acceptable values for data are: 0 1 2 3 4 8 9
Default: Scan:
Off Quiet Normal Loud Very loud Lower volume Raise volume
Very loud One of these bar codes: Beep Volume Off
*$+BV0*
Beep Volume Quiet
*$+BV1*
*$+BV0*
*$+BV1*
Beep Volume Normal
Beep Volume Loud
*$+BV2* *$+BV2*
*$+BV3*
*$+BV3*
Beep Volume Very Loud
*$+BV4* *$+BV4*
Or:
Scan one of these bar codes repeatedly to achieve the desired volume: Raise Beep Volume
*$+BV9* *$+BV9*
Lower Beep Volume
*$+BV8*
*$+BV8*
9-15
Page 362
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de
39 Nugget
Codabar Purpose:
Enables or disables decoding of Codabar symbology. Codabar is a self-checking, discrete symbology. The American Blood Commission (ABC) Codabar requires that you retain and transmit the start/stop code digits when processing a Codabar symbol. As a result, configuration CD10 is an illegal configuration.
Syntax:
CDdata Acceptable values for data must be two digits, corresponding to:
Default: Scan:
Digit
Value
Description
First
0 1 2 3
Disabled ABC Standard Concatenated
Second
0 1 2
Discard Start/Stop Transmit ABCD Start/Stop Transmit DC1-DC4 Start/Stop
Disabled One of these bar codes: Disabled, Discard Start/Stop
ABC, Transmit ABCD Start/Stop
*$+CD00*
*$+CD11*
ABC, Transmit DC1-DC4 Start/Stop
Standard, Discard Start/Stop
*$+CD00*
*$+CD12*
*$+CD20*
*$+CD12*
*$+CD20*
Standard, Transmit ABCD Start/Stop
Standard, Transmit DC1-DC4 Start/Stop
*$+CD21*
*$+CD22*
*$+CD21*
*$+CD22*
Concatenated, Discard Start/Stop
Concatenated, Transmit ABCD Start/Stop
*$+CD30* *$+CD30*
Concatenated, Transmit DC1-DC4 Start/Stop
*$+CD32*
*$+CD32*
9-16
*$+CD11*
*$+CD31*
*$+CD31*
Page 363
Co de
39 Nugget Configuration Command Reference
9
Code 11 Purpose:
Enables or disables decoding of Code 11 symbology. Code 11 is a very high density, discrete numeric bar code. It is most extensively used in labeling telecommunications components and equipment.
Syntax:
CGdata Acceptable values for data are: 0 1 2
Default: Scan:
Disabled Code 11 enabled with one check digit Code 11 enabled with two check digits
Disabled One of these bar codes: Disable Code 11
*$+CG0* *$+CG0*
Code 11 Enabled With One Check Digit
Code 11 Enabled With Two Check Digits
*$+CG1*
*$+CG2*
*$+CG1*
*$+CG2*
9-17
Page 364
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de
39 Nugget
Code 16K Purpose:
Enables or disables decoding of Code 16K symbology. Code 16K is a two-dimensional (stacked rows), high density bar code. It is based on Code 128 and is used widely to label unit-dose packaging for the healthcare industry.
Syntax:
CPdata Acceptable values for data are: 0 1 2
Disabled Standard Code 16K enabled Code 16K enabled with Function Code 1
When you enable Code 16K with Function Code 1, the terminal decodes the bar code label and checks for a Function Code 1 in the first data character position. If a Function Code 1 is the first character, the terminal substitutes this Code 16K symbology identifier string for the Function Code 1 character. ]K1
Default: Scan:
Disabled One of these bar codes: Disable Code 16K
Standard Code 16K Enabled
*$+CP0*
*$+CP1*
*$+CP0*
Code 16K Enabled With Function Code 1
*$+CP2* *$+CP2*
9-18
*$+CP1*
Page 365
Co de
39 Nugget Configuration Command Reference
9
Code 2 of 5 Purpose:
Enables or disables decoding of Code 2 of 5 symbology. Code 2 of 5 uses the bars to encode information and the spaces to separate the individual bars. This code is discrete and self-checking. You can only enable Code 2 of 5 if the Interleaved 2 of 5 (I 2 of 5) code is disabled. If you enable I 2 of 5, Code 2 of 5 is automatically disabled.
Syntax:
CCdata where data consists of three digits as follows:
Default: Scan:
First digit:
0 1
Code 2 of 5, 3 Bar Start/Stop Code 2 of 5, 2 Bar Start/Stop
Second and third digits:
00 01-32
Disable Code 2 of 5 Label Length
Disabled To disable Code 2 of 5, scan this bar code: Disable Code 2 of 5
*$+CC000* *$+CC000*
Or:
To enable Code 2 of 5: 1. Scan one of these bar codes: Code 2 of 5, 3 Bar Start/Stop
*+/$+CC0* *+/$+CC0*
Code 2 of 5, 2 Bar Start/Stop
*+/$+CC1* *+/$+CC1*
9-19
Page 366
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de
39 Nugget
Code 2 of 5 (continued) 2. Scan a two-digit numeric value to set the label length (01-32) from these bar codes.
*0* *0*
*2*
*1*
*3*
*2*
*3*
*4*
*5*
*4*
*6* *6*
*8* *8*
3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
9-20
*1*
*5*
*7*
*7*
*9*
*9*