Trakker Antares 24XX Terminal User's Manual Addendum, with the Trakker Antares 2420 and 2425 Hand-Held Terminal User's Manual: Chapter 9 - Configuration Command Reference, pages 347 to 356

Pages 347 to 356 of 558, from Trakker Antares 24XX Terminal User's Manual Addendum, with the Trakker Antares 2420 and 2425 Hand-Held Terminal User's Manual

The original document is the PDF (4.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 2420 and Intermec 2425

Page 347

9 Configuration Command Reference

Page 348

9-2

Page 349

Co de

39 Nugget Configuration Command Reference

9

This chapter is an alphabetical list of all the configuration commands supported on the terminal.

Using Configuration Commands A configuration command changes the way the terminal operates. For example, you can change the Beep Volume command and make the terminal beep very loudly in a noisy environment. You can execute configuration commands by • scanning a command from a Code 39 or Code 93 bar code label. These labels are provided in this chapter. For more help, see Chapter 3, “Configuring the Terminal.”

• choosing a command from the TRAKKER Antares 2400 Menu System. For help using the menu system, see Chapter 3, “Configuring the Terminal.”

• sending a command from a device on the serial or RF network. For help, see “Using Serial Communications on the Terminals” and “Using RF Communications on the T2425s” in Chapter 4.

You can find the following information about each configuration command in this chapter: •

Command description and purpose

•

Command syntax and options

•

Default setting

•

Bar code labels you can scan to set or change each command

The configuration commands are listed alphabetically by command name. For a list of bar code symbology, operations, serial network communications, or RF network communications commands, use the next table, “Configuration Commands Listed by Category.” If you want to look up a command by its syntax, see the “Configuration Commands by Syntax” list in Appendix A. Note: The Code 39 bar code labels in this chapter show an asterisk (*) at the beginning and end of the human-readable interpretation to represent the start and stop codes. If you are creating your own Code 39 bar code labels, your bar code printing utility may automatically supply the asterisks as the start/stop code.

9-3

Page 350

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

39 Nugget

Configuration Commands Listed by Category This chapter lists the configuration commands in alphabetical order. Use this next list to find the configuration commands you may need to set for bar code symbologies, operations, serial network communications, or RF network communications. Bar Code Symbologies

Operations

Codabar, 9-16

Append Time, 9-10

Code 11, 9-17

Automatic Shutoff, 9-11

Code 16K, 9-18

Beep Volume, 9-15

Code 2 of 5, 9-19

Command Processing, 9-34

Code 39, 9-21

Decode Security, 9-46

Code 49, 9-25

Display Backlight Timeout, 9-49

Code 93, 9-27

Display Contrast, 9-50

Code 128, 9-28

Display Font Type, 9-51

Interleaved 2 of 5, 9-64

Display Row Spacing, 9-52

MSI, 9-75

Display Video Mode, 9-53

Plessey, 9-82

Flash Memory Configuration, 9-57

UPC/EAN, 9-118

Keypad Caps Lock, 9-66 Keypad Clicker, 9-66 Keypad Type, 9-67 Postamble, 9-84 Preamble, 9-85 RAM Drive Size, 9-87 Resume Execution, 9-89 Scan Ahead, 9-95 Scanner Mode, 9-96 Scanner Redundancy, 9-97 Scanner Selection, 9-98 Scanner Timeout, 9-100 Scanner Trigger, 9-101 Suspend/Resume Control, 9-108 Time and Date, 9-114 Time in Seconds, 9-115

9-4

Page 351

Co de

39 Nugget Configuration Command Reference

9

Configuration Commands Listed by Category (continued) RF Network Communications

Serial Network Communications

Acknowledgement Delay Lower Limit, 9-7

Baud Rate, 9-13

Acknowledgement Delay Upper Limit, 9-9

Configuration Commands Via Serial Port, 9-38

Controller Connect Check Receive Timer, 9-40

Data Bits, 9-45

Controller Connect Check Send Timer, 9-41

End of Message (EOM), 9-55

Controller IP Address, 9-43

Flow Control, 9-58

Default Router, 9-47

Handshake, 9-61

Dynamic Host Configuration Protocol (DHCP), 9-54

LRC (Longitudinal Redundancy Check), 9-68

Host IP Address, 9-62

Modem Dial Sequence, 9-71

Maximum Retries, 9-69

Modem Initialization Sequence, 9-73

Network Activate, 9-76

Parity, 9-80

Network Loopback, 9-77

Poll (Polling), 9-83

Network Port, 9-78

Serial Port Protocol, 9-102

RF Domain, 9-90

Start of Message (SOM), 9-104

RF Inactivity Timeout, 9-91

Stop Bits, 9-106

RF Roaming Flag, 9-92

Timeout Delay, 9-116

RF Security Identification (ID), 9-93 RF Transmit Mode, 9-94 RF Wakeup On Broadcast, 9-95 Subnet Mask, 9-107 TCP/IP Maximum Retries, 9-109 TCP/IP Maximum Transmit Timeout, 9-110 Terminal IP Address, 9-112

9-5

Page 352

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

39 Nugget

Entering Variable Data in a Configuration Command You can enter variable data for many of the configuration commands. For example, you can set a preamble that is up to 25 ASCII characters long. You need to follow these general instructions to enter variable data. To enter variable data in a configuration command 1. Scan a bar code label with this syntax: +/$+command where: +/ is the syntax for the Enter Accumulate Mode command.

$+ is the syntax for the Change Configuration command.

command is the syntax for the command you want to change.

For example, the command syntax for a preamble is ADdata. To change or set a preamble, scan this bar code: Enter Accumulate Mode / Change Configuration / Set Preamble

*+/$+AD* *+/$+AD*

2. Scan a bar code label from the “Full ASCII Bar Code Chart” in Appendix B. To set the preamble to the character T, scan this label: T

*T* *T*

Note: To use the bar code labels in Appendix B, you may need to configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” later in this chapter. 3. Scan the Exit Accumulate Mode bar code label to update the terminal’s configuration: Exit Accumulate Mode

*-/* *-/*

9-6

Page 353

Co de

39 Nugget Configuration Command Reference

9

Acknowledgement Delay Lower Limit Purpose:

When the T2425 sends a message to the DCS 300, the terminal waits to receive a response acknowledging the message. If no response is received within the Acknowledgement Delay Lower Limit time, the terminal sends the message again at the time interval set for the lower limit. The terminal will continue to send the data at increasingly longer intervals until it reaches the Acknowledgement Delay Upper Limit time. The terminal continues sending the message at the time interval set for the upper limit until a response is received or a timeout error occurs.

Syntax:

NVdata Acceptable values for data are any number from 200 to 2000 ms.

Default: Scan:

300 ms To set the default acknowledgement delay lower limit, scan this bar code: Default Acknowledgement Delay Lower Limit

*$+NV300* *$+NV300*

Or:

To set the acknowledgement delay lower limit: 1. Scan this bar code: Enter Accumulate Mode / Set Acknowledgement Delay Lower Limit

*+/$+NV* *+/$+NV*

2. Scan a numeric value for data from these bar codes:

*0* *0*

*2*

*1* *1*

*3*

*2*

*3*

*4*

*5*

*4*

*6* *6*

*5*

*7*

*7*

9-7

Page 354

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

Acknowledgement Delay Lower Limit (continued)

*8* *8*

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

9-8

*9*

*9*

39 Nugget

Page 355

Co de

39 Nugget Configuration Command Reference

9

Acknowledgement Delay Upper Limit Purpose:

When the T2425 sends a message to the DCS 300, the terminal waits to receive a response acknowledging the message. If no response is received within the Acknowledgement Delay Lower Limit time, the terminal sends the message again at the time interval set for the lower limit. The terminal will continue to send the data at increasingly longer intervals until it reaches the Acknowledgement Delay Upper Limit time. The terminal continues sending the message at the time interval set for the upper limit until a response is received or a timeout error occurs.

Syntax:

NUdata Acceptable values for data are any number from 2000 to 60000 ms.

Default: Scan:

5000 ms To set the default acknowledgement delay upper limit, scan this bar code: Default Acknowledgement Delay Upper Limit

*$+NU5000* *$+NU5000*

Or:

To set the acknowledgement delay upper limit: 1. Scan this bar code: Enter Accumulate Mode / Set Acknowledgement Delay Upper Limit

*+/$+NU* *+/$+NU*

2. Scan a numeric value for data from these bar codes:

*0* *0*

*2*

*1* *1*

*3*

*2*

*3*

*4*

*5*

*4*

*6* *6*

*5*

*7*

*7*

9-9

Page 356

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

39 Nugget

Acknowledgement Delay Upper Limit (continued)

*8* *8*

*9*

*9*

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

Append Time Purpose:

Appends the time to bar code labels that are scanned on the terminal. You can also use the Time in Seconds command to append the time in hours and minutes only, or hours, minutes, and seconds. The time is appended to the data in the form HH:MM:SS. For help, see “Time in Seconds” later in this chapter.

Syntax:

DEdata Acceptable values for data are: 0 1

Default: Scan:

Disabled Enabled

Disabled One of these bar codes: Disable Append Time

Enable Append Time

*$+DE0*

*$+DE1*

*$+DE0*

9-10

*$+DE1*