The text of a manual · part 46 of 64
Trakker Antares 24XX Terminal User's Manual Addendum, with the Trakker Antares 2420 and 2425 Hand-Held Terminal User's Manual: Chapter 9 - Configuration Command Reference, pages 377 to 386
Pages 377 to 386 of 558, from Trakker Antares 24XX Terminal User's Manual Addendum, with the Trakker Antares 2420 and 2425 Hand-Held Terminal User's Manual
The original document is the PDF (4.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2420 and Intermec 2425
Page 377
Co de
39 Nugget Configuration Command Reference
9
2. Scan one of these bar codes to disable or enable symbology ID: Symbology ID Disabled
Symbology ID Enabled
*0*
*1*
*0*
*1*
Note: Steps 3 through 9 are optional. 3. Scan one of these bar codes to disable or enable concatenation: Disable Concatenation
Enable Concatenation
*0*
*1*
*0*
*1*
If you disabled concatenation, go to Step 10. 4. Scan one of these bar codes to set the Left Data ID: Blood Groups and Rh
*%H/E*
Expiration Date
*%H%I*
*=%*
*=>*
Expiration Date and Time
Collection Date
*/F%I*
*%H/J*
*&>*
*=**
Collection Date and Time
ISBT Product Code
*/F/J*
*%H%G*
*&**
*=<*
Manufacturer ID
Manufacturer Lot Number
*%H/I*
*/F/I*
Concatenation Bar Code
National Product Code
*%H/F*
*/F%G*
National Special Test
Unit Exclusion Status
*=)*
*=&*
*/F/H* *&(*
*&)*
*&<*
*/F/A*
*&!*
9-31
Page 378
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de
39 Nugget
ISBT Code 128 (continued) National Special Donor
*/F%F* *&;*
Donation ID Number (See Note)
*%H*
*=*
National Use Bar Code (See Note)
*/F* *&*
Note: If you scan the Donation ID Number or National Use Bar Code, go to Step 5. 5. For the Donation ID Number or the National Use Bar Code, scan an alphanumeric bar code from Appendix B. •
For the Donation ID Number, scan a value from 0 through 9 or uppercase A through Z.
•
For the National Use Bar Code, scan a value from lowercase a through z.
6. Scan one of these bar codes to set the Right Data ID: Blood Groups and Rh
*%H/E*
*%H%I*
*=%*
*=>*
Expiration Date and Time
Collection Date
*/F%I*
*%H/J*
*&>*
*=**
Collection Date and Time
ISBT Product Code
*/F/J*
*%H%G*
*&**
*=<*
Manufacturer ID
Manufacturer Lot Number
*%H/I*
*/F/I*
Concatenation Bar Code
National Product Code
*%H/F*
*/F%G*
*=)*
*=&*
9-32
Expiration Date
*&)*
*&<*
Page 379
Co de
39 Nugget Configuration Command Reference
National Special Test
*/F/H*
Unit Exclusion Status
*/F/A*
*&(*
*&!*
National Special Donor
Donation ID Number (See Note)
*/F%F* *&;*
9
*%H*
*=*
National Use Bar Code (See Note)
*/F* *&*
Note: If you scan the Donation ID Number or National Use Bar Code, go to Step 7. 7. For the Donation ID Number or the National Use Bar Code, scan an alphanumeric bar code from Appendix B. •
For the Donation ID Number, scan a value from 0 through 9 or uppercase A through Z.
•
For the National Use Bar Code, scan a value from lowercase a through z.
8. Skip to Step 10 if you want to keep the default concatenation control parameters. •
The default concatenation distance is 16 mm ± 0 mm.
•
The default concatenation decode time limit is 160 ms.
To set the concatenation decode time limit, scan these bar codes to set the time from 001 to 999 ms. To set the concatenation distance, scan these bar codes to set the distance from 00 to 99 mm and the tolerance from ± 1 to 9 mm.
*0* *0*
*2*
*1* *1*
*3*
*2*
*3*
*4*
*5*
*4*
*6* *6*
*8* *8*
*5*
*7*
*7*
*9*
*9*
9-33
Page 380
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de
39 Nugget
ISBT Code 128 (continued) 9. Scan one of these bar codes to set distance or time: Distance
Time
*+D*
*+T*
*d*
*t*
10. Scan this bar code to exit accumulate mode: Exit Accumulate Mode
*-/* *-/*
Command Processing Purpose:
Command processing lets you disable or enable reader commands. For example, you can disable the Backlight command. There are two ways to enable or disable reader commands: •
Use the Command Processing configuration command described here.
•
Use the Reader Command Menu option in the Configuration Menu of the TRAKKER Antares 2400 Menu System.
You may want to disable reader commands to prevent a user from accidentally entering a command, or to use data that would otherwise be treated as a command. Any Code 39 or Code 93 bar code label that contains the 2-character to 4-character commands for Command Processing is treated as a reader command unless the command is disabled. If you want to disable or enable several commands, it is easier to use the menu system. For help, see Chapter 3, “Configuring the Terminal.” For a description of each reader command that you can enable or disable with Command Processing, see Chapter 8, “Reader Command Reference.” Syntax:
DCdata Acceptable values for data are: 0 1 2 3 command0 command1
9-34
Disable all reader commands Enable all reader commands Disable override Enable override Disable reader command Enable reader command
Page 381
Co de
39 Nugget Configuration Command Reference
9
The override option is a temporary setting that lets you enable all the reader commands for as long as you need them. When you want to return to the previous configuration, you disable the override. Note: The Enable Override option is the only bar code label you can scan to enable reader commands if you have disabled all reader commands (DC0). You can also enable reader commands in the TRAKKER Antares 2400 Menu System. Default: Scan:
All reader commands enabled To enable all the reader commands or override the current settings, scan one of these bar codes: Disable All Reader Commands
Enable All Reader Commands
*$+DC0*
*$+DC1*
Disable Override
Enable Override
*$+DC2*
*$+DC3*
*$+DC0*
*$+DC2*
Or:
*$+DC1*
*$+DC3*
To disable or enable specific reader commands, perform these steps: 1. Scan this bar code: Enter Accumulate Mode / Command Processing
*+/$+DC* *+/$+DC*
2. Scan the bar code to disable or enable one reader command. Note: If there are two bar codes for a reader command, you must scan them in order, left to right. Accumulate mode commands are separated into two bar codes so that the command can be accumulated rather than executed as a command. Abort Program
Backlight
*/$*
*%.*
Backspace
(continued)
*-*
*+*
*/$*
*-*
*%.*
*+*
9-35
Page 382
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de
39 Nugget
Command Processing (continued) Change Configuration
*$+* *$+* Clear
(continued)
*-*
*-*
Default/Save Configuration
Delete File
*.+*
*..--*
Enter Accumulate Mode
(continued)
*+*
*/*
Exit Accumulate Mode
(continued)
*-*
*/*
Receive File
Rename File
*.%*
*...-*
Reset Firmware
Run Program
*-.*
*//*
Scanner Trigger Off
Scanner Trigger On
*/%*
*/.*
Set Time and Date
Test and Service Mode
*/+*
*..-.*
*-*
*.+*
*+*
*-*
*.%*
*-.*
*/%*
*/+*
9-36
*-*
*..--*
*/*
*/*
*...-*
*//*
*/.*
*..-.*
Page 383
Co de
39 Nugget Configuration Command Reference
9
Transmit File
*%%* *%%*
3. Scan one of these bar codes: Disable the Command
Enable the Command
*0*
*1*
*0*
*1*
4. Repeat Steps 2 and 3 to disable or enable another reader command. Note: You can accumulate up to 250 characters in the buffer. If the data accumulated exceeds 250 characters, you will hear an error beep and the terminal will reject the last bar code read. 5. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
Or:
To disable or enable the ability to scan multiple-read labels, scan one of these bar codes: Disable Multiple-Read Labels
*$+DC 0* *$+DC 0*
Enable Multiple-Read Labels
*$+DC 1*
*$+DC 1*
9-37
Page 384
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de
39 Nugget
Configuration Commands Via Serial Port Purpose:
Lets you control the data the terminal receives through the serial port. You can set this command to execute reader and configuration commands received through the serial port, or treat all data as data without checking for special command syntax. There are three options: Disabled All data received through the serial port is treated as data. The terminal will not execute reader or configuration commands sent or encoded in the data. Enabled with TMF If the data is sent with the TMF (Terminal Message Format) header, the terminal will check for and execute reader or configuration commands received through the serial port. With TMF, you can execute reader and configuration commands, or send and receive data about the current terminal configuration. Enabled without TMF The terminal will check for and execute all reader and configuration commands (i.e., Receive File reader command or Beep Volume change configuration command). Note: Before you can enable Configuration Commands Via Serial Port with or without TMF, you must enable the EOM command.
Syntax:
YTn.data where n is: 1 3 4
COM1 port COM3 port COM4 port
Acceptable values for data are: 0 1 2
Disabled Enabled with TMF Enabled without TMF
Default:
Enabled without TMF
Scan:
One of these bar codes: COM1 Commands Via Serial Port Disabled
*$+YT1.0* *$+YT1.0*
COM1 Commands Via Serial Port Enabled With TMF
*$+YT1.1* *$+YT1.1*
9-38
Page 385
Co de
39 Nugget Configuration Command Reference
9
COM1 Commands Via Serial Port Enabled Without TMF
*$+YT1.2* *$+YT1.2*
COM3 Commands Via Serial Port Disabled
*$+YT3.0* *$+YT3.0*
COM3 Commands Via Serial Port Enabled With TMF
*$+YT3.1* *$+YT3.1*
COM3 Commands Via Serial Port Enabled Without TMF
*$+YT3.2* *$+YT3.2*
COM4 Commands Via Serial Port Disabled
*$+YT4.0* *$+YT4.0*
COM4 Commands Via Serial Port Enabled With TMF
*$+YT4.1* *$+YT4.1*
COM4 Commands Via Serial Port Enabled Without TMF
*$+YT4.2* *$+YT4.2*
Notes:
For COM1 only. To provide compatibility with earlier TRAKKER Antares firmware versions, you can also use this syntax: ITdata where data is a value from 0 to 2.
9-39
Page 386
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de
39 Nugget
Controller Connect Check Receive Timer Purpose:
During periods of inactivity on the T2425, the terminal still sends messages to the DCS 300 to check the RF connection. If no message is received within the time set for the Controller Connect Check Receive Timer, the terminal is no longer connected to the DCS 300 and the Connect icon blinks. The timer countdown resets each time a valid message is received. Power Management Tip: Intermec strongly recommends that you use the optimum setting of 60 seconds to preserve the main battery pack’s power.
Syntax:
NPdata Acceptable values for data are any number from 1 to 3600 seconds (60 minutes).
Default: Scan:
60 seconds To set the default controller connect check receive timer, scan this bar code: Default Controller Connect Check Receive Timer
*$+NP60* *$+NP60*
Or:
To set the controller connect check receive timer: 1. Scan this bar code: Enter Accumulate Mode / Set Controller Connect Check Receive Timer
*+/$+NP* *+/$+NP*
2. Scan a numeric value for data from these bar codes:
*0* *0*
*2*
*1*
*3*
*2*
*3*
*4*
*5*
*4*
*6* *6*
9-40
*1*
*5*
*7*
*7*