TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Nugget Co de
39
Problems While Configuring the Terminal (continued) Problem
Solution
You are configuring the serial port and see this error message when exiting the Configuration Menu:
You must configure a value for EOM before you can set SOM or disable SOM. You need to change the value of SOM. Choose Serial Port from the Communications Menu.
Serial port configuration error.
The configurable serial protocol (CSP) uses EOM to determine the serial communications mode. When EOM is disabled, the terminal communicates in Character mode. When EOM is enabled, the terminal communicates in Frame mode. To use Frame mode, you need to set EOM first. Next, configure Handshake, Configuration Commands Via Serial Port, LRC, SOM, and then Poll.
SOM is set. You must also set EOM. Configuration was not updated.
For help, see “Using Serial Communications on the Terminals” in Chapter 4. You are configuring the serial port and see this error message when exiting the Configuration Menu: Serial port configuration error. SOM cannot equal EOM.
SOM cannot equal the same value that is set for EOM. You cannot set SOM to any of these values: AFF (ACK), DLE, NEG (NAK), Poll, RES (EOT), REQ (ENQ), SEL, XOFF, or XON. You need to change the value of SOM. Choose Serial Port from the Communications Menu. For help, see “Start of Message (SOM)” in Chapter 9.
Configuration was not updated. You are configuring the serial port and see this error message when exiting the Configuration Menu: Serial port configuration error.
EOM can be one or two ASCII characters, but you cannot set the first and second character to the same character. Also, you cannot set EOM to any of these values: AFF (ACK), DLE, NEG (NAK), Poll, RES (EOT), REQ (ENQ), SEL, XOFF, or XON. You need to change the value of EOM #1 or #2. Choose Serial Port from the Communications Menu.
EOM #1 cannot equal EOM #2. Configuration was not updated.
For help, see “End of Message (EOM)” in Chapter 9.
You are configuring the serial port and see this error message when exiting the Configuration Menu:
You cannot set EOM or SOM to any of these values: AFF (ACK), DLE, NEG (NAK), Poll, RES (EOT), REQ (ENQ), SEL, XOFF, or XON. You need to change the value of EOM or SOM. Choose Serial Port from the Communications Menu.
Serial port configuration error. DLE, XON, XOFF are not valid values for either SOM or EOM. Configuration was not updated.
6-10
For help, see “End of Message (EOM)” or “Start of Message (SOM)” in Chapter 9.
Page 281
Nugget
Co de
Troubleshooting 39
6
Problems While Configuring the Terminal (continued) Problem
Solution
You are configuring the serial port and see this error message when exiting the Configuration Menu:
PG is the Handshake configuration command. You need to change the value of Handshake or set other serial port parameters. Choose Serial Port from the Communications Menu.
PG command failed.
The order in which you set serial port protocol configuration commands is important. To use Frame mode, you need to set EOM first. Next, configure Handshake, LRC, SOM, and then Poll. To use Character mode, you need to disable these same parameters in reverse order.
Configuration was not updated.
For help, see “Using Serial Communications on the Terminals” in Chapter 4. You are configuring SOM or EOM in the Configuration Menu and cannot set two characters.
You may have a space in the SOM or EOM field. The space does not show, but it is a valid character. To clear a space from the field, put the cursor in the field and press . Now set the two-character value for SOM or EOM.
You are scanning a configuration command to set one of the serial port parameters and hear three low beeps. For example, you are trying to set EOM or SOM.
The order in which you scan serial port protocol configuration commands is important. The configurable serial protocol (CSP) uses EOM to determine the serial communications mode. When EOM is disabled, the terminal communicates in Character mode. When EOM is enabled, the terminal communicates in Frame mode.
d
To use Frame mode, you need to set EOM first. Next, configure Handshake, Configuration Commands Via Serial Port, LRC, SOM, and then Poll. To use Character mode, you need to disable these same parameters in reverse order. For help, see “Using Serial Communications on the Terminals” in Chapter 4. You see this error message when exiting the Configuration Menu:
Commandname command failed. Remainder of configuration not updated.
The two-character name (syntax) of the configuration command that failed is listed on the first line of the error message. For example, you may see this message: SS command failed. There may be a problem with the configuration due to a change made with the Scanner Selection (SS) command. Check the command listed in the message. To find the command, use the “Configuration Commands by Syntax” table in Appendix A. Make sure the command is set correctly for the options and network communications you are using with the terminal. For help, see Chapter 9, “Configuration Command Reference.”
6-11
Page 282
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Nugget Co de
39
Problems While Configuring the Terminal (continued) Problem
Solution
You scan a configuration command, such as Keypad Caps Lock, and you hear three low beeps.
If you are working in the TRAKKER Antares 2400 Menu System, you cannot scan configuration commands. Use the Configuration Menu to change the terminal’s configuration, or exit the menu system to scan configuration commands.
You scan a configuration command, such as Keypad Caps Lock, and nothing happens.
There are two possible solutions: • You may have one or more reader commands disabled, such as Change Configuration, so that you cannot change the configuration. Enable all of the reader commands and try again. • The terminal may be waiting for another command to complete the configuration change. If you started by scanning the Enter Accumulate command, you must finish the command by scanning the Exit Accumulate command. For help, see Chapter 9, “Configuration Command Reference.” Scan the Enable Override to temporarily enable all of the reader commands. When you are finished, remember to disable the override so that your data is not interpreted as a command. Enable Override
*$+DC3* *$+DC3* On the T2425, you scan a configuration command to set one of these parameters and hear three low beeps: • Controller IP Address (UDP Plus) or Host IP Address (TCP/IP) • Terminal IP Address • Default Router • Network Activate
If the Network Activate command is enabled (2.4 GHz RF network enabled) and you are configuring the T2425, these addresses must define a valid network configuration. For example, an invalid network configuration would be a controller (or host) IP address set to 0.0.0.0 with the network enabled. To set these four parameters, follow these steps: 1. Disable the Network Activate (NA) configuration command. 2. Set the terminal IP address and the controller IP address or the host IP address. 3. Set the default router address (if necessary). 4. Enable the Network Activate command. You can change an IP address with the network enabled as long as it still defines a valid network configuration.
6-12
Page 283
Nugget
Co de
Troubleshooting 39
6
Problems While Configuring the Terminal (continued) Problem
Solution
You scan or enter an option for the Scanner Selection configuration command and you hear three low beeps.
You may have scanned or entered a Scanner Selection command that does not apply to the type of scan module you have installed. Options SS0 through SS7 only configure the module for cabled scanners when installed. Options SS11 through SS13 only configure the long range or high density scan module when installed. Try scanning or entering the Scanner Selection command again and select an option the type of module you have installed. If you have a standard range scan module, you can scan options SS11 through SS13. However, since these commands configure the spotting beam for a long range or high density scan module, they do not change how the standard range scan module works.
T2425 Will Not Communicate With RF Network Devices If you cannot get the T2425 to communicate with other devices in the 2.4 GHz RF network, check these possible problems. Problem
Solution
The Radio icon on the terminal screen remains on.
Either the Network Activate command is disabled or there is a problem with the radio card and it is turned off. Make sure the Network Activate command is enabled. Use the TRAKKER Antares 2400 Menu System or scan the Network Activate command to enable the 2.4 GHz RF network and turn on the radio. For help, see “Network Activate” in Chapter 9. If the network is enabled and the Radio icon remains on, there may be a problem with the radio card. For help, contact your local Intermec service representative.
The Connect icon is not lit on the terminal screen. The T2425 is not communicating with the access point.
The T2425 is not connected to the access point. Make sure the access point is turned on and operating. You may also be using the terminal out of the RF range of an access point. Try moving closer to an access point to re-establish communications. In a TCP/IP direct connect network, you cannot scan or enter data when the T2425 is not communicating with an access point or you may lose your TCP session. Try moving closer to an access point to reestablish communications. Make sure the T2425 is configured correctly for your network. To communicate with the access point, the RF domain and RF security ID on the terminal must match the values set for all access points the terminal may communicate with. For help, see “Using RF Communications on the T2425s” in Chapter 4.
6-13
Page 284
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Nugget Co de
39
T2425 Will Not Communicate With RF Network Devices (continued) Problem
Solution
The Connect icon blinks on the terminal screen.
In a UDP Plus network, the terminal is not connected to the DCS 300. You may need to check the T2425 configuration, or make sure the DCS 300 is running and that data collection is started. The terminal may be out of range of an access point or the access point may have recently been turned off. Make sure the access point is still turned on.
*
Each device in the 2.4 GHz RF network must have a valid IP address. The IP addresses set on the terminal must match the addresses configured on the DCS 300 or host. For help, see “Using RF Communications on the T2425” in Chapter 4. The T2425 is connected to the host computer and you move to a new site to collect data. The Connect icon was on and now begins to blink or turns off.
You may have gone out of range of an access point. Try moving closer to an access point or to a different location to re-establish communications. Once you are in range again, the Connect icon will appear and remain on. Any data you collected while you were out of range will be transmitted over the network.
* The Connect icon blinks on the terminal screen and you see this message: Unable to connect to controller. Error 102. Unable to establish connection to host. Session ended.
The Connect icon remains on, but the host computer is not receiving any data from the T2425.
*
The Connect icon remains on, but you cannot establish a terminal emulation session with the host computer.
*
6-14
The T2425 is connected to the access point, but is trying to establish communications with the DCS 300 and the host computer. Make sure the terminal is correctly configured for your network. Make sure the DCS 300 is configured and running. Make sure the host computer is configured and running. If you have configured the network correctly, try restarting the DCS 300 to establish communications. You can also try resetting the terminal. For help resetting the terminal, see “Booting and Resetting the Terminal” later in this chapter. There may be a problem with the connection between the DCS 300 and the host computer. Check with your network administrator or use the DCS 300 System Manual to troubleshoot any potential problems on the controller. In a TCP/IP network, there may be a problem with the connection between the access point and the host computer. Check with your network administrator or use your access point user’s manual. There may be a problem with the host computer, a problem with the connection between the DCS 300 and the host computer, or a problem with the connection between the access point and the host (TCP/IP). Check with your network administrator to make sure the host is running and allowing users to login to the system.
Page 285
Nugget
Co de
Troubleshooting 39
6
T2425 Will Not Communicate With RF Network Devices (continued) Problem
Solution
When you turn on the terminal after it was suspended for awhile (10-15 minutes or longer), the terminal can no longer send or receive messages over the network.
The host may have deactivated or lost your current terminal emulation session. In a TCP/IP direct connect network, you need to turn off the “Keep Alive” message (if possible) from the host so that the TCP session is maintained while a terminal is suspended.
Problems Transmitting Data Through the Serial Port If you are having problems sending or receiving data through the serial port on the terminal, check these possible problems: •
Make sure the terminal is connected to the host computer or serial device through the TRAKKER Antares TD2400 Communications Dock, the TRAKKER Antares Optical Link Adapter, the TRAKKER Antares 242X serial interface module, or the modem.
•
Make sure you are using a null-modem RS-232 cable to connect the communications dock, optical link adapter, or the serial interface module to the host or serial device.
•
Make sure you are using an RJ11 cable to connect the T2420 modem to the phone jack.
•
Make sure an external power supply is connected to the communications dock and there is power to the electrical outlet.
•
Make sure an external power supply is connected to the optical link adapter or that you have a charged battery pack installed in the terminal.
•
Make sure the terminal’s serial port parameters are configured to match the serial port configuration on the host computer or serial device. For example, make sure the baud rate is the same.
For help connecting and configuring the serial port, see “Using Serial Communications on the Terminals” in Chapter 4.
6-15
Page 286
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Nugget Co de
39
Problems Transmitting Data Through the DCS 300 If you have a problem while running the application on the terminal in a UDP Plus network, check these possible communications problems. Problem
Solution
Transaction Buffer Full.
The buffer holding transactions to be sent to the controller is full. Stop collecting data with this terminal. Make sure the terminal is communicating with the DCS 300 and let the terminal send all the transactions in the buffer before you continue collecting data.
Sending Buffer Transactions.
This is an information message to tell you that buffered transactions are now being sent to the DCS 300. You can begin collecting data again once the message clears.
Transaction Aborted.
The transaction just sent to the DCS 300 was not received. Try sending the transaction again.
Transmit Error XX, press Enter.
There is an error transmitting data to the DCS 300. XX represents the status code error. Note the error code listed in the message and contact your local Intermec service representative for help. Press to continue.
Receive Error XX, press Enter.
There is an error receiving data from the DCS 300. XX represents the status code error. Note the error code listed in the message and contact your local Intermec service representative for help. Press to continue.
Shutting down.
The DCS 300 is shutting down. You may continue collecting data and buffer the transactions in the terminal until the DCS 300 starts again, or stop collecting data with the terminal.
Controller Shutdown.
The DCS 300 has shut down. You may continue collecting data and buffer the transactions in the terminal until the DCS 300 starts again, or stop collecting data with the terminal.
6-16
Page 287
Nugget
Co de
Troubleshooting 39
6
Bar Code Labels Will Not Scan If you cannot scan bar code labels or you are having problems with the scan module, check these possible problems. Problem
Solution
A scan module is not installed.
Make sure a scan module is installed correctly. You must install a module for cabled scanners, a standard range scan module, or a long range scan module, or a high density scan module before you can use the terminal.
The terminal is turned off.
Make sure the terminal is turned on. Press
You cannot see a red beam of light from the integrated scan module when you press the Scan button and aim the scanner at a bar code label.
There are two possible problems:
L to turn on the terminal.
• You may be too far away from the bar code label. Try moving closer to the bar code label and scan it again. • You may be scanning the bar code label “straight on.” Try changing the scanning angle until the laser beam is the brightest. This is the best scanning angle. You can test the effective range of the scanner. Move within 2 feet of a wall and test the scanner. You need to be within the scanning range to scan bar code labels. For help on scanning distances, see “Physical and Environmental Specifications” in Appendix A.
Warning Do not look directly into the window area or at a reflection of the laser beam while the laser is scanning. Long-term exposure to the laser beam can damage your vision. Avertissement Ne regardez pas directement la réflexion d’un rayon laser ou dans la fenêtre du laser lorsque celui-ci est en opération. Si vous regardez trop longtemps un rayon laser, cela peut endommager votre vue. An input device is not attached to the module for cabled scanners.
Make sure an input device, such as a 1550 laser scanner, is attached correctly to the module for cabled scanners. You must install an input device before scanning bar code labels.
The integrated scan module does not read the bar code labels quickly, or the scanning beam seems to be faint or obscured.
The scan module window may be dirty. Clean the scanning window of the scan module with a solution of ammonia and water. Wipe dry. Do not allow abrasive material to touch the window.
6-17
Page 288
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Nugget Co de
39
Bar Code Labels Will Not Scan (continued) Problem
Solution
You have an input device attached to the module for cabled scanners and cannot read any bar code labels.
You may not be using an input device that is supported with the module for cabled scanners. Make sure you are using one of the supported input devices: • • • • •
The scan module or input device will not read the bar code label.
Intermec 126X, 127X, and 128X wands Intermec 146X CCD scanners Intermec 151X, 1545, and 155X laser scanners Compatible Symbol scanners (reverse polarity enabled) Tethered long range scanner
Try one of these solutions: • Make sure you aim the scanner beam so it crosses the entire bar code label in one pass. • The angle you are scanning the bar code label may not be working well, or you may be scanning the label “straight on.” Try scanning the bar code label again, but vary the scanning angle. • The bar code label print quality may be poor or unreadable. To check the quality of the bar code label, try scanning a bar code label that you know scans. Compare the two bar code labels to see if the bar code quality is too low. You may need to replace the label that you cannot scan. • Make sure the bar code symbology you are scanning is enabled. Use the TRAKKER Antares 2400 Menu System to check the symbologies. On the Symbologies Menu, each symbology that is enabled has an asterisk (*) next to the name of the symbology. If your bar code symbology is disabled, enable it and then try scanning the bar code label again.
The input device connected to the module for cabled scanners does not appear to work well or read bar code labels very quickly.
Try setting the Scanner Selection command to the specific input device you have attached. Check the bar code symbologies you have enabled on the terminal. Enable only the symbologies that you are using.
When you press the Scan button, the scanner LEDs at the top of the keypad do not light up.
Move within 2 feet of a wall and press the Scan button again. Make sure the scan module emits the red laser beam. If the LEDs do not light, there may be a problem with them. For help, contact your local Intermec service representative. If the laser beam does not turn on, check the other problems in this section for a possible solution.
6-18