Bar Code Labels Will Not Scan (continued) Problem
Solution
When you release the Scan button, the scanner LEDs at the top of the keypad do not turn off.
The scanner LEDs will remain on if you configure the terminal to use edge triggering. If you configure the terminal for level triggering and the scanner LEDs remain on, there may be a problem with the LEDs. Press the Scan button again without scanning a bar code label. If the LEDs are still on, contact your local Intermec service representative.
Guidelines for Managing Batteries Follow these guidelines to manage the terminal batteries, prevent problems, and preserve battery power. For more help on charging or replacing batteries, see “Learning About the Terminal’s Batteries” in Chapter 2. Main Battery Pack
• ALWAYS turn off the terminal BEFORE you remove the main battery pack. • ALWAYS keep a charged or partially charged main battery pack in the terminal. • Keep a spare, charged main battery pack on hand. • If the Battery icon appears and remains on solid, you have a low main battery pack, replace or charge the battery pack as soon as possible. • When you remove a low main battery pack from the terminal, recharge the battery pack you just removed. • If the terminal turns off due to a low main battery pack, do not turn on the terminal. Replace or charge the main battery pack before you continue using the terminal. • Use the battery charger to charge the main battery pack. Charge the main battery pack for a minimum of 2 hours to make sure the battery pack is fully charged.
Backup Battery
• If you have a low backup battery, turn off the terminal. Insert a fully charged main battery pack. The main battery pack will fully charge the backup battery in approximately 18 hours. • ALWAYS turn off the terminal BEFORE you remove the backup battery.
Storing the Terminal
• If you are going to store the terminal for less than 2 weeks, keep both batteries installed in the terminal. Insert a fully charged main battery pack before you store the terminal. • If you are going to store the terminal for more than 2 weeks, save your data and end your TE or screen mapping session to minimize the risk of data loss. Remove both the main battery pack and the backup battery from the terminal.
6-19
Page 290
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Nugget Co de
39
Guidelines for Managing Batteries (continued) Cold Temperatures (Using the terminal in sub-freezing environments)
6-20
•
If you use the terminal in a cold temperature environment, battery life will be reduced. Battery life depends on temperature, battery model, input device, age of the battery pack, your usage, and duty cycle factors. If you use the terminal for extended periods of time in sub-freezing environments, you may need to change the main battery pack more often.
•
Do not store the terminal in a cold temperature environment. When you are not using the terminal, keep it in a warmer area to make sure the battery chargers will continue operating.
•
If the Battery icon blinks, the backup battery charge is low. Move the terminal to a warmer environment to charge the backup battery. The backup battery charger operates between 32°F and 104°F (0°C and 40°C). If you are using the terminal in an area outside this temperature range, the backup battery will not charge.
•
Store the battery chargers and spare batteries in a warm (office) environment to ensure the most efficient operation.
•
Charge the main battery pack in an area or room where the temperature is above freezing.
•
If you have been using the terminal in a cold temperature environment and need to replace or charge either battery, let the batteries warm up for a half hour before you charge them.
Page 291
Nugget
Co de
Troubleshooting 39
6
Booting and Resetting the Terminal You seldom need to boot or reset the terminal. When you boot the terminal, it runs through power-on self test (POST) to test each major subsystem. The terminal uses the configuration currently saved in flash memory. Once the terminal is finished booting, your application appears on the screen. You only need to reset the terminal when the terminal or an application are locked up and will not respond to any key sequences. The terminal also boots and resets after a firmware upgrade or if you remove both batteries. The next instructions explain how you boot and reset the terminal.
Booting the Terminal You can boot the terminal using these two methods:
L key to boot the terminal when you turn on the terminal.
•
Configure the
•
Use the Boot Menu.
Booting the Terminal on Resume
L to turn off the terminal, it turns off and goes into Suspend mode. L to turn on the terminal, it resumes or boots depending on the terminal There are two ways to configure the L key using the Resume Execution configuration When you press When you press configuration. command:
Resume Execution Not Allowed Configures the terminal to boot and restart your application each time you press to turn on the terminal. Use this option if you want to restart your application every time you turn on the terminal.
L
Resume Execution Allowed Configures the terminal to resume exactly where it was when you turned off the terminal. Use this option to resume working each time you turn on the terminal. You can configure the Resume Execution command by using the TRAKKER Antares 2400 Menu System or by scanning these bar code labels. For help, see Chapter 3, “Configuring the Terminal,” or “Resume Execution” in Chapter 9. Resume Execution Not Allowed
Resume Execution Allowed
*$+ER0*
*$+ER1*
*$+ER0*
*$+ER1*
6-21
Page 292
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Nugget Co de
39
Using the Boot Menu The Boot menu appears after you: • remove both batteries, install them again, and turn on the terminal.
• upgrade the firmware.
• reset the terminal.
BOOT MENU b - Boot System l - Run Loader q - Power Down
POWER DOWN IN 60 SEC 242XU.104
The Boot Menu contains these commands: Boot System If you did remove the batteries, make sure you install a charged main battery pack or the terminal will not turn on. Press to boot the terminal. Once the terminal is finished booting, your application appears on the screen.
!
+
Run Loader Press to load the terminal firmware. To upgrade or load the firmware, you should use the Firmware Upgrade option in the TRAKKER Antares 2400 Menu System. For help, see “Upgrading the Firmware” in Chapter 3.
0
Power Down Press to turn off the terminal. When you turn on the terminal, the Boot Menu screen appears again if POST passes.
Resetting the Terminal If the terminal or application is locked up and the terminal will not respond to any key sequences, you can reset the terminal. Before you reset the terminal, try the following in order:
L to turn off the terminal.
•
Press
•
Scan the Reset Firmware label to restart the firmware and application. Reset
*-.* *-.*
6-22
Page 293
Nugget
Co de
Troubleshooting 39
6
If the terminal or application still will not respond, reset the terminal. To reset the terminal •
Scan the Boot Terminal label to reboot the terminal. Boot Terminal
*-.1* *-.1*
Or if the terminal will not scan you can perform this procedure: 1. Place the terminal on a flat surface.
L to turn off the terminal. If it will not turn off, continue with the next step. 3. Press and hold the and keys at the same time and then press L while still 2. Press pressing the other keys. The green scanner LEDs light and the terminal turns off. Release the keys. Tip: It helps to press the left side of the
4. Press key in this key sequence.
L to turn on the terminal. The Boot Menu appears. BOOT MENU b - Boot System l - Run Loader q - Power Down
POWER DOWN IN 60 SEC 242XU.104
Note: If the terminal returns to the exact same screen, the reset sequence did not work. Repeat Step 1. Make sure you press and hold the and keys, and then press the key.
!
L
5. Press to boot the terminal. Once the terminal has finished booting, your application appears. If the terminal still will not reset or boot, try loading the firmware. For help, contact your local Intermec service representative.
6-23
Page 294
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Nugget Co de
39
Maintaining and Cleaning the Terminal The terminals are built for use in a rugged, industrial working environment. You may need to perform these minor maintenance tasks to keep the terminal in good working order: •
Replace the antenna on the T2425.
•
Clean the screen.
•
Clean the scan module window.
The antenna is one of the few exposed parts that may be damaged while you use the T2425. You can order and replace the antenna using the instructions in this section. If you do have problems with other mechanical parts, contact your local Intermec service representative for help. Clean the scan module window and terminal screen as often as needed for the environment in which you are using the terminal. Each procedure is described in detail in this section. To order replacement parts, contact your local Intermec service representative or contact Intermec at: Intermec Corporation 6001 36th Ave. West P.O. Box 4280 Everett, Washington 98203-9280 Telephone: 1-425-348-2600
Replacing the Antenna If your antenna on the T2425 is damaged, you can replace it. To replace the antenna, you need these items: •
2.4 GHz SMB antenna (Part No. 063825)
•
Retaining ring (Part No. 064101)
•
Small straight-slot screwdriver
To replace the antenna 1. Rotate the antenna to line up the alignment marks on the connector end of the antenna with the alignment marks on the T2425 antenna connector. 2. Insert the straight-slot screwdriver into the retaining ring opening so that the screwdriver is in the retaining ring slot.
6-24
Page 295
Nugget
Co de
Troubleshooting 39
6
Removing the Antenna Retaining ring opening
Antenna (must be in this position)
242XU.147
3. Pry the retaining ring up out of the opening and remove it. 4. Gently pull the antenna off the antenna connector on the T2425. 5. Line up the alignment marks on the connector end of the antenna with the alignment marks on the terminal antenna connector. Retaining ring slot Retaining ring opening
Antenna (must be in this position)
Retaining ring
242XU.119
6-25
Page 296
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Nugget Co de
39
6. Push the new antenna onto the antenna connector until it fits flush and the opening for the retaining ring is visible. 7. Insert the retaining ring into the opening. 8. Push the retaining ring down until it is locked in place. 9. Turn the T2425 over and adjust the angle of the antenna as needed.
Cleaning the Scan Module Window and Terminal Screen To keep the terminal in good working order, you need to clean the scan module window and terminal screen. Clean these surfaces as often as needed or when they are dirty. To clean the scan module window and terminal screen 1. Press
L to turn off the terminal.
2. Use a solution of ammonia and water. 3. Dip a clean towel or rag in the ammonia solution and wring out the excess solution. Wipe off the scan module window and terminal screen. Do not allow any abrasive material to touch these surfaces. 4. Wipe dry.
6-26