Page 271

6 Troubleshooting

Page 272

6-2

Page 273

Nugget

Co de

Troubleshooting 39

6

This chapter lists the problems you may have while using the terminal and gives some possible solutions. You will also find instructions that explain how to replace the antenna and clean parts of the terminal.

How to Use This Chapter If you have any problems with the TRAKKER Antares 2420 or 2425 terminal, use this table as a guide to find the problem and solution in this chapter: Problem

See This Section to Find a Solution

Page

Screen is blank.

“Terminal Will Not Turn On”

6-5

Terminal locked up or message is displayed.

“Problems While Operating the Terminal”

6-5

Configuring the terminal

“Problems While Configuring the Terminal”

6-8

RF communications error

“T2425 Will not Communicate With RF Network Devices”

6-13

Serial port communications error

“Problems Transmitting Data Through the Serial Port”

6-15

Application error

“Problems Transmitting Data Through the DCS 300”

6-16

Scanning labels

“Bar Code Labels Will Not Scan”

6-17

Battery management

“Guidelines for Managing Batteries”

6-19

Boot Menu appears or terminal is locked up.

“Booting and Resetting the Terminal”

6-21

Antenna is damaged, the terminal screen is dirty, or the scan window is dirty.

“Maintaining and Cleaning the Terminal”

6-24

Note: If you have problems with the 3270, 5250, or VT/ANSI terminal emulation application, see the TRAKKER Antares Terminal Emulation User’s Guide.

6-3

Page 274

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Nugget Co de

39

Finding and Solving Problems If you have a problem while configuring or using the terminal, use the tables in this section to find a solution. For easy reference, problems are grouped into these topics: •

Terminal Will Not Turn On

•

Problems While Operating the Terminal

•

Problems While Configuring the Terminal

•

T2425 Will Not Communicate With RF Network Devices

•

Problems Transmitting Data Through the Serial Port

•

Problems Using the Screen Mapping Application

•

Bar Code Labels Will Not Scan

•

Guidelines for Managing Batteries

Note: You can also use the diagnostics to help analyze and solve problems. For help, see Chapter 7, “Running Diagnostics.” Caution There are no user-serviceable parts inside the terminal. Opening the unit will void the warranty and may cause damage to the internal components. Conseil La terminal ne contient pas de pièces révisibles par l’utilisateur. Le fait d’ouvrir l’unité annule la garantie et peut endommager les pièces internes. If you send the terminal in for service, it is your responsibility to save the terminal data and configuration. Intermec is responsible only for ensuring that the keypad and other hardware features match the original configuration when repairing or replacing your terminal.

6-4

Page 275

Nugget

Co de

Troubleshooting 39

6

Terminal Will Not Turn On

L

If you press to turn on the terminal and nothing happens, check the terminal for these possible problems. For more help, see Chapter 1, “Getting Started.” Problem

Solution

A scan module or a serial module is not installed.

Make sure a scan module or a serial module is installed correctly. You must install a module before you can turn on the terminal.

A main battery pack is not installed. You see the Battery icon on the top line of the screen.

Remove the battery door on the terminal and make sure the main lithium-ion battery pack is installed correctly. Slide the battery pack toward the top of the terminal to lock the battery pack into the connectors.

The main battery pack is not charged. You see the Battery icon on the top line of the screen.

The main battery pack may be discharged. Replace the battery pack with a spare charged battery pack, or charge the battery pack and try again.

Problems While Operating the Terminal If you are operating the terminal and have trouble, check these possible problems and solutions. Problem

Solution

You scan a reader command, such as Backlight On, and nothing happens.

The reader commands are disabled. Scan the Enable Override command shown here to temporarily enable all of the reader commands. You can also enable or disable reader commands with the TRAKKER Antares 2400 Menu System. For help, see “Command Processing” in Chapter 9. When you are finished, remember to disable the override so that your data is not interpreted as a command. Enable Override

*$+DC3* *$+DC3* You scan a valid bar code label to enter data for your application. The data decoded by the scan module does not match the data encoded in the bar code label.

The terminal may have decoded the bar code label in a symbology other than the label’s actual symbology. Try scanning the bar code label again. Make sure you scan the entire label. To operate the terminal quickly and efficiently, you should enable only the bar code symbologies that you are going to scan. If you enable multiple symbologies, the terminal may on rare occasions decode a bar code according to the wrong symbology and produce erroneous results.

6-5

Page 276

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Nugget Co de

39

Problems While Operating the Terminal (continued) Problem

Solution

You want to set the terminal back to the default configuration to start over configuring the terminal.

Scan this bar code label: Default Configuration

*.+* *.+* Or, use the TRAKKER Antares 2400 Menu System. For help, see “Restoring the Terminal’s Default Configuration” in Chapter 3. Note: After you load the default configuration on a T2425, you may need to set the primary network communications parameters to communicate with other devices in the 2.4 GHz RF network.

You cannot scan bar code labels with a scan module or the module for cabled scanners.

See “Bar Code Labels Will Not Scan” later in this chapter.

The terminal appears to be locked up and you cannot enter data.

Try these possible solutions: • (T2425 only) Wait at least 10 seconds and try again. If the T2425 is still connecting to the DCS 300 or host, the T2425 ignores any input from the keypad or scanner. Make sure the Connect icon appears and remains on before continuing. • Scan any bar code label to see if the terminal responds.

L

• Press to turn off the terminal. If it turns off, press the terminal. You can continue working.

L to turn on

• If the terminal will not turn off, reset the terminal. Press and hold the and keys, and then press . The green Scanner LEDs light and the terminal turns off. Release the keys.

L

L

Press to turn on the terminal. It boots all the systems, clears RAM memory, and starts your application.

L

Note: If the terminal does not boot when you press , the reset did not work. Press and hold the and keys first, then press .

L

• Remove the main battery pack and disconnect the backup battery. Let the terminal sit for 1 minute. Install the battery pack and connect the backup battery. Press to turn on the terminal.

L

• If you keep returning to the Boot Menu, try loading the firmware. For help, see “Upgrading the Firmware” in Chapter 3. • If the terminal will not boot or reset, contact your local Intermec service representative for help.

6-6

Page 277

Nugget

Co de

Troubleshooting 39

6

Problems While Operating the Terminal (continued) Problem

Solution

The terminal is booting and you see a message that POST failed.

The screen displays the system that failed POST. Report the error message to your supervisor.

?

!

Press to exit the error message. The Boot Menu appears. Press to boot the terminal. Your application appears on the screen. If the terminal still will not boot, contact your local Intermec service representative for help. The terminal displays the Boot Menu.

You will see the Boot Menu in these two situations: • You remove both batteries at the same time. Once you replace the batteries and turn on the terminal, the Boot Menu appears. Press to boot the terminal and continue working.

!

• You just finished upgrading the firmware on the terminal and POST failed. Press to boot the terminal. Report the problem to your supervisor.

!

For help on the Boot Menu, see “Booting and Resetting the Terminal” later in this chapter. You insert a main battery pack and cannot shut the battery door.

If you are using an Intermec-labeled battery pack (Part No. 063278), make sure you remove the rubber bumper from the inside of the battery door. Try closing the battery door again. If you are using a Sony-labeled battery pack, make sure the rubber bumper is installed over the ridge near the wall on the inside of the battery door. Try closing the battery door again. The rubber bumper on the battery door keeps the battery pack in place.

You insert a main battery pack. The terminal will not turn on and the Battery icon is not displayed.

The main battery is completely discharged of power. The terminal does not even register enough power to identify a main battery pack and display the Battery icon. Replace the main battery pack with a spare charged battery pack, or charge the battery pack.

The Battery icon blinks on the top line of the terminal screen.

The backup battery charge is low, or the backup battery is not connected. Make sure the backup battery wire connectors are firmly locked together. Check the wires leading into the backup battery and the bottom case for any damage or loose connections.

Note: The terminal is not beeping.

Make sure a main battery pack is installed and connected. Turn off the terminal. Let the main battery pack charge the backup battery. The backup battery will be fully charged in approximately 18 hours. If you have been using the terminal in a cold temperature environment, move the terminal to a warmer environment to charge the backup battery. If the backup battery will not charge, you may need to replace it. For help, contact your local Intermec service representative.

6-7

Page 278

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Nugget Co de

39

Problems While Operating the Terminal (continued) Problem

Solution

You see both these symptoms:

The main battery pack charge is low. You have a few minutes of power left. Replace the main battery pack with a spare charged battery pack, or charge the battery pack.

• The Battery icon remains on solid. • The terminal beeps once every 15 seconds. You see both these symptoms: • The Battery icon blinks. • The terminal beeps once every 15 seconds.

The main battery pack charge and the backup battery charge are both low. Immediately turn off the terminal. Replace the main battery pack with a spare charged battery pack. Let the main battery pack charge the backup battery. The backup battery will be fully charged in approximately 18 hours. If you have been using the terminal in a cold temperature environment, move the terminal to a warmer environment to charge the backup battery. If the backup battery will not charge, you may need to replace it. For help, contact your local Intermec service representative.

Problems While Configuring the Terminal You can configure the terminal by using the TRAKKER Antares 2400 Menu System or by scanning configuration commands. If you have problems configuring the terminal, check these possible problems and solutions. Problem

Solution

On the T2425, you configure the RF security ID and the changes do not appear to be saved.

You can only set the RF security ID with the 2.4 GHz RF network enabled. The Network Activate configuration command must be configured to 2.4 GHz RF network before you can save any changes to the RF security ID command.

On a T2425, you see this error message when exiting the Configuration Menu:

The 2.4 GHz RF network is enabled and there is a problem with the network configuration. You need to change the terminal IP address and/or the controller IP address (host IP address for a TCP/IP network). Choose Primary Network from the Communications Menu.

Network configuration error. Network is enabled. Terminal IP address or Controller (Host) IP address set to an invalid address of 0.x.x.x or 127.x.x.x. Configuration was not updated.

6-8

The terminal IP address or the controller/host IP address is set to 0.x.x.x or 127.x.x.x. These are invalid addresses. Set a valid IP address for the terminal and controller or host. For help, see “Using RF Communications on the T2425” in Chapter 4. If you cannot fix the addressing problem, check with your network administrator to get the IP address assigned to the terminal and the controller or host.

Page 279

Nugget

Co de

Troubleshooting 39

6

Problems While Configuring the Terminal (continued) Problem

Solution

On a T2425, you see this error message when exiting the Configuration Menu:

The 2.4 GHz RF network is enabled and there is a problem with the network configuration. You need to change the terminal IP address and/or the default router address. Choose Primary Network or Advanced Network from the Communications Menu.

Network configuration error. Network is enabled. Terminal IP address and Default Router address set to the same address. Configuration was not updated.

The terminal IP address and the default router address are both set to the same address. Set a valid IP address for the terminal and the default router. For help, see “Using RF Communications on the T2425” in Chapter 4. If you cannot fix the addressing problem, check with your network administrator to get the IP addresses for each RF network device.

On a T2425, you see this error message when exiting the Configuration Menu: Network configuration error. Network is enabled. Terminal IP address or Controller (Host) IP address set to the same address. Configuration was not updated.

The 2.4 GHz RF network is enabled and there is a problem with the network configuration. You need to change the terminal IP address and/or the controller IP address (host IP address for a TCP/IP network). Choose Primary Network from the Communications Menu. The terminal IP address and the controller/host IP address are both set to the same address. Set a valid IP address for the terminal and DCS 300 or host. For help, see “Using RF Communications on the T2425” in Chapter 4. If you cannot fix the addressing problem, check with your network administrator to get the IP address assigned to the terminal and the controller or host.

On a T2425, you see this error message when exiting the Configuration Menu: Network configuration error. Network is enabled. Default Router address is not on the terminal’s network. Configuration was not updated.

The 2.4 GHz RF network is enabled and there is a problem with the network configuration. You need to change the default router address. Choose Advanced Network from the Communications Menu. The terminal and DCS 300 (UDP Plus network) or host (TCP/IP network) are on different networks, and the terminal is not on the same network as the default router. When the terminal is on a different IP subnetwork from the DCS 300 or host, you must set the Default Router and Subnet Mask commands. Set a valid IP address for terminal, DCS 300 or host, and default router. For help, see “Using RF Communications on the T2425” in Chapter 4. If you cannot fix the addressing problem, check with your network administrator to get the IP addresses for each RF network device.