Page 223

Co de

39 Nugget Operating the Terminal in a Network

4

Connecting the Terminal to Another Device You can physically connect the terminal to another device using one of these accessories. TRAKKER Antares TD2400 Communications Dock Connect the communications dock to a device (host computer, printer, or other serial device) using an RS-232 null-modem serial cable. Connect the power supply to the dock. Insert the terminal in the dock. You can transfer data between the terminal and the device connected to the dock. For help, see the TRAKKER Antares TD2400 Communications Dock Quick Reference Guide. 25 S 24 ARE ANT

KER

TRAK

To host computer or device To power supply

I/O F5 F4 F3 F1

9

F2

8 6

7

5 3

4

2 1

0 Enter E

Fn R D

Fn L

C

J I

B

O

H

A

N

G

T

M

F L

S Y

R

K

X

Q

Esc

W

P V

Tab

U

24

25

Z

TD2400 communications dock

242XU.161

S

RE

TA

T

R A

K

K

E R

AN

24

20

TRAKKER Antares Optical Link Adapter Connect the optical link adapter to a device (host computer, printer, or other serial device) using an RS-232 null-modem serial cable. Connect the power supply to the optical link adapter (optional). Connect the optical link adapter to the serial port on the end of the terminal. You can transfer data between the terminal and the device connected to the optical link adapter. For help, see the TRAKKER Antares Optical Link Adapter Quick Reference Guide.

F5

9

I/O

F4

6

F3

8

F2

7

5

3

F1

0

4

2

Optical link adapter

1 ter

E

En Fn Fn G

L

J

D

R C

O

I

L

X

R

P c

Es

W

Q

K

Y

S

M F

T

N

H

B A

V b

Ta

U Z

242U.164

4-11

To host computer or device

To power supply

Page 224

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

39 Nugget

TRAKKER Antares Serial Interface Module Replace the scan module on the terminal with the serial interface module. If you are using the RS-232 adapter cable, connect the Stewart 10-pin connector of the cable into the serial port on the serial interface module. Connect the DB9 connector on the adapter cable to the DB9 connector of the null modem interface cable. Plug the other end of the null modem interface cable into COM1 or COM2 on your PC or printer. You can transfer data between the terminal and the device connected to the serial interface module. For help, see the TRAKKER Antares 242X Serial Interface Module Instruction Sheet.

Serial interface module Stewart 10-pin connector

Serial port DB9 connectors

RS-232 adapter cable

PC COM ports

Back of PC

Null modem interface cable 242XU.197

4-12

Page 225

Co de

39 Nugget Operating the Terminal in a Network

4

E sc

N

T

Y

S

X

R

W

F

Q

K

V

P

Z

U

Ta b

H

B

M

A

L

G

Fn

L

I

C

O

Fn

R

D

J

E

E nt er

1

0

4

2

7

5

3

F1

8

F2

6

F3

9

I/O

F4

F5

T

R A

K

K

E

R

AN

24

TA RE S

20

T2420 Modem Plug one end of an RJ11 cable into the connector on the T2420. Plug the other end of the cable into a phone jack. You can transfer data between the terminal and the device connected to the other end of the phone line.

To phone line 242XU.198

Choosing a Communications Protocol Once the terminal is connected to a host computer or other serial device, you are ready to configure the serial port parameters on the two devices. The terminal uses a communications protocol and XMODEM or YMODEM to handle data communications through the serial port. You can configure a different communications protocol for each COM port. The terminal’s built-in file operations use XMODEM or YMODEM for file transfer. Communications protocols determine exactly how data is transmitted between the terminal and the connected device. Each protocol has parameters you can set, such as baud rate and parity. Both the terminal and the connected device must use the same protocol and parameter settings to communicate properly. The terminal can communicate in these four protocols:

4-13

•

Binary

•

Configurable

•

Master Polling

•

Polling Mode D

Page 226

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

39 Nugget

Binary Protocol Binary protocol has no protocol. Characters are sent and received without being altered. The Data Link Escape character (DLE) is not inserted before any character. DLE characters are not stripped out of the incoming data stream and no characters such as EOM or SOM are added. Here are the serial port parameters you can define: •

Baud rate

•

Data bits

•

Parity

•

Stop bits

•

Flow control

Configurable Protocol Configurable protocol is based on Intermec’s Polling Mode D protocol except that you have the option to change some of the serial port protocol parameters or remove specific events from the protocol, such as Poll or handshake. Here are the serial port parameters you can define: •

Baud rate

•

Data bits

•

Parity

•

Stop bits

•

Configuration commands via serial port

•

EOM (End of Message)

•

Flow control

•

Handshake (enabled or disabled)

•

LRC

•

Poll (Polling) (enabled or disabled)

•

SOM (Start of Message)

•

Timeout Delay

Configurable protocol uses EOM to determine the serial communications mode. When EOM is disabled, the terminal communicates in Character mode. When EOM is enabled, the terminal communicates in Frame mode. Once EOM is enabled, you can set a value for these serial port parameters: •

Configuration commands via serial port

•

Handshake

•

LRC

•

SOM

Once Handshake is enabled, you can set a value for poll and the timeout delay.

4-14

Page 227

Co de

39 Nugget Operating the Terminal in a Network

4

Master Polling Protocol Master Polling Mode D protocol requires the terminal to ask the downline serial device for data it may have (polling) and to request to send data to the serial device (selecting). There is no automatic polling, so your application must poll periodically for data. Before each transmit operation, the terminal issues the SEL sequence for the device addressed and sends the data if an acknowledge is received. Before each receive operation, the terminal issues a poll sequence and waits for data or the RES character (no data is available to send). Here are the serial port parameters you can define: •

Baud rate

•

Flow control

Polling Mode D Protocol Polling Mode D protocol requires the host computer to ask the terminal for data it may have (polling) and to request to send data to the terminal (selecting). Polling Mode D uses an RS-232 or an RS-422 interface. Use this protocol if you want to connect to a 900 MHz RF network via the 9189 RF Gateway. Here are the serial port parameters you can define: •

Baud rate

•

Flow control

Configuring the Serial Port Parameters The values you set for the terminal serial port must match the values set for the serial port on the connected device. There are three ways to configure the terminal’s serial port parameters: •

Use the TRAKKER Antares 2400 Menu System. For help on configuring the parameters, see “Configuring the Serial Port Parameters” in Chapter 1.

•

Scan the configuration command from a Code 39 or Code 93 bar code label. The configuration commands are listed alphabetically by command name in Chapter 9, “Configuration Command Reference.”

•

Send a command from an application through the serial port on the host computer. For help, see the next section, “Configuring the Terminal Via the Serial Port.”

If you are configuring the serial port parameters in the TRAKKER Antares 2400 Menu System, you may not see all of the serial port parameters until you set a value for another key field. For example, EOM is a key field when you configure the Configurable protocol. That is, several fields are invalid (do not appear) until you enable EOM. If you are configuring the serial port parameters by scanning or sending configuration commands, the terminal will accept and set all serial port commands. However, the terminal only uses the parameters that are valid for the current protocol configuration. For example, if you are using configurable protocol on COM1, you can set a value for poll, but the terminal will not use it if handshake is not enabled.

4-15

Page 228

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

39 Nugget

Once the terminal is connected and configured, you can transfer data between the terminal and the device that is connected to the serial port. For help transferring files, see Chapter 5, “Using Custom Applications.”

Configuring the Terminal Via the Serial Port You can use an application on the host computer to configure the terminal by sending commands through the serial port. For example, you may want to change the Beep Volume command and the Display Backlight Timeout command. To send and receive configuration data, you need to write an application for the host that can communicate with the terminal through the serial port. You must connect the terminal to the host by using the communications dock, optical link adapter, serial interface module, or modem. Once the terminal is communicating, you can configure it. You must enable Frame mode and the Configuration Commands Via Serial Port command to configure the terminal through the serial port. For help, see Chapter 9, “Configuration Command Reference.” Note: You can continue running an application on the terminal while configuring the terminal from the host. To set up the application •

Prepare and write a host application that can send transactions to and receive transactions from the terminal in this format: [SOM]

[TMF field]

Configuration command

EOM where: [SOM] is the start of message field.

[TMF field] is only used if the Configuration Commands Via Serial Port are enabled with TMF (Terminal Message Format). It is a 2-byte field containing one of these values: CG Cg CS Cs

Configuration Get request sent from the host application. Configuration Get response sent from the terminal to the host. Configuration Set request sent from the host application. Configuration Set response sent from the terminal to the host.

Note: If the Configuration Commands Via Serial Port are enabled without TMF, leave this field blank.

4-16

Page 229

Co de

39 Nugget Operating the Terminal in a Network configuration command

4 is the reader or configuration command or commands you want to set on the terminal, or get the current value of from the terminal. To save configuration changes in flash memory, send the reader command .+1 as the last command. For a list of commands, see Chapter 8, “Reader Command Reference,” or Chapter 9, “Configuration Command Reference.”

EOM is the end of message field.

Note: To send data to an application instead of sending configuration commands, use the letter A followed by a space in the TMF field. If the TMF field does not contain CG, Cg, CS, Cs, or A , the terminal ignores the transaction. Example with TMF In the host application, you want to set the value for two configuration commands on the terminal. Send this transaction from the host application: CS$+BV4DF30.+1

Note: SOM and EOM are not shown in this example. where: CS is a TMF Configuration Set request.

$+ is the Change Configuration reader command.

BV4 sets the Beep Volume configuration command to a value of 4, which is a very loud beep volume.

DF30 sets the Display Backlight Timeout configuration command to a value of 30 seconds.

.+1 is the reader command that saves configuration changes to the terminal’s flash memory.

The terminal returns this transaction to the host application. Cs$+BV4DF30.+1 where:

4-17

Cs is a TMF Configuration Set response.

$+ is the Change Configuration reader command.

BV4 means the Beep Volume configuration command has been changed to a value of 4, which is a very loud beep volume.

DF30 means the Display Backlight Timeout configuration command has been changed to a value of 30 seconds.

.+1 means the configuration changes have been saved in flash memory.

Page 230

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

39 Nugget

Using RF Communications on the T2425s Before you can begin using the T2425 to collect data, you need to install and configure each device in the 2.4 GHz RF network by performing these steps: 1. Plan and prepare your network. Make sure you have all the equipment required to use the T2425 in the network. Make sure you have IP addresses for all devices in the network. 2. (UDP Plus network only) Configure the DCS 300. 3. Configure the access points. 4. Configure each terminal. Each step is described in detail in the next sections. Caution Make sure all components with antennas are at least 1 feet (30 centimeters) apart when power is applied. Failure to comply could result in equipment damage. Conseil Assurez-vous que la distance entre tous les éléments avec antennes soit d'au moins un pied (30 centimètres) avant de faire la connexion avec l'alimentation électrique, faute de quoi vous risquez d'endommager votre installation.

Planning the Network Connection To use the T2425 in the RF network, you need these minimum requirements: • •

(UDP Plus network) DCS 300 Access point

When you first consider purchasing a wireless data collection system, an Intermec representative works with you to perform a site survey at your facility. The site survey analyzes the range of radio frequency devices in your facility and determines the placement of the access points. The site survey ensures that the coverage of each access point overlaps to provide uninterrupted wireless access at any location within the building. This manual assumes that a site survey is complete and the access points are installed in your facility. You need to work with your network administrator to plan and assign the IP address for each device in the RF network. You must assign and set the IP address for each access point, and each terminal. For a T2425 with UDP Plus, you must also assign an IP address to the DCS 300.

4-18

Page 231

Co de

39 Nugget Operating the Terminal in a Network

4

Configuring the DCS 300 The DCS 300 supports and manages communications with other devices in the RF network. When you install and configure the DCS 300, you identify the host computer(s) and T2425s in your network. The terminals communicate through the server with your host by using UDP Plus protocol. For help installing the DCS 300, see the DCS 300 System Manual (Part No. 067296). Note: You can use a T2425 running UDP Plus and the DCS 300 in a pass-through network. You establish a direct TCP/IP socket connection from the T2425 to the host through the server. For more information, see the DCS 300 System Manual. To have the T2425 communicate with the DCS 300, you must configure these parameters on the server: •

Configure the UDP Plus network.

•

Assign an IP address to each T2425.

•

Enable all T2425 terminals.

•

Define the host environment parameters, which includes configuring for terminal emulation, screen mapping, or peer-to-peer applications.

•

Define the host communications parameters, which includes the physical connection (network adapter cards) to the host.

To do screen mapping on the DCS 300, you must also • create the script file using the Script Builder Tool on the server.

• create an application using EZBuilder and download it to the T2425.

Configuring the Access Point The access point acts as a bridge to provide RF communications between the T2425 and the DCS 300 or host. For help, see your access point user’s manual. Note: All access points that the T2425 may communicate with and roam between must be in the same IP subnetwork. To have the T2425 communicate with the access point, you must know the value of these parameters on the access point:

4-19

•

RF domain

•

RF security identification (ID)

Page 232

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de

39 Nugget

Configuring the T2425 When you install the T2425 in a network, you must configure a set of network parameters that control how the terminal communicates in the network. There are two ways to configure the network parameters: •

Use the TRAKKER Antares 2400 Menu System. For help on configuring the network parameters, see Chapter 1, “Getting Started.”

•

Scan the configuration command from a Code 39 or Code 93 bar code label. The configuration commands are listed alphabetically by command name in Chapter 9, “Configuration Command Reference.”

The set of network parameters you must configure depends on whether you install the terminal on the same IP subnetwork as the DCS 300 or host (TCP/IP), or on a different subnetwork. The next table lists the parameters you configure in each type of network:

Network Parameters

Same IP Subnetwork?

Different IP Subnetwork?

Time and date

X

X

Network activate

X

X

Controller IP address (UDP Plus)

X

X

Host IP address (TCP/IP)

X

X

Terminal IP address

X

X

Network port

X

X

RF domain

X

X

Optional

Optional

RF security ID Default router

X

Subnet mask

X

The network parameters are defined in the next section.

Defining the RF Network Parameters This section defines the network parameters you configure when installing the T2425 in an RF network. For each parameter’s syntax and options, see Chapter 9, “Configuration Command Reference.” Time and Date When you turn on the terminal for the first time, you must set the current time and date. You also need to set the time and date any time you lose all power to the terminal. For help, see “Setting the Time and Date” in Chapter 1. Network Activate Disables or enables RF communications. If the Network Activate parameter is disabled, the network is disabled, no RF communications are provided, and the radio is turned off. When the Network Activate parameter is enabled, the T2425 will attempt to connect to the DCS 300 or host.

4-20