The text of a manual · part 28 of 64
Trakker Antares 24XX Terminal User's Manual Addendum, with the Trakker Antares 2420 and 2425 Hand-Held Terminal User's Manual: Chapter 4 - Operating the Terminal in a Network, pages 213 to 222
Pages 213 to 222 of 558, from Trakker Antares 24XX Terminal User's Manual Addendum, with the Trakker Antares 2420 and 2425 Hand-Held Terminal User's Manual
The original document is the PDF (4.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2420 and Intermec 2425
Page 213
4 Operating the Terminal in a Network
Page 214
4-2
Page 215
Co de
39 Nugget Operating the Terminal in a Network
4
This chapter describes a wired network and the Intermec 2.4 GHz RF network and explains how the TRAKKER Antares 2420 and 2425 terminals fit in your network. It also explains how to install and configure the terminal, use serial or RF communications, configure the T2425 over the network, and it provides technical details about network connectivity and protocols.
How the TRAKKER Antares Terminal Fits Into Your Network The TRAKKER Antares 2420 and 2425 terminals are versatile hand-held terminals that you can easily add to your network or distributed data collection system. You can use these terminals as end devices in your wired network. The terminals have a serial port to transmit data to and from a host computer via RS-232 serial communications. You can order the T2420 with a modem that you can use to connect the terminal over a phone line.
TRAKKER Antares Terminals in a Wired Network Mainframe File server
Terminals
Ethernet
PC
242XU.162
TRAKKER Antares Communications dock hardwired to PC
4-3
Page 216
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de
39 Nugget
You can also use the serial port to connect to a 900 MHz RF network via the 9189 RF Gateway. The terminal communicates with the 900 MHz RF network using Polling Mode D protocol.
TRAKKER Antares Terminals in a 900 MHz RF Network Host
DCS 300
RS-485 900 MHz 9181
J2010
9189 J2050 RS-232
242XU.195
T2420
4-4
Page 217
Co de
39 Nugget Operating the Terminal in a Network
4
You can use the T2425s as end devices in your Intermec UDP Plus network. The T2425 communicates with a host computer through the DCS 300 using UDP Plus for the RF protocol. The access point acts as a bridge to allow communications between the Ethernet or token ring network and the T2425s.
T2425s in a UDP Plus Network Host
TRAKKER Antares 2425 terminals
Access point
Ethernet 242XU.095
DCS 300
4-5
Page 218
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de
39 Nugget
You can use the T2425s as end devices in your Intermec TCP/IP network. The T2425 communicates with a host computer directly using TCP/IP for the RF protocol. The access point acts as a bridge to allow communications between the Ethernet or token ring network and the T2425s.
T2425s in a TCP/IP Direct Connect Network Host
TRAKKER Antares 2425 terminals
Access point
Ethernet 242XU.190
4-6
Page 219
Co de
39 Nugget Operating the Terminal in a Network
4
You can install the T2425s, access points, and DCS 300 in your Intermec UDP Plus network as shown in the next illustration. The T2425s may only communicate with the access points that are in the same IP subnetwork. All the terminals and access points in this illustration communicate with the DCS 300 at IP address 192.9.175.7 using UDP Plus for the RF protocol.
Installing T2425s in Multiple Subnetworks (UDP Plus) DCS 300 192.9.175.7
Router
Access point
TRAKKER Antares 2425 terminals 192.9.200.5, 192.9.200.6
4-7
Ethernet
T2425's cannot roam between subnetworks
192.9.200.X subnetwork
Access point
192.9.175.X subnetwork
Access point
TRAKKER Antares 2425 terminals 192.9.175.10 192.9.175.11 192.9.175.12
242XU.091
Page 220
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de
39 Nugget
You can install the T2425s and access points in your Intermec TCP/IP network as shown in the illustration below. The T2425s may only communicate with the access points that are in the same IP subnetwork. All the terminals and access points in this illustration communicate with the host at IP address 192.9.175.7 using TCP/IP for the RF protocol.
Installing T2425s in Multiple Subnetworks (TCP/IP) Host
192.9.175.7
Router
Access point
TRAKKER Antares 2425 terminals 192.9.200.5, 192.9.200.6
4-8
Ethernet
T2425's cannot roam between subnetworks
192.9.200.X subnetwork
Access point
192.9.175.X subnetwork
Access point
TRAKKER Antares 2425 terminals 192.9.175.10 192.9.175.11 192.9.175.12
242XU.169
Page 221
Co de
4
39 Nugget Operating the Terminal in a Network
You can install the T2425s and access points in one IP subnetwork and install the DCS 300 in another IP subnetwork as shown in the illustration below. In this network, you must configure additional network parameters (default router and subnet mask) as described later in this chapter. Note: All access points that the T2425 may communicate with and roam between must be on the same IP subnetwork. The terminal cannot roam between IP subnetworks.
T2425s Communicating Across Subnetworks (UDP Plus) DCS 300 192.9.200.5
192.9.200.X subnetwork
Router
192.9.175.X subnetwork Ethernet
192.9.175.1
Access point
TRAKKER Antares 2425 terminals 192.9.175.9 192.9.175.10 192.9.175.11
242XU.092
4-9
Page 222
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de
39 Nugget
Using Serial Communications on the Terminals The terminals have a serial port to transfer data to and from another device via RS-232 serial communications. You can order the T2420 with a modem that you can use to connect the terminal over a phone line. Before you can use the serial port, you need to connect and configure the terminal. The next sections cover these topics: •
Identifying the COM Ports
•
Connecting the Terminal to Another Device
•
Choosing a Communications Protocol
•
Configuring the Serial Port Parameters
•
Configuring the Terminal Via the Serial Port
Identifying the COM Ports Communications ports, also called COM ports, are locations from which data can be passed into and out of the terminal. This illustration identifies the COM ports on the T2420 and the T2425. For help on the COM1 pin assignments, see “Pin Assignments for COM1” in Appendix A.
T2425
ES
R
T
R
A
K
K
E
R
AN
TA
24
25
COM 4 serial port ES
R
K
K
E
R
AN
TA
24
20
T2420 T
R
A
COM 4 serial port
F5
9
I/O
F4
6
F3
8
F2
1
0
4
2
7
5
3
F1 ter
F5
E
En Fn
9
I/O
F4 F3
6
Fn
L
J
D
R C
O
I
T
N
H
B
8
F2
A
Y
S
M
G
5
3
F1
L
7
F
2 4
P c
Es
W
Q
K
X
R b
Ta
0
V
1
U ter
E
En Fn Fn G
L
Z J
D
R C
O
I
X
R
P c
Es
W
Q
K
Y
S
M L
F
T
N
H
B A
V b
Ta
U Z
242XU.183
COM 3 serial port
4-10
COM1 serial port
Port
COM Port Designation for Applications
COM1
Use for serial port communications on the terminal.
COM3
Use for modem communications on the T2420
COM4
Use for serial port communications with a PC or printer.
RF (NET)
Use for RF communications on the T2425. The TRAKKER Antares PSK functions use NET to designate the RF network port.