Bar Code Symbologies Table (continued) Parameter (Syntax)
Options
Location in Configuration Menu
Code 49 (continued) • Function Code 2 (CL)
\x0D\x0A (CR LF) Any four ASCII characters
• Function Code 3 (CM)
None (disabled) Any two ASCII characters
Code 93 (CF)
Disabled Enabled
Symbologies Menu, Code 93 option
Code 128 (CH)
Disabled Standard UCC/EAN-128 ISBT
Symbologies Menu, Code 128 option
• ISBT symbology
Disabled Enabled
• ISBT concatenated
Disabled Enabled
Interleaved 2 of 5 (CA)
Disabled Fixed length Variable length, no check digit Case Code, check digit Variable length, check digit
Symbologies Menu, 2 of 5, I2 of 5 option
MSI (CN)
Disabled No check digit 1 modulus 10 check digits 2 modulus 10 check digits
Symbologies Menu, MSI option
• Check digits
Discard Retain
Symbologies Menu, MSI option
Plessey (CI)
Disabled Discard check digit Retain check digit
Symbologies Menu, Plessey option Symbologies Menu, UPC/EAN option
UPC/EAN (CE) • UPC-A/EAN-13 (Version A)
Disabled Enabled UPC-A only
• UPC-E (Version E)
Disabled Enabled
• EAN-8
Disabled Enabled
• Supplementals
Yes No
3-25
Page 206
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual
Bar Code Symbologies Table (continued) Parameter (Syntax) UPC/EAN (continued) • Check digit
Options
Location in Configuration Menu
Discard Retain
• Number system digit
Discard Retain
• UPC-A leading zero
Discard Retain
RF Network Communications Table (T2425 Only) Note: The RF network parameters are different for each type of RF network protocol, TCP/IP or UDP Plus, loaded on the terminal. Parameter (Syntax)
Options
Location in Configuration Menu
Acknowledgement Delay Lower Limit (NV)
300 milliseconds 200 - 2000 milliseconds
Communications Menu, Advanced Network option
Acknowledgement Delay Upper Limit (NU)
5000 milliseconds 2000 - 60000 milliseconds
Communications Menu, Advanced Network option
Controller Connect Check Receive Timer (NP)
60 seconds 1 - 3600 seconds
Communications Menu, Advanced Network option
Controller Connect Check Send Timer (NQ)
35 seconds 1 - 3600 seconds
Communications Menu, Advanced Network option
Controller IP Address (NC)
0.0.0.0 The IP address field is four numbers separated by periods.
Communications Menu, Primary Network option
Default Router (NX)
0.0.0.0 (no default router) The Router field is four numbers separated by periods.
Communications Menu, Advanced Network option
Host IP Address (NC)
0.0.0.0 The IP address field is four numbers separated by periods.
Communications Menu, Primary Network option
Maximum Retries (NR)
7 0 – 99
Communications Menu, Advanced Network option
Network Activate (NA)
Disabled 2.4 GHz RF
Communications Menu, Primary Network option
3-26
Page 207
Configuring the Terminal
3
RF Network Communications Table (T2425 Only) (continued) Parameter (Syntax)
Options
Location in Configuration Menu
Network Loopback (NL)
Disabled Enabled
Communications Menu, Advanced Network option
Network Port (NG)
00023 (for TCP/IP) 05555 (for UDP Plus) 1 – 65535
Communications Menu, Advanced Network option
RF Domain (RW)
0 0 – 15
Communications Menu, Radio option
RF Inactivity Timeout (RY)
5 seconds 0 - 255 seconds
Communications Menu, Radio option
RF Roaming Flag (RR)
Allowed Not allowed
Communications Menu, Radio option
RF Security ID (RS)
None (no characters) Any 20 ASCII characters
Communications Menu, Radio option
RF Transmit Mode (RT)
BFSK QFSK Auto
Communications Menu, Radio option
RF Wakeup On Broadcast (RB)
No Yes
Communications Menu, Radio option
Subnet Mask (NS)
255.255.255.0 The Subnet Mask field is four numbers separated by periods.
Communications Menu, Advanced Network option
TCP/IP Maximum Transmit Timeout (NH)
0 (No timeout) 0 - 128 seconds 20 seconds
Communications Menu, Advanced Network option
Terminal IP Address (ND)
0.0.0.0 The IP address field is four numbers separated by periods.
Communications Menu, Primary Network option
3-27
Page 208
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual
Serial Network Communications Table Parameter (Syntax)
Options
Location in Configuration Menu
Baud Rate (YA)
1200 2400 4800 9600 19200 38400
Communications Menu, Serial Port option
Configuration Commands Via Serial Port (YT)
Disabled Enabled with TMF Enabled without TMF
Communications Menu, Serial Port option
Data Bits (YI)
7 8
Communications Menu, Serial Port option
EOM (YZ)
\x03 (ETX) Any two ASCII characters
Communications Menu, Serial Port option
Flow Control (YL)
None CTS checking XON/XOFF response XON/XOFF control XON/XOFF response & control CTS/RTS on DTE/DTE
Communications Menu, Serial Port option
Handshake (YJ)
Disabled Enabled
Communications Menu, Serial Port option
LRC (YF)
Disabled Enabled
Communications Menu, Serial Port option
Parity (YB)
None Even Odd
Communications Menu, Serial Port option
Poll (YR)
Disabled Enabled
Communications Menu, Serial Port option
Protocol (YU)
Configurable Polling Mode D Master Polling Binary
Communications Menu, Serial Port option
SOM (YY)
\x02 (STX) Any ASCII character
Communications Menu, Serial Port option
Stop Bits (YC)
1 2
Communications Menu, Serial Port option
3-28
Page 209
Configuring the Terminal
3
Serial Network Communications Table (continued) Parameter (Syntax)
Options
Location in Configuration Menu
Timeout Delay (YE)
5 milliseconds 100 milliseconds 500 milliseconds 2 seconds 10 seconds 20 seconds 40 seconds 60 seconds
Communications Menu, Serial Port option
Parameter (Syntax)
Options
Location in Configuration Menu
Append Time (DE)
Disabled Enabled
Terminal Menu, Append Time option
Automatic Shutoff (EZ)
0 (disabled) 2 - 75 minutes
Terminal Menu, Power Management option
Beep Volume (BV)
Off Quiet Normal Loud Very loud
Terminal Menu, Beeper option
Decode Security (CS)
Low Moderate High
Terminal Menu, Scanner option
Display Backlight Timeout (DF)
0 (disabled) 10 seconds 0 – 60 seconds
Terminal Menu, Display option
Display Contrast (DJ)
3 0–7
Terminal Menu, Display option
Display Font Type (DT)
8x8 8x16 16x16
Terminal Menu, Display option
Display Row Spacing (DL)
0 (one scan line) 0–8
Terminal Menu, Display option
Display Video Mode (DN)
0 (original) 0–2
Terminal Menu, Display option
Keypad Caps Lock (KA)
On Off
Terminal Menu, Keypad option
Terminal Operations Table
3-29
Page 210
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual
Terminal Operations Table Parameter (Syntax)
Options
Location in Configuration Menu
Keypad Clicker (KC)
Disabled Enabled
Terminal Menu, Keypad option
Keypad Type (KT)
Hardware default Terminal emulation Programmable
Terminal Menu, Keypad option
Postamble (AE)
None (no characters) Any 25 ASCII characters
Terminal Menu, Preamble/Postamble option
Preamble (AD)
None (no characters) Any 25 ASCII characters
Terminal Menu, Preamble/Postamble option
RAM Drive Size (FR)
0 (disabled) 16 - 256K
Terminal Menu, RAM Drive option
Reader Commands (DC)
Disable all reader commands Enable all reader commands Enable specific reader commands Override reader commands
Terminal Menu, Reader Commands option
• Enable/Disable specific reader commands
Abort Program Backlight Backspace Change Configuration Clear Default Configuration Delete File Enter Accumulate mode Exit Accumulate mode List Files Multiple-Read Labels Receive File Rename File Reset Run Program Scanner Trigger Off Scanner Trigger On Test & Service mode Transmit File
Terminal Menu, Reader Commands option, Enable single commands option
• Override specific reader commands that are disabled
No Yes
Terminal Menu, Reader Commands option, Override reader commands option
Resume Execution (ER)
Not Allowed Allowed
Terminal Menu, Power Management option
Scan Ahead (SD)
Disabled Enabled
Terminal Menu, Scanner option
3-30
Page 211
Configuring the Terminal
3
Terminal Operations Table (continued) Parameter (Syntax)
Options
Location in Configuration Menu
Scanner Mode (SB)
One-Shot mode Automatic mode
Terminal Menu, Scanner option
Scanner Redundancy (SR)
None Normal High
Terminal Menu, Scanner option
Scanner Selection (SS) (See the Note)
All compatible scanners 146X CCD scanners 151X laser scanners 1545 laser scanner Symbol scanners 155X laser scanners Tethered Long Range Intg. Long Range No Aim Intg. Long Range Short Aim Intg. Long Range Long Aim
Terminal Menu, Scanner option
Scanner Timeout (SA)
0 (disabled) 0 – 60 seconds
Terminal Menu, Scanner option
Scanner Trigger (SC)
Level Edge
Terminal Menu, Scanner option
Time in Seconds (DA)
Disabled Enabled
Terminal Menu, Append Time option
Note: The Scanner Selection command is only used when you have a module for cabled scanners, a long range scan module, or a high density scan module installed.
3-31
Page 212
3-32