Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 26 of 64

Trakker Antares 24XX Terminal User's Manual Addendum, with the Trakker Antares 2420 and 2425 Hand-Held Terminal User's Manual: Chapter 3 - Configuring the Terminal, pages 197 to 204

Pages 197 to 204 of 558, from Trakker Antares 24XX Terminal User's Manual Addendum, with the Trakker Antares 2420 and 2425 Hand-Held Terminal User's Manual

The original document is the PDF (4.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 2420 and Intermec 2425

Page 197

Configuring the Terminal

3

Saving Configuration Changes in Flash Memory The terminals use two copies of the configuration: Runtime or RAM configuration is the current or active set of parameters and options enabled on the terminal. The configuration is stored in RAM and will be lost if you boot or reset the terminal. Boot or flash configuration is the set of parameters and options last saved in flash memory. The configuration is stored in flash memory and will be saved and used if you boot or reset the terminal. Here are the four ways you can configure the terminal and how the configuration is updated: Runtime or RAM Configuration Updated?

Boot or Flash Configuration Updated?

Using the TRAKKER Antares 2400 Menu System

Yes (see Note)

Yes (see Note)

Scanning bar code labels

Yes

No

From a host application through the serial port

Yes

No

T2425 from the network (DCS 300 or host)

Yes

No

Configure the Terminal

Note: You are prompted to save your changes in RAM and flash as you exit the Configuration Menu and the TRAKKER Antares 2400 Menu System. Your changes are saved if you choose Yes at each screen. If you configure the terminal by scanning bar code labels, through the serial port, or from the network, you may want to save the changes in flash memory using one of these methods: •

Scan or send the Save Configuration in Flash Memory reader command.

•

Use the TRAKKER Antares 2400 Menu System.

To save configuration changes using the reader command •

Scan this bar code label: Save Configuration in Flash Memory

*.+1* *.+1*

Or, send the command .+1 as the last command from the controller or host application. For help, see Chapter 4, “Operating the Terminal in a Network.”

3-17

Page 198

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual

To save configuration changes using the menu system 1. Press

T 3 , or scan this bar code. The Main Menu appears.

Enter Test and Service Mode

*..-.* *..-.*

2. Choose System Menu and press SYSTEM

The System Menu appears.

MENU

File Manager Load Default Values Set Time and Date Store Configuration Upgrade Firmware

_` Select item [Enter] Next screen [F1] Help [Esc] Exit 242XU.051

3. Choose the Store Configuration command and press screen appears.

The Store Configuration

STORE CONFIGURATION Store Configuration in Flash Memory

OK

CANCEL 242XU.072

4. Choose OK to save the configuration in flash memory. To exit without saving the configuration, choose Cancel. The System Menu appears.

? to exit the System Menu. The Main Menu appears. 6. Choose another menu from the Main Menu or press ? to exit the TRAKKER 5. Press

Antares 2400 Menu System.

3-18

Page 199

Configuring the Terminal

3

Restoring the Terminal’s Default Configuration When you configure the terminal according to the instructions presented in this chapter, the parameters remain in effect until you reconfigure them. If you configure the terminal but do not save your changes in flash memory, the parameters will remain in effect until you boot or reset the terminal. The default configuration for the terminal is listed in Appendix A. You can use the TRAKKER Antares 2400 Menu System or scan the Default Configuration bar code label to return the terminal to its default configuration. Note: If you restore the default configuration, you need to set the primary network communications parameters on the T2425 to reestablish communications with other devices in the 2.4 GHz RF network. You may also need to reset the serial port parameters to communicate with another device through the serial port. To restore the default configuration using the reader command •

Scan this bar code label: Default Configuration

*.+0* *.+0*

To restore the default configuration using the menu system 1. Press

T 3 , or scan this bar code:

Enter Test and Service Mode

*..-.* *..-.*

The Main Menu appears. 2. Choose System Menu and press

The System Menu appears.

3-19

Page 200

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual

3. Choose the Load Default Values command and press screen appears. LOAD

DEFAULT

The Load Default Values

VALUES

Load default configuration values in RAM? (Overwrites current configuration)

OK

CANCEL 242XU.056

4. Choose OK and press to load the default configuration values. The default values will override the current runtime configuration on the terminal. To exit without loading the default values, choose Cancel and press Menu appears.

The System

? to exit the System Menu. The Main Menu appears. 6. Choose another menu from the Main Menu or press ? to exit the TRAKKER 5. Press

Antares 2400 Menu System. For help exiting the menu system, see “Exiting the TRAKKER Antares 2400 Menu System” earlier in this chapter.

3-20

Page 201

Configuring the Terminal

3

Upgrading the Firmware The terminal firmware includes these items: •

TRAKKER Antares 2400 Menu System

•

Terminal emulation or sample application

•

TE Configuration Menu (3270, 5250, VT/ANSI terminals only)

•

Operating environment, firmware, and drivers

You can upgrade a terminal to use the latest firmware version (2.x or higher) without making any hardware changes. There are two upgrade kits: Firmware Upgrade Kit

Part Number

Description

TRAKKER Antares TCP/IP

066814S

Order this kit for terminals that communicate in a TCP/IP direct connect network or a TCP/IP pass-through network.

TRAKKER Antares UDP Plus

067119S

Order this kit for terminals that communicate with a DCS 300 in a UDP Plus network.

You can order either kit for the T2420. To order a firmware upgrade kit, contact your local Intermec service representative. Each kit comes with a utility and instructions to upgrade the firmware on the terminal. Once you upgrade to the new firmware, you can use all the features described in this manual. Each kit comes with the new firmware version, the applications, the firmware upgrade utilities (DOS and Windows), and instructions about upgrading the terminal firmware. You can upgrade the firmware on the T2420 or the T2425 from a host computer or PC using serial communications. You connect the terminal’s serial port to the host or PC by using one of these accessories: •

Communications dock

•

Optical link adapter

•

Serial interface module

For help connecting the terminal, see “Using Serial Communications on the Terminals” in Chapter 4. Once the terminal is connected, you can upgrade the firmware. Note: You can also upgrade the firmware on one or more terminals using the Firmware Upgrade Utility on the DCS 300. For help, see the DCS 300 System Manual.

3-21

Page 202

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual

To upgrade the firmware with the Windows utility 1. Connect the terminal to your PC. 2. From Program Manager, start the TRAKKER Antares Firmware Installation utility. The Firmware Installation utility screen appears. The Firmware Installation utility includes detailed online help. You click the Help button anytime to get more information. 3. Choose the COM port and the Firmware Type (application). For example, the T2420 sample application is one firmware type. 4. On the terminal, press

T 3 , or scan this bar code label:

Enter Test and Service Mode

*..-.* *..-.*

The Main Menu appears. 5. Choose System Menu and press SYSTEM

The System Menu appears.

MENU

File Manager Load Default Values Set Time and Date Store Configuration Upgrade Firmware

_` Select item [Enter] Next screen [F1] Help [Esc] Exit 242XU.051

3-22

Page 203

Configuring the Terminal

6. Choose Upgrade Firmware and press

UPGRADE

3

The Upgrade Firmware screen appears.

FIRMWARE

Upgrade terminal firmware? Make sure the terminal is connected to a host computer through the optical adapter.

OK

CANCEL 242XU.074

7. Choose OK to continue. The next screen appears.

Are you want to sure you continue?

Selecting YES will upgrade and replace all of the terminal's firmware. Selecting NO will exit without upgrading firmware.

YES

NO 242XU.152

8. Choose Yes to continue and upgrade the firmware. The terminal reboots and then displays the Loader Waiting screen. To exit without upgrading the firmware, choose No.

? L !

Note: If you reach the Loader Waiting screen and cannot upgrade or continue, press or to exit without upgrading the firmware. The Boot Menu appears. Press to boot the terminal and continue. 9. On your PC, make sure you selected the COM port and Firmware Type, and then choose OK. The PC downloads the firmware and application. Once the download is complete, the terminal boots and runs the application. Repeat these instructions to upgrade the firmware on another terminal. For help with the TRAKKER Antares firmware installation utilities, see the README.TXT instructions that ship with the utility or use the online help.

3-23

Page 204

TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual

Recording Your Terminal’s Configuration The tables in this section list all the configuration parameters, their options, and where to find them in the Configuration Menu of the TRAKKER Antares 2400 Menu System. The default setting for each parameter is shown in bold italics. You should have an accurate record of the terminal’s configuration settings in case the terminal’s volatile memory and the configuration setup are lost. Record the configuration on these pages by circling the option you chose for each parameter or writing the value.

Bar Code Symbologies Table Parameter (Syntax)

Options

Location in Configuration Menu

Codabar (CD)

Disabled ABC Standard Concatenated

Symbologies Menu, Codabar option

• Start/Stop digit

Discard Retain ABCD Retain DC1-DC4

Code 11 (CG)

Disabled One check digit Two check digits

Symbologies Menu, Code 11 option

Code 16K (CP)

Disabled Standard Function code 1

Symbologies Menu, Code 16K option

Code 2 of 5 (CC)

Disabled 3 bar start/stop, label length 2 bar start/stop, label length

Symbologies Menu, 2 of 5, I2 of 5 option

Code 39 (CB)

Disabled No check digit Check digit HIBC AIAG check digit

Symbologies Menu, Code 39 option

• Check digit

Discard Retain

• ASCII

Non-full Full Mixed-full

Symbologies Menu, Code 39 option

Code 49 (CJ)

Disabled Enabled

Symbologies Menu, Code 49 option

• Function Code 1 (CK) None (disabled) Any two ASCII characters

3-24