Page 197
Configuring the Terminal
3
Saving Configuration Changes in Flash Memory The terminals use two copies of the configuration: Runtime or RAM configuration is the current or active set of parameters and options enabled on the terminal. The configuration is stored in RAM and will be lost if you boot or reset the terminal. Boot or flash configuration is the set of parameters and options last saved in flash memory. The configuration is stored in flash memory and will be saved and used if you boot or reset the terminal. Here are the four ways you can configure the terminal and how the configuration is updated: Runtime or RAM Configuration Updated?
Boot or Flash Configuration Updated?
Using the TRAKKER Antares 2400 Menu System
Yes (see Note)
Yes (see Note)
Scanning bar code labels
Yes
No
From a host application through the serial port
Yes
No
T2425 from the network (DCS 300 or host)
Yes
No
Configure the Terminal
Note: You are prompted to save your changes in RAM and flash as you exit the Configuration Menu and the TRAKKER Antares 2400 Menu System. Your changes are saved if you choose Yes at each screen. If you configure the terminal by scanning bar code labels, through the serial port, or from the network, you may want to save the changes in flash memory using one of these methods: •
Scan or send the Save Configuration in Flash Memory reader command.
•
Use the TRAKKER Antares 2400 Menu System.
To save configuration changes using the reader command •
Scan this bar code label: Save Configuration in Flash Memory
*.+1* *.+1*
Or, send the command .+1 as the last command from the controller or host application. For help, see Chapter 4, “Operating the Terminal in a Network.”
3-17
Page 198
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual
To save configuration changes using the menu system 1. Press
T 3 , or scan this bar code. The Main Menu appears.
Enter Test and Service Mode
*..-.* *..-.*
2. Choose System Menu and press SYSTEM
The System Menu appears.
MENU
File Manager Load Default Values Set Time and Date Store Configuration Upgrade Firmware
_` Select item [Enter] Next screen [F1] Help [Esc] Exit 242XU.051
3. Choose the Store Configuration command and press screen appears.
The Store Configuration
STORE CONFIGURATION Store Configuration in Flash Memory
OK
CANCEL 242XU.072
4. Choose OK to save the configuration in flash memory. To exit without saving the configuration, choose Cancel. The System Menu appears.
? to exit the System Menu. The Main Menu appears. 6. Choose another menu from the Main Menu or press ? to exit the TRAKKER 5. Press
Antares 2400 Menu System.
3-18
Page 199
Configuring the Terminal
3
Restoring the Terminal’s Default Configuration When you configure the terminal according to the instructions presented in this chapter, the parameters remain in effect until you reconfigure them. If you configure the terminal but do not save your changes in flash memory, the parameters will remain in effect until you boot or reset the terminal. The default configuration for the terminal is listed in Appendix A. You can use the TRAKKER Antares 2400 Menu System or scan the Default Configuration bar code label to return the terminal to its default configuration. Note: If you restore the default configuration, you need to set the primary network communications parameters on the T2425 to reestablish communications with other devices in the 2.4 GHz RF network. You may also need to reset the serial port parameters to communicate with another device through the serial port. To restore the default configuration using the reader command •
Scan this bar code label: Default Configuration
*.+0* *.+0*
To restore the default configuration using the menu system 1. Press
T 3 , or scan this bar code:
Enter Test and Service Mode
*..-.* *..-.*
The Main Menu appears. 2. Choose System Menu and press
The System Menu appears.
3-19
Page 200
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual
3. Choose the Load Default Values command and press screen appears. LOAD
DEFAULT
The Load Default Values
VALUES
Load default configuration values in RAM? (Overwrites current configuration)
OK
CANCEL 242XU.056
4. Choose OK and press to load the default configuration values. The default values will override the current runtime configuration on the terminal. To exit without loading the default values, choose Cancel and press Menu appears.
The System
? to exit the System Menu. The Main Menu appears. 6. Choose another menu from the Main Menu or press ? to exit the TRAKKER 5. Press
Antares 2400 Menu System. For help exiting the menu system, see “Exiting the TRAKKER Antares 2400 Menu System” earlier in this chapter.
3-20
Page 201
Configuring the Terminal
3
Upgrading the Firmware The terminal firmware includes these items: •
TRAKKER Antares 2400 Menu System
•
Terminal emulation or sample application
•
TE Configuration Menu (3270, 5250, VT/ANSI terminals only)
•
Operating environment, firmware, and drivers
You can upgrade a terminal to use the latest firmware version (2.x or higher) without making any hardware changes. There are two upgrade kits: Firmware Upgrade Kit
Part Number
Description
TRAKKER Antares TCP/IP
066814S
Order this kit for terminals that communicate in a TCP/IP direct connect network or a TCP/IP pass-through network.
TRAKKER Antares UDP Plus
067119S
Order this kit for terminals that communicate with a DCS 300 in a UDP Plus network.
You can order either kit for the T2420. To order a firmware upgrade kit, contact your local Intermec service representative. Each kit comes with a utility and instructions to upgrade the firmware on the terminal. Once you upgrade to the new firmware, you can use all the features described in this manual. Each kit comes with the new firmware version, the applications, the firmware upgrade utilities (DOS and Windows), and instructions about upgrading the terminal firmware. You can upgrade the firmware on the T2420 or the T2425 from a host computer or PC using serial communications. You connect the terminal’s serial port to the host or PC by using one of these accessories: •
Communications dock
•
Optical link adapter
•
Serial interface module
For help connecting the terminal, see “Using Serial Communications on the Terminals” in Chapter 4. Once the terminal is connected, you can upgrade the firmware. Note: You can also upgrade the firmware on one or more terminals using the Firmware Upgrade Utility on the DCS 300. For help, see the DCS 300 System Manual.
3-21
Page 202
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual
To upgrade the firmware with the Windows utility 1. Connect the terminal to your PC. 2. From Program Manager, start the TRAKKER Antares Firmware Installation utility. The Firmware Installation utility screen appears. The Firmware Installation utility includes detailed online help. You click the Help button anytime to get more information. 3. Choose the COM port and the Firmware Type (application). For example, the T2420 sample application is one firmware type. 4. On the terminal, press
T 3 , or scan this bar code label:
Enter Test and Service Mode
*..-.* *..-.*
The Main Menu appears. 5. Choose System Menu and press SYSTEM
The System Menu appears.
MENU
File Manager Load Default Values Set Time and Date Store Configuration Upgrade Firmware
_` Select item [Enter] Next screen [F1] Help [Esc] Exit 242XU.051
3-22
Page 203
Configuring the Terminal
6. Choose Upgrade Firmware and press
UPGRADE
3
The Upgrade Firmware screen appears.
FIRMWARE
Upgrade terminal firmware? Make sure the terminal is connected to a host computer through the optical adapter.
OK
CANCEL 242XU.074
7. Choose OK to continue. The next screen appears.
Are you want to sure you continue?
Selecting YES will upgrade and replace all of the terminal's firmware. Selecting NO will exit without upgrading firmware.
YES
NO 242XU.152
8. Choose Yes to continue and upgrade the firmware. The terminal reboots and then displays the Loader Waiting screen. To exit without upgrading the firmware, choose No.
? L !
Note: If you reach the Loader Waiting screen and cannot upgrade or continue, press or to exit without upgrading the firmware. The Boot Menu appears. Press to boot the terminal and continue. 9. On your PC, make sure you selected the COM port and Firmware Type, and then choose OK. The PC downloads the firmware and application. Once the download is complete, the terminal boots and runs the application. Repeat these instructions to upgrade the firmware on another terminal. For help with the TRAKKER Antares firmware installation utilities, see the README.TXT instructions that ship with the utility or use the online help.
3-23
Page 204
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual
Recording Your Terminal’s Configuration The tables in this section list all the configuration parameters, their options, and where to find them in the Configuration Menu of the TRAKKER Antares 2400 Menu System. The default setting for each parameter is shown in bold italics. You should have an accurate record of the terminal’s configuration settings in case the terminal’s volatile memory and the configuration setup are lost. Record the configuration on these pages by circling the option you chose for each parameter or writing the value.
Bar Code Symbologies Table Parameter (Syntax)
Options
Location in Configuration Menu
Codabar (CD)
Disabled ABC Standard Concatenated
Symbologies Menu, Codabar option
• Start/Stop digit
Discard Retain ABCD Retain DC1-DC4
Code 11 (CG)
Disabled One check digit Two check digits
Symbologies Menu, Code 11 option
Code 16K (CP)
Disabled Standard Function code 1
Symbologies Menu, Code 16K option
Code 2 of 5 (CC)
Disabled 3 bar start/stop, label length 2 bar start/stop, label length
Symbologies Menu, 2 of 5, I2 of 5 option
Code 39 (CB)
Disabled No check digit Check digit HIBC AIAG check digit
Symbologies Menu, Code 39 option
• Check digit
Discard Retain
• ASCII
Non-full Full Mixed-full
Symbologies Menu, Code 39 option
Code 49 (CJ)
Disabled Enabled
Symbologies Menu, Code 49 option
• Function Code 1 (CK) None (disabled) Any two ASCII characters
3-24