Page 233
Co de
39 Nugget Operating the Terminal in a Network
4
Controller IP Address An IP address is a unique network level address you assign to each device in a TCP/IP network. The Controller IP Address identifies the IP address assigned to the DCS 300 in a UDP Plus network. Host IP Address An IP address is a unique network level address you assign to each device in a TCP/IP direct connect network. The Host IP Address identifies the IP address assigned to the host. Terminal IP Address An IP address is a unique network level address you assign to each device in a TCP/IP network. The Terminal IP Address identifies the IP address assigned to the T2425. The IP address you set on the terminal must match the address that is set for the terminal on the DCS 300 or host. Network Port Defines the network port that the TCP/IP or UDP Plus network protocol uses for communications in your RF network. In a UDP Plus network, the network port you set on the T2425 must match the network port that is set on the DCS 300. In a TCP/IP network, set the network port to the appropriate port for the application you are using on the T2425. The default network port of 23 enables VT/ANSI Telnet communications. RF Domain The domain defines a logical partition or subnetwork of the network. To establish communications, you must assign the same domain number to every RF device in a wireless network. The domain number you set on the terminal must match the domain that is set on each access point the terminal may communicate with. You can continue to collect data with the terminal as you roam between access points as long as all the devices have the same domain number. RF Security Identification (ID) This parameter defines the password you can set for secured transmission and receipt of data between devices in the wireless network. If the security ID is set on the access point, you must also set the security ID on each T2425 that may communicate with the access point. To communicate, each access point and terminal must have matching security IDs. Note: The Network Activate command must be configured to 2.4 GHz RF network before you can save any changes to the RF security ID parameter. Default Router Provides a software and hardware connection between two or more networks that permits traffic to be routed from one network to another on the basis of the intended destinations of that traffic. When the DCS 300 (UDP Plus) or host (TCP/IP) is on a different subnetwork than the T2425, you need to set the default router IP address. The terminal uses the router address to send packets across the network to the DCS 300 or host. The default router must have an IP address on the same subnetwork as the terminal. The default of 0.0.0.0 means there is no default router. Subnet Mask The subnet mask is an internal TCP/IP protocol stack variable that is used in IP protocol to identify the subnetwork for an IP address. The IP protocol performs a bit-wise AND on the IP address and the subnet mask. Each address segment represents one byte, where 255 converts to FF hex. This computation is used to find out if the DCS 300 (UDP Plus) or host (TCP/IP) and terminal are on different subnetworks.
4-21
Page 234
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de
39 Nugget
If the terminal is on a different IP subnetwork than the DCS 300 or host, then you must set the subnet mask and default router.
Using the Icons to Monitor RF Communications Once you have configured the devices in the RF network, you can begin using the application on the T2425 to collect and transmit data via RF communications. If the T2425 is communicating with your host computer, the terminal will connect and begin running the application that shipped on the terminal. As you use the T2425 to collect data, icons are displayed to help you monitor RF and network communications on the terminal. Use the two icons shown in the illustration to monitor communications between the T2425 and other devices in the RF network.
*• Sign on User.............. Password.......... Program/procedure. Menu.............. Current Library...
TNAPP
F 242XU.093
You See These Icons
Status of Communications
What You Need to Do
No communications.
You need to enable the Network Activate command. For help, see “Network Activate” in Chapter 9.
The Radio icon remains on.
The T2425 is not connected to an access point. The Network Activate command is disabled, or there is a problem with the radio card and it is turned off.
No icons appear.
No communications. The T2425 is not connected to an access point.
Make sure the access points are turned on and operating. You may also be using the terminal out of the RF range of an access point. Try moving closer to an access point to re-establish communications. If the access point is on and you are in range, you may need to configure the terminal to communicate in the network. For help, see “Configuring the T2425” earlier in this chapter.
4-22
Page 235
Co de
39 Nugget Operating the Terminal in a Network
4
Using the Icons to Monitor RF Communications (continued) You See These Icons
* The Connect icon blinks.
Status of Communications
What You Need to Do
Partial communications.
You may need to configure the T2425 to communicate with other devices in the RF network. For help, see “Configuring the T2425” earlier in this chapter.
The T2425 is trying to establish communications with the DCS 300 (UDP Plus) or is trying to connect to an access point.
If the T2425 is configured, you may be out of range of an access point, you may be about to go out of range of an access point, or the access point may have recently been turned off. You may need to configure the DCS 300 (UDP Plus) or host. Make sure the T2425 is configured correctly and enabled. Make sure the DCS 300 is turned on and data collection is started.
*
Normal communications.
The Connect icon remains on.
The T2425 can communicate with an access point and the DCS 300 (UDP Plus) or host.
*• The Connect icon remains on, and the Data icon blinks.
*• The Connect icon and Data icon remain on.
4-23
Normal communications. The T2425 is sending data to or receiving data from the DCS 300 or host.
Normal communications. The T2425 has received data for an application from the DCS 300 or host. The data is stored in the terminal’s radio buffer until the application is ready to process the data.
You can send and receive data between the T2425 and the access point.
You can send and receive data between the T2425 and the DCS 300 or host. Note: You may not see the Data icon blink if communications are occurring instantaneously. You can send and receive data between the T2425 and the DCS 300 or host.
Page 236
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de
39 Nugget
Using the T2425 Between Access Points The access point acts as a bridge to provide communications between the T2425 and the Ethernet or token ring network. You may have multiple access points in your RF network to provide uninterrupted wireless communication at any location within your facility. To use the T2425 between access points and continue sending and receiving data, you must follow these guidelines: •
The radio coverage of each access point must overlap to ensure that the roaming T2425 will always have a connection available.
•
You configure each access point with the same RF domain number and security ID.
•
You configure the T2425s with the same RF domain and security ID as the access points to which they may communicate.
•
All access points that the T2425s may communicate with and roam between must be installed in the same IP subnetwork. The T2425 cannot roam between IP subnetworks.
Once the network is configured, you can collect data anywhere within range of the access points in the RF network. When you move out of range of one access point, the T2425 automatically polls the other access points in the same RF domain to continue the network connection. If you are out of range of all access points in the network, the data is stored in the T2425’s radio buffer. The Data icon appears on the screen and the Connect icon starts flashing or turns off. You can continue to collect data until the radio buffer is full. When the buffer is full, the application displays a communication timeout status. When you move back into range and network communications are re-established, the data in the radio buffer is transmitted to the access point and you can once again transmit data. In a TCP/IP direct connect network with a T2425 running a terminal emulation application, the application may disconnect from the host if you remain out of communications range too long or if the host sends “Keep Alive” messages while the terminal is in Suspend mode. You may need to restart the application and log back into the host to re-establish a terminal emulation session. For help, see Chapter 6, “Troubleshooting.” In a UDP Plus network, the session is maintained any time the terminal is out of range or in Suspend mode.
4-24
Page 237
Co de
39 Nugget Operating the Terminal in a Network
4
Configuring the T2425 Over the Network You can remotely configure the T2425 by using one of these methods: •
Send a command from the DCS 300 (UDP Plus network only).
•
Send a command from an application on the host computer (UDP Plus and TCP/IP networks).
You cannot configure any of the RF network parameters, such as terminal IP address, over the network. Once the T2425 is communicating, you can configure bar code symbologies and operating commands. Note: You can configure the terminal locally by using the TRAKKER Antares 2400 Menu System or by scanning a command from a Code 39 or Code 93 bar code label. For help, see Chapter 3, “Configuring the Terminal.”
Configuring the T2425 From the DCS 300 You can use the DCS 300 to configure one or more T2425s in your RF network. You can also send reader commands such as Backlight On to one or more terminals. Your terminal must be configured with UDP Plus in order to communicate with the DCS 300. This method is very fast and efficient if you need to change the same configuration parameters for several terminals in one area. For example, you may want to set the Beep Volume to very loud and turn on Keypad Caps Lock for all the terminals in one area. Note: You can configure a T2425 from the DCS 300, but you cannot get configuration data from the terminal. To send commands from the DCS 300 1. Using the Download Server feature on the server, select the terminal or group to which you want to download the configuration commands. For help on configuring a group of terminals, see the DCS 300 System Manual. Note: You can continue running an application on the T2425 while configuring the terminal from the server. 2. Choose the Command option button. 3. Enter the reader or configuration command and choose Add. The command appears in the Files and Data box. For example, enter this command to set the Beep Volume to very loud: $+BV4
4-25
Page 238
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de
39 Nugget
For a list of reader commands, see Chapter 8, “Reader Command Reference.” For a list of configuration commands, see Chapter 9, “Configuration Command Reference.” Note: You can set the Postamble or Preamble command to use characters from the extended ASCII character set such as the Field Exit code for 5250 TE. For help, see “Auto-Advancing Through Fields on 5250 TE Screens” in the TRAKKER Antares Terminal Emulation User’s Guide. 4. Repeat Step 3 to add another reader or configuration command, or choose OK. 5. To save the configuration changes in flash memory on the T2425, enter this reader command as the last command and choose Add: .+1
Otherwise, the commands only change the runtime configuration. You can also use the TRAKKER Antares 2400 Menu System to save configuration changes in flash memory on the T2425. For help, see “Saving Configuration Changes in Flash Memory” in Chapter 3. 6. Choose Download to download the commands and change the configuration of the terminals selected.
Configuring the T2425 From the Host You can use an application on the host computer to configure one T2425. For example, you may want to change the Beep Volume command or the Display Backlight Timeout. To send and receive configuration data or files, you need to write an application for the host that can communicate with the DCS 300 in a UDP Plus network or directly through the access point in a TCP/IP direct connect network. You use the Terminal Message Format (TMF) protocol in the RF network to send and receive transactions between the host application and the terminal. UDP Plus is an Intermec value-added protocol. TCP/IP is an industry standard protocol. For help, see “About Network Connectivity and Protocols” later in this chapter.
Configuring the T2425 in a UDP Plus Network You can use the host computer to configure one T2425 in your 2.4 GHz RF network. For example, you may want to change the Beep Volume command and the Display Backlight Timeout. To send and receive configuration data, you need to write an application for the host that can communicate with the DCS 300. For help, see the DCS 300 Technical Reference Manual. You use the Terminal Message Format (TMF) protocol in the RF network to send and receive transactions between the host application and the terminal. Note: You can continue running an application on the T2425 while configuring the terminal.
4-26
Page 239
Co de
39 Nugget Operating the Terminal in a Network
4
To set up the DCS 300 •
Configure a peer-to-peer destination name for the host application. Create a transaction ID, $NGCFGRSP, that will be routed to this destination name. The DCS 300 uses the transaction ID to route responses from the T2425 back to the host application. $NGCFGRSP is a special transaction ID that the server uses to forward configuration response data from a terminal. All configuration responses will be routed with the $NGCFGRSP transaction ID. The DCS 300 cannot keep track of multiple applications sending reader or configuration commands. If you have two host applications sending reader or configuration commands, they must both be configured to receive the $NGCFGRSP transactions, and therefore both will receive all responses from all T2425s.
To set up the host computer •
Verify that you can communicate with the DCS 300.
To set up the application •
Prepare and write a host application that can communicate with the DCS 300 and send transactions to and receive transactions from the T2425 in this format: transaction header
TMF field
Configuration command where:
4-27 transaction header is a 96-byte field containing the message number, date and time, source application ID, destinations application ID, transaction ID, and other information. You must set the system message (SYS$MSG) flag to E in the transaction header. For help, see the DCS 300 Technical Reference Manual.
TMF field is a 2-byte field containing one of these values: CG
Configuration Get request sent from the host application.
Cg
Configuration Get response sent from the T2425 to the host.
CS
Configuration Set request sent from the host application.
Cs
Configuration Set response sent from the T2425 to the host.
Page 240
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co configuration command de
39 Nugget is the reader or configuration command or commands you want to set on the terminal, or the current value you want to retrieve from the terminal. To save configuration changes in flash memory, send the reader command .+1 as the last command. For a list of commands, see Chapter 8, “Reader Command Reference,” or Chapter 9, “Configuration Command Reference.”
To see examples of the host application transactions, see “Example 1” and “Example 2” later in this section.
Configuring the T2425 in a TCP/IP Direct Connect Network You can use the host computer to configure one T2425 in your RF network. For example, you may want to change the Beep Volume command and the Display Backlight Timeout command. To send and receive configuration data, you need to write an application for the host that can communicate with a T2425 directly via an access point. You use the Terminal Message Format (TMF) protocol in the RF network to send and receive transactions between the host application and the terminal. For more about developing an application, see “Transferring Files in a TCP/IP Direct Connect Network” later in this chapter. Note: You can continue running an application on the T2425 while configuring the terminal from the host. To set up the host computer •
Verify that you can communicate with the T2425.
To set up the application •
Prepare and write a host application that can communicate with the T2425. Configuration commands must be sent to network port 6000 on the terminal. Message transactions to and receive transactions from the T2425 on network port 6000 must conform to the following format: TMF field
Configuration command where: TMF field
4-28 is a 2-byte field containing one of these values:
Page 241
Co de
39 Nugget Operating the Terminal in a Network
TMF field configuration command
4
CG
Configuration Get request sent from the host application.
Cg
Configuration Get response sent from the T2425 to the host.
CS
Configuration Set request sent from the host application.
Cs
Configuration Set response sent from the T2425 to the host.
is the reader or configuration command or commands you want to set on the terminal, or the current value you want to retrieve from the terminal. To save configuration changes in flash memory, send the reader command .+1 as the last command. For a list of commands, see Chapter 8, “Reader Command Reference,” or Chapter 9, “Configuration Command Reference.”
Example 1 In the host application, you want to get the current values of two configuration commands from the T2425. Send this transaction from the host application: CG$+NADF
Note: The transaction header is not shown in this example. You do not need a transaction header for a host application in a TCP/IP network. where: CG is a TMF Configuration Get request.
$+ is the Change Configuration reader command.
NA is the Network Activate configuration command.
DF is the Display Backlight Timeout configuration command.
The T2425 returns this transaction to the host application. Cg$+NA1DF60 where:
4-29
Cg is a TMF Configuration Get response.
$+ is the Change Configuration reader command.
NA1 means the Network Activate configuration command is currently set to a value of 1, which means that the 2.4 GHz RF network is enabled.
DF60 means the Display Backlight Timeout configuration command is currently set to a value of 60 seconds.
Page 242
TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual Co de
39 Nugget
Example 2 In the host application, you want to set the value for two configuration commands on the T2425. Send this transaction from the host application: CS$+BV4DF30
Note: The transaction header is not shown in this example. You do not need a transaction header for a host application in a TCP/IP network. where: CS is a TMF Configuration Set request.
$+ is the Change Configuration reader command.
BV4 sets the Beep Volume configuration command to a value of 4, which is a very loud beep volume.
DF30 sets the Display Backlight Timeout configuration command to a value of 30 seconds.
The T2425 returns this transaction to the host application. Cs$+BV4DF30 where:
4-30
Cs is a TMF Configuration Set response.
$+ is the Change Configuration reader command.
BV4 means the Beep Volume configuration command has been changed to a value of 4, which is a very loud beep volume.
DF30 means the Display Backlight Timeout configuration command has been changed to a value of 30 seconds.