Trakker Antares 2400 Family System Manual: Chapter 6 - Configuration Command Reference, pages 263 to 272

Pages 263 to 272 of 362, from Trakker Antares 2400 Family System Manual

The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 2410, Intermec 2415, Intermec 2435 and Intermec 2475

Page 263

Chapter 6 - Configuration Command Reference

Syntax: YCn.data where n is: 1 2 3 4

COM1 serial port COM2 serial port (246X and 248X terminals only) COM3 serial port (242X terminals only) COM4 serial port (242X, 2455, and 248X terminals only)

Acceptable values for data are: 1 2 Default:

1 stop bit 2 stop bits

1 stop bit

Menu System: Main Menu > Configuration Menu > Communications Menu > Serial Port Bar Codes: To set the stop bits, scan one of these bar codes: 1 Stop Bit for COM1

*$+YC1.1*

2 Stop Bits for COM1

*$+YC1.2*

*$+YC1.1*

*$+YC1.2*

1 Stop Bit for COM2

2 Stop Bits for COM2

*$+YC2.1*

*$+YC2.2*

*$+YC2.1*

*$+YC2.2*

1 Stop Bit for COM3

2 Stop Bits for COM3

*$+YC3.1*

*$+YC3.2*

*$+YC3.1*

*$+YC3.2*

1 Stop Bit for COM4

2 Stop Bits for COM4

*$+YC4.1* *$+YC4.1*

*$+YC4.2*

*$+YC4.2*

Subnet Mask Terminals: 2415, 2425, 2435, 2455, 2461, 2475, 2480/1 with the Ethernet option, and 2485/6 using the TCP/IP or UDP Plus network. Description: Defines the subnet mask, an internal TCP/IP stack variable that is used to separate the subnetwork address from the local IP address. The TCP/IP stack performs a bit-wise AND on the IP address and the subnet mask. Each address segment represents one byte, where 255 converts to FF hex. This computation is used to find out if the Intermec Gateway or DCS 30X (UDP Plus), or host (TCP/IP) and terminal are on different subnetworks. If the terminal is on a different IP subnetwork than the Intermec Gateway or DCS 30X or host, you must set the subnet mask and the default router. Trakker Antares 2400 Family System Manual

243

Page 264

Chapter 6 - Configuration Command Reference

For example, if the IP address is 192.009.150.184 and the subnet mask is 255.255.255.0, the subnetwork address is 192.009.150.0. The default subnet mask 255.255.255.0 indicates that the terminal uses a standard IP network mask. Syntax: NSn.n.n.n where each n address segment is a number from 0 to 255. The subnet mask field consists of four separate numbers, each separated by a period. Default:

255.255.255.0

Menu System: Main Menu > Configuration Menu > Communications Menu > Advanced Network Bar Codes: To set the default subnet mask address, scan this bar code: Default Subnet Mask

*$+NS255.255.255.0* *$+NS255.255.255.0*

Or: To set the subnet mask: 1 Scan this bar code: Enter Accumulate Mode / Set Subnet Mask

*+/$+NS*

*+/$+NS*

2 Scan a numeric value from 0 to 255 to set an n field of the subnet mask address from these bar codes.

*0*

*0*

*2*

*2*

*4*

*4*

*6*

*6*

*8*

*8*

*1*

*1*

*3*

*3*

*5*

*5*

*7*

*7*

*9*

*9*

3 Scan this bar code: . (Period)

*.*

*.*

244

Trakker Antares 2400 Family System Manual

Page 265

Chapter 6 - Configuration Command Reference

4 Repeat Steps 2 and 3 to set the next three numbers in the subnet mask address field. After you scan the last address segment, go to Step 5. Do not scan the period after the last address segment. 5 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

Suspend/Resume Control Terminals: All Trakker Antares terminals. Description: Controls the operation of the œ key (suspend/resume). When the œ key is enabled, you can turn the terminal on and off. When the œ key is disabled, you cannot turn off the terminal. Syntax: EFdata Acceptable values for data are: 0 1 Default:

Enabled Disabled

Enabled

Menu System: Not supported Bar Codes: Scan one of these bar codes: Enable œ Key

*$+EF0* *$+EF0*

Disable œ Key

*$+EF1*

*$+EF1*

Symbology Identifiers Terminals: All Trakker Antares terminals. Description: Symbology identifiers allow you to indicate what type of data is being sent by prepending an identifier to the data. You can prepend one of the following types of character strings to identify which symbology the data is using: AIM ISO/IEC standard and user-defined ASCII character string.

Trakker Antares 2400 Family System Manual

245

Page 266

Chapter 6 - Configuration Command Reference

Symbology Identifier Character Strings Character String AIM ISO/IEC standard

Description The AIM Standard for symbology identifiers consists of a threecharacter structure indicating the symbology and the optional features of the symbology. For more information about the AIM Standard for symbology identifiers, refer to the AIM ISO/IEC Standard.

User-defined ASCII character string

The user-defined symbology identifier is one to four ASCII characters in length. You can configure user-defined symbology identifiers to assign custom identifier strings to the bar code symbologies.

The Symbology Identifiers command contains four parameters. To disable or enable all symbology identifiers to the ISO/IEC Standard, you need to configure the first two parameters. To enable a user-defined symbology identifier, you need to configure all four parameters. Syntax: CYdata where data must be 3 to 8 digits selected from this list of parameters: Digits 1-2:

Digit 3:

246

00

All Symbology IDs (Disabled or ISO/IEC Standard Enabled)

01

Code 39

02

Code 128

03

Codabar

04

Code 93

05

Code 11

06

Interleaved 2 of 5

08

PDF417

09

MSI

10

Plessey

11

Code 2 of 5 with 2 bar start/stop codes

12

Code 2 of 5 with 3 bar start/stop codes

16

UPC-A

17

UPC-E

18

EAN-8

19

EAN-13

0

Disabled

1

ISO/IEC Standard (Enabled)

2

User-defined

Trakker Antares 2400 Family System Manual

Page 267

Chapter 6 - Configuration Command Reference

Digit 4:

Digits 5-8:

1

User-defined character string length of 1

2

User-defined character string length of 2

3

User-defined character string length of 3

4

User-defined character string length of 4 xxxx

ASCII string of 1 to 4 characters in length indicating the user-defined value.

Note: The PDF417 symbology identifier is not available on terminals that are not configured to scan PDF417 bar code labels. You also may be able to define symbology identifiers for bar code symbologies that the terminal is not configured to support. Default:

000 (all symbology identifiers disabled) Note: To set this command using the bar code labels from the “Full ASCII Bar Code Chart” on page 284, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” on page 146.

Menu System: To configure symbology identifiers using the Menu System: 1 From the Main Menu, choose Configuration Menu > Symbology IDs Menu. 2 Set all symbology identifiers to the ISO/IEC Standard. a Select All Symbology IDs. b Set the command to ISO/IEC Std. (Enabled).

3 Select a symbology identifier, or select all symbology identifiers with the All Symbology IDs option. 4 Set the symbology identifier to Disabled, ISO/IEC Standard (Enabled), or User-Defined. If you select User-Defined, continue with Step 5. Otherwise continue with Step 7. If you selected the All Symbology IDs option in Step 3, you can only select Disabled or ISO/IEC Standard (Enabled). You must individually select a symbology to set a user-defined symbology identifier. 5 Set a user-defined character string length from 1 to 4. 6 Select a value for the user-defined symbology ID from the “Full ASCII Bar Code Chart” on page 284. The user-defined symbology ID should be 1 to 4 characters in length depending on the character string length value that you set in Step 5. 7 Repeat Steps 3 to 6 to configure another symbology identifier.

Trakker Antares 2400 Family System Manual

247

Page 268

Chapter 6 - Configuration Command Reference

Bar Codes: To set the default configuration and disable all symbology identifiers, scan this bar code: Disable All Symbology Identifiers

*$+CY000* *$+CY000*

Or: To set all symbology identifiers to the ISO/IEC Standard, scan this bar code: Enable ISO/IEC Standard For All Symbology Identifiers

*$+CY001* *$+CY001*

Or: To enable or disable the ISO/IEC Standard for one or more symbologies, or to set a user-defined symbology identifier for one or more symbologies: Note: If you are using firmware version 6.20 or earlier, you must set all symbology identifiers to the ISO/IEC Standard before you can set a userdefined symbology identifier. Note: To set this command using the bar code labels from the “Full ASCII Bar Code Chart” on page 284, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” on page 146. 1 Scan this bar code: Enter Accumulate Mode / Set Symbology Identifiers

*+/$+CY*

*+/$+CY*

2 Scan one of these bar codes: All Symbology IDs

*00*

*01*

*00*

*01*

Code 128

Codabar

*02*

*03*

*02*

*03*

Code 93

Code 11

*04*

*05*

*04*

*05*

Interleaved 2 of 5

PDF417

*06*

*06*

248

Code 39

*08*

*08*

Trakker Antares 2400 Family System Manual

Page 269

Chapter 6 - Configuration Command Reference MSI

*09*

Plessey

*10*

*09*

*10*

Code 2 of 5 With 2 Bar Start/Stop Codes

Code 2 of 5 With 3 Bar Start/Stop Codes

*11*

*12*

*11*

*12*

UPC-A

UPC-E

*16*

*17*

*16*

*17*

EAN-8

EAN-13

*18*

*18*

*19*

*19*

3 Scan one of these bar codes: Disable Symbology ID Symbology ID

*0*

*0*

Enable ISO/IEC Standard

*1*

*1*

Enable User-Defined Symbology ID

*2*

*2*

If you enabled a user-defined symbology identifier, continue with Step 4. Otherwise, continue with Step 6. 4 Scan a numeric value for the character string length of the user-defined symbology identifier from these bar codes:

*1*

*1*

*3*

*3*

*2*

*2*

*4*

*4*

5 Scan a value for the user-defined symbology identifier from the “Full ASCII Bar Code Chart” on page 284. The user-defined symbology identifier should be 1 to 4 characters in length depending on the character string length value that you scanned in Step 5. 6 Repeat Steps 3 to 6 to configure another symbology identifier. 7 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

Trakker Antares 2400 Family System Manual

249

Page 270

Chapter 6 - Configuration Command Reference

Example 1:

You want to enable the ISO/IEC Standard symbology identifier for all bar code symbologies except Plessey. 1 Scan this bar code: Enable ISO/IEC Standard for All Symbology Identifiers

*$+CY001*

*$+CY001*

2 Scan this bar code: Disable ISO/IEC Standard Symbology ID for Plessey

*$+CY100*

*$+CY100*

Example 2:

You want to enable a user-defined symbology identifier that is four characters in length (UPCA) for UPC-A. 1 Scan this bar code: Enable ISO/IEC Standard for All Symbology Identifiers

*$+CY001*

*$+CY001*

2 Scan this bar code: Enable 4-Character User-Defined Symbology ID (UPCA) for UPC-A

*$+CY1624UPCA*

*$+CY1624UPCA*

TCP Maximum Retries Terminals: 2415, 2425, 2435, 2455, 2461, 2475, 2480/1 with the Ethernet option, and 2485/6. Description: Defines the maximum number of times that TCP will attempt to transmit data before giving up and terminating the TCP connection. Syntax: NJdata Acceptable values for data are any number from 5 to 50. Default:

12

Menu System: Not supported Bar Codes: To set the default TCP maximum retries, scan this bar code: Default TCP Maximum Retries

*$+NJ12* *$+NJ12*

250

Trakker Antares 2400 Family System Manual

Page 271

Chapter 6 - Configuration Command Reference

Or: To set the TCP maximum retries: 1 Scan this bar code: Enter Accumulate Mode / Set TCP Maximum Retries

*+/$+NJ*

*+/$+NJ*

2 Scan a numeric value for data from these bar codes:

*0*

*0*

*2*

*2*

*4*

*1*

*1*

*3*

*3*

*5*

*4*

*5*

*6*

*7*

*6*

*8*

*8*

*7*

*9*

*9*

3 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

TCP/IP Maximum Transmit Timeout Terminals: 2415, 2425, 2435, 2455, 2461, 2475, 2480/1 with the Ethernet option, and 2485/6 using the TCP/IP network. Description: Defines the maximum timeout that TCP will allow between retries of a transmission in a TCP/IP direct connect network before it gives up. For example, a value of 20 indicates that the timeout between retries is never longer than 20 seconds. Intermec has determined that the optimum setting is 20 seconds. Syntax: NHdata Acceptable values for data are: 0 1-128 Default:

No timeout Transmit timeout in seconds

20 seconds

Menu System: Main Menu > Configuration Menu > Communications Menu > Advanced Network

Trakker Antares 2400 Family System Manual

251

Page 272

Chapter 6 - Configuration Command Reference

Bar Codes: To set the default TCP/IP maximum transmit timeout, scan this bar code: Default TCP/IP Maximum Transmit Timeout

*$+NH20* *$+NH20*

Or: To set the TCP/IP maximum transmit timeout: 1 Scan this bar code: Enter Accumulate Mode / Set TCP/IP Maximum Transmit Timeout

*+/$+NH*

*+/$+NH*

2 Scan a numeric value for data from these bar codes:

*0*

*0*

*2*

*2*

*4*

*4*

*6*

*6*

*8*

*8*

*1*

*1*

*3*

*3*

*5*

*5*

*7*

*7*

*9*

*9*

3 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

Terminal IP Address Terminals: 2415, 2425, 2435, 2455, 2461, 2475, 2480/1 with the Ethernet option, and 2485/6. Description: Defines the IP address assigned to the terminal in your RF or Ethernet network. An IP address is a unique network level address you assign to each device in a TCP/IP network. The IP address you set on the terminal must be the same as the address that is set on the Intermec Gateway, DCS 30X or host computer. Syntax: NDn.n.n.n where each n address segment is a number from 0 to 255. The terminal IP address field consists of four separate numbers, each separated by a period.

252

Trakker Antares 2400 Family System Manual