Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 28 of 38

Trakker Antares 2400 Family System Manual: Chapter 6 - Configuration Command Reference, pages 253 to 262

Pages 253 to 262 of 362, from Trakker Antares 2400 Family System Manual

The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 2410, Intermec 2415, Intermec 2435 and Intermec 2475

Page 253

Chapter 6 - Configuration Command Reference

Bar Codes: Scan one of these bar codes: All Compatible Scanners

*$+SS0*

146X CCD Scanners

*$+SS1*

*$+SS0*

*$+SS1*

151X Laser Scanners

1545 Laser Scanner

*$+SS3*

*$+SS4*

*$+SS3*

*$+SS4*

Compatible Symbol Scanners

155X Laser Scanners

*$+SS5*

*$+SS6*

*$+SS5*

*$+SS6*

Tethered Long Range Laser Scanners

Integrated Scanner

*$+SS7*

*$+SS10*

Integrated Scanner / Scan Module (No Aim)

Integrated Scanner / Scan Module (Short Aim)

*$+SS7*

*$+SS11*

*$+SS10*

*$+SS12*

*$+SS11*

*$+SS12*

Integrated Scanner / Scan Module (Long Aim)

Integrated PDF417 Laser Scanner / Scan Module

*$+SS13* *$+SS13*

*$+SS14*

*$+SS14*

Intermec 1551E PDF417 Laser Scanner Integrated Linear Imager

*$+SS15*

*$+SS16*

*$+SS15*

*$+SS16*

Intermec 1553 XLR Laser Scanner

No Scanner

*$+SS17* *$+SS17*

*$+SS98*

*$+SS98*

Scanner Timeout Terminals: All Trakker Antares terminals. Description: Defines the maximum length of time the scanner stays on after you press the Scan button or activate a laser scanner that is connected to the terminal. Note: Scanner Timeout is not supported on PDF417 scanners, as well as, some tethered decoded scanners. For help, contact your local Intermec service representative.

Trakker Antares 2400 Family System Manual

233

Page 254

Chapter 6 - Configuration Command Reference

Syntax: SAdata Acceptable values for data are: 0 1-60 3-60

Disabled Shutoff time in seconds Shutoff time in seconds (decoded scanners with Scanner Trigger set to pulse triggering)

Note: If you are using a decoded scanner, the scanner defaults to a timeout of 3 seconds. The menu system may display the default scanner timeout value of Disabled, however, the actual timeout is 3 seconds. Do not try to set the scanner timeout to Disabled. Default:

Disabled (no timeout)

Menu System: Main Menu > Configuration Menu > Terminal Menu > Scanner Bar Codes: To set the default scanner timeout, scan this bar code: Disable Scanner Timeout

*$+SA0* *$+SA0*

Or: To set the scanner timeout: 1 Scan this bar code: Enter Accumulate Mode / Set Scanner Timeout

*+/$+SA*

*+/$+SA*

2 Scan a numeric value for data from these bar codes:

*0*

*0*

*2*

*2*

*4*

*4*

*6*

*6*

*8*

*8*

*1*

*1*

*3*

*3*

*5*

*5*

*7*

*7*

*9*

*9*

3 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

234

Trakker Antares 2400 Family System Manual

Page 255

Chapter 6 - Configuration Command Reference

Scanner Trigger Terminals: All Trakker Antares terminals. Description: Scanner trigger allows you to set level triggering and either edge or pulse triggering depending on the type of scanner you are using. There are three triggering options: level, edge, and pulse. Scanner Trigger Options Option Level triggering

Description Level triggering is available on terminals using either decoded or non-decoded scanners. With level triggering, when you activate the scanner, the laser turns on and stays on until you release the trigger on the laser scanner.

Edge triggering

Edge triggering is available on terminals using non-decoded scanners. With edge triggering, when you activate the scanner, the laser turns on and stays on. When you activate the scanner a second time, the laser turns off. Simply releasing the button or trigger does not turn off the laser. If the laser is left on, the scanner timeout turns the laser off.

Pulse triggering

Pulse triggering is supported on 241X terminals using the integrated PDF417 scanner or linear imager and on 242X terminals using the PDF417 scan module. With pulse triggering, when you activate the scanner, the laser turns on. The laser remains on until the scanner timeout turns the laser off. If the scanner timeout is set to 0, the laser turns off after 3 seconds.

Note: Earlier versions of PDF417 scanners do not support pulse triggering. For help upgrading your scanner, contact your local Intermec service representative. Syntax: SCdata Acceptable values for data are: 0 1 Default:

Level triggering Edge or Pulse triggering

Level triggering

Menu System: Main Menu > Configuration Menu > Terminal Menu > Scanner Bar Codes: Scan one of these bar codes: Enable Level Triggering

Enable Edge or Pulse Triggering

*$+SC0*

*$+SC1*

*$+SC0*

Trakker Antares 2400 Family System Manual

*$+SC1*

235

Page 256

Chapter 6 - Configuration Command Reference

Security Identification (ID) Terminals: 2415, 2425, 2435, 2455, 2475, and 2485/6 with OpenAir radios. Description: Defines a password for secured transmission and receipt of data between devices in the RF network. To communicate, all access points and RF terminals in the subnetwork must have the same security ID. Note: The Network Activate command must be configured to the RF network before you can save any changes to this parameter. Syntax: RSdata Acceptable values for data are up to 20 ASCII characters. Default:

No characters or blank (Disabled)

Menu System: Main Menu > Configuration Menu > Communications Menu > Radio The actual security ID does not appear on the screen. The words (ID unchanged) indicate that the password has not been changed in the current menu session. If you change the security ID, you see the new password until you exit the Configuration Menu and update the current (runtime) configuration. Bar Codes: To disable or set the security ID to no characters, scan this bar code label: Disable Security ID

*$+RS* *$+RS*

Or: To set the security ID to an ASCII character string: Note: To set this command using the bar code labels from the “Full ASCII Bar Code Chart” on page 284, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” on page 146. 1 Scan this bar code: Enter Accumulate Mode / Set Security ID

*+/$+RS*

*+/$+RS*

2 Scan a value for data from the “Full ASCII Bar Code Chart” on page 284. The security ID can be from 1 to 20 characters. 3 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

236

Trakker Antares 2400 Family System Manual

Page 257

Chapter 6 - Configuration Command Reference

Serial Port Protocol Terminals: All Trakker Antares terminals. Description: Allows you to set the protocol that the serial port uses to communicate with the connected device. Communications protocols determine exactly how data is transmitted between the terminal and the serial device. Each protocol has parameters you can set, such as baud rate and parity. Both the terminal and the serial device must use the same protocol and parameter settings to communicate properly. The terminal can communicate in these five protocols: • Binary • Configurable protocol • Master Polling • Multi-Drop (COM2 only) • Polling Mode D Additionally, you can simulate Point-to-Point protocol by modifying the Configurable protocol. Each protocol is described in the networking chapter in your user’s manual. Syntax: YUn.data where n is: 1 2 3 4

COM1 serial port COM2 serial port (246X and 248X terminals only) COM3 serial port (242X terminals only) COM4 serial port (242X, 2455, and 248X terminals only)

Acceptable values for data are: 0 Configurable 2 Polling mode D 3 Multi-Drop (COM2 only) 8 Master polling mode D 12 Binary Default:

Configurable

Menu System: Main Menu > Configuration Menu > Communications Menu > Serial Port Bar Codes: To set the default serial port protocol, scan one of these bar codes: Configurable Protocol for COM1

*$+YU1.0* *$+YU1.0*

Trakker Antares 2400 Family System Manual

Configurable Protocol for COM2

*$+YU2.0*

*$+YU2.0*

237

Page 258

Chapter 6 - Configuration Command Reference Configurable Protocol for COM3

*$+YU3.0* *$+YU3.0*

Configurable Protocol for COM4

*$+YU4.0*

*$+YU4.0*

Or: To set the serial port protocol for one serial port: 1 Scan this bar code: Enter Accumulate Mode / Set Serial Port Protocol

*+/$+YU*

*+/$+YU*

2 Scan one of these bar codes to set the COM port: COM1

COM2

*1.*

*2.*

COM3

COM4

*3.*

*4.*

*1.*

*3.*

*2.*

*4.*

3 Scan the protocol setting: Configurable

*0*

Polling Mode D

*2*

*0*

*2*

Multi-Drop

Master Polling Mode D

*3*

*3*

*8*

*8*

Binary

*12*

*12*

4 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

5 Repeat Steps 1 through 4 to set the serial port protocol for another port.

238

Trakker Antares 2400 Family System Manual

Page 259

Chapter 6 - Configuration Command Reference

Server Certificate Common Name (Server Cert CN) Terminals: 2415, 2425, 2435, 2455, 2475, and 2485/6 with an 802.11b radio with 802.1x security. Description: The Server Certificate Common Name (Server Cert CN) is the name of the certificate on the authentication server. You obtain this value from the authentication server. You only need to identify one server cert CN for secure data transmission, however, you can also identify a second server cert CN for a backup authentication server. If the name of the certificate on the authentication server is longer than 32 characters, configure the server cert CN for the first 32 characters. You can authenticate to a certificate with a name that is longer than 32 characters, however, the terminal will only check the first 32 characters. Syntax: LUdata LVdata

Server 1 Certificate Common Name Server 2 Certificate Common Name

Acceptable values for data are from 1 to 32 ASCII characters. Default:

No characters or blank (Disabled) Note: You can leave the server certificate common name blank if you just want to make sure that your terminal can be authenticated. However, you must set a unique user name, password, and at least one server certificate common name for secure data transmission.

Menu System: Main Menu > Configuration Menu > Communications Menu > Radio Bar Codes: To disable or set the default server certificate common name to no characters, scan one of these bar codes: Disable Server 1 Cert CN

Disable Server 2 Cert CN

*$+LU*

*$+LV*

*$+LU*

*$+LV*

Or: To set the server certificate common name to an ASCII character string: Note: To set this command using the bar code labels from the “Full ASCII Bar Code Chart” on page 284, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” on page 146. 1 Scan this bar code: Enter Accumulate Mode / Set Server 1 Cert CN

Enter Accumulate Mode / Set Server 2 Cert CN

*+/$+LU*

*+/$+LV*

*+/$+LU*

Trakker Antares 2400 Family System Manual

*+/$+LV*

239

Page 260

Chapter 6 - Configuration Command Reference

2 Scan a value for data from the “Full ASCII Bar Code Chart” on page 284. The server certificate common name can be from 1 to 32 characters. 3 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

Start of Message (SOM) Terminals: All Trakker Antares terminals. Description: SOM is the first character in a message sent to or received from the host computer through one of the terminal’s serial ports. You can configure LRC for the Configurable communications protocol. For more information, see the networking chapter in your user’s manual. You can set SOM to use characters from the extended ASCII character set using the TRAKKER Antares 2400 Menu System. This procedure is similar to the one for setting the preamble and postamble. For help, see “Entering ASCII Control Characters” in the configuration chapter in your user’s manual. SOM cannot equal the same value that is set for EOM. You cannot set SOM to any of these values: • AFF (ACK)

• REQ (ENQ)

• DLE

• SEL

• NEG (NAK)

• XOFF

• Poll

• XON

• RES (EOT) Note: Before you can enable SOM, you must configure the EOM command. Syntax: YYn.data where n is: 1 2 3 4

COM1 serial port COM2 serial port (246X and 248X terminals only) COM3 serial port (242X terminals only) COM4 serial port (242X, 2455, and 248X terminals only)

An acceptable value for data is any ASCII character. Default:

240

\x02 (hexadecimal value for STX)

Trakker Antares 2400 Family System Manual

Page 261

Chapter 6 - Configuration Command Reference

Menu System: Main Menu > Configuration Menu > Communications Menu > Serial Port Bar Codes: To disable SOM for each serial port, scan these bar codes: Disable SOM for COM1

*$+YY1.*

Disable SOM for COM2

*$+YY2.*

*$+YY1.*

*$+YY2.*

Disable SOM for COM3

Disable SOM for COM4

*$+YY3.* *$+YY3.*

*$+YY4.*

*$+YY4.*

Or: To set SOM to an ASCII character for one serial port: Note: To set this command using the bar code labels from the “Full ASCII Bar Code Chart” on page 284, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” on page 146. 1 Scan this bar code: Enter Accumulate Mode / Set SOM

*/K/O/D/KYY*

*+/$+YY*

2 Scan the serial port from these bar codes: COM1

*1.*

COM2

*2.*

*1.*

*2.*

COM3

COM4

*3.*

*3.*

*4.*

*4.*

3 Scan a bar code for data from the “Full ASCII Bar Code Chart” on page 284. 4 Scan this bar code: Exit Accumulate Mode

*/M/O*

*-/*

5 Repeat Steps 1 through 4 to set SOM for another serial port.

Trakker Antares 2400 Family System Manual

241

Page 262

Chapter 6 - Configuration Command Reference

Station Name Terminals: 2415, 2425, 2435, 2455, 2475, and 2485/6 with 802.11b radios. Description: Identifies the RF terminal to the network. For example, you may want to define station names so that you can identify RF terminals when using site survey tools. Syntax: LBdata Acceptable values for data are up to 32 ASCII characters. Default:

Trakker 2400

Menu System: Main Menu > Configuration Menu > Communications Menu > Radio Bar Codes: To set the default station name, scan this bar code: Default Station Name

*$+LBTRAKKER 2400* *$+LBTRAKKER 2400*

Or: To set the station name to an ASCII character string: Note: To set this command using the bar code labels from the “Full ASCII Bar Code Chart” on page 284, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” on page 146. 1 Scan this bar code: Enter Accumulate Mode / Set Station Name

*+/$+LB*

*+/$+LB*

2 Scan a value for data from the “Full ASCII Bar Code Chart” on page 284. The station name can be from 1 to 32 characters. 3 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

Stop Bits Terminals: All Trakker Antares terminals. Description: Sets the number of stop bits on the serial port. You can configure the stop bits for the Binary and Configurable communications protocols. For more information, see the networking chapter in your user’s manual.

242

Trakker Antares 2400 Family System Manual