Page 243

Chapter 6 - Configuration Command Reference

Menu System: N/A Bar Codes: N/A

RAM Drive Size Terminals: All Trakker Antares terminals. Description: Configures the size and use of the RAM drive (drive E). You can use the RAM drive to temporarily store data and files. You can also disable the RAM drive and use the additional 256K for application execution space or programmable (Malloc) memory allocations. After you set the RAM drive, you must save the configuration in flash memory and boot the terminal for the change to take effect. Note: When you boot or reset the terminal, all files on the RAM drive are destroyed. Syntax: FRdata Acceptable values for data are: 0 1256 Default:

Disabled, no RAM drive RAM drive size in kilobytes (K)

0 (Disabled)

Menu System: Main Menu > Configuration Menu > Terminal Menu > RAM Drive Bar Codes: To disable the RAM drive, scan this bar code: Disable RAM Drive

*$+FR0* *$+FR0*

Or: To set the RAM drive size: 1 Scan this bar code: Enter Accumulate Mode / Set RAM Drive Size

*+/$+FR*

*+/$+FR*

2 Scan a numeric value for data from these bar codes:

*0*

*0*

*2*

*2*

Trakker Antares 2400 Family System Manual

*1*

*1*

*3*

*3*

223

Page 244

Chapter 6 - Configuration Command Reference

*4*

*5*

*4*

*5*

*6*

*7*

*6*

*7*

*8*

*9*

*8*

*9*

3 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

4 Scan this bar code to save the configuration change in flash memory: Save Configuration in Flash Memory

*.+1*

*.+1*

5 Scan this bar code to boot the terminal and use the RAM drive: Reset Firmware

*-.*

*-.*

Receive All Multicast Terminals: 2415, 2425, 2435, 2455, 2475, and 2485/6 with 802.11b radios. Description: Determines if the RF terminal needs to receive all multicast messages. If you enable this parameter, the radio stays awake to receive all multicast messages forwarded by the access point. If you disable this parameter, the radio sleeps more often and conserves battery power. Note: Before you can set receive all multicast, you must enable the Power Management command. Syntax: LJdata Acceptable values for data are: 0 1 Default:

Disabled Enabled

Enabled

Menu System: Main Menu > Configuration Menu > Communications Menu > Radio

224

Trakker Antares 2400 Family System Manual

Page 245

Chapter 6 - Configuration Command Reference

Bar Codes: Scan one of these bar codes: Disable Receive All Multicast

*$+LJ0* *$+LJ0*

Enable Receive All Multicast

*$+LJ1*

*$+LJ1*

Reservation Threshold Terminals: 2415, 2425, 2435, 2455, 2475, and 2485/6 with 802.11b radios. Description: Specifies the maximum packet size that the RF terminal can send before it uses medium reservation (RTS/CTS). Packets that are greater than or equal to this packet size use the medium reservation mechanism to help prevent collisions with packets from other devices. Note: Reservation Threshold is only used when the Medium Reservation command is enabled. Syntax: LDdata Acceptable values for data are from 1 to 2346. Default:

500

Menu System: Main Menu > Configuration Menu > Communications Menu > Radio Bar Codes: To set the default reservation threshold, scan this bar code: Default Reservation Threshold

*$+LD500* *$+LD500*

Or: To set the reservation threshold: 1 Scan this bar code: Enter Accumulate Mode / Set Reservation Threshold

*+/$+LD*

*+/$+LD*

2 Scan a numeric value for data from these bar codes:

*0*

*0*

*2*

*2*

*4*

*4*

Trakker Antares 2400 Family System Manual

*1*

*1*

*3*

*3*

*5*

*5*

225

Page 246

Chapter 6 - Configuration Command Reference

*6*

*6*

*8*

*8*

*7*

*7*

*9*

*9*

3 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

Resume Execution Terminals: All Trakker Antares terminals. Description: Defines the way in which the terminal resumes when you press œ to turn on the terminal. If you set this parameter to resume not allowed and you press œ to turn off the terminal, it will boot and restart the application that was running when you turned off the terminal. If you set this parameter to resume allowed and press œ to turn on the terminal, the terminal resumes exactly where it was when you turned off the terminal. If resume is set to not allowed, when you press œ to turn off the terminal, the terminal will end the host connection before it turns off. Do not try to turn on the terminal immediately after you turn it off. Syntax: ERdata Acceptable values for data are: 0 1 Default:

Not allowed Allowed

Allowed

Menu System: Main Menu > Configuration Menu > Terminal Menu > Power Management Bar Codes: Scan one of these bar codes: Resume Execution Not Allowed

*$+ER0* *$+ER0*

Resume Execution Allowed

*$+ER1*

*$+ER1*

RS-232 or RS-422/485 COM2 Interface Terminals: 2460 and 248X with enhanced I/O board option. Description: Defines the interface for the COM2 communications port. If you have a 2460 or a 248X with an enhanced input/output board, you can use 226

Trakker Antares 2400 Family System Manual

Page 247

Chapter 6 - Configuration Command Reference

COM2 for either RS-232 or RS-422/485 communications. If you are using Multi-Drop protocol, you do not need to set this parameter because the terminal automatically sets the RS-485 interface. Syntax: YK2.data Acceptable values for data are: 0 1 Default:

RS-232 RS-422/485

RS-232

Menu System: Main Menu > Configuration Menu > Communications Menu > Serial Port [COM2] Bar Codes: To set the interface for COM2, scan one of these bar codes: Enable RS-232 Interface

Enable RS-422/485 Interface

*$+YK2.0*

*$+YK2.1*

*$+YK2.0*

$+YK2.1*

Roaming Flag Terminals: 2415, 2425, 2435, 2455, 2475, and 2485/6 with OpenAir radios. Description: Determines whether or not the RF terminal can roam between access points. All access points are master stations, and each master has a unique channel. If you have five access points in one domain, the RF terminal will connect to one access point when you turn it on. This access point becomes the master station for the RF terminal. When you set the roaming flag to “Not Allowed,” the RF terminal will only communicate with the master station (access point) to which it first connects. If you allow roaming, the RF terminal can communicate with any access point in the same domain. Syntax: RRdata Acceptable values for data are: 0 1 Default:

Allowed Not allowed

Allowed

Menu System: Main Menu > Configuration Menu > Communications Menu > Radio Bar Codes: Scan one of these bar codes: Roaming Allowed

*$+RR0* *$+RR0*

Trakker Antares 2400 Family System Manual

Roaming Not Allowed

*$+RR1*

*$+RR1*

227

Page 248

Chapter 6 - Configuration Command Reference

Scan Ahead Terminals: All Trakker Antares terminals. Description: Enables or disables scan ahead. If you enable this parameter, you can scan a number of labels that are held in a stack until the terminal can process the data. If you disable this parameter, the terminal processes each label you scan before you can scan the next label. Syntax: SDdata Acceptable values for data are: 0 1 Default:

Disabled (scan one label at a time) Enabled (scan many labels at a time)

Disabled

Menu System: Main Menu > Configuration Menu > Terminal Menu > Scanner Bar Codes: Scan one of these bar codes: Disable Scan Ahead

Enable Scan Ahead

*$+SD0*

*$+SD1*

*$+SD0*

*$+SD1*

Scanner Mode Terminals: All Trakker Antares terminals. Description: Defines how the scanner operates when you press the Scan button or activate a laser scanner that is connected to the terminal. There are two modes: one-shot and automatic. Scanner Modes Mode One-shot

Description In one-shot mode, you need to press the Scan button or activate the laser scanner each time you want to scan a bar code. After you scan a bar code, the scanner turns off.

Automatic

In automatic (auto-trigger) mode, you press the Scan button once or activate the laser scanner once to scan a series of bar codes. When you release the button or trigger, the scanner turns off. To scan the same bar code more than once, you need to release the button or trigger, or scan a different bar code before attempting a second scan. Note: Automatic mode is not supported on some tethered decoded scanners. For help, contact your local Intermec service representative.

228

Trakker Antares 2400 Family System Manual

Page 249

Chapter 6 - Configuration Command Reference

Syntax: SBdata Acceptable values for data are: 0 1 Default:

One-shot mode Automatic mode

One-Shot mode

Menu System: Main Menu > Configuration Menu > Terminal Menu > Scanner Bar Codes: Scan one of these bar codes: Enable One-Shot Mode

Enable Automatic Mode

*$+SB0*

*$+SB1*

*$+SB0*

*$+SB1*

Scanner Port (COM4) Terminals: 2455. Description: Allows you to configure the Scanner port to function either as a Scanner port or as an additional serial port (COM4). There are three options: scanner port, RS-232 port, and inverted RS-232 port. Scanner Port Options Option Scanner port

Description Allows you to connect a scanner to the Scanner port on the bottom back panel of the 2455.

RS-232 port

Allows you to use the Scanner port as COM4 to connect a serial device. In this configuration, the Scanner port supports TTL voltage-level (0-5V) serial devices.

Inverted RS-232 port

Allows you to use the Scanner port as COM4 to connect a serial device. In this configuration, the Scanner port supports inverted TTL voltage-level serial devices.

If you plan to use the Scanner port as COM4, you need to order the COM Port Adapter Cable (Part No. 061799). You must use this cable to connect a serial device to COM4. This cable does not provide an environmentally sealed connection to the 2455. Syntax: IXdata Acceptable values for data are: 0 1 2 Default:

Scanner port RS-232 (COM4) port Inverted RS-232 (COM4) port

Scanner port enabled

Trakker Antares 2400 Family System Manual

229

Page 250

Chapter 6 - Configuration Command Reference

Menu System: Main Menu > Configuration Menu > Terminal Menu > Scanner Bar Codes: Scan one of these bar codes: Enable Scanner Port

*$+IX0* *$+IX0*

Enable RS-232 (COM4) Port

*$+IX1*

*$+IX1*

Enable Inverted RS-232 (COM4) Port

*$+IX2* *$+IX2*

Scanner Redundancy Terminals: All Trakker Antares terminals. Description: Defines the number of scans (voting) of a bar code label that must decode correctly for a good read of the label. Voting requires the terminal to decode the same bar code multiple times during a single scanner event and to compare the decoded information a specific number of times before signaling a good read. There are three options: none, normal, and high. Scanner Redundancy Options Option None

Description Allows the terminal to accept the first good read. This setting speeds up terminal performance and is recommended when scanning good quality bar code labels.

Normal

The terminal decodes the bar code a minimum number of times in each scanner event. The number of comparisons that are made depends on each bar code symbology.

High

The terminal decodes the bar code a maximum number of times in each scanner event. The number of comparisons depends on each bar code symbology. This setting is recommended when scanning poor quality labels that may cause substitution errors.

Syntax: SRdata Acceptable values for data are: 0 1 2 Default:

None Normal High

Normal

Menu System: Main Menu > Configuration Menu > Terminal Menu > Scanner

230

Trakker Antares 2400 Family System Manual

Page 251

Chapter 6 - Configuration Command Reference

Bar Codes: Scan one of these bar codes: Scanner Redundancy None

*$+SR0* *$+SR0*

Scanner Redundancy Normal

*$+SR1*

*$+SR1*

Scanner Redundancy High

*$+SR2* *$+SR2*

Scanner Selection Terminals: All Trakker Antares terminals. Description: Identifies the type of scanner you have connected to the terminal. The terminal can optimize the scanning performance by using the scanner you define in this command. When you select a specific scanner, other scanners may not function properly. Your terminal may not work if you connect an incompatible scanner or if you select an incorrect option for your input device. For 241X, 242X, and 243X terminals, you can also use this command to configure the spotting beam when you have a long range or high visibility scanner on the terminal. There are three options: no aim, short aim, and long aim. Scanner Selection Options Option No aim

Description The spotting beam is turned off. When you press the Scan button, the laser scanner starts scanning immediately.

Short aim

The spotting beam appears for 400 ms to help you aim the laser scanner before it starts scanning.

Long aim

The spotting beam appears for 1 second to help you aim the laser scanner before it starts scanning.

For 242X terminals, the Scanner Selection configuration command is only used when a module for cabled scanners, long range scan module, or a high visibility scan module is installed on the terminal. Note: For 243X terminals, you must define this command and select the tethered input device that is connected to the terminal. If this command is not defined for the appropriate input device, the scanner trigger on the input device may activate the integrated scanner on the terminal.

Trakker Antares 2400 Family System Manual

231

Page 252

Chapter 6 - Configuration Command Reference

Syntax: SSdata where acceptable values for data are listed in the next table. Scanner Selection: Acceptable Values for Data Value 0

Description All compatible scanners (including wands)

1

146X CCD scanners (242X, 2455, 246X, 2475, 248X)

3

151X laser scanners (242X, 2455, 246X, 2475, 248X)

4

1545 laser scanner (242X, 2455, 246X, 2475, 248X)

5

Non-Intermec tethered laser scanners

6

155X laser scanners

7

Tethered long range laser scanners (242X, 2455, 246X, 2475, 248X)

10

Integrated (241X, 242X, 243X)

11

Integrated scanner / scan module, including normal, long range, high density, or high visibility (long range or high visibility with no aim) (241X, 242X, 243X)

12

Integrated long range, high density, or high visibility scanner / scan module with short aim (241X, 242X, 243X)

13

Integrated long range, high density, or high visibility scanner / scan module with long aim (241X, 242X, 243X)

14

Integrated PDF417 scanner / scan module (241X, 242X)

15

Serial PDF417 scanner (Intermec 1551E laser scanner) (241X, 242X, 243X)

16

Integrated non-PDF417 linear imager (241X)

17

Serial non-PDF417 scanner (Intermec 1553 XLR laser scanner) (242X, 243X)

98

No scanner

For help configuring a long range laser scanner, see the user’s manual that shipped with your scanner. Note: For 242X terminals, SS0 through SS7 work only when a module for cabled scanners is installed on the terminal. SS12 and SS13 work only when a long range or high visibility scan module is installed. SS11 configures the standard range and high density scan modules. Note: If you are using the advanced long range scanner or scan module, you may not be able to scan the bar code labels in this manual. However, you can still send commands through the serial port or network. For help, see Chapter 2, “Configuring and Managing the Terminals.” Default:

Specific integrated scanner installed on the terminal (integrated scanners) All compatible scanners (tethered scanners)

Menu System: Main Menu > Configuration Menu > Terminal Menu > Scanner

232

Trakker Antares 2400 Family System Manual