The text of a manual · part 26 of 38

Trakker Antares 2400 Family System Manual: Chapter 6 - Configuration Command Reference, pages 233 to 242

Pages 233 to 242 of 362, from Trakker Antares 2400 Family System Manual

The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 2410, Intermec 2415, Intermec 2435 and Intermec 2475

Page 233

Chapter 6 - Configuration Command Reference

Network Port Terminals: 2415, 2425, 2435, 2455, 2461, 2475, 2480/1 with the Ethernet option, and 2485/6 using the TCP/IP or UDP Plus network. Description: Defines the network port that TCP/IP or UDP Plus uses for communications in the RF or Ethernet network. In a TCP/IP network, set the network port to the appropriate port for the application you are using on the terminal. The default network port value, which is 23, enables VT/ANSI Telnet communications. In a UDP Plus network, set the network port on the terminal to the same value as the network port on the Intermec Gateway or DCS 30X. Syntax: NGdata Acceptable values for data are any number from 1 to 65535. Default:

00023 Terminal with TCP/IP 05555 Terminal with UDP Plus

Menu System: Main Menu > Configuration Menu > Communications Menu > Advanced Network Bar Codes: To set the default network port for a terminal with TCP/IP, scan this bar code: Default Network Port for TCP/IP

*$+NG23* *$+NG23*

To set the default network port for a terminal with UDP Plus, scan this bar code: Default Network Port for UDP Plus

*$+NG5555* *$+NG5555*

Or: To set the network port: 1 Scan this bar code: Enter Accumulate Mode / Set Network Port

*+/$+NG*

*+/$+NG*

2 Scan a numeric value for data from these bar codes:

*0*

*0*

*2*

*2*

Trakker Antares 2400 Family System Manual

*1*

*1*

*3*

*3*

213

Page 234

Chapter 6 - Configuration Command Reference

*4*

*4*

*6*

*6*

*8*

*8*

*5*

*5*

*7*

*7*

*9*

*9*

3 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

Parity Terminals: All Trakker Antares terminals. Description: Sets the parity for the serial port. The terminal uses parity for error checking in data transmissions. You can configure parity for the Binary and Configurable communications protocols. For more information, see the networking chapter in your user’s manual. Syntax: YBn.data where n is: 1 2 3 4

COM1 serial port COM2 serial port (246X and 248X terminals only) COM3 serial port (242X terminals only) COM4 serial port (242X, 2455, and 248X terminals only)

Acceptable values for data are: 0 1 2 Default:

No parity Even parity Odd parity

Even

Menu System: Main Menu > Configuration Menu > Communications Menu > Serial Port Bar Codes: To set the default parity for each serial port, scan these bar codes: Even Parity for COM1

*$+YB1.1*

*$+YB2.1*

*$+YB1.1*

*$+YB2.1*

Even Parity for COM3

Even Parity for COM4

*$+YB3.1* *$+YB3.1* 214

Even Parity for COM2

*$+YB4.1*

*$+YB4.1*

Trakker Antares 2400 Family System Manual

Page 235

Chapter 6 - Configuration Command Reference

Or: To set no parity for each serial port, scan these bar codes: No Parity for COM1

*$+YB1.0*

No Parity for COM2

*$+YB2.0*

*$+YB1.0*

*$+YB2.0*

No Parity for COM3

No Parity for COM4

*$+YB3.0* *$+YB3.0*

*$+YB4.0*

*$+YB4.0*

Or: To set an odd parity for each serial port, scan these bar codes: Odd Parity for COM1

Odd Parity for COM2

*$+YB1.2*

*$+YB2.2*

*$+YB1.2*

*$+YB2.0*

Odd Parity for COM3

Odd Parity for COM4

*$+YB3.2*

*$+YB4.2*

*$+YB3.2*

*$+YB4.2*

Password Terminals: 2415, 2425, 2435, 2455, 2475, and 2485/6 with an 802.11b radio and the 802.1x security option. Description: Defines the password of the terminal for 802.1x security. If you enter a password that is longer than 32 characters, the string is truncated, and only the first 32 characters are used. The password field always displays three asterisks symbols (*) regardless of the length of your password. Syntax: LTdata Acceptable values for data are from 1 to 32 ASCII characters. Default:

anonymous Note: You can use the default password to make sure that your terminal can be authenticated. However, you must set a unique user name, password, and at least one server certificate common name for secure data transmission.

Menu System: Main Menu > Configuration Menu > Communications Menu > Radio Bar Codes: To set the default password, scan this bar code: Default Password

*/D/KLT+A+N+O+N+Y+M+O+U+S* *$+LTanonymous*

Trakker Antares 2400 Family System Manual

215

Page 236

Chapter 6 - Configuration Command Reference

Or: To set the password to an ASCII character string: Note: To set this command using the bar code labels from the “Full ASCII Bar Code Chart” on page 284, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” on page 146. 1 Scan this bar code: Enter Accumulate Mode / Set Password

*+/$+LT*

*+/$+LT*

2 Scan a value for data from the “Full ASCII Bar Code Chart” on page 284. The password can be from 1 to 32 characters. 3 Scan this bar code: Exit Accumulate Mode

*-/* *-/*

PDF417 Terminals: 241X, 242X, and 243X terminals with a PDF417 scanner. Description: The PDF417 symbology is a stacked 2D symbology that allows you to scan across rows of code. Each row consists of start/stop characters, row identifiers, and symbol characters, which consist of four bars and four spaces each and contain the actual data. This symbology uses error correction symbol characters appended at the end to recover loss of data. Note: PDF417 is a decoded bar code symbology and requires at least one data value in a bar code. Therefore, if the terminal is configured to scan decoded bar code symbologies, it cannot scan the Enter reader command, which only consists of a Start and Stop character and does not contain any data values. Syntax: CQdata Acceptable values for data are: 0 1 Default:

Disabled Enabled

Enabled

Menu System: Main Menu > Configuration Menu > Symbologies Menu

216

Trakker Antares 2400 Family System Manual

Page 237

Chapter 6 - Configuration Command Reference

Bar Codes: Scan one of these bar codes: Disable PDF417

*$+CQ0* *$+CQ0*

Enable PDF417

*$+CQ1*

*$+CQ1*

Plessey Terminals: All Trakker Antares terminals. Description: Enables or disables decoding of Plessey symbology. Plessey code is pulse-width modulated like most other bar codes. It includes a start character, data characters, an eight-bit cyclic check digit, a termination bar, and usually a reverse start character. The code is continuous and not selfchecking. You need to configure two parameters for Plessey code: Start Code and Check Digit. Syntax: CIdata Acceptable values for data are: 00 Disabled 10 Plessey with reverse start code 30 Transmit check digit 31 Discard check digit Default:

Disabled

Menu System: Main Menu > Configuration Menu > Symbologies Menu > Plessey Bar Codes: To disable Plessey: Disable Plessey

*$+CI00* *$+CI00*

Or: To set Plessey, complete these steps: 1 Scan this bar code: Plessey With Reverse Start Code

*$+CI10*

*$+CI10*

2 Scan one of these bar codes to transmit or retain the check digit: Transmit Check Digit

*$+CI30*

*$+CI30*

Trakker Antares 2400 Family System Manual

Discard Check Digit

*$+CI31*

*$+CI31*

217

Page 238

Chapter 6 - Configuration Command Reference

Poll (Polling) Terminals: All Trakker Antares terminals. Description: Solicits or requests data from a polled device. You can configure polling for the Configurable communications protocol. For more information, see the networking chapter in your user’s manual. Note: Before you can enable the Poll command, you must configure the EOM and Handshake commands. Syntax: YRn.data where n is: 1 2 3 4

COM1 serial port COM2 serial port (246X and 248X terminals only) COM3 serial port (242X terminals only) COM4 serial port (242X, 2455, and 248X terminals only)

An acceptable value for data is any ASCII character. Disabled Enabled Default:

No characters, no polling \x1C (hexadecimal value for FS, File Separator)

No characters (Disabled)

Menu System: Main Menu > Configuration Menu > Communications Menu > Serial Port Bar Codes: To disable poll, scan one of these bar codes: Disable Poll for COM1

*$+YR1.*

Disable Poll for COM2

*$+YR2.*

*$+YR1.*

*$+YR2.*

Disable Poll for COM3

Disable Poll for COM4

*$+YR3.* *$+YR3.*

*$+YR4.*

*$+YR4.*

Or: To enable poll, scan one of these bar codes: Note: To scan these bar code labels, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” on page 146. Enable Poll (Set to FS) for COM1

*/D/KYR1/N%B* *$+YR1.%B*

Enable Poll (Set to FS) for COM2

*/D/KYR2/N%B* *$+YR2.%B* 218

Trakker Antares 2400 Family System Manual

Page 239

Chapter 6 - Configuration Command Reference Enable Poll (Set to FS) for COM3

*/D/KYR3/N%B* *$+YR3.%B*

Enable Poll (Set to FS) for COM4

*/D/KYR4/N%B* *$+YR4.%B*

Note: FS is encoded as %B in a Code 39 bar code label.

Postamble Terminals: All Trakker Antares terminals. Description: Sets the postamble that is appended to any data you scan with the terminal. Common postambles include cursor controls such as a tab or a carriage return line feed. You can set the postamble to use characters from the extended ASCII character set such as the Field Exit code for 5250 TE. However, you cannot scan in extended ASCII characters in the Postamble command. You must use the TRAKKER Antares 2400 Menu System. For help, see “Entering ASCII Control Characters” in the configuration chapter in your user’s manual. Syntax: AEdata Acceptable values for data are up to 25 ASCII characters. If you are entering quotation marks as data or grouping configuration commands, you must enclose the data within quotation marks (see the example). Note: To scan a bar code label that includes quotes, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” on page 146. Default:

No characters (Disabled)

Menu System: Main Menu > Configuration Menu > Terminal Menu > Preamble/Postamble Bar Codes: To disable the postamble, scan this bar code: Disable Postamble

*$+AE* *$+AE*

Trakker Antares 2400 Family System Manual

219

Page 240

Chapter 6 - Configuration Command Reference

Or: To set the postamble to an ASCII character string: Note: To set this command using the bar code labels from the “Full ASCII Bar Code Chart” on page 284, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” on page 146. 1 Scan this bar code: Enter Accumulate Mode / Set Postamble

*+/$+AE*

*+/$+AE*

2 Scan a value for data from the “Full ASCII Bar Code Chart” on page 284. The postamble can be from 1 to 25 characters. 3 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

Example:

You want to set a postamble that includes quotation marks. Enter the postamble by scanning this full ASCII bar code label: Set Postamble to “B”

*/D/KAE/B/B/BB/B/B/B* *$+AE"""B"""*

You must enclose the data within quotation marks and precede each quotation mark with another quotation mark so that the quotation marks are not treated as the end of the data.

Power Management Terminals: 2415, 2425, 2435, 2455, 2475, and 2485/6 with 802.11b radios. Description: Determines if power management is enabled for the radio. If you use enhanced or standard power management, the radio conserves power by sleeping between messages. Using standard power management decreases the performance of the RF network, but it increases the life of batterypowered devices. Using enhanced power management increases the performance of the RF network, but it decreases the life of batterypowered devices.

220

Trakker Antares 2400 Family System Manual

Page 241

Chapter 6 - Configuration Command Reference

Syntax: LHdata Acceptable values for data are: 0 1 2 Default:

Disabled Enhanced Standard

Enhanced

Menu System: Main Menu > Configuration Menu > Communications Menu > Radio Bar Codes: Scan one of these bar codes: Disable Power Management

Enable Enhanced Power Management

*$+LH0*

*$+LH1*

*$+LH0*

*$+LH1*

Enable Standard Power Management

*$+LH2* *$+LH2*

Preamble Terminals: All Trakker Antares terminals. Description: Sets the preamble that precedes any data you scan with the terminal. Common preambles include a data location number or an operator number. You can set the preamble to use characters from the extended ASCII character set. However, you cannot scan in extended ASCII characters in the Preamble command. You must use the TRAKKER Antares 2400 Menu System. For help, see “Entering ASCII Control Characters” in the configuration chapter in your user’s manual. Syntax: ADdata Acceptable values for data are up to 25 ASCII characters. If you are entering quotation marks as data or grouping configuration commands, you need to enclose the data within quotation marks (see the example). Note: To scan a bar code label that includes quotes, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” on page 146. Default:

No characters (Disabled)

Menu System: Main Menu > Configuration Menu > Terminal Menu > Preamble/Postamble

Trakker Antares 2400 Family System Manual

221

Page 242

Chapter 6 - Configuration Command Reference

Bar Codes: To disable the preamble, scan this bar code: Disable Preamble

*$+AD* *$+AD*

Or: To set the preamble to an ASCII character string: Note: To set this command using the bar code labels from the “Full ASCII Bar Code Chart” on page 284, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” on page 146. 1 Scan this bar code: Enter Accumulate Mode / Set Preamble

*+/$+AD*

*+/$+AD*

2 Scan a value for data from the “Full ASCII Bar Code Chart” on page 284. The preamble can be from 1 to 25 characters. 3 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

Example:

You want to set a preamble that includes quotation marks. Enter the preamble by scanning this full ASCII bar code label: Set Preamble to “B”

*/D/KAD/B/B/BB/B/B/B* *$+AD"""B"""*

You must enclose the data within quotation marks and precede each quotation mark with another quotation mark so that the quotation marks are not treated as the end of the data.

Radio MAC Address Terminals: 2415, 2425, 2435, 2455, 2475, and 2485/6. Description: Returns the MAC address of the radio that is installed in the RF terminal. You can only use this read-only command in an application to return the value (MAC address) to the application. Syntax: RI Default:

222

None

Trakker Antares 2400 Family System Manual