Page 223

Chapter 6 - Configuration Command Reference

Or: To set the maximum retries: 1 Scan this bar code: Enter Accumulate Mode / Set Maximum Retries

*+/$+NR*

*+/$+NR*

2 Scan a numeric value for data from these bar codes:

*0*

*0*

*2*

*2*

*4*

*4*

*6*

*1*

*1*

*3*

*3*

*5*

*5*

*7*

*6*

*7*

*8*

*9*

*8*

*9*

3 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

Maximum Sleep Duration Terminals: 2415, 2425, 2435, 2455, 2475, and 2485/6 with 802.11b radios. Description: Specifies the maximum amount of time the radio is allowed to sleep. Note: Before you set the maximum sleep duration, you must enable the Power Management command. Syntax: LIdata Acceptable values for data are from 0 to 65535 ms. Default:

100 ms

Menu System: Main Menu > Configuration Menu > Communications Menu > Radio Bar Codes: To set the default maximum sleep duration, scan this bar code: Default Maximum Sleep Duration

*$+LI100* *$+LI100*

Trakker Antares 2400 Family System Manual

203

Page 224

Chapter 6 - Configuration Command Reference

Or: To set the maximum sleep duration: 1 Scan this bar code: Enter Accumulate Mode / Set Maximum Sleep Duration

*+/$+LI*

*+/$+LI*

2 Scan a numeric value for data from these bar codes:

*0*

*0*

*2*

*2*

*4*

*4*

*6*

*1*

*1*

*3*

*3*

*5*

*5*

*7*

*6*

*7*

*8*

*9*

*8*

*9*

3 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

Medium Reservation Terminals: 2415, 2425, 2435, 2455, 2475, and 2485/6 with 802.11b radios. Description: Determines if the terminal uses medium reservation (RTS/CTS). You should enable this parameter if your network has hidden stations. When you enable this parameter, you also need to set the Reservation Threshold command. You may want to disable this parameter to improve network response time if the terminal usually sends very small packets and the network does not have any hidden stations. Syntax: LCdata Acceptable values for data are: 0 1 Default:

Disabled Enabled

Enabled

Menu System: Main Menu > Configuration Menu > Communications Menu > Radio Bar Codes: Scan one of these bar codes: 204

Trakker Antares 2400 Family System Manual

Page 225

Chapter 6 - Configuration Command Reference Disable Medium Reservation

*$+LC0* *$+LC0*

Enable Medium Reservation

*$+LC1*

*$+LC1*

Microwave Robustness Terminals: 2415, 2425, 2435, 2455, 2475, and 2485/6 with 802.11b radios. Description: Modifies the transmit rate so it does not permanently fall back to a slower rate. You should enable this command when you are operating the terminal in a room that contains microwave ovens. Syntax: LQdata Acceptable values for data are: 0 1 Default:

Disabled Enabled

Disabled

Menu System: Main Menu > Configuration Menu > Communications Menu > Radio Bar Codes: Scan one of these bar codes: Disable Microwave Robustness

*$+LQ0* *$+LQ0*

Enable Microwave Robustness

*$+LQ1*

*$+LQ1*

Modem Dial Sequence Terminals: 2420 with modem option. Description: Defines the dialing sequence that is used when the terminal establishes a modem connection. Syntax: YD3.data where data can be up to 25 characters from this table. Characters for Modem Dial Sequence Character 0-9

Description DTMF digits 0 through 9

A-D

DTMF letters A through D

*

The star digit (tone dialing only)

#

The gate digit (tone dialing only)

W

Wait for dial tone

@

Wait for silence

Trakker Antares 2400 Family System Manual

205

Page 226

Chapter 6 - Configuration Command Reference

Characters for Modem Dial Sequence (continued)

Default:

Character &

Description Wait for credit card dialing tone

,

Pause

(

Ignored. You can use this character to format the dial sequence.

)

Ignored. You can use this character to format the dial sequence.

-

Ignored. You can use this character to format the dial sequence.

.

Ignored. You can use this character to format the dial sequence.

<space>

Ignored. You can use this character to format the dial sequence.

0 (no dial sequence)

Menu System: Not supported Bar Codes: To set the default modem dial sequence, scan this bar code: Default Modem Dial Sequence

*$+YD3* *$+YD3*

Or: To set the modem dial sequence for COM3: Note: To set this command using the bar code labels from the “Full ASCII Bar Code Chart” on page 284, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” on page 146. 1 Scan this bar code: Enter Accumulate Mode / Set Modem Dial Sequence

*+/$+YD3*

*+/$+YD3*

2 Scan a value for data from the “Full ASCII Bar Code Chart” on page 284. The modem dial sequence can be from 1 to 25 characters. 3 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

Modem Initialization Sequence Terminals: 2420 with modem option. Description: Defines an initialization string that the terminal sends to the modem before the modem dial sequence.

206

Trakker Antares 2400 Family System Manual

Page 227

Chapter 6 - Configuration Command Reference

Syntax: YM3.data where data can be up to 25 characters from this table. Characters for Modem Initialization Sequence Character 0-9

Default:

Description DTMF digits 0 through 9

A-D

DTMF letters A through D

*

The star digit (tone dialing only)

#

The gate digit (tone dialing only)

W

Wait for dial tone

@

Wait for silence

&

Wait for credit card dialing tone

,

Pause

(

Ignored. You can use this character to format the dial sequence.

)

Ignored. You can use this character to format the dial sequence.

-

Ignored. You can use this character to format the dial sequence.

.

Ignored. You can use this character to format the dial sequence.

<space>

Ignored. You can use this character to format the dial sequence.

0 (auto rate)

Menu System: Main Menu > Configuration Menu > Communications Menu > Serial Port [COM3] Bar Codes: To set the default modem initialization sequence, scan this bar code: Default Modem Initialization Sequence

*$+YM3* *$+YM3*

Or: To set the modem dial sequence for COM3: Note: To set this command using the bar code labels from the “Full ASCII Bar Code Chart” on page 284, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” on page 146. 1 Scan this bar code: Enter Accumulate Mode / Set Modem Initialization Sequence

*+/$+YM3*

*+/$+YM3*

2 Scan a value for data from the “Full ASCII Bar Code Chart” on page 284. The modem dial sequence can be from 1 to 25 characters.

Trakker Antares 2400 Family System Manual

207

Page 228

Chapter 6 - Configuration Command Reference

3 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

MSI Terminals: All Trakker Antares terminals. Description: Enables or disables decoding of MSI symbology. MSI code is similar to Plessey code in that it includes a start pattern, data characters, one or two check digits, and a stop pattern. Syntax: CNdata Acceptable values for data are up to two digits:

Default:

Digit 1:

0 1 2 3

Disabled No check digits 1 modulus 10 check digit 2 modulus 10 check digit

Digit 2:

0 1

Discard check digit Transmit check digit

Disabled

Menu System: Main Menu > Configuration Menu > Symbologies Menu Bar Codes: Scan one of these bar codes: Disable MSI

*$+CN00*

*$+CN21*

*$+CN00*

*$+CN21*

MSI Without Check Digits

MSI With 2 Modulus 10 Check Digits, Discard Check Digits

*$+CN10*

*$+CN30*

*$+CN10*

*$+CN30*

MSI With 1 Modulus 10 Check Digit, Discard Check Digit

MSI With 2 Modulus 10 Check Digits, Transmit Check Digits

*$+CN20* *$+CN20*

208

MSI With 1 Modulus 10 Check Digit, Transmit Check Digit

*$+CN31*

*$+CN31*

Trakker Antares 2400 Family System Manual

Page 229

Chapter 6 - Configuration Command Reference

Multi-Drop Address Terminals: 2460 and 248X with enhanced I/O board option. Description: Defines the address of the communications port when you are using Multi-Drop protocol on COM2. Each multi-drop address has unique POL and SEL characters that are automatically set when you configure the address. The POL and SEL combination for each address is listed in the next table. POL and SEL Characters for Multi-Drop Addresses Address A

POL FS

SEL GS

Address Q

POL <

SEL =

B

RS

US

R

>

?

C

SP

!

S

@

A

D

“

#

T

B

C

E

$

%

U

D

E

F

&

‘

V

F

G

G

(

)

W

H

I

H

*

+

X

J

K

I

‘

-

Y

L

M

J

.

/

Z

N

O

K

0

1

0

P

Q

L

2

3

1

R

S

M

4

5

2

T

U

N

6

7

3

V

W

O

8

9

4

X

Y

P

:

;

Syntax: YN2.data where data can be an alphanumeric value from A through Z or 0 to 5. Default:

A

Menu System: Main Menu > Configuration Menu > Communications Menu > Serial Port [COM2] Bar Codes: To set the default multi-drop address: Default Multi-Drop Address (A) for COM2

*$+YN2.A* *$+YN2.A*

Trakker Antares 2400 Family System Manual

209

Page 230

Chapter 6 - Configuration Command Reference

Or: To set the multi-drop address: Note: To set this command using the bar code labels from the “Full ASCII Bar Code Chart” on page 284, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” on page 146. 1 Scan this bar code: Enter Accumulate Mode / Set Multi-Drop Address

*+/$+YN2.*

*+/$+YN2.*

2 Scan a value for data from the “Full ASCII Bar Code Chart” on page 284. The address is a single alphanumeric character from A through Z or 0 to 5. 3 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

Network Activate Terminals: 2415, 2425, 2435, 2455, 2461, 2475, 2480/1 with the Ethernet option, and 2485/6. Description: Enables or disables network communications between the terminal and other devices in the RF or Ethernet network. On a terminal with an Ethernet card, the Network Activate command disables or enables Ethernet communications. On an RF terminal, the Network Activate command disables or enables RF communications. When you enable this parameter, the terminal attempts to establish communications with the Intermec Gateway, DCS 30X, or host computer. You must enable this parameter for RF or Ethernet data collection. When you disable this parameter, the network is disabled and no RF or Ethernet communications are provided. On an RF terminal, the radio is turned off. Note: Unless you are operating your terminal in a DHCP or WTP environment, you need to set the Terminal IP Address command and either the Host IP Address or the Controller IP Address command before enabling the RF or Ethernet network. Syntax: NAdata Acceptable values for data are: 0 1 210

Disabled RF or Ethernet network (enabled) Trakker Antares 2400 Family System Manual

Page 231

Chapter 6 - Configuration Command Reference

Default:

Disabled

Menu System: Main Menu > Configuration Menu > Communications Menu > Primary Network Bar Codes: Scan one of these bar codes: Disable Network Activate

*$+NA0* *$+NA0*

Enable RF or Ethernet Network

*$+NA1*

*$+NA1*

Network Loopback Terminals: 2415, 2425, 2435, 2455, 2475, and 2485/6. Description: Transmits all messages received from the Intermec Gateway or DCS 30X back to the Intermec Gateway or DCS 30X. Messages received by the radio are not passed on to the terminal applications unless they are configuration commands. Messages continue to be looped back to the Intermec Gateway or DCS 30X as long as this feature is enabled. Messages originating from the terminal are still transmitted to the Intermec Gateway or DCS 30X. Use the Network Loopback parameter to troubleshoot RF or Ethernet communications problems. Syntax: NLdata Acceptable values for data are: 0 1 Default:

Disabled Enabled

Disabled

Menu System: Main Menu > Configuration Menu > Communications Menu > Advanced Network Bar Codes: Scan one of these bar codes: Disable Network Loopback

Enable Network Loopback

*$+NL0*

*$+NL1*

*$+NL0*

*$+NL1*

Network Name Terminals: 2415, 2425, 2435, 2455, 2475, and 2485/6 with 802.11b radios. Description: Defines an RF subnetwork. To communicate, all access points and RF terminals in the subnetwork must have the same network name, which is case-sensitive. If you set this parameter to “ANY,” the terminal can Trakker Antares 2400 Family System Manual

211

Page 232

Chapter 6 - Configuration Command Reference associate with any access point, regardless of the access point network name. You can roam between access points as long as all of the RF devices have the same network name. You can also create subnetworks in the same area by assigning different network names to terminals and access points. Syntax: LAdata Acceptable values for data are up to 32 ASCII characters. Default:

INTERMEC

Menu System: Main Menu > Configuration Menu > Communications Menu > Radio Bar Codes: To set the default network name, scan this bar code: Default Network Name

*$+LAINTERMEC* *$+LAINTERMEC*

Or: To set the network name to “ANY,” scan this bar code label: Set Network Name to ANY

*$+LAANY* *$+LAANY*

Or: To set the network name to an ASCII character string: Note: To set this command using the bar code labels from the “Full ASCII Bar Code Chart” on page 284, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” on page 146. 1 Scan this bar code: Enter Accumulate Mode / Set Network Name

*+/$+LA*

*+/$+LA*

2 Scan a value for data from the “Full ASCII Bar Code Chart” on page 284. The network name can be from 1 to 32 characters. 3 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

212

Trakker Antares 2400 Family System Manual