Page 213
Chapter 6 - Configuration Command Reference
*8*
*8*
*9*
*9*
3 Scan this bar code: . (Period)
*.*
*.*
4 Repeat Steps 2 and 3 to set the next three numbers in the host IP address field. After you scan the last address segment, go to Step 5. Do not scan the period after the last address segment. 5 Scan this bar code: Exit Accumulate Mode
*-/*
*-/*
ICMP (Internet Control Message Protocol) Terminals: 2415, 2425, 2435, 2455, 2475, and 2485/6. Description: Enables or disables ICMP messages sent from the terminal. Syntax: NZdata Acceptable values for data are: 0 1 Default:
Disable ICMP messages Enable ICMP messages
Enabled
Menu System: Not supported Bar Codes: Scan one of these bar codes: Disable ICMP Messages
*$+NZ0* *$+NZ0*
Enable ICMP Messages
*$+NZ1*
*$+NZ1*
Inactivity Timeout Terminals: 2415, 2425, 2435, 2455, 2475, and 2485/6 with OpenAir radios. Description: Defines the amount of time the radio on the terminal waits to go into a low power state. If no data is sent or received within the inactivity timeout period set, the radio goes into a low power state to conserve power. If you set a high value, the radio stays on longer at a higher power rate and uses power at a faster rate.
Trakker Antares 2400 Family System Manual
193
Page 214
Chapter 6 - Configuration Command Reference
Power Management Tip: Intermec strongly recommends that you use the optimum inactivity timeout of 5 seconds to preserve power. Syntax: RYdata Acceptable values for data are: 0 1-51
Radio never turns off Inactivity timeout in seconds multiplied by a value of 5 where data=1 sets a timeout delay of 5 seconds, data=2 sets a timeout delay of 10 seconds, and so on, up to data=51 for a timeout delay of 255 seconds. Default:
5 seconds
Menu System: Main Menu > Configuration Menu > Communications Menu > Radio Bar Codes: To set the default inactivity timeout to 5 seconds, scan this bar code: Default Inactivity Timeout
*$+RY1* *$+RY1*
Or: To set the inactivity timeout: 1 Scan this bar code: Enter Accumulate Mode / Set Inactivity Timeout
*+/$+RY*
*+/$+RY*
2 Scan a numeric value for data from these bar codes:
*0*
*0*
*2*
*2*
*4*
*4*
*6*
*6*
*8*
*8*
*1*
*1*
*3*
*3*
*5*
*5*
*7*
*7*
*9*
*9*
3 Scan this bar code: Exit Accumulate Mode
*-/*
*-/*
194
Trakker Antares 2400 Family System Manual
Page 215
Chapter 6 - Configuration Command Reference
Interleaved 2 of 5 Terminals: All Trakker Antares terminals. Description: Enables or disables decoding of Interleaved 2 of 5 (I 2 of 5) symbology. I 2 of 5 is a high-density, self-checking, continuous numeric symbology. It is mainly used in inventory distribution and the automobile industry. Enabling I 2 of 5 automatically disables Code 2 of 5. Syntax: CAdata Acceptable values for data are: 0 2-32 95 96 97 98 99
Disabled Fixed length (even number only) Case code (6 or 14) with check digit verified but discarded Variable length with check digit verified but discarded Variable length without a check digit Case code (6 or 14) with a check digit Variable length with a check digit
Using the variable length without a check digit configuration option can cause substitution errors. Attention: Des erreurs de substitution peuvent survenir si vous utilisez la longueur variable sans option de vérification de configuration de chiffres. Default:
Disabled
Menu System: Main Menu > Configuration Menu > Symbologies Menu > 2 of 5/I 2 of 5 Bar Codes: Scan one of these bar codes: Disable Interleaved 2 of 5
*$+CA0* *$+CA0*
Enable Case Code With Check Digit Verified But Discarded
*$+CA95*
*$+CA95*
Enable Variable Length With Check DigitEnable Variable Length Without Verified But Discarded a Check Digit
*$+CA96* *$+CA96*
*$+CA97*
*$+CA97*
Enable Variable Length With a Check Digit Enable Case Code With a Check Digit
*$+CA99* *$+CA99*
Trakker Antares 2400 Family System Manual
*$+CA98*
*$+CA98*
195
Page 216
Chapter 6 - Configuration Command Reference
Or: To set Interleaved 2 of 5 to a fixed length: 1 Scan this bar code: Enter Accumulate Mode / Set Fixed Length
*+/$+CA*
*+/$+CA*
2 Scan a numeric value for data from these bar codes. (Use even numbers 2-32 only.)
*0*
*0*
*2*
*2*
*4*
*4*
*1*
*1*
*3*
*3*
*6*
*6*
*8*
*8*
3 Scan this bar code: Exit Accumulate Mode
*-/*
*-/*
Keypad Caps Lock Terminals: All Trakker Antares terminals. Description: Turns the caps lock on and off. With the caps lock turned on, all alphabetic characters you type on the keypad will be uppercase or capital letters. Syntax: KAdata Acceptable values for data are: 0 1 Default:
Caps lock off Caps lock on
Caps lock off
Menu System: Main Menu > Configuration Menu > Terminal Menu > Keypad Bar Codes: Scan one of these bar codes: Caps Lock Off
*$+KA0* *$+KA0*
196
Caps Lock On
*$+KA1*
*$+KA1*
Trakker Antares 2400 Family System Manual
Page 217
Chapter 6 - Configuration Command Reference
Keypad Clicker Terminals: All Trakker Antares terminals. Description: Enables or disables the keypad clicker. The terminal sounds a click each time you press a key or decode a row of a two-dimensional symbology. Note: If the Beep Volume command is set to off, you will not hear any audio signals including the keyclick. Syntax: KCdata Acceptable values for data are: 0 1 Default:
Disable keypad clicker Enable keypad clicker
Enabled
Menu System: Main Menu > Configuration Menu > Terminal Menu > Keypad Bar Codes: Scan one of these bar codes: Disable Keypad Clicker
*$+KC0* *$+KC0*
Enable Keypad Clicker
*$+KC1*
*$+KC1*
Keypad Control Terminals: All Trakker Antares terminals. Description: Enables or disables the keypad. When you disable the keypad, you cannot use the keypad to enter information into the terminal. Syntax: KEdata Acceptable values for data are: 0 1 Default:
Disable keypad Enable keypad
Enabled
Menu System: Not supported Bar Codes: Scan one of these bar codes: Disable Keypad
Enable Keypad
*$+KE0*
*$+KE1*
*$+KE0*
Trakker Antares 2400 Family System Manual
*$+KE1*
197
Page 218
Chapter 6 - Configuration Command Reference
Keypad Type Terminals: 241X, 242X, 243X, 2455, 2475, and 248X. Description: The keypad type is initially configured in the terminal’s firmware at the Intermec factory. If you change the keypad overlay, you need to configure the keypad type to match the new keypad overlay. Important: After you change the keypad type, you must save the configuration in flash memory and boot the terminal for the change to take effect. Note: With the English alphanumeric, programmable, or international keypads, you can access all the characters in the “Trakker Antares Terminal Font Set” on page 290. Syntax: KTdata where acceptable values for data are listed in the next table. Keypad Type: Acceptable Values for Data Value 0
Description Hardware (factory) default, 241X, 242X, 243X, 2455, 2475, 248X
Value E
Description Programmable with backspace key, 242X
1
Terminal emulation keypad, 242X
F
English ABCD keypad, 2455
2
Programmable (English or European) keypad, 242X
G
IBM 5250 TE keypad, 2455
3
English alphanumeric keypad, 2475, 248X
H
IBM 3270 TE keypad, 2455
4
5250 terminal emulation keypad, 2475, 248X
I
VT/ANSI TE keypad, 2455
5
3270 terminal emulation keypad, 2475, 248X
J
European keypad, 2455
6
VT/ANSI terminal emulation keypad, 2475, 248X
K
AT compatible 1, 2455, 246X
7
Numeric keypad (oversized function numeric or Time and Attendance), 248X
L
Programmable/international, 55-key keypad, 241X
8
French alphanumeric keypad, 2475, 248X
M
Terminal emulation, 55-key keypad, 241X
9
Italian alphanumeric keypad, 2475, 248X
N
TE 2000 function numeric, 39-key keypad, 243X
A
Spanish alphanumeric keypad, 2475, 248X
P
Programmable, 37-key (Alphanumeric w/large numeric) keypad, 241X
B
German alphanumeric keypad, 2475, 248X
Q
Terminal emulation 37-key (Alphanumeric w/large numeric) keypad, 241X
C
Portuguese alphanumeric keypad, 2475, 248X
R
International, 37-key (Alphanumeric w/large numeric) keypad, 241X
D
Terminal emulation with backspace key, 242X
S
Programmable, 37-key (Function key w/large numeric) keypad, 241X
198
Trakker Antares 2400 Family System Manual
Page 219
Chapter 6 - Configuration Command Reference
Keypad Type: Acceptable Values for Data (continued) Value T
Description Terminal emulation 37-key (Function key w/large numeric) keypad, 241X
Value X
Description TE 2000 alphanumeric, 57-key keypad, 243X
U
International, 37-key (Function key w/large numeric) keypad, 241X
Y
U.S. English function numeric, 39-key keypad, 243X
V
U.S. English alphanumeric, 57-key keypad, 243X
Z
International function numeric, 39-key keypad, 243X
W
International alphanumeric, 57-key keypad, 243X
V
U.S. English alphanumeric, 57-key keypad, 243X
Default:
Hardware Default
Menu System: Main Menu > Configuration Menu > Terminal Menu > Keypad Bar Codes: To set keypad type: 1 Scan one of these bar codes: Set Keypad Type to Hardware Default
*$+KT0*
Set Keypad Type to Terminal Emulation, 242X
*$+KT1*
*$+KT0*
*$+KT1*
Set Keypad Type to Programmable, 242X
Set Keypad Type to English, 2475, 248X
*$+KT2*
*$+KT3*
*$+KT2*
*$+KT3*
Set Keypad Type to 5250 TE, 2475, 248X
Set Keypad Type to 3270 TE, 2475, 248X
*$+KT4*
*$+KT5*
*$+KT4*
*$+KT5*
Set Keypad Type to VT/ANSI, 2475, 248X
Set Keypad Type to Numeric, 248X
*$+KT6*
*$+KT7*
*$+KT6*
*$+KT7*
Set Keypad Type to French Alphanumeric, 2475, 248X
Set Keypad Type to Italian Alphanumeric, 2475, 248X
*$+KT8*
*$+KT9*
*$+KT8*
*$+KT9*
Set Keypad Type to Spanish Alphanumeric, 2475, 248X
Set Keypad Type to German Alphanumeric, 2475, 248X
*$+KTA*
*$+KTB*
*$+KTA*
Trakker Antares 2400 Family System Manual
*$+KTB*
199
Page 220
Chapter 6 - Configuration Command Reference Set Keypad Type to Portuguese Alphanumeric, 2475, 248X
Set Keypad Type to Terminal Emulation with Backspace Key, 242X
*$+KTC*
*$+KTD*
Set Keypad Type to Programmable with Backspace Key, 242X
Set Keypad Type to English ABCD, 2455
*$+KTE*
*$+KTF*
Set Keypad Type to IBM 5250 TE, 2455
Set Keypad Type to IBM 3270 TE, 2455
*$+KTC*
*$+KTD*
*$+KTE*
*$+KTF*
*$+KTG*
*$+KTH*
*$+KTG*
*$+KTH*
Set Keypad Type to VT/ANSI TE, 2455
Set Keypad Type to European, 2455
*$+KTI*
*$+KTJ*
*$+KTI*
*$+KTJ*
Set Keypad Type to Programmable / International, 55-key, 241X
Set Keypad Type to Terminal emulation, 55-key, 241X
*$+KTL*
*$+KTM*
Set Keypad Type to TE 2000 function numeric, 39-key keypad, 243X
Set Keypad Type to Programmable, 37-key (Alphanumeric w/large numeric), 241X
*$+KTN*
*$+KTP*
Set Keypad Type to TE 2000, 37-key (Alphanumeric w/large numeric), 241X
Set Keypad Type to International, 37-key (Alphanumeric w/large numeric), 241X
*$+KTQ*
*$+KTR*
Set Keypad Type to Programmable, 37-key (Function key w/large numeric), 241X
Set Keypad Type to TE 2000, (Function key w/large numeric), 241X
*$+KTL*
*$+KTM*
*$+KTN*
*$+KTP*
*$+KTQ*
*$+KTR*
*$+KTS*
*$+KTT*
Set Keypad Type to International, 37-key (Function key w/large numeric), 241X
Set Keypad Type to U.S. English alphanumeric, 57-key keypad, 243X
*$+KTU*
*$+KTV*
*$+KTU*
200
*$+KTT*
*$+KTS*
*$+KTV*
Trakker Antares 2400 Family System Manual
Page 221
Chapter 6 - Configuration Command Reference Set Keypad Type to International alphanumeric, 57-key keypad, 243X
Set Keypad Type to TE 2000 alphanumeric, 57-key keypad, 243X
*$+KTW*
*$+KTX*
Set Keypad Type to U.S. English function numeric, 39-key keypad, 243X
Set Keypad Type to International function numeric, 39-key keypad, 243X
*$+KTW*
*$+KTY*
*$+KTY*
*$+KTX*
*$+KTZ*
*$+KTZ*
2 Scan this bar code to save the configuration change in flash memory: Save Configuration in Flash Memory
*.+1*
*.+1*
3 Scan this bar code to boot the terminal and use the new keypad type: Reset Firmware
*-.*
*-.*
LRC (Longitudinal Redundancy Check) Terminals: All Trakker Antares terminals. Description: The LRC character is an error-checking character that you can append to transmitted and received blocks of data. You can configure LRC for the Configurable communications protocol. For more information, see the networking chapter in your user’s manual. Note: Before you can enable LRC, you must configure the EOM command. Syntax: YFn.data where n is: 1 2 3 4
COM1 serial port COM2 serial port (246X and 248X terminals only) COM3 serial port (242X terminals only) COM4 serial port (242X, 2455, and 248X terminals only)
Acceptable values for data are: 0 1 Default:
LRC disabled LRC enabled
Disabled
Trakker Antares 2400 Family System Manual
201
Page 222
Chapter 6 - Configuration Command Reference
Menu System: Main Menu > Configuration Menu > Communications Menu > Serial Port Bar Codes: To disable LRC, scan one of these bar codes: Disable LRC for COM1
Disable LRC for COM2
*$+YF1.0*
*$+YF2.0*
*$+YF1.0*
*$+YF2.0*
Disable LRC for COM3
Disable LRC for COM4
*$+YF3.0*
*$+YF4.0*
*$+YF3.0*
*$+YF4.0*
Or: To enable LRC, scan one of these bar codes: Enable LRC for COM1
Enable LRC for COM2
*$+YF1.1*
*$+YF2.1*
*$+YF1.1*
*$+YF2.1*
Enable LRC for COM3
Enable LRC for COM4
*$+YF3.1*
*$+YF4.1*
*$+YF3.1*
*$+YF4.1*
Maximum Retries Terminals: 2415, 2425, 2435, 2455, 2475, and 2485/6. Description: Defines the number of times the terminal will attempt to send a disconnect request message to the Intermec Gateway or DCS 30X. The terminal sends connect and disconnect request messages to the Intermec Gateway or DCS 30X when you turn the terminal on and off. Tip: Intermec strongly recommends that you use the optimum setting of 7 retries. Syntax: NRdata Acceptable values for data are: 0 1-99 Default:
Terminal retries indefinitely Number of retries
7
Menu System: Main Menu > Configuration Menu > Communications Menu > Advanced Network Bar Codes: To set the default number of maximum retries, scan this bar code: Default Maximum Retries
*$+NR7* *$+NR7*
202
Trakker Antares 2400 Family System Manual