Trakker Antares 2400 Family System Manual: Chapter 6 - Configuration Command Reference, pages 203 to 212
Pages 203 to 212 of 362, from Trakker Antares 2400 Family System Manual
The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2410, Intermec 2415, Intermec 2435 and Intermec 2475
Page 203
Chapter 6 - Configuration Command Reference
Syntax: DNdata Acceptable values for data are: 0 1 2 3 4 Default:
Original Normal Inverse Nrm/Icon (243X only) Inv/Icon (243X only)
0 (Original)
Menu System: Main Menu > Configuration Menu > Terminal Menu > Display Bar Codes: Scan one of these bar codes: Original Display Video Mode
*$+DN0*
Normal Display Video Mode
*$+DN1*
*$+DN0*
*$+DN1*
Inverse Display Video Mode
Normal Display Video Mode with Icons
*$+DN2* *$+DN2*
*$+DN3*
*$+DN3*
Inverse Display Video Mode with Icons
*$+DN4* *$+DN4*
Domain Terminals: 2415, 2425, 2435, 2455, 2475, and 2485/6 with OpenAir radios. Description: Defines a logical partition or subnetwork of the RF network. To establish communications, you must assign the same domain number to every RF device in the subnetwork. You can roam between access points as long as all the RF devices have the same domain number. You can also assign different domain numbers if you want to establish different RF subnetworks in the same area. Syntax: RWdata Acceptable values for data are any number from 0 to 15. Default:
0
Menu System: Main Menu > Configuration Menu > Communications Menu > Radio Bar Codes: To set the default domain, scan this bar code: Default Domain
*$+RW0* *$+RW0*
Trakker Antares 2400 Family System Manual
183
Page 204
Chapter 6 - Configuration Command Reference
Or: To set a value for Domain: 1 Scan this bar code: Enter Accumulate Mode / Set Domain
*+/$+RW*
*+/$+RW*
2 Scan a numeric value for data from these bar codes:
*0*
*0*
*2*
*2*
*4*
*4*
*6*
*1*
*1*
*3*
*3*
*5*
*5*
*7*
*6*
*7*
*8*
*9*
*8*
*9*
3 Scan this bar code: Exit Accumulate Mode
*-/*
*-/*
End of Message (EOM) Terminals: All Trakker Antares terminals. Description: Attaches an EOM to the end of a data block to indicate the end of data transmission to and from a terminal. When EOM is disabled, the terminal communicates in Character mode. When EOM is enabled, the terminal communicates in Frame mode. You can configure EOM for the Configurable communications protocol. For more information, see the networking chapter in your user’s manual. You can set EOM to use characters from the extended ASCII character set using the TRAKKER Antares 2400 Menu System. This procedure is similar to the one for setting the preamble and postamble. For help, see “Entering ASCII Control Characters” in the configuration chapter in your user’s manual. You must configure a value for EOM before you can set these other serial communications commands: • Configuration Commands Via Serial Port • Handshake 184
Trakker Antares 2400 Family System Manual
Page 205
Chapter 6 - Configuration Command Reference
• LRC • Start of Message (SOM) Note: EOM cannot equal the same value as SOM, and EOM1 cannot equal the same value as EOM2. EOM cannot be set to these values: • AFF (ACK)
• REQ (ENQ)
• DLE
• SEL
• NEG (NAK)
• XOFF
• Poll
• XON
• RES (EOT) Syntax: YZn.data where n is: 1 2 3 4
COM1 serial port COM2 serial port (246X and 248X terminals only) COM3 serial port (242X terminals only) COM4 serial port (242X, 2455, and 248X terminals only)
Acceptable values for data are one or two ASCII characters. Default:
\x03 (hexadecimal value for ETX)
Menu System: Main Menu > Configuration Menu > Communications Menu > Serial Port Bar Codes: To disable EOM for each serial port, scan these bar codes: Disable EOM for COM1
Disable EOM for COM2
*$+YZ1.*
*$+YZ2.*
Disable EOM for COM3
Disable EOM for COM4
*$+YZ1.*
*$+YZ3.* *$+YZ3.*
*$+YZ2.*
*$+YZ4.*
*$+YZ4.*
Or: To set EOM to one or two ASCII characters for one serial port: Note: To set this command using the bar code labels from the “Full ASCII Bar Code Chart” on page 284, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” on page 146. 1 Scan this bar code: Enter Accumulate Mode / Set EOM
*/K/O/D/KYZ*
*+/$+YZ*
Trakker Antares 2400 Family System Manual
185
Page 206
Chapter 6 - Configuration Command Reference
2 Scan the serial port from these bar codes: COM1
*1/N*
COM2
*2/N*
*1.*
*2.*
COM3
COM4
*3/N*
*4/N*
*3.*
*4.*
3 Scan one or two bar codes for data from the “Full ASCII Bar Code Chart” on page 284. 4 Scan this bar code: Exit Accumulate Mode
*/M/O*
*-/*
5 Repeat Steps 2 through 4 to set EOM for another serial port.
Flash Memory Configuration Terminals: All Trakker Antares terminals. Description: Configures the use of the optional 2MB extended flash memory. If you have a terminal with the 4MB flash memory option, you can either configure the extra 2MB of flash memory as a drive D, or you can use it to store double-byte fonts. You cannot use the space for both. If you configure the flash memory as drive D, use this drive to store large lookup tables and data files. You can store up to 128 files on drive D or store up to 2MB of double-byte fonts. After you configure the flash memory, you must save the configuration in flash memory and boot the terminal for the change to take effect. Note: The 4MB flash memory is required for 802.1x TTLS security. If you have the 802.1x TTLS security option, you cannot configure Flash Memory Configuration. For more information about configuring 802.1x TTLS security, see “Configuring 802.1x TTLS Security” in the networking chapter of your user’s manual. Syntax: FFdata Acceptable values for data are: 0 Configure flash memory for double-byte fonts 32 Configure flash memory as the 2MB drive D Default:
0 (Configure flash memory for double-byte fonts)
Menu System: Not supported 186
Trakker Antares 2400 Family System Manual
Page 207
Chapter 6 - Configuration Command Reference
Bar Codes: To set Flash Memory Configuration: 1 Scan one of these bar codes to configure flash memory: Configure Flash Memory For Double-Byte Fonts
*$+FF0*
*$+FF0*
Configure Flash Memory as Drive D
*$+FF32*
*$+FF32*
2 To save the changes in flash memory, scan this bar code: Save Configuration in Flash Memory
*.+1*
*.+1*
3 Scan this bar code to boot the terminal and use the 2MB flash memory to store double-byte fonts or as drive D: Reset Firmware
*-.*
*-.*
Note: When you boot or reset the terminal, any fonts or files in flash memory on drive D are erased. 4 If you configured flash memory to store double-byte fonts, use the Trakker Antares Font Editor to download the double-byte font set to the terminal. See your local Intermec sales representative for information about the Trakker Antares Font Editor.
Flow Control Terminals: All Trakker Antares terminals. Description: Regulates the data transmission through the serial port. The terminal is a DTE (Data Terminal Equipment) device. There are several flow control options: • CTS checking where Clear To Send (CTS) is a hardware signal flow control. The terminal sets and clears Request To Send (RTS) when it is ready to receive. The terminal checks CTS when it tries to transmit data. • XON/XOFF response causes the terminal to respond to XON/XOFF characters received while transmitting. • XON/XOFF control specifies that the terminal transmits XON/XOFF characters to control the incoming data flow. • XON/XOFF response and control specify that the terminal responds to and transmits XON/XOFF characters.
Trakker Antares 2400 Family System Manual
187
Page 208
Chapter 6 - Configuration Command Reference
• CTS/RTS for DTE-DTE allows for peer connections. Each terminal’s RTS output pin is connected to the CTS input pin of the other terminal. Each terminal sets RTS whenever it is ready to receive data and waits for CTS to be set before sending data. You can configure flow control for these communications protocols: Binary, Configurable, and Polling Mode D. For more information, see the networking chapter in your user’s manual. Syntax: YLn.data where n is: 1 2 3 4
COM1 serial port COM2 serial port (246X and 248X terminals only) COM3 serial port (242X terminals only) COM4 serial port (242X, 2455, and 248X terminals only)
Acceptable values for data are: 0 1 2 3 4 5 Default:
No flow control CTS checking XON/XOFF response XON/XOFF control XON/XOFF response and control CTS/RTS for DTE-DTE
0 (no flow control)
Menu System: Main Menu > Configuration Menu > Communications Menu > Serial Port Bar Codes: To set the default flow control for each serial port, scan these bar codes: No Flow Control for COM1
*$+YL1.0*
No Flow Control for COM2
*$+YL2.0*
*$+YL1.0*
*$+YL2.0*
No Flow Control for COM3
No Flow Control for COM4
*$+YL3.0* *$+YL3.0*
*$+YL4.0*
*$+YL4.0*
Or: To set the flow control for one serial port: 1 Scan this bar code: Enter Accumulate Mode / Set Flow Control
*+/$+YL*
*+/$+YL*
188
Trakker Antares 2400 Family System Manual
Page 209
Chapter 6 - Configuration Command Reference
2 Scan the serial port from these bar codes: COM1
*1.*
COM2
*2.*
*1.*
*2.*
COM3
COM4
*3.*
*3.*
*4.*
*4.*
3 Scan the flow control setting from these bar codes: No Flow Control
*0*
CTS Checking
*1*
*0*
*1*
XON/XOFF Response
XON/XOFF Control
*2*
*3*
*2*
*3*
XON/XOFF Response and Control
CTS/RTS for DTE-DTE
*4*
*4*
*5*
*5*
4 Scan this bar code: Exit Accumulate Mode
*-/*
*-/*
5 Repeat Steps 1 through 4 to set the flow control for another serial port.
GTIN Compliance Terminals: All Trakker Antares terminals. Description: Enables or disables GTIN (Global Trade Item Number) compliance. This command affects UPC/EAN and UCC/EAN Code 128 bar code symbologies.
Trakker Antares 2400 Family System Manual
189
Page 210
Chapter 6 - Configuration Command Reference
GTIN Compliance Bar Code Symbologies Symbology UPC/EAN
Description With GTIN Compliance enabled, two zeros are padded to the beginning of UPC-A, and one zero is padded to the beginning of EAN-13 to expand the numbers to 14 digits.
UCC/EAN Code 128
A GTIN compliant EAN 128 label: 1 is 16 digits long. 2 has “01” as the first two digits of the label. With GTIN Compliance enabled, a GTIN compliant EAN 128 label will have the first two digits stripped and output 14 digits.
Syntax: COdata Acceptable values for data are: 0 1 Default:
Disable GTIN compliance Enable GTIN compliance
Disabled
Menu System: Main Menu > Configuration Menu > Symbologies Menu > UPC/EAN Bar Codes: Scan one of these bar codes: Disable GTIN Compliance
*$+CO0* *$+CO0*
Enable GTIN Compliance
*$+CO1*
*$+CO1*
Handshake Terminals: All Trakker Antares terminals. Description: Enables or disables the handshake event that is an affirmative acknowledge to a message received through the serial port. You can configure handshake for the Configurable communications protocol. Before you can enable Handshake, you need to configure the EOM command. Handshake is also referred to as AFF (affirmative acknowledge) on other Intermec data collection devices. For more information, see the networking chapter in your user’s manual. Note: If you are using a decoded scanner, such as the 1551, Intermec strongly recommends that you enable Handshake.
190
Trakker Antares 2400 Family System Manual
Page 211
Chapter 6 - Configuration Command Reference
Syntax: YJn.data where n is: 1 2 3 4
COM1 serial port COM2 serial port (246X and 248X terminals only) COM3 serial port (242X terminals only) COM4 serial port (242X, 2455, and 248X terminals only)
An acceptable value for data is any ASCII character. Disabled Enabled Default:
No characters, no ACK or NAK transmitted \x06 (hexadecimal value for ACK)
No characters (Disabled)
Menu System: Main Menu > Configuration Menu > Communications Menu > Serial Port Bar Codes: To disable handshake, scan one of these bar codes: Note: To scan these bar code labels, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” on page 146. Disable Handshake for COM1
*$+YJ1.*
Disable Handshake for COM2
*$+YJ2.*
*$+YJ1.*
*$+YJ2.*
Disable Handshake for COM3
Disable Handshake for COM4
*$+YJ3.*
*$+YJ3.*
*$+YJ4.*
*$+YJ4.*
Or: To enable handshake, scan one of these bar codes: Enable Handshake (Set to ACK) for COM1
*/D/KYJ1/N$F*
*$+YJ1.$F*
Enable Handshake (Set to ACK) for COM2
*/D/KYJ2/N$F*
*$+YJ2.$F*
Enable Handshake (Set to ACK) for COM3
*/D/KYJ3/N$F*
*$+YJ3.$F*
Enable Handshake (Set to ACK) for COM4
*/D/KYJ4/N$F*
*$+YJ4.$F*
Trakker Antares 2400 Family System Manual
191
Page 212
Chapter 6 - Configuration Command Reference
Host IP Address Terminals: 2415, 2425, 2435, 2455, 2461, 2475, 2480/1 with the Ethernet option, and 2485/6 using the TCP/IP network. Description: Defines the IP address assigned to the host computer in your RF or Ethernet network. An IP address is a unique network level address you assign to each device in a TCP/IP direct connect network. The host IP address you set on the terminal must match the address that is set on the host. Syntax: NCn.n.n.n where each n address segment is a number from 0 to 255. The host IP address field consists of four separate numbers, each separated by a period. Note: The RF or Ethernet network cannot be activated if the first address segment in the IP address is set to 0, 127, or a number greater than 223. Default:
0.0.0.0
Menu System: Main Menu > Configuration Menu > Communications Menu > Primary Network Bar Codes: To set the default host IP address, scan this bar code: Default Host IP Address
*$+NC0.0.0.0* *$+NC0.0.0.0*
Or: To set the host IP address: 1 Scan this bar code: Enter Accumulate Mode / Set Host IP Address
*+/$+NC*
*+/$+NC*
2 Scan a numeric value from 0 to 255 to set an n field of the host IP address from these bar codes.
*0*
*0*
*2*
*2*
*4*
*4*
*6*
*6*
192
*1*
*1*
*3*
*3*
*5*
*5*
*7*
*7*
Trakker Antares 2400 Family System Manual