Page 273

Chapter 6 - Configuration Command Reference

Note: The RF or Ethernet network cannot be activated if the first address segment in the IP address is set to 127 or a number greater than 223. Default:

0.0.0.0 (DHCP enabled) Note: If you are using the TCP/IP network, the default terminal IP address enables the terminal as a DHCP client. For more information, see “DHCP (Terminal)” on page 174.

Menu System: Main Menu > Configuration Menu > Communications Menu > Primary Network Bar Codes: To set the default terminal IP address, scan this bar code: Default Terminal IP Address (DHCP enabled)

*$+ND0.0.0.0* *$+ND0.0.0.0*

Or: To set the terminal IP address: 1 Scan this bar code: Enter Accumulate Mode / Set Terminal IP Address

*+/$+ND*

*+/$+ND*

2 Scan a numeric value from 0 to 255 to set an n field of the terminal IP address from these bar codes.

*0*

*0*

*2*

*1*

*1*

*3*

*2*

*3*

*4*

*5*

*4*

*6*

*6*

*8*

*8*

*5*

*7*

*7*

*9*

*9*

3 Scan this bar code: . (Period)

*.*

*.*

4 Repeat Steps 2 and 3 to set the next three numbers in the terminal IP address field. After you scan the last address segment, go to Step 5. Do not scan the period after the last address segment. Trakker Antares 2400 Family System Manual

253

Page 274

Chapter 6 - Configuration Command Reference

5 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

Terminal Port Terminals: All Trakker Antares terminals using the TCP/IP network. Description: Sets the port used to open the default TCP/IP connection. Specifying a terminal port improves host communications by ensuring that host sessions are closed down when your terminal reboots. Syntax: NTdata Acceptable values for data are: 0 1000-65535 Default:

Source port value of zero, random terminal port used for TCP/IP connection Any value in this range except for 1778 and 6000.

0 (random terminal port used for TCP/IP connection)

Menu System: Main Menu > Configuration Menu > Communications Menu > Primary Network > Terminal Port Bar Codes: To set the default TCP/IP source port, scan this bar code: Default Terminal Port

*$+NT0* *$+NT0*

Or: To set the Terminal Port: 1 Scan this bar code: Enter Accumulate Mode / Set Terminal Port

*+/$+NT*

*+/$+NT*

2 Scan an acceptable numeric value from these bar codes to set the Terminal Port.

*0*

*1*

*2*

*3*

*2*

*4*

*4*

254

*1*

*0*

*3*

*5*

*5*

Trakker Antares 2400 Family System Manual

Page 275

Chapter 6 - Configuration Command Reference

*6*

*7*

*6*

*7*

*8*

*9*

*8*

*9*

3 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

Time and Date Terminals: All Trakker Antares terminals. Description: Sets the time and date on the terminal. Syntax: DBdata Acceptable values for data are 12 digits corresponding to: yy mm dd hh mm ss

00-99 01-12 01-31 00-23 00-59 00-59

Year Month of the year Day of the month Hour Minutes Seconds

Year values (yy) from 00 to 95 are interpreted as 2000 through 2095. Year values from 96 to 99 are interpreted as 1996 through 1999. Default:

The date of the most recent firmware installation or upgrade.

Menu System: Main Menu > System Menu Bar Codes: To set the time and date: 1 Scan this bar code: Enter Accumulate Mode / Set Time and Date

*+/$+DB*

*+/$+DB*

2 Scan a numeric value for each digit from these bar codes:

*0*

*0*

*2*

*2*

*4*

*4*

Trakker Antares 2400 Family System Manual

*1*

*1*

*3*

*3*

*5*

*5*

255

Page 276

Chapter 6 - Configuration Command Reference

*6*

*7*

*6*

*7*

*8*

*9*

*8*

*9*

3 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

Time in Seconds Terminals: All Trakker Antares terminals. Description: If you enable the Append Time command, you can enable the Time in Seconds command to append the seconds to each bar code label that is scanned into the terminal. To append the time in only hours and minutes, disable the Time in Seconds command. Syntax: DAdata Acceptable values for data are: 0 1 Default:

Disabled Enabled

Disabled

Menu System: Main Menu > Configuration Menu > Terminal Menu > Append Time Bar Codes: Scan one of these bar codes: Disable Time in Seconds

Enable Time in Seconds

*$+DA0*

*$+DA1*

*$+DA0*

*$+DA1*

Time Zone Terminals: All Trakker Antares terminals. Description: Sets the time zone on the terminal. Syntax: DZdata Acceptable values for data are any number from 0 to 23, where 0 represents Universal Time (UT). Default:

8 Pacific Standard Time (PST)

Menu System: Not supported 256

Trakker Antares 2400 Family System Manual

Page 277

Chapter 6 - Configuration Command Reference

Bar Codes: To set the default time zone, scan this bar code: Set Time Zone to Pacific Standard Time

*$+DZ8* *$+DZ8*

Or: To set the time zone: 1 Scan this bar code: Enter Accumulate Mode / Set Time Zone

*+/$+DZ*

*+/$+DZ*

2 Scan a numeric value from 0 to 23 from these bar codes:

*0*

*0*

*2*

*2*

*4*

*4*

*6*

*6*

*8*

*8*

*1*

*1*

*3*

*3*

*5*

*5*

*7*

*7*

*9*

*9*

3 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

Timeout Delay Terminals: All Trakker Antares terminals. Description: If handshaking is enabled, the terminal expects a response to each message that is sent to the host through a serial port. The timeout delay is the amount of time the terminal waits to receive a response. You can configure the timeout delay for the Configurable communications protocol. For more information, see the networking chapter in your user’s manual. When the timeout expires, the terminal tries to send the message again. If no response is received after the terminal tries to send the message three times, a timeout error occurs. In polling mode D, the terminal sends another poll sequence when it resends the message.

Trakker Antares 2400 Family System Manual

257

Page 278

Chapter 6 - Configuration Command Reference

Note: Before you can set Timeout Delay, you need to configure the EOM and Handshake commands. Syntax: YEn.data where n is: 1 2 3 4

COM1 serial port COM2 serial port (246X and 248X terminals only) COM3 serial port (242X terminals only) COM4 serial port (242X, 2455, and 248X terminals only)

Acceptable values for data are: 0 1 2 3 4 5 6 7 Default:

5 ms 100 ms 500 ms 2 sec 10 sec 20 sec 40 sec 60 sec

10 seconds

Menu System: Main Menu > Configuration Menu > Communications Menu > Serial Port Bar Codes: To set the default timeout delay, scan one of these bar codes: Timeout Delay 10 sec for COM1

Timeout Delay 10 sec for COM2

*$+YE1.4*

*$+YE2.4*

Timeout Delay 10 sec for COM3

Timeout Delay 10 sec for COM4

*$+YE1.4*

*$+YE3.4* *$+YE3.4*

*$+YE2.4*

*$+YE4.4*

*$+YE4.4*

Or: To set the timeout delay for one serial port: 1 Scan this bar code: Enter Accumulate Mode / Set Timeout Delay

*+/$+YE*

*+/$+YE*

2 Scan the serial port from these bar codes: COM1

COM2

*1.*

*2.*

*1.*

258

*2.*

Trakker Antares 2400 Family System Manual

Page 279

Chapter 6 - Configuration Command Reference COM3

COM4

*3.*

*3.*

*4.*

*4.*

3 Scan the timeout delay from these bar codes: Timeout Delay 5 ms

*0*

Timeout Delay 100 ms

*1*

*0*

*1*

Timeout Delay 500 ms

Timeout Delay 2 sec

*2*

*3*

*2*

*3*

Timeout Delay 10 sec

Timeout Delay 20 sec

*4*

*5*

*4*

*5*

Timeout Delay 40 sec

Timeout Delay 60 sec

*6*

*6*

*7*

*7*

4 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

5 Repeat Steps 1 through 4 to set the timeout delay for another serial port.

Transmit Mode Terminals: 2415, 2425, 2435, 2455, 2475, and 2485/6 with OpenAir radios. Description: Defines the transmit mode that the RF terminal radio uses. There are three modes: BFSK, QFSK, and Auto. Transmit Modes Mode BFSK

Description Binary Frequency Shift Key. A broadcasting method the radio uses that lengthens the range but halves the throughput. This method is switched when the RF protocol on the terminal determines that communications are degrading.

QFSK

Quad Frequency Shift Key. A broadcasting method the radio uses that shortens the range, but doubles the throughput. QFSK is the method used under standard radio conditions.

Auto

The terminal radio automatically switches modes between BFSK and QFSK as needed.

Trakker Antares 2400 Family System Manual

259

Page 280

Chapter 6 - Configuration Command Reference

Note: Even if you set this configuration command, the radio on the RF terminal will reset the parameter as needed to maximize the broadcasting range and throughput. Syntax: RTdata Acceptable values for data are: 0 1 3 Default:

BFSK (Binary Frequency Shift Key) QFSK (Quad Frequency Shift Key) Auto

BFSK

Menu System: Main Menu > Configuration Menu > Communications Menu > Radio Bar Codes: Scan one of these bar codes: Set Transmit Mode to BFSK

*$+RT0* *$+RT0*

Set Transmit Mode to QFSK

*$+RT1*

*$+RT1*

Set Transmit Mode to Auto

*$+RT3* *$+RT3*

Transmit Rate Terminals: 2415, 2425, 2435, 2455, 2475, and 2485/6 with 802.11b radios. Description: Sets the bit rate for data transmissions. A slower transmit rate provides a better range. You should configure the terminals that are on the perimeter of the access point coverage area to the slower transmit rate. A faster transmit rate provides better throughput. You should configure most of the terminals to the faster transmit range. Syntax: LEdata Acceptable values for data are: 0 Maximum available 1 1 Mbps (Low) 2 2 Mbps (Standard) 5 5.5 Mbps (Medium) 11 11 Mbps (High) Default:

Maximum available

Menu System: Main Menu > Configuration Menu > Communications Menu > Radio

260

Trakker Antares 2400 Family System Manual

Page 281

Chapter 6 - Configuration Command Reference

Bar Codes: Scan one of these bar codes: Set Transmit Rate to Maximum Available

*$+LE0*

Set Transmit Rate to 1 Mbps

*$+LE1*

*$+LE0*

*$+LE1*

Set Transmit Rate to 2 Mbps

Set Transmit Rate to 5.5 Mbps

*$+LE2* *$+LE2*

*$+LE5*

*$+LE5*

Set Transmit Rate to 11 Mbps

*$+LE11* *$+LE11*

Transmit Rate Fallback Terminals: 2415, 2425, 2435, 2455, 2475, and 2485/6 with 802.11b radios. Description: Determines if the RF terminal will try slower rates than the specified transmit rate. A packet may be undeliverable to a device at a given rate due to interference or range limitations. If you enable this command, the terminal will attempt to deliver the packet at a slower rate, which may have greater range or increased interference tolerance. Syntax: LFdata Acceptable values for data are: 0 1 Default:

Disabled Enabled

Enabled

Menu System: Main Menu > Configuration Menu > Communications Menu > Radio Bar Codes: Scan one of these bar codes: Disable Transmit Rate Fallback

*$+LF0* *$+LF0*

Enable Transmit Rate Fallback

*$+LF1*

*$+LF1*

UPC/EAN Terminals: All Trakker Antares terminals. Description: Enables or disables the decoding of Universal Product Code (UPC)/European Article Numbering (EAN) symbology. UPC/EAN are fixed-length, numeric, continuous symbologies that use four element widths. A terminal that is configured to decode EAN bar codes can decode UPC, but the reverse is not true. UPC code is a subset of EAN code. Trakker Antares 2400 Family System Manual

261

Page 282

Chapter 6 - Configuration Command Reference

To define the UPC/EAN symbology, you set up to seven digits. The supplemental portion of a UPC or EAN label is a weak symbology and can be missed by the scanner for several reasons. In situations where supplementals are known to be present, reading just the main symbol can be prevented until a valid supplemental is found. When using a laser scanner, performance degradation is not noticeable. The fifth, sixth, and seventh digits are optional. To set the sixth digit, you must set the fifth digit. To set the seventh digit, you must set all seven digits. Syntax: CEdata where data must be 4 to 7 digits selected from this list: Digit 1:

Digit 2:

Digit 3: Digit 4:

Digit 5: Digit 6: Digit 7:

0

UPC-A/EAN-13 disabled

1

UPC-A/EAN-13 enabled

2

UPC-A only enabled

0

UPC-E disabled

1

UPC-E enabled

2

Expanded zeroes

0

EAN-8 disabled

1

EAN-8 enabled

0

Supplementals not allowed

1

Supplementals allowed

2

Supplementals required

3

Two-digit supplementals required

4

Five-digit supplementals required

0

Discard check digit

1

Transmit check digit

0

Discard number system digit

1

Transmit number system digit

0

Discard the leading zero for UPC-A

1

Retain the leading zero for UPC-A

Note: E1022 linear imagers and later versions of integrated PDF417 and 1551 scanners do not support transmitting a number system digit for EAN-8. For help upgrading your scanner, contact your local Intermec service representative.

262

Trakker Antares 2400 Family System Manual