Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 20 of 38

Trakker Antares 2400 Family System Manual: Chapter 6 - Configuration Command Reference, pages 173 to 182

Pages 173 to 182 of 362, from Trakker Antares 2400 Family System Manual

The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 2410, Intermec 2415, Intermec 2435 and Intermec 2475

Page 173

Chapter 6 - Configuration Command Reference

Syntax: CH8data where data can be up to 10 digits corresponding to: Digit 1:

Digit 2: Digits 3-4:

0

Symbology identifier (ID) disabled.

1

Symbology identifier enabled. Output of ]C0 indicates a single ISBT 128 bar code was read. Output of ]C4 indicates that a pair of ISBT Code 128 bar codes was read.

0

Concatenation disabled.

1

Restricted concatenation enabled.

See List *

Left Data ID (identifier) to be matched for restricted concatenation. * List of valid combinations are:

Digits 5-6

See List *

Trakker Antares 2400 Family System Manual

=%

Blood Groups and Rh

=>

Expiration Date

&>

Expiration Date and Time

=*

Collection Date

&*

Collection Date and Time

=<

ISBT Product Code

=)

Manufacturer ID

&)

Manufacturer Lot Number

=&

Concatenation Bar Code

&<

National Product Code

&(

National Special Test

&!

Unit Exclusion Status

&;

National Special Donor

=n

Donation ID Number where n is a value from 0 to 9 or uppercase A through Z

&n from

National Use Bar Code where n is a value lowercase a through z

Right Data ID to be matched for restricted concatenation. See the list of valid combinations for digits 3 and 4.

153

Page 174

Chapter 6 - Configuration Command Reference

Digits 7-9

000-999

Bar code concatenation control parameters. If digit 10 is “d,” digits 7 and 8 refer to the nominal distance in millimeters between the stop characters of two bar code labels that can be concatenated, and digit 9 is the bar code label positioning tolerance. If the distance between the two bar code labels is outside the limit set (assuming standard ISBT bar code print size), the bar code labels will not be concatenated. If digit 10 is “t,” digits 7, 8, and 9 are the decode time limit in milliseconds. If both bar code labels are not decoded in the same beam sweep within this time, the bar code labels are not concatenated. This time parameter is only accurate to a 25millisecond resolution.

Digit 10 d or t

Identifies the concatenation control as either the distance “d” between bar code labels or the time “t” in which concatenated bar code labels must be decoded. See the description for Digits 7-9.

Note: The Left Data ID and Right Data ID are used only with the restricted concatenation option. For example, the terminal will concatenate only those bar code labels with data identifiers that match the configured data identifiers. The spacing between bar codes that can be concatenated must be between 2 and 5 character widths. Default:

Digit 1: Symbology ID disabled Digit 2: Concatenation disabled

Bar Codes: To enable ISBT Code 128 with the default settings, scan this bar code. Enable ISBT Code 128

*$+CH8* *$+CH8*

Or: To configure ISBT Code 128: Note: To set this command using the bar code labels from the “Full ASCII Bar Code Chart” on page 284, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” on page 146. 1 Scan this bar code: Enter Accumulate Mode / Enable ISBT Code 128

*+/$+CH8*

*+/$+CH8*

154

Trakker Antares 2400 Family System Manual

Page 175

Chapter 6 - Configuration Command Reference

2 Scan one of these bar codes to disable or enable symbology ID: Disable Symbology ID

*0*

*0*

Enable Symbology ID

*1*

*1*

Note: Steps 3 through 9 are optional. 3 Scan one of these bar codes to disable or enable concatenation: Disable Concatenation

*0*

*0*

Enable Concatenation

*1*

*1*

If you disabled concatenation, go to Step 10. Otherwise, continue with Step 4. 4 Scan one of these bar codes to set the Left Data ID: Blood Groups and Rh

Expiration Date

*%H/E*

*%H%I*

Expiration Date and Time

Collection Date

*/F%I*

*%H/J*

Collection Date and Time

ISBT Product Code

*/F/J*

*%H%G*

Manufacturer ID

Manufacturer Lot Number

*=%*

*&>*

*&**

*%H/I*

*=>*

*=**

*=<*

*/F/I*

*=)*

*&)*

Concatenation Bar Code

National Product Code

*%H/F*

*/F%G*

*=&*

*&<*

National Special Test

Unit Exclusion Status

*/F/H*

*/F/A*

*&(*

*&!*

National Special Donor

Donation ID Number (See Note)

*/F%F*

*%H*

*&;*

Trakker Antares 2400 Family System Manual

*=*

155

Page 176

Chapter 6 - Configuration Command Reference National Use Bar Code (See Note)

*/F*

*&*

If you scan the Donation ID Number or National Use Bar Code, continue with Step 5. Otherwise, go to Step 6. 5 For the Donation ID Number or the National Use Bar Code, scan an alphanumeric bar code from the “Full ASCII Bar Code Chart” on page 284. • For the Donation ID Number, scan a value from 0 through 9 or uppercase A through Z. • For the National Use Bar Code, scan a value from lowercase a through z. 6 Scan one of these bar codes to set the Right Data ID: Blood Groups and Rh

Expiration Date

*%H/E*

*%H%I*

Expiration Date and Time

Collection Date

*/F%I*

*%H/J*

Collection Date and Time

ISBT Product Code

*/F/J*

*%H%G*

Manufacturer ID

Manufacturer Lot Number

*=%*

*&>*

*&**

*%H/I*

*=>*

*=**

*=<*

*/F/I*

*=)*

*&)*

Concatenation Bar Code

National Product Code

*%H/F*

*/F%G*

*=&*

*&<*

National Special Test

Unit Exclusion Status

*/F/H*

*/F/A*

*&(*

*&!*

National Special Donor

Donation ID Number (See Note)

*/F%F*

*%H*

*&;*

*=*

National Use Bar Code (See Note)

*/F*

*&*

156

Trakker Antares 2400 Family System Manual

Page 177

Chapter 6 - Configuration Command Reference

7 For the Donation ID Number or the National Use Bar Code, scan an alphanumeric bar code from the “Full ASCII Bar Code Chart” on page 284. • For the Donation ID Number, scan a value from 0 through 9 or uppercase A through Z. • For the National Use Bar Code, scan a value from lowercase a through z. 8 If you want to keep the default concatenation control parameters, go to Step 10. • The default concatenation distance is 16 mm ± 0 mm. • The default concatenation decode time limit is 160 ms. If you want to set the concatenation control parameters, follow these instructions: • To set the concatenation decode time limit, scan these bar codes to set the time from 001 to 999 ms. • To set the concatenation distance, scan these bar codes to set the distance from 00 to 99 mm and the tolerance from ± 1 to 9 mm.

*0*

*1*

*0*

*1*

*2*

*3*

*2*

*4*

*4*

*6*

*6*

*8*

*8*

*3*

*5*

*5*

*7*

*7*

*9*

*9*

9 Scan one of these bar codes to set the concatenation distance or time limit: Distance

*+D*

*d*

Time

*+T*

*t*

10 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

Trakker Antares 2400 Family System Manual

157

Page 178

Chapter 6 - Configuration Command Reference

Command Processing Terminals: All Trakker Antares terminals. Description: Command processing allows you to disable or enable reader commands. For example, you can disable the Change Configuration command. There are two ways to enable or disable reader commands: • Use the Command Processing configuration command described here. • Use the Reader Command Menu option in the Configuration Menu of the TRAKKER Antares 2400 Menu System. You may want to disable reader commands to prevent a user from accidentally entering a command or to use data that would otherwise be treated as a command. Any Code 39 or Code 93 bar code label that contains the 2-character to 4-character commands for Command Processing is treated as a reader command unless the command is disabled. For example, if you disable the Menu System reader command, you can no longer access the TRAKKER Antares 2400 Menu System using the keypad. If you want to disable or enable several commands, it is easier to use the menu system. For help, see Chapter 2, “Configuring and Managing the Terminals.” For a description of each reader command that you can enable or disable with Command Processing, see Chapter 5, “Reader Command Reference.” Note: Not all reader commands are available on all terminals. To determine which commands are available on your terminal, see Chapter 5, “Reader Command Reference.” Syntax: DCdata Acceptable values for data are: 0 1 2 3 command0 command1

Disable all reader commands Enable all reader commands Disable override Enable override Disable reader command Enable reader command

The Enable Override option is a temporary setting that allows you to enable all the reader commands for as long as you need them. For help using the Enable Override and Disable Override options, see “Using the Override Options” on page 161. Note: Do not send the Disable All Reader Commands command to the terminal using Wavelink Avalanche. Default: 158

All reader commands enabled Trakker Antares 2400 Family System Manual

Page 179

Chapter 6 - Configuration Command Reference

Menu System: Main Menu > Configuration Menu > Terminal Menu > Reader Commands Note: Before using the following scanning options, you must make sure that the Enable Override option is not on. For help, see “Using the Override Options” on page 161. Bar Codes: To disable or enable all the reader commands, scan one of these bar codes: Disable All Reader Commands

*$+DC0* *$+DC0*

Enable All Reader Commands

*$+DC1*

*$+DC1*

Or: To disable or enable specific reader commands, perform these steps: 1 Scan this bar code: Enter Accumulate Mode / Command Processing

*+/$+DC*

*+/$+DC*

2 Scan the bar code to disable or enable one reader command. Abort Program

*/$*

*/$*

Boot Terminal

Change Configuration

*-.1*

*$+*

Default/Save Configuration

Delete File

*-.1*

*.+*

*$+*

*..--*

*.+*

*..--*

Receive File

Rename File

*.%*

*...-*

Reset Firmware

Run Program

*.%*

*-.*

*...-*

*//*

*-.*

*//*

Scanner Trigger Off

Scanner Trigger On

*/%*

*/.*

Set Time and Date

Status Lights and Sense Inputs Control

*/%*

*/+*

*/+*

Trakker Antares 2400 Family System Manual

*/.*

*$%*

*$%*

159

Page 180

Chapter 6 - Configuration Command Reference TRAKKER Antares 2400 Menu System

*..-.*

*..-.*

Transmit File

*%%*

*%%*

Note: Accumulate mode commands are separated into two bar codes so that the command can be accumulated rather than executed as a command. You need to scan the following bar codes in order from left to right. Backspace

*-*

(continued)

*+*

*-*

*+*

Clear

(continued)

*-*

*-*

*-*

*-*

Enter Accumulate Mode

(continued)

*+*

*/*

*+*

*/*

Exit Accumulate Mode

(continued)

*-*

*-*

*/*

*/*

3 Scan one of these bar codes: Disable the Command

*0*

*0*

Enable the Command

*1*

*1*

4 Repeat Steps 2 and 3 to disable or enable another reader command. Note: You can accumulate up to 250 characters in the buffer. If the data accumulated exceeds 250 characters, you will hear an error beep and the terminal will reject the last bar code read. 5 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

Other:

To disable or enable the ability to scan multiple-read labels, scan one of these bar codes: Disable Multiple-Read Labels

*$+DC0* *$+DC0*

160

Enable Multiple-Read Labels

*$+DC1*

*$+DC1*

Trakker Antares 2400 Family System Manual

Page 181

Chapter 6 - Configuration Command Reference

To quickly disable or enable the Menu System (Test and Service Mode), scan one of these bar codes: Disable Menu System

*$+DC..-.0* *$+DC..-.0*

Enable Menu System

*$+DC..-.1* *$+DC..-.1*

Using the Override Options You can disable or enable reader commands using the Command Processing configuration command or the TRAKKER Antares 2400 Menu System. To temporarily enable all the reader commands, you can use the Enable Override option. You must use the Disable Override option to return the terminal to the previous configuration. Note: If you do not use the Disable Override option, you may not be able to disable or enable reader commands. The Enable Override option is the only bar code label you can scan to enable reader commands if you have disabled all reader commands (DC0). However, you can also enable reader commands in the TRAKKER Antares 2400 Menu System. Bar Codes: To use the override options, scan one of these bar code labels: Enable Override

*$+DC3*

*$+DC3*

Disable Override

*$+DC2*

*$+DC2*

Configuration Commands Via Serial Port Terminals: All Trakker Antares terminals. Description: Allows you to control the data the terminal receives through the serial port. You can configure this command for the Configurable communications protocol. For more information, see the networking chapter in your user’s manual. You can set this command to execute reader and configuration commands received through the serial port or treat all data as data without checking for special command syntax. There are three options.

Trakker Antares 2400 Family System Manual

161

Page 182

Chapter 6 - Configuration Command Reference

Options for Configuration Commands Via Serial Port Option Disabled

Description All data received through the serial port is treated as data. The terminal will not execute reader or configuration commands sent or encoded in the data.

Enabled with TMF

If the data is sent with the TMF (Terminal Message Format) header, the terminal will check for and execute reader or configuration commands received through the serial port. With TMF, you can execute reader and configuration commands or send and receive data about the current terminal configuration.

Enabled without TMF

The terminal will check for and execute all reader and configuration commands (i.e., Receive File reader command or Beep Volume change configuration command).

Note: Before you can enable Configuration Commands Via Serial Port with or without TMF, you must configure the EOM command. Syntax: YTn.data where n is: 1 2 3 4

COM1 serial port COM2 serial port (246X and 248X terminals only) COM3 serial port (242X terminals only) COM4 serial port (242X, 2455, and 248X terminals only)

Acceptable values for data are: 0 1 2 Default:

Disabled Enabled with TMF Enabled without TMF

Enabled without TMF

Menu System: Main Menu > Configuration Menu > Communications Menu > Serial Port Bar Codes: To set the default for each serial port, scan these bar codes: COM1 Commands Via Serial Port Enabled Without TMF

*$+YT1.2*

*$+YT2.2*

*$+YT1.2*

$+YT2.2*

COM3 Commands Via Serial Port Enabled Without TMF

COM4 Commands Via Serial Port Enabled Without TMF

*$+YT3.2* *$+YT3.2*

162

COM2 Commands Via Serial Port Enabled Without TMF

*$+YT4.2*

*$+YT4.2*

Trakker Antares 2400 Family System Manual