Page 163

Chapter 6 - Configuration Command Reference

Codabar Terminals: All Trakker Antares terminals. Description: Enables or disables decoding of Codabar symbology. Codabar is a self-checking, discrete symbology. The American Blood Commission (ABC) Codabar requires that you retain and transmit the start/stop code digits when processing a Codabar symbol. As a result, configuration CD10 is an illegal configuration. Syntax: CDdata Acceptable values for data must be two digits, corresponding to: Digit 1:

Digit 2:

0

Disabled

1

ABC

2

Standard

3

Concatenated

0

Discard Start/Stop

1

Transmit ABCD Start/Stop

2

Transmit DC1-DC4 Start/Stop

Note: Concatenated is not supported on terminals with an integrated E1022 linear imager or an integrated PDF417 scan engine. Default:

Disabled

Menu System: Main Menu > Configuration Menu > Symbologies Menu Bar Codes: Scan one of these bar codes: Disabled, Discard Start/Stop

*$+CD00*

ABC, Transmit ABCD Start/Stop

*$+CD11*

*$+CD00*

*$+CD11*

ABC, Transmit DC1-DC4 Start/Stop

Standard, Discard Start/Stop

*$+CD12*

*$+CD20*

*$+CD12*

Trakker Antares 2400 Family System Manual

*$+CD20*

143

Page 164

Chapter 6 - Configuration Command Reference

Standard, Transmit ABCD Start/Stop

Standard, Transmit DC1-DC4 Start/Stop

*$+CD21*

*$+CD22*

Concatenated, Discard Start/Stop

Concatenated, Transmit ABCDStart/Stop

*$+CD30*

*$+CD31*

*$+CD21*

*$+CD22*

*$+CD30*

*$+CD31*

Concatenated, Transmit DC1-DC4 Start/Stop

*$+CD32* *$+CD32*

Code 11 Terminals: All Trakker Antares terminals configured for non-decoded scanning. Description: Enables or disables decoding of Code 11 symbology. Code 11 is a very high density, discrete numeric bar code. It is most extensively used in labeling telecommunications components and equipment. Syntax: CGdata Acceptable values for data are: 0 1 2 Default:

Disabled Code 11 enabled with one check digit Code 11 enabled with two check digits

Disabled

Menu System: Main Menu > Configuration Menu > Symbologies Menu > Code 11 Bar Codes: Scan one of these bar codes: Code 11 Enabled With One Check Digit

Disable Code 11

*$+CG0*

*$+CG1*

*$+CG0*

*$+CG1*

Code 11 Enabled With Two Check Digits

*$+CG2* *$+CG2*

144

Trakker Antares 2400 Family System Manual

Page 165

Chapter 6 - Configuration Command Reference

Code 2 of 5 Terminals: All Trakker Antares terminals. Description: Enables or disables decoding of Code 2 of 5 symbology. Code 2 of 5 uses the bars to encode information and the spaces to separate the individual bars. This code is discrete and self-checking. You can only enable Code 2 of 5 if the Interleaved 2 of 5 (I 2 of 5) code is disabled. If you enable I 2 of 5, Code 2 of 5 is automatically disabled. Enabling Code 2 of 5 automatically disables Interleaved 2 of 5 (I 2 of 5). Syntax: CCdata where data consists of three digits as follows: Digit 1:

0 1

Digits 2 and 3: 00 01-32

Code 2 of 5, 3 Bar Start/Stop Code 2 of 5, 2 Bar Start/Stop Disable Code 2 of 5 Label Length

Note: Label lengths less than 3 are not supported on terminals with an integrated E1022 linear imager or an integrated PDF417 scan engine. Default:

Disabled

Menu System: Main Menu > Configuration Menu > Symbologies Menu > 2 of 5/I 2 of 5 Bar Codes: To disable Code 2 of 5, scan this bar code: Disable Code 2 of 5

*$+CC000* *$+CC000*

Or: To enable Code 2 of 5: 1 Scan one of these bar codes: Enter Accumulate Mode / Enter Accumulate Mode / Enable Enable Code 2 of 5, 3 Bar Start/Stop Code 2 of 5, 2 Bar Start/Stop

*+/$+CC0*

*+/$+CC0*

*+/$+CC1*

*+/$+CC1*

2 Scan a two-digit numeric value to set the label length (01-32) from these bar codes.

*0*

*0*

Trakker Antares 2400 Family System Manual

*1*

*1*

145

Page 166

Chapter 6 - Configuration Command Reference

*2*

*2*

*4*

*4*

*6*

*6*

*8*

*8*

*3*

*3*

*5*

*5*

*7*

*7*

*9*

*9*

3 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

Code 39 Terminals: All Trakker Antares terminals. Description: Enables or disables decoding of Code 39 symbology. Code 39 is discrete, variable length, and self-checking. The character set is uppercase A to Z, 0 to 9, dollar sign ($), period (.), slash (/), percent (%), space ( ), plus (+), and minus (-). There are three types of ASCII the terminal decodes: • Code 39 non-full ASCII • Code 39 full ASCII • Code 39 mixed-full ASCII

Code 39 Non-Full ASCII Non-full ASCII uses a one-character encoding scheme. For example, you encode the data “SAMPLE” as follows:

*SAMPLE*

*SAMPLE*

This label decodes as SAMPLE.

Code 39 Full ASCII Full ASCII uses a two-character encoding scheme to extend the character set to 128 characters. You use the dollar sign ($), slash (/), percent (%), or plus (+) followed by an uppercase letter to represent one of the characters in the extended set. You must encode lowercase letters as a plus sign (+) followed by their uppercase equivalents. For a list of ASCII characters and their Code 39 representations, see the “Full ASCII Table” on page 284.

146

Trakker Antares 2400 Family System Manual

Page 167

Chapter 6 - Configuration Command Reference

Use Code 39 full ASCII to enter ASCII control characters or lowercase characters as data. You should also enable Code 39 full ASCII to use ASCII command characters. For example, you encode the data “sample” in Code 39 full ASCII as follows:

*+S+A+M+P+L+E* *+S+A+M+P+L+E*

In Code 39 non-full ASCII, this label decodes as +S+A+M+P+L+E. In Code 39 full ASCII, this label decodes as sample.

Code 39 mixed-full ASCII Use mixed-full ASCII when printers encode the same label two different ways. For example, if you have a bar code with the data %a, some printers encode the data as follows:

*/E+A* */E+A*

In the Full ASCII Table on page 284, /E represents %. If you configure the terminal for Code 39 full ASCII, the terminal decodes the data as %a because there are three valid full ASCII character pairs to represent the data. Other printers encode the data %a as:

*%+A* *%+A*

The % is a valid Code 39 character in the non-full ASCII character set. However, the terminal will not decode this label if it is configured for full ASCII, because the data is not represented by valid full ASCII character pairs. To decode the label correctly, you need to configure the terminal for mixed-full ASCII. When you configure the terminal for Code 39 mixed-full ASCII, the terminal will decode both of the labels above as %a. Mixed-full ASCII interprets any valid full ASCII character pairs that appear in the label, but does not require that all data be encoded with a valid full ASCII character pair. If you are uncertain how your labels are encoded, configure the terminal for mixed-full ASCII, which decodes all valid Code 39 labels. If you configure the terminal for Code 39 full ASCII, you should check for Code 39 mixed-full ASCII. Mixed-full ASCII does not apply when you configure the terminal for non-full ASCII. Note: The interpretive text shown under bar code labels does not always accurately reflect the data that is encoded in the label. The interpretive text represents how the label should be decoded.

Trakker Antares 2400 Family System Manual

147

Page 168

Chapter 6 - Configuration Command Reference

Use this table to help configure your terminal. Code 39 ASCII Decodes Code 39 Option Non-full ASCII

Bar Code Label $%+A /D/E+A

Decodes $%+A /D/E+A

Full ASCII

$%+A /D/E+A

No decode $%a

Mixed-full ASCII

$%+A /D/E+A

$%a $%a

Syntax: CBdata Acceptable values for data must be three digits, corresponding to: Digit 1:

0 1 2 3 4

Disabled Enabled with no check digit Enabled with check digit HIBC (Health Industry Bar Code) With AIAG check digit

Digit 2:

0 1

Discard check digit Retain check digit

Digit 3:

0 1 2

Code 39 non-full ASCII Code 39 full ASCII Code 39 mixed-full ASCII

Note: Selecting HIBC Code 39 automatically sets the configuration to non-full ASCII with the check digit transmitted. HIBC and With AIAG check digit are not supported on terminals with an integrated E1022 linear imager or an integrated PDF417 scan engine. Default:

Enable Code 39 Full ASCII with no check digit (111)

Menu System: Main Menu > Configuration Menu > Symbologies Menu > Code 39 Bar Codes: To disable Code 39, scan this bar code: Disable Code 39

*$+CB0* *$+CB0*

Or: To enable Code 39: 1 Scan this bar code: Enter Accumulate Mode / Enable Code 39

*+/$+CB*

*+/$+CB*

148

Trakker Antares 2400 Family System Manual

Page 169

Chapter 6 - Configuration Command Reference

2 Scan one of these bar codes to set the first digit: Without a Check Digit

*1*

With a Check Digit

*2*

*1*

*2*

HIBC Code 39

With AIAG Check Digit

*3*

*3*

*4*

*4*

3 Scan one of these bar codes to set the second digit: Discard Check Digit

Transmit Check Digit

*0*

*1*

*0*

*1*

4 Scan one of these bar codes to set the third digit: Code 39 Non-Full ASCII

*0*

*0*

Code 39 Full ASCII

*1*

*1*

Code 39 Mixed-Full ASCII

*2*

*2*

5 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

Code 93 Terminals: All Trakker Antares terminals. Description: Enables or disables decoding of Code 93 symbology. Code 93 is a variable length, continuous symbology that uses four element widths. Syntax: CFdata Acceptable values for data are: 0 1 Default:

Disabled Enabled

Disabled

Menu System: Main Menu > Configuration Menu > Symbologies Menu > Code 93

Trakker Antares 2400 Family System Manual

149

Page 170

Chapter 6 - Configuration Command Reference

Bar Codes: Scan one of these bar codes: Disable Code 93

*$+CF0* *$+CF0*

Enable Code 93

*$+CF1*

*$+CF1*

Code 128 Terminals: All Trakker Antares terminals. Description: Enables or disables decoding of Code 128 symbology. Code 128 is a very high density alphanumeric symbology that supports the extended ASCII character set. It is a variable length, continuous code that uses multiple element widths. If you configure Standard Code 128, the terminal will not decode Function Code 1 characters in the first position of a bar code label. Any subsequent Function Code 1 characters are translated to the ASCII GS character as a separator for variable length fields. When you enable Standard Code 128, it is automatically configured for industry standard concatenation. Note: For help configuring UCC/EAN Code 128, see “UCC/EAN Code 128” on page 151. For help configuring ISBT Code 128, see “ISBT Code 128” on page 152. Syntax: CHdata Acceptable values for data are: 0 1 2 8

Disabled Standard Code 128 UCC/EAN Code 128 ISBT Code 128

Note: ISBT Code 128 is not supported on terminals with an integrated E1022 linear imager or an integrated PDF417 scan engine. Default:

Standard

Menu System: Main Menu > Configuration Menu > Symbologies Menu > Code 128 Bar Codes: Scan one of these bar codes: Disable Code 128

*$+CH0* *$+CH0*

150

Enable Standard Code 128

*$+CH1*

*$+CH1*

Trakker Antares 2400 Family System Manual

Page 171

Chapter 6 - Configuration Command Reference Enable UCC/EAN Code 128

*$+CH2* *$+CH2*

Enable ISBT Code 128

*$+CH8*

*$+CH8*

Or: To configure Standard Code 128: 1 Scan this bar code: Enter Accumulate Mode / Enable Standard Code 128

*+/$+CH1*

*+/$+CH1*

2 Scan one of these bar codes to disable or enable concatenation: Disable Concatenation

Enable Concatenation

*0*

*1*

*0*

*1*

3 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

UCC/EAN Code 128 Description: Enables and configures decoding of the UCC/EAN Code 128 symbology. When you enable the UCC/EAN Code 128 symbology, it is automatically configured for concatenation. If you configure UCC/EAN Code 128, the terminal will decode a bar code label as Standard Code 128 unless one of the first two characters are a start character and a Function Code 1. In this case, the bar code label is processed as described next: 1 The Function Code 1 character is not transmitted. 2 The three symbology ID characters, ]C1, are transmitted. 3 The remaining Code 128 characters are decoded as Standard Code 128. Syntax: CH2data Acceptable values for data must be two digits, corresponding to: Digit 1:

0 1

Symbology identifier (ID) disabled. Symbology identifier enabled. Output of ]C1.

Digit 2:

0 1

Concatenation disabled. Restricted concatenation enabled.

Trakker Antares 2400 Family System Manual

151

Page 172

Chapter 6 - Configuration Command Reference

Note: A GTIN compliant EAN 128 label: 1 is 16 digits long. 2 has “01” as the first two digits of the label. With GTIN Compliance enabled, a GTIN compliant EAN 128 label will have the first two digits stripped and output 14 digits. For more information, see “GTIN Compliance” on page 189. Default:

Digit 1: Digit 2:

Symbology ID disabled Concatenation enabled

Bar Codes: To configure UCC/EAN Code 128: 1 Scan this bar code: Enter Accumulate Mode / Enable UCC/EAN Code 128

*+/$+CH2*

*+/$+CH2*

2 Scan one of these bar codes to disable or enable symbology ID: Disable Symbology ID

*0*

*0*

Enable Symbology ID

*1*

*1*

3 Scan one of these bar codes to disable or enable concatenation: Disable Concatenation

*0*

*0*

Enable Concatenation

*1*

*1*

4 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

ISBT Code 128 Description: Enables and configures decoding of ISBT Code 128 symbology. ISBT Code 128 is the global bar code labeling standard for the blood banking industry. It is used to support the world-wide distribution, tracking and handling of blood bags and blood components. For more information on ISBT Code 128, refer to the ISBT 128 Bar Code Symbology and Application Specification for Labeling of Whole Blood and Blood Components prepared by the International Council for Commonality in Blood Banking Automation.

152