The text of a manual · part 18 of 38
Trakker Antares 2400 Family System Manual: Chapter 6 - Configuration Command Reference, pages 153 to 162
Pages 153 to 162 of 362, from Trakker Antares 2400 Family System Manual
The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2410, Intermec 2415, Intermec 2435 and Intermec 2475
Page 153
Chapter 6 - Configuration Command Reference
*4*
*4*
*6*
*6*
*8*
*8*
*5*
*5*
*7*
*7*
*9*
*9*
3 Scan this bar code: Exit Accumulate Mode
*-/*
*-/*
AP Density Terminals: 2415, 2425, 2435, 2455, 2475, and 2485/6 with 802.11b radios. Description: Controls the roaming sensitivity of the radios. You can use this parameter to virtually reduce the range of the radio. When you increase the AP density, you do not reduce the absolute range of the radio, but the roaming algorithms are modified to allow significant overlap of the radio coverage. Increasing the AP density lets you create a higher performance radio network, but you will need significantly more access points to cover a given area. Syntax: LGdata Acceptable values for data are: 1 2 3 Default:
Low density Medium density High density
Low density
Menu System: Main Menu > Configuration Menu > Communications Menu > Radio Bar Codes: Scan one of these bar codes: Low AP Density
*$+LG1* *$+LG1*
Medium AP Density
*$+LG2*
*$+LG2*
High AP Density
*$+LG3* *$+LG3*
Trakker Antares 2400 Family System Manual
133
Page 154
Chapter 6 - Configuration Command Reference
AP MAC Address Terminals: 2415, 2425, 2435, 2455, 2475, and 2485/6. Description: Returns the MAC address of the radio that is installed in the access point that the terminal is communicating with. You can only use this read-only command in an application to return the value (MAC address) to the application. Syntax: RA Default:
None
Menu System: N/A Bar Codes: N/A
Append Time Terminals: All Trakker Antares terminals. Description: Appends the time to bar code labels that are scanned into the terminal. You can also use the Time in Seconds command to append the time in hours and minutes only, or hours, minutes, and seconds. The time is appended to the data in the form HH:MM:SS. For help, see “Time in Seconds” on page 256. Syntax: DEdata Acceptable values for data are: 0 1 Default:
Disabled Enabled
Disabled
Menu System: Main Menu > Configuration Menu > Terminal Menu > Append Time Bar Codes: Scan one of these bar codes: Disable Append Time
*$+DE0* *$+DE0*
134
Enable Append Time
*$+DE1*
*$+DE1*
Trakker Antares 2400 Family System Manual
Page 155
Chapter 6 - Configuration Command Reference
Automatic Shutoff Terminals: All Trakker Antares terminals. Description: Defines the maximum length of time the terminal remains on when there is no activity. When you do not use the terminal for the length of time set with this command, the terminal automatically turns off as if you had pressed œ to turn it off. When you press œ to turn on the terminal, the terminal either resumes exactly where it was when you turned it off, or the terminal boots and restarts your application. Resume is controlled through the Resume Execution command. For help, see “Resume Execution” on page 226. Power Management Tip: You should use the Automatic Shutoff feature to preserve battery pack power on 241X, 242X, and 243X terminals. Syntax: EZdata Acceptable values for data are: 0 Disabled (always on) 02-75 Shutoff time in minutes Default:
0 (Disabled)
Menu System: Main Menu > Configuration Menu > Terminal Menu > Power Management Bar Codes: To disable automatic shutoff, scan this bar code: Disable Automatic Shutoff
*$+EZ0* *$+EZ0*
Or: To set a timeout: 1 Scan this bar code: Enter Accumulate Mode / Set Automatic Shutoff
*+/$+EZ*
*+/$+EZ*
2 Scan a numeric value for data from these bar codes:
*0*
*0*
*2*
*2*
Trakker Antares 2400 Family System Manual
*1*
*1*
*3*
*3*
135
Page 156
Chapter 6 - Configuration Command Reference
*4*
*4*
*6*
*6*
*8*
*8*
*5*
*5*
*7*
*7*
*9*
*9*
3 Scan this bar code: Exit Accumulate Mode
*-/*
*-/*
Baud Rate Terminals: All Trakker Antares terminals. Description: Sets the baud rate for the serial port on the terminal. The baud rate must match the baud rate of the device (i.e. the host computer) that the terminal is communicating with through the serial port. You can configure the baud rate for these communications protocols: Binary, Configurable, Master Polling, and Polling Mode D. For more information, see the networking chapter in your user’s manual. Syntax: YAn.data where n is: 1 2 3 4
COM1 serial port COM2 serial port (246X and 248X terminals only) COM3 serial port (242X terminals only) COM4 serial port (242X, 2455, and 248X terminals only)
Acceptable values for data are: 3 4 5 6 7 8
1200 baud 2400 baud 4800 baud 9600 baud 19200 baud 38400 baud
Note: For COM3 serial ports, the maximum baud rate is actually 33600 baud. Default:
19200
Menu System: Main Menu > Configuration Menu > Communications Menu > Serial Port
136
Trakker Antares 2400 Family System Manual
Page 157
Chapter 6 - Configuration Command Reference
Bar Codes: To set the default baud rate for each serial port, scan these bar codes: Default Baud Rate for COM1
*$+YA1.7*
Default Baud Rate for COM2
*$+YA2.7*
*$+YA1.7*
*$+YA2.7*
Default Baud Rate for COM3
Default Baud Rate for COM4
*$+YA3.7* *$+YA3.7*
*$+YA4.7*
*$+YA4.7*
Or: To set the baud rate for one serial port: 1 Scan this bar code: Enter Accumulate Mode / Set Baud Rate
*+/$+YA*
*+/$+YA*
2 Scan the serial port from these bar codes: COM1
*1.*
COM2
*2.*
*1.*
*2.*
COM3
COM4
*3.*
*3.*
*4.*
*4.*
3 Scan the baud rate from these bar codes: 1200 Baud
*3*
2400 Baud
*4*
*3*
*4*
4800 Baud
9600 Baud
*5*
*6*
*5*
*6*
19200 Baud
38400 Baud
*7*
*7*
*8*
*8*
4 Scan this bar code: Exit Accumulate Mode
*-/*
*-/*
5 Repeat Steps 1 through 4 to set the baud rate for another serial port.
Trakker Antares 2400 Family System Manual
137
Page 158
Chapter 6 - Configuration Command Reference
Beep Duration Terminals: All Trakker Antares terminals. Description: Sets the length of the terminal’s audio signals. You can define a different duration for the high and the low beep tone. Use Beep Duration with Beep Frequency and Beep Volume to define audio signals (beeps and keyclicks) according to operator preference and work environment. Syntax: BDdatabeep Acceptable values for data are any number from 2 to 7999 ms. Acceptable values for beep are: H L Default:
High Low
243X: 150 ms high and 50 ms low beep tones 241X, 242X, 2455, 246X, 2475, 248X: 50 ms, high and 50 ms low beep tones
Menu System: Not supported Bar Codes: To set the default beep duration, scan one of these bar codes: Default Beep Duration, 243X
*$+BD150HBD50L* *$+BD150HBD50L*
Default Beep Duration, 241X, 242X, 2455, 246X, 2475, 248X
*$+BD50HBD50L* *$+BD50HBD50L*
Or: To set a beep duration: 1 Scan this bar code: Enter Accumulate Mode / Set Beep Duration
*+/$+BD*
*+/$+BD*
2 Scan a numeric value for data from these bar codes:
*0*
*1*
*2*
*3*
*2*
*4*
*4*
138
*1*
*0*
*3*
*5*
*5*
Trakker Antares 2400 Family System Manual
Page 159
Chapter 6 - Configuration Command Reference
*6*
*6*
*8*
*8*
*7*
*7*
*9*
*9*
3 Scan the beep tone for which you are setting the beep duration: High
Low
*H*
*L*
*H*
*L*
4 Scan this bar code: Exit Accumulate Mode
*-/*
*-/*
Beep Frequency Terminals: 241X, 242X, 243X, 2455, 2475, and 248X. Description: Sets the frequency, or pitch, of the terminal’s audio signals. Use Beep Frequency with Beep Duration and Beep Volume to define audio signals (beeps and keyclicks) according to operator preference and work environment. Note: The beep frequency response varies between terminals. You may need to test several beep frequencies to find the optimal frequency for the operator and work environment. Syntax: BFdatabeep Acceptable values for data are any number from 20 to 8000 Hz. Acceptable values for beep are: H L Default:
High Low
241X: 2400 Hz high, 1400 Hz low 243X: 1900 Hz high, 1050 Hz low 242X, 2455, 246X, 2475, 248X: 2400 Hz high, 1200 Hz low
Menu System: Not supported Bar Codes: To set the default beep frequency, scan one of these bar codes: Default Beep Frequency, 241X
*$+BF2400HBF1400L* *$+BF2400HBF1400L*
Trakker Antares 2400 Family System Manual
139
Page 160
Chapter 6 - Configuration Command Reference Default Beep Frequency, 243X
*$+BF1900HBF1050L* *$+BF1900HBF1050L*
Default Beep Frequency, 242X, 2455, 246X, 2475, 248X
*$+BF2400HBF1200L* *$+BF2400HBF1200L*
Or: To set a beep frequency: 1 Scan this bar code: Enter Accumulate Mode / Set Beep Frequency
*+/$+BF*
*+/$+BF*
2 Scan a numeric value for data from these bar codes:
*0*
*0*
*2*
*2*
*4*
*1*
*1*
*3*
*3*
*5*
*4*
*5*
*6*
*7*
*6*
*8*
*8*
*7*
*9*
*9*
3 Scan the beep tone for which you are setting the beep frequency: High
Low
*H*
*L*
*H*
*L*
4 Scan this bar code: Exit Accumulate Mode
*-/*
*-/*
Beep Volume Terminals: All Trakker Antares terminals. Description: Adjusts the volume of the terminal’s audio signals. Use Beep Volume with Beep Duration and Beep Frequency to define audio signals (beeps and keyclicks) according to operator preference and work environment. 140
Trakker Antares 2400 Family System Manual
Page 161
Chapter 6 - Configuration Command Reference
If you set the Beep Volume command to off, you will not hear any audio signals including the keyclick. Syntax: BVdata Acceptable values for data are: 0 1 2 3 4 8 9 Default:
Off Quiet Normal Loud Very loud Lower volume Raise volume
Very loud
Menu System: Main Menu > Configuration Menu > Terminal Menu > Beeper Bar Codes: Scan one of these bar codes: Beep Volume Off
*$+BV0*
Beep Volume Quiet
*$+BV1*
*$+BV0*
*$+BV1*
Beep Volume Normal
Beep Volume Loud
*$+BV2*
*$+BV2*
*$+BV3*
*$+BV3*
Beep Volume Very Loud
*$+BV4* *$+BV4*
Or: Scan one of these bar codes repeatedly to change the beep volume: Lower Beep Volume
*$+BV8*
*$+BV8*
Raise Beep Volume
*$+BV9*
*$+BV9*
Character Set Terminals: 246X. Description: Determines the language used to display characters. Syntax: DXdata Acceptable values for data are: 0 1 2 3
U.S. ASCII French German United Kingdom
Trakker Antares 2400 Family System Manual
141
Page 162
Chapter 6 - Configuration Command Reference
4 5 6 7 Default:
Danish / Norwegian Swedish Italian Spanish
U.S. ASCII
Menu System: N/A Bar Codes: Scan one of these bar code labels: U.S. ASCII Character Set
French Character Set
*$+DX0*
*$+DX1*
*$+DX0*
*$+DX1*
German Character Set
United Kingdom Character Set
*$+DX2*
*$+DX3*
*$+DX2*
*$+DX3*
Danish Character Set
Swedish Character Set
*$+DX4*
*$+DX5*
*$+DX4*
*$+DX5*
Italian Character Set
Spanish Character Set
*$+DX6*
*$+DX7*
*$+DX6*
*$+DX7*
The next table lists the ASCII characters that change for the seven European languages. Only these 11 characters change in any character set. All other characters in the ASCII chart remain as defined in the “Full ASCII Table” on page 284. ASCII Character Changes for Character Sets Hexadecimal Value Country
23
40
5B
5C
5D
5E
60
7B
7C
7D
7E
United States
#
@
[
\
]
^
'
{
|
}
~
England
£
@
[
\
]
^
'
{
¦
}
~
Germany
#
§
Ä
Ö
Ü
^
'
ä
ö
ü
ß
Denmark
#
@
Æ
Ø
Å
^
'
æ
ø
å
~
France
#
à
°
ç
§
^
'
é
ù
è
¨
Sweden
#
É
Ä
Ö
Å
Ü
é
ä
ö
å
ü
Italy
#
@ @
° ¡
ç Ñ
é ¿
^ ^
ù '
à ¨
ò ñ
è }
ì ~
Spain
142
Trakker Antares 2400 Family System Manual