The text of a manual · part 17 of 38
Trakker Antares 2400 Family System Manual: Chapter 6 - Configuration Command Reference, pages 143 to 152
Pages 143 to 152 of 362, from Trakker Antares 2400 Family System Manual
The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2410, Intermec 2415, Intermec 2435 and Intermec 2475
Page 143
6
Configuration Command Reference
This chapter describes all the configuration commands supported on the terminal and covers these topics: • Using configuration commands • Configuration commands listed by category • Entering variable data in a configuration command • Entering ASCII characters • Defining configuration commands
Trakker Antares 2400 Family System Manual
123
Page 144
Chapter 6 - Configuration Command Reference
Using Configuration Commands A configuration command changes the way the terminal operates. For example, you can change the Beep Volume and make the terminal beep very loud in a noisy environment. You can execute configuration commands by: • scanning a command from a Code 39 or Code 93 bar code label. Code 39 bar code labels are provided in this chapter. For help, see Chapter 2, “Configuring and Managing the Terminals.” Note: If you are working in the TRAKKER Antares 2400 Menu System, you cannot scan configuration commands. Exit the menu system to scan configuration commands. • choosing a command from the TRAKKER Antares 2400 Menu System. For help, see Chapter 2, “Configuring and Managing the Terminals.” • sending a command from a device on the serial, RF, or Ethernet network. For help, see Chapter 2, “Configuring and Managing the Terminals.” This chapter contains the following information about each configuration command: • List of terminals that support the command • Command description and purpose • Command syntax and options • Default setting • Location within the TRAKKER Antares 2400 Menu System • Bar code labels you can scan to set or change each command The configuration commands are listed alphabetically by command name. For a list of commands sorted by category, use the next table, “Configuration Commands Listed by Category.” If you want to look up a command by its syntax, see “Configuration Commands by Syntax” starting on page 276. Note: The Code 39 bar code labels in this chapter show an asterisk (*) at the beginning and end of the human-readable interpretation to represent the start and stop codes. If you are creating your own Code 39 bar code labels, your bar code printing utility may automatically supply the asterisks as the start/stop code. Note: If you are using the advanced long range scanner or scan module, you may not be able to scan the bar code labels in this manual. However, you can still send commands through the serial port or network. For help, see Chapter 2, “Configuring and Managing the Terminals.”
124
Trakker Antares 2400 Family System Manual
Page 145
Chapter 6 - Configuration Command Reference
Configuration Commands Listed by Category This chapter lists the configuration commands in alphabetical order. Use these lists to find the configuration commands you may need to set for bar code symbologies, operations, serial network communications, or RF and Ethernet network communications. Not all configuration commands apply to all terminals. Use the following tables to determine which commands are supported on your Trakker Antares® terminal. Bar Code Symbology Configuration Commands Bar Code Symbologies Codabar, 143
241X X
242X X
243X X
2455 X
246X X
2475 X
248X X
Code 11, 144
X
X
X
X
X
X
X
Code 2 of 5, 145
X
X
X
X
X
X
X
Code 39, 146
X
X
X
X
X
X
X
Code 93, 149
X
X
X
X
X
X
X
Code 128, 150
X
X
X
X
X
X
X
GTIN Compliance, 189
X
X
X
X
X
X
Interleaved 2 of 5, 195
X
X
X
X
X
X
X
MSI, 208
X
X
X
X
X
X
X
PDF417, 216
X
X
X
Plessey, 217
X
X
X
X
X
X
X
UPC/EAN, 261
X
X
X
X
X
X
X
241X X
242X X
243X X
2455 X
246X X
2475 X
248X X
Automatic Shutoff, 135
X
X
X
X
X
X
X
Beep Duration, 138
X
X
X
X
X
X
X
Beep Frequency, 139
X
X
X
X
X
X
Beep Volume, 140
X
X
X
X
X
X
Operations Configuration Commands Operations Append Time, 134
Character Set, 141 Command Processing, 158
X X
X
X
X
X
X
X
X
X
X
X
X
Decode Security, 168
X
X
X
Display Backlight Timeout, 175
X
X
X
Display Contrast, 176
X
X
X
X
X
X
Display Font Type, 178
X
X
X
X
X
X
Display Row Spacing, 179
X
X
X
X
X
X
Display Spacing, 180
X
X
X
X
X
X
Display Video Mode, 182
X
X
X
X
X
X
Trakker Antares 2400 Family System Manual
125
Page 146
Chapter 6 - Configuration Command Reference
Operations Configuration Commands (continued) Operations Flash Memory Configuration, 186
241X X
242X X
243X X
2455 X
246X X
2475 X
248X X
Keypad Caps Lock, 196
X
X
X
X
X
X
X
Keypad Clicker, 197
X
X
X
X
X
X
X
Keypad Control, 197
X
X
X
X
X
X
X
Keypad Type, 198
X
X
X
X
X
X
Postamble, 219
X
X
X
X
X
X
X
Preamble, 221
X
X
X
X
X
X
X
RAM Drive Size, 223
X
X
X
X
X
X
X
Resume Execution, 226
X
X
X
X
X
X
X
Scan Ahead, 228
X
X
X
X
X
X
X
Scanner Mode, 228
X
X
X
X
X
X
X
Scanner Redundancy, 230
X
X
X
X
X
X
X
Scanner Selection, 231
X
X
X
X
X
X
X
Scanner Timeout, 233
X
X
X
X
X
X
X
Scanner Trigger, 235
X
X
X
X
X
X
X
Suspend/Resume Control, 245
X
X
X
X
X
X
X
Symbology Identifiers, 245
X
X
X
X
X
X
X
Time and Date, 255
X
X
X
X
X
X
X
Time in Seconds, 256
X
X
X
X
X
X
X
Time Zone, 256
X
X
X
X
X
X
2475 X
248X X
Serial Network Communications Configuration Commands Serial Network Communications Baud Rate, 136
241X X
242X X
243X X
2455 X
246X X
Configuration Commands Via Serial Port, 161
X
X
X
X
X
X
X
Data Bits, 167
X
X
X
X
X
X
X
End of Message (EOM), 184
X
X
X
X
X
X
X
Flow Control, 187
X
X
X
X
X
X
X
Handshake, 190
X
X
X
X
X
X
X
LRC (Longitudinal Redundancy Check), 201
X
X
X
X
X
X
X
Modem Dial Sequence, 205
X
Modem Initialization Sequence, 206
X
Multi-Drop Address, 209
X
Parity, 214
X
X
X
X
Poll (Polling), 218
X
X
X
X
RS-232 or RS-422/485 COM2 Interface, 226
126
X
X
X
X
X
Scanner Port (COM4), 229 Serial Port Protocol, 237
X X X X
X X
X
X
X
X
X
X
Trakker Antares 2400 Family System Manual
Page 147
Chapter 6 - Configuration Command Reference
Serial Network Communications Configuration Commands (continued) Serial Network Communications Start of Message (SOM), 240
241X X
242X X
243X X
2455 X
246X X
2475 X
248X X
Stop Bits, 242
X
X
X
X
X
X
X
Timeout Delay, 257
X
X
X
X
X
X
X
2461
2475 X
248X X
X
X
RF and Ethernet Network Communications Configuration Commands RF and Ethernet Network Communications Acknowledgement Delay Lower Limit, 131
2415 X
2425 X
2435 X
2455 X
Acknowledgement Delay Upper Limit, 132
X
X
X
X
AP MAC Address, 134
X
X
X
X
X
X
Controller Connect Check Receive Timer, 163
X
X
X
X
X
X
Controller Connect Check Send Timer, 164
X
X
X
X
X
X
Controller IP Address, 166
X
X
X
X
X
X
X
Default Router, 169
X
X
X
X
X
X
X
DHCP (Controller), 173
X
X
X
X
X
X
X
DHCP (Terminal), 174
X
X
X
X
X
X
X
Host IP Address, 192
X
X
X
X
X
X
X
ICMP (Internet Control Message Protocol), 193
X
X
X
X
X
X
Maximum Retries, 202
X
X
X
X
Network Activate, 210
X
X
X
X
X
X
X
X
Network Loopback, 211
X
X
X
X
X
X
Network Port, 213
X
X
X
X
X
X
Radio MAC Address, 222
X
X
X
X
X
X
Subnet Mask, 243
X
X
X
X
TCP Maximum Retries, 250
X
X
X
X
X
X
X
X
X
X
TCP/IP Maximum Transmit Timeout, 251
X
X
X
X
X
X
X
Terminal IP Address, 252
X
X
X
X
X
X
X
Terminal Port, 254
X
X
X
X
X
X
2475
2485/6 X
X X
OpenAir RF Network Communications Configuration Commands OpenAir RF Network Domain, 183
2415 X
2425 X
2435 X
2455 X
246X
Inactivity Timeout, 193
X
X
X
X
X
Roaming Flag, 227
X
X
X
X
X
Security Identification (ID), 236
X
X
X
X
X
Transmit Mode, 259
X
X
X
X
X
Wakeup On Broadcast, 266
X
X
X
X
X
Trakker Antares 2400 Family System Manual
127
Page 148
Chapter 6 - Configuration Command Reference
802.11b RF Network Communications Configuration Commands 802.11b RF Network AP Density, 133
2415 X
2425 X
2435 X
2455 X
Maximum Sleep Duration, 203
X
X
X
Medium Reservation, 204
X
X
X
246X
2475 X
2485/6 X
X
X
X
X
X
X
Microwave Robustness, 205
X
X
X
X
X
X
Network Name, 211
X
X
X
X
X
X
Power Management, 220
X
X
X
X
X
X
Receive All Multicast, 224
X
X
X
X
X
X
Reservation Threshold, 225
X
X
X
X
X
X
Station Name, 242
X
X
X
X
X
X
Transmit Rate, 260
X
X
X
X
X
X
Transmit Rate Fallback, 261
X
X
X
X
X
X
WEP Encryption, 266
X
X
X
X
X
X
WEP Key, 267
X
X
X
X
X
X
WEP Transmit Key, 269
X
X
X
X
X
X
802.11b RF with 802.1x Security Network Communications Configuration Commands 802.11b RF with 802.1x Security Network Password, 215
2415 X
2425 X
2435 X
2455 X
Server Certificate Common Name (Server Cert CN), 239
X
X
X
User Name, 265
X
X
2415 X X
246X
2475 X
2485/6 X
X
X
X
X
X
X
X
2425 X
2435 X
2455 X
2475 X
2485/6 X
X
X
X
X
X
Device Management Configuration Commands Device Management Device Management, 170 Device Manager IP Address, 171
246X
Entering Variable Data in a Configuration Command You can enter variable data for many of the configuration commands. For example, you can set a preamble that is up to 25 ASCII characters long. You need to follow these general instructions to enter variable data. To enter variable data in a configuration command 1 Scan a bar code label with this syntax: +/$+command
128
Trakker Antares 2400 Family System Manual
Page 149
Chapter 6 - Configuration Command Reference where: +/ is the syntax for the Enter Accumulate Mode command.
$+ is the syntax for the Change Configuration command.
command is the syntax for the command you want to change.
For example, the command syntax for a preamble is ADdata. To change or set a preamble, scan this bar code: Enter Accumulate Mode / Change Configuration / Set Preamble
*+/$+AD*
*+/$+AD*
The Accumulate Mode screen appears. 2 Scan a bar code label from the “Full ASCII Bar Code Chart” on page 284. To set the preamble to the character T, scan this label: T
*T*
*T*
Note: To use the bar code labels from the “Full ASCII Bar Code Chart” on page 284, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” on page 146. 3 Scan the Exit Accumulate Mode bar code label to update the terminal’s configuration: Exit Accumulate Mode
*-/*
*-/*
Entering ASCII Characters You can use the TRAKKER Antares 2400 Menu System to enter characters for configuration commands, such as Preamble, Postamble, and WEP Key. You can enter these types of characters: • Nonprintable ASCII character, such as a control character or extended ASCII character • Escape character sequence • Quotation marks • Hexadecimal pair
Trakker Antares 2400 Family System Manual
129
Page 150
Chapter 6 - Configuration Command Reference
To type a nonprintable ASCII character • Use this syntax: \xhh where hh is the two-digit hexadecimal number for the control character or the extended ASCII character. For example, to enter ETX as a preamble, type: \x03
Or, to enter Ü (the 5250 TE Field Exit code), type: \x9A
To type an escape character (backslash) • Type two backslashes. The application ignores the first backslash (\) character and saves the next characters. For example: Enter These Characters \\
Characters Saved \
\\k
\k
\ no data
To type quotation marks • Enclose the data within quotation marks and precede each quotation mark with another quotation mark so that the quotation marks are not treated as the end of the data. For example, to set a postamble that includes quotation marks, enter the postamble by scanning this full ASCII bar code label: Set Postamble to “B”
*/D/KAE/B/B/BB/B/B/B* *$+AE"""B"""*
To enter hex pairs • You need to enter: 0xnn before you enter multiple values for data where nn is the hexadecimal values of the nonprintable characters. For example, to use a carriage return (0x0C) as a value in a WEP key string, send this command: $+LM0X41420D4142
The following value is returned: AB<cr>AB
130
Trakker Antares 2400 Family System Manual
Page 151
Chapter 6 - Configuration Command Reference
Acknowledgement Delay Lower Limit Terminals: 2415, 2425, 2435, 2455, 2475, and 2485/6. Description: When the terminal sends a message to the Intermec Gateway or DCS 30X, the terminal waits to receive a response acknowledging the message. If no response is received within the acknowledgement delay lower limit time, the terminal sends the message again at the time interval set for the lower limit. The terminal will continue to send the data at increasingly longer intervals until it reaches the acknowledgement delay upper limit time. The terminal continues sending the message at the time interval set for the upper limit until a response is received or a timeout error occurs. Syntax: NVdata Acceptable values for data are any number from 200 to 2000 ms. Default:
300 ms
Menu System: Main Menu > Configuration Menu > Communications Menu > Advanced Network Bar Codes: To set the default acknowledgement delay lower limit, scan this bar code: Default Acknowledgement Delay Lower Limit
*$+NV300* *$+NV300*
Or: To set the acknowledgement delay lower limit: 1 Scan this bar code: Enter Accumulate Mode / Set Acknowledgement Delay Lower Limit
*+/$+NV*
*+/$+NV*
2 Scan a numeric value for data from these bar codes:
*0*
*1*
*0*
*1*
*2*
*3*
*2*
*4*
*4*
*6*
*6*
*8*
*8*
Trakker Antares 2400 Family System Manual
*3*
*5*
*5*
*7*
*7*
*9*
*9*
131
Page 152
Chapter 6 - Configuration Command Reference
3 Scan this bar code: Exit Accumulate Mode
*-/*
*-/*
Acknowledgement Delay Upper Limit Terminals: 2415, 2425, 2435, 2455, 2475, and 2485/6. Description: When the terminal sends a message to the Intermec Gateway or DCS 30X, the terminal waits to receive a response acknowledging the message. If no response is received within the Acknowledgement Delay Lower Limit time, the terminal sends the message again at the time interval set for the lower limit. The terminal will continue to send the data at increasingly longer intervals until it reaches the Acknowledgement Delay Upper Limit time. The terminal continues sending the message at the time interval set for the upper limit until a response is received or a timeout error occurs. Syntax: NUdata Acceptable values for data are any number from 2000 to 60000 ms. Default:
5000 ms
Menu System: Main Menu > Configuration Menu > Communications Menu > Advanced Network Bar Codes: To set the default acknowledgement delay upper limit, scan this bar code: Default Acknowledgement Delay Upper Limit
*$+NU5000* *$+NU5000*
Or: To set the acknowledgement delay upper limit: 1 Scan this bar code: Enter Accumulate Mode / Set Acknowledgement Delay Upper Limit
*+/$+NU*
*+/$+NU*
2 Scan a numeric value for data from these bar codes:
*0*
*0*
*2*
*2*
132
*1*
*1*
*3*
*3*
Trakker Antares 2400 Family System Manual