Trakker Antares 2400 Family System Manual: Chapter 6 - Configuration Command Reference, pages 183 to 192
Pages 183 to 192 of 362, from Trakker Antares 2400 Family System Manual
The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2410, Intermec 2415, Intermec 2435 and Intermec 2475
Page 183
Chapter 6 - Configuration Command Reference
Or: To disable the configuration commands via serial port for each serial port, scan these bar codes: COM1 Commands Via Serial Port Disabled
*$+YT1.0*
COM2 Commands Via Serial Port Disabled
*$+YT2.0*
*$+YT1.0*
$+YT2.0*
COM3 Commands Via Serial Port Disabled
COM4 Commands Via Serial Port Disabled
*$+YT3.0* *$+YT3.0*
*$+YT4.0*
*$+YT4.0*
Or: To set the configuration commands via serial port to enabled with TMF for each serial port, scan these bar codes: COM1 Commands Via Serial Port Enabled With TMF
*$+YT1.1*
COM2 Commands Via Serial Port Enabled With TMF
*$+YT2.1*
*$+YT1.1*
$+YT2.1*
COM3 Commands Via Serial Port Enabled With TMF
COM4 Commands Via Serial Port Enabled With TMF
*$+YT3.1* *$+YT3.1*
*$+YT4.1*
*$+YT4.1*
Controller Connect Check Receive Timer Terminals: 2415, 2425, 2435, 2455, 2475, and 2485/6. Description: During periods of inactivity on the terminal, the terminal still sends messages to the Intermec Gateway or DCS 30X to check the RF or Ethernet connection. If no message is received within the time set for the Controller Connect Check Receive Timer, the terminal is no longer connected to the Intermec Gateway or DCS 30X and the Network Connect status light (or the Connect LED or the Connect icon) blinks. The timer countdown resets each time a valid message is received. Power Management Tip: Intermec strongly recommends that you use the optimum setting of 60 seconds. Syntax: NPdata Acceptable values for data are any number from 1 to 3600 seconds (60 minutes). Default:
60 seconds
Menu System: Main Menu > Configuration Menu > Communications Menu > Advanced Network
Trakker Antares 2400 Family System Manual
163
Page 184
Chapter 6 - Configuration Command Reference
Bar Codes: To set the default controller connect check receive timer, scan this bar code: Default Controller Connect Check Receive Timer
*$+NP60* *$+NP60*
Or: To set the controller connect check receive timer: 1 Scan this bar code: Enter Accumulate Mode / Set Controller Connect Check Receive Timer
*+/$+NP*
*+/$+NP*
2 Scan a numeric value for data from these bar codes:
*0*
*0*
*2*
*2*
*4*
*4*
*6*
*6*
*8*
*8*
*1*
*1*
*3*
*3*
*5*
*5*
*7*
*7*
*9*
*9*
3 Scan this bar code: Exit Accumulate Mode
*-/*
*-/*
Controller Connect Check Send Timer Terminals: 2415, 2425, 2435, 2455, 2475, and 2485/6. Description: During periods of inactivity on the terminal, the terminal still sends messages to the Intermec Gateway or DCS 30X to check the RF or Ethernet connection. The terminal sends a message at the time interval set for the Controller Connect Check Send Timer. The timer countdown resets each time a valid message is sent or received.
164
Trakker Antares 2400 Family System Manual
Page 185
Chapter 6 - Configuration Command Reference
Power Management Tip: Intermec strongly recommends that you use the optimum setting of 35 seconds. Syntax: NQdata Acceptable values for data are any number from 1 to 3600 seconds (60 minutes). Default:
35 seconds
Menu System: Main Menu > Configuration Menu > Communications Menu > Advanced Network Bar Codes: To set the default controller connect check send timer, scan this bar code: Default Controller Connect Check Send Timer
*$+NQ35* *$+NQ35*
Or: To set the controller connect check send timer: 1 Scan this bar code: Enter Accumulate Mode / Set Controller Connect Check Send Timer
*+/$+NQ*
*+/$+NQ*
2 Scan a numeric value for data from these bar codes:
*0*
*0*
*2*
*1*
*1*
*3*
*2*
*3*
*4*
*5*
*4*
*6*
*6*
*8*
*8*
*5*
*7*
*7*
*9*
*9*
3 Scan this bar code: Exit Accumulate Mode
*-/*
*-/*
Trakker Antares 2400 Family System Manual
165
Page 186
Chapter 6 - Configuration Command Reference
Controller IP Address Terminals: 2415, 2425, 2435, 2455, 2461, 2475, 2480/1 with the Ethernet option, and 2485/6 using the UDP Plus network. Description: Defines the IP address assigned to the Intermec Gateway or DCS 30X in your network. An IP address is a unique network level address you assign to each device in a TCP/IP network. The controller IP address you set on the terminal must match the address that is set on the Intermec Gateway or DCS 30X. If you plan to enable DHCP (Dynamic Host Configuration Protocol), you can set the controller IP address to any valid IP address. The terminal will locate and reset the IP address after you enable DHCP. If you use the default controller IP address of 0.0.0.0, controller DHCP is used to obtain a non-zero controller IP address, even if DHCP (Controller) is not enabled. For help, see “DHCP (Controller)” on page 173. Syntax: NCn.n.n.n where each n address segment is a number from 0 to 255. The controller IP address field consists of four separate numbers, each separated by a period. Note: The RF or Ethernet network cannot be activated if the first address segment in the IP address is set to 0, 127, or a number greater than 223. Default:
0.0.0.0
Menu System: Main Menu > Configuration Menu > Communications Menu > Primary Network Bar Codes: To set the default controller IP address, scan this bar code: Default Controller IP Address
*$+NC0.0.0.0* *$+NC0.0.0.0*
Or: To set the controller IP address: 1 Scan this bar code: Enter Accumulate Mode / Set Controller IP Address
*+/$+NC*
*+/$+NC*
2 Scan a numeric value from 0 to 255 to set an n field of the controller IP address from these bar codes.
*0*
*0*
166
*1*
*1*
Trakker Antares 2400 Family System Manual
Page 187
Chapter 6 - Configuration Command Reference
*2*
*2*
*4*
*4*
*6*
*6*
*8*
*8*
*3*
*3*
*5*
*5*
*7*
*7*
*9*
*9*
3 Scan this bar code: . (Period)
*.*
*.*
4 Repeat Steps 2 and 3 to set the next three numbers in the controller IP address field. After you scan the last address segment, go to Step 5. Do not scan the period after the last address segment. 5 Scan this bar code: Exit Accumulate Mode
*-/*
*-/*
Data Bits Terminals: All Trakker Antares terminals. Description: Sets the number of data bits the terminal uses when communicating with another device (i.e., host computer) through the serial port. You can configure the data bits for the Binary and Configurable communications protocols. For more information, see the networking chapter in your user’s manual. Syntax: YIn.data where n is: 1 2 3 4
COM1 serial port COM2 serial port (246X and 248X terminals only) COM3 serial port (242X terminals only) COM4 serial port (242X, 2455, and 248X terminals only)
Acceptable values for data are: 7 8 Default:
7 data bits 8 data bits
7 data bits
Trakker Antares 2400 Family System Manual
167
Page 188
Chapter 6 - Configuration Command Reference
Menu System: Main Menu > Configuration Menu > Communications Menu > Serial Port Bar Codes: Scan one of these bar codes: 7 Data Bits for COM1
*$+YI1.7*
8 Data Bits for COM1
*$+YI1.8*
*$+YI1.7*
*$+YI1.8*
7 Data Bits for COM2
8 Data Bits for COM2
*$+YI2.7*
*$+YI2.8*
*$+YI2.7*
*$+YI2.8*
7 Data Bits for COM3
8 Data Bits for COM3
*$+YI3.7*
*$+YI3.8*
*$+YI3.7*
*$+YI3.8*
7 Data Bits for COM4
8 Data Bits for COM4
*$+YI4.7* *$+YI4.7*
*$+YI4.8*
*$+YI4.8*
Decode Security Terminals: All Trakker Antares terminals. Description: Defines the security level to use when decoding bar codes. When you select a lower decode security level, the terminal can decode bar codes with poorer print quality. Note: You should only use the low parameter as a temporary solution until you can improve the bar code label print quality. Syntax: CSdata Acceptable values for data are: 0 1 2 Default:
Low Moderate High
Moderate
Menu System: Main Menu > Configuration Menu > Terminal Menu > Scanner Bar Codes: Scan one of these bar codes: Low Decode Security
*$+CS0* *$+CS0*
168
Moderate Decode Security
*$+CS1*
*$+CS1*
Trakker Antares 2400 Family System Manual
Page 189
Chapter 6 - Configuration Command Reference High Decode Security
*$+CS2* *$+CS2*
Default Router Terminals: 2415, 2425, 2435, 2455, 2461, 2475, 2480/1 with the Ethernet option, and 2485/6 using the TCP/IP or UDP Plus network. Description: Defines the IP address assigned to the default router in your RF or Ethernet network. The router provides a software and hardware connection between two or more subnetworks that permits traffic to be routed from one subnetwork to another on the basis of the intended destinations of that traffic. When the Intermec Gateway, DCS 30X, or host (TCP/IP network) is on a different subnetwork than the terminal, you need to set the IP address assigned to the default router. The terminal uses the router address to send packets across the network to the Intermec Gateway, DCS 30X, controller, or host. The default of 0.0.0.0 means there is no default router. Syntax: NXn.n.n.n where each n address segment is a number from 0 to 255. The default router address field consists of four separate numbers, each separated by a period. Note: The RF or Ethernet network cannot be activated if the first address segment in the IP address is set to 0, 127, or a number greater than 223. Default:
0.0.0.0
Menu System: Main Menu > Configuration Menu > Communications Menu > Advanced Network Bar Codes: To set the default value for the default router, scan this bar code: No Default Router
*$+NX0.0.0.0* *$+NX0.0.0.0*
Or: To set the default router address: 1 Scan this bar code: Enter Accumulate Mode / Set Default Router
*+/$+NX*
*+/$+NX*
Trakker Antares 2400 Family System Manual
169
Page 190
Chapter 6 - Configuration Command Reference
2 Scan a numeric value from 0 to 255 to set an n field of the default router address from these bar codes.
*0*
*1*
*0*
*1*
*2*
*3*
*2*
*3*
*4*
*5*
*4*
*5*
*6*
*7*
*6*
*7*
*8*
*9*
*8*
*9*
3 Scan this bar code: . (Period)
*.*
*.*
4 Repeat Steps 2 and 3 to set the next three numbers in the default router address field. After you scan the last address segment, go to Step 5. Do not scan the period after the last address segment. 5 Scan this bar code: Exit Accumulate Mode
*-/*
*-/*
Device Management Terminals: 2415, 2425, 2435, 2455, 2475, 2480/1 with the Ethernet option, and 2485/6 using the TCP/IP or UDP Plus network. Description: Enables or disables device management on the terminal. When Device Management is enabled, the Avalanche Enabler on the terminal tries to locate an Avalanche Agent. For more information about Wavelink Avalanche, see “Managing Your Terminals with Wavelink Avalanche” on page 38. Syntax: UDdata Acceptable values for data are: 0 1
170
Disable Device Management Enable Device Management
Trakker Antares 2400 Family System Manual
Page 191
Chapter 6 - Configuration Command Reference
Default:
Enabled
Menu System: Main Menu > Configuration Menu > Device Management > Use Device Mgmt Bar Codes: To enable or disable Device Management: 1 Scan one of these bar codes to disable or enable Device Management: Disable Device Management
*$+UD0*
*$+UD0*
Enable DHCP Device Management
*$+UD1*
*$+UD1*
2 To save the changes in flash memory, scan this bar code: Save Configuration in Flash Memory
*.+1*
*.+1*
Device Manager IP Address Terminals: 2415, 2425, 2435, 2455, 2475, 2480/1 with the Ethernet option, and 2485/6 using the TCP/IP or UDP Plus network. Description: Defines the IP address assigned to the Avalanche Agent in your Wavelink Avalanche client management system. The Avalanche Enabler uses this IP address to locate the Agent. The Agent does not need to be on the same subnet as the terminal. Once a network profile is downloaded, the terminal will use the Agent IP address defined by the network profile instead of the one set by this command. You can set the Device Manager IP Address to 0.0.0.0 to allow the Enabler to search for any Agent on the local subnet. Syntax: UEn.n.n.n where each n address segment is a number from 0 to 255. The Device Manager IP Address field consists of four separate numbers, each separated by a period. Default:
0.0.0.0 (no Avalanche Agent IP address)
Menu System: Main Menu > Configuration Menu > Device Management > Manager IP
Trakker Antares 2400 Family System Manual
171
Page 192
Chapter 6 - Configuration Command Reference
Bar Codes: To set the default Device Manager IP Address, scan this bar code: Default Device Manager IP Address
*$+UE0.0.0.0* *$+UE0.0.0.0*
Or: To set the Device Manager IP Address: 1 Scan this bar code: Enter Accumulate Mode / Set Device Manager IP Address
*+/$+UE*
*+/$+UE*
2 Scan a numeric value from 0 to 255 to set an n field of the Device Manager IP Address from these bar codes.
*0*
*0*
*2*
*2*
*4*
*4*
*6*
*6*
*8*
*8*
*1*
*1*
*3*
*3*
*5*
*5*
*7*
*7*
*9*
*9*
3 Scan this bar code: . (Period)
*.*
*.*
4 Repeat Steps 2 and 3 to set the next three numbers in the Device Manager IP Address field. After you scan the last address segment, go to Step 5. Do not scan the period after the last address segment. 5 Scan this bar code: Exit Accumulate Mode
*-/*
*-/*
172
Trakker Antares 2400 Family System Manual