Page 97

nugget

Sample Screen:

39 AGaramond Chapter 4 - Running Diagnostics

CLEAR TASK PROFILES Hardware Config Operating system task profiles counters have been cleared.

[Esc] Exit 24XXS058.eps

Definition: When you select the Clear Task Profiles option, the terminal clears the %Time field on the Task Status screen. It also resets all counters that are used to calculate the Application Efficiency screen.

Code Verify Purpose: A programmer or application developer can use this diagnostic to determine if the terminal’s firmware has been overwritten. Where Available: System Diagnostics menu Sample Screen:

CODE VERIFY TEST

Passed

[Esc] Exit

CODE VERIFY TEST

FAILED beeper DB400 csp D4100 scanner CE200

[Esc] Exit 24XXS059.eps

Definition: If this diagnostic passes, “Passed” appears on the screen. If this diagnostic fails, then the name of the firmware driver that failed and its address appears on the screen.

Display Test Purpose: Use the Display Test to make sure that every pixel on the terminal screen is working correctly. For example, you may want to test the screen if you do not see complete characters on the screen. Where Available: Hardware Diagnostics menu

Trakker Antares 2400 Family System Manual

77

Page 98

Chapter 4 - Running Diagnostics

Sample Screen:

nugget

DISPLAY

39 AGaramond

TEST

[Enter] Next [Esc] Exit pattern

24XXS062.eps

Definition: Press ; to display each of the four patterns. After 5 seconds, the entire screen is filled with the current test pattern. Press ; to display the next pattern. The first two patterns appear as a shaded pattern and turn off every other pixel. The third pattern turns on every pixel and appears as a black square. The fourth pattern turns off every pixel and appears as a clear square. If any of these patterns are not displayed correctly, you may have a problem with the LCD. For help, contact your local Intermec service representative.

Error Logger Purpose: If you suspect that your terminal has a problem, you can use the Error Logger to help diagnose the problem. The terminal posts an entry to the Error Logger whenever it detects an unexpected condition. Each entry does not necessarily indicate a problem. For example, if an application is not waiting for keyboard input and you press enough keys to fill the keyboard queue, the terminal will post a queue full error to the Error Logger. For a list of possible errors, see “Error Numbers and Messages” on page 87. Note: The Error Logger is not intended to be an application debugging tool. Where Available: Software Diagnostics menu

78

Trakker Antares 2400 Family System Manual

Page 99

nugget

Sample Screen:

39 AGaramond Chapter 4 - Running Diagnostics

ERROR LOGGER Current Time:231912 Time Err# Address 024401 0003 90000548 024359 0002 90000548 024358 0001 90000548

[Enter] Next [Esc] Exit screen

24XXS063.eps

Definition: The Error Logger screen shows the last 30 errors in three columns: • The first column displays the time in HHMMSS format. • The second column displays the error number. To learn which error message is associated with the error number, see “Error Numbers and Messages” on page 87. • The third column displays the internal firmware address, which helps identify why the error occurred. Press ; to see the next screen of errors.

Font Test Purpose: You can use this diagnostic to identify which double-byte font, if any, you have loaded on your terminal. Where Available: Software Diagnostics menu Sample Screen:

FONT TEST

FONT TEST

DB Font 13

No Double Byte Font Loaded

[Esc] Exit

[Esc] Exit 24XXS064.eps

Definition: If you ordered the optional 4MB flash memory for your terminal, you can use the Trakker Antares Font Loader to download a double-byte font set to the terminal. See your local Intermec sales representative for information about ordering double-byte fonts. Use this table to match the font number with the double-byte font that is loaded on your terminal.

Trakker Antares 2400 Family System Manual

79

Page 100

Chapter 4 - Running Diagnostics nugget

39 AGaramond

Double-Byte Font and Font Number Font Number 1

Double-Byte Font Simplified Chinese, VT

File Name 24DBCSCT.fon

2

Japanese, 5250

24DBCSJL.fon

4

Korean, VT

24DBCSKT.fon

5

Korean, 5250

24DBCSKL.fon

8

Big 5 Chinese, VT

24DBCSTT.fon

9

Japanese, VT

24DBCSJT.fon

11

Big 5 Chinese, 5250

24DBCSTL.fon

13

Simplified Chinese, 5250

24DBCSCL.fon

Hardware Configuration Purpose: If you are discussing a problem with Intermec, you can use the Hardware Configuration screen to tell the Intermec representative the exact version of hardware that was installed on the terminal at the Intermec factory. Where Available: Hardware Diagnostics menu Sample Screen:

HARDWARE

CONFIG

HARDWARE

Country USA

Code: (80,01)

PCMCIA PCMCIA

Display Display Display

Type: Rev.: Cont:

0 0 32

PCB

Keypad Keypad Keypad

Type : Rev. : Table:

0 0 0

[Enter] Next [Esc] Exit screen

Type: Rev.:

Rev.

CONFIG 2 1

:

1

ID

:

2485

Serial # X123456789

:

Product

[Enter] Next [Esc] Exit screen 24XXS065.eps

Definition: Press ; to display the next screen of hardware information. If you are having a specific problem with one system, such as the radio, note the hardware versions on the terminal before contacting your local Intermec service representative. The country code information on the Hardware Configuration screen is only valid when the radio (Network Activate command) is enabled. If the radio is disabled, the country code information is not valid. For help, see “Network Activate” on page 210.

Keypad Table Purpose: Intermec service personnel use this diagnostic to identify the number of the keypad table that you have loaded on your terminal.

80

Trakker Antares 2400 Family System Manual

Page 101

nugget

39 AGaramond Chapter 4 - Running Diagnostics

Where Available: Software Diagnostics menu Sample Screen:

KEYPAD TABLE

Keypad Table 0x02

[Esc] Exit 24XXS067.eps

Definition: This table matches the hex code on the screen with a description of the keypad table that is loaded on your terminal. Keypad Table Hex Code Description Hex 0x00

Description Terminal Emulation, 242X

Hex 0x12

Description European (AT), 2455

Hex 0x0B

Description Portuguese QWERTY, 2475, 248X

0x01

Programmable, 242X

0x13

Compatible 1, VMT and LI (AT), 246X

0x0C

Terminal emulation with backspace key, 242X

0x02

English QWERTY (XT), 2475, 248X

0x14

Programmable/internationa l, 55-key, 241X

0x0D

Programmable with backspace key, 242X

0x03

5250 alphanumeric (XT), 2475, 248X

0x15

Terminal emulation, 55key, 241X

0x0E

English ABCD (AT), 2455

0x04

3270 alphanumeric (XT), 2475, 248X

0x16

Terminal emulation, 39key, 243X

0x0F

5250 alphanumeric (AT), 2455

0x05

VT/ANSI alphanumeric (XT), 2475, 248X

0x17

Not used

0x1A

International, 37-key, 241X

0x06

Function key with large numeric, 37-key, 248X

0x18

Programmable, 37-key, 241X

0x1B

Programmable, function key with large numeric, 241X

0x07

French AZERTY, 2475, 248X

0x19

Terminal emulation, 37key, 241X

0x1C

Terminal emulation, function key with large numeric, 241X

0x08

Italian QWERTY, 2475, 248X

0x20

Terminal emulation, 57key, 243X

0x1D

International, function key with large numeric, 241X

0x09

Spanish QWERTY, 2475, 248X

0x21

Programmable, 39-key, 243X

0x1E

Programmable, 57-key, 243X

0x10

3270 alphanumeric (AT), 2455

0x22

European, 39-key, 243X

0x1F

European, 57-key, 243X

0x11

VT/ANSI alphanumeric (AT), 2455

0x0A

German QWERTY, 2475, 248X

Trakker Antares 2400 Family System Manual

81

Page 102

Chapter 4 - Running Diagnostics nugget

39 AGaramond

Keypad Test Purpose: An application programmer can use the Keypad Test screen to quickly find the hexadecimal key code value, the decimal key code value, and the scan code for any key on the keypad. You can also use the test to make sure the keypad is operating correctly. Where Available: Hardware Diagnostics menu Sample Screen: Key 'a' 'b' 'c' 'd' 'e' 'f' 'g' 'h' 'i' 'j' 'k' 'l' 'm'

KEYPAD

TEST

Hex 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D

Dec 97 98 99 100 101 102 103 104 105 106 107 108 109

[Esc]

Scan 1E 30 2E 20 12 21 22 23 17 24 25 26 32

Exit 24XXS068.eps

Definition: Press any key or key combination on the keypad to display the hexadecimal, decimal, and scan code value of the key. When you press d, the terminal pauses for a few seconds to display the values before you exit the screen. For a complete list of key codes, see the “Trakker Antares Terminal Font Set” on page 290 or refer to the Trakker Antares Application Development Tools System Manual (P/N 064433).

Malloc Application Information Purpose: A programmer or application developer can use the Malloc Application Information screen to see how memory is allocated and used by the current application. Where Available: Choose the Malloc Info Menu from the System Diagnostics menu. Sample Screen:

APPLICATION Total Free: 0000064656 Largest Free: 0000064656 Fragments: 00001 Allocated Blocks: 00001

OK 24XXS070.eps

Definition: The screen displays the memory allocation used by the application. You can view the total free memory, largest block of free memory, number of

82

Trakker Antares 2400 Family System Manual

Page 103

nugget

39 AGaramond Chapter 4 - Running Diagnostics memory fragments, and total number of allocated blocks of memory. You can use this diagnostic screen to troubleshoot a memory leak where the application is mallocing memory, but not freeing memory.

Malloc Firmware Information Purpose: A programmer or application developer can use the Malloc Firmware Information screen to see how memory is allocated and used in the terminal firmware. The firmware includes the operating environment, firmware, drivers, and TRAKKER Antares 2400 Menu System. Where Available: Choose the Malloc Info Menu from the System Diagnostics menu. Sample Screen:

FIRMWARE Total Free: 0000007040 Largest Free: 0000006768 Fragments: 00002 Allocated Blocks: 00015

OK 24XXS071.eps

Definition: The screen displays the memory allocation for the terminal firmware. You can view the total free memory, the largest block of free memory, the number of memory fragments, and the total number of allocated blocks of memory.

Radio Test Purpose: Use the Radio Test screen to verify that you have a working radio. This diagnostic only applies to RF terminals. Where Available: Hardware Diagnostics menu Sample Screen:

RADIO TEST

TESTING Test: PASSED

[Esc] Exit 24XXS073.eps

Trakker Antares 2400 Family System Manual

83

Page 104

Chapter 4 - Running Diagnostics nugget

39 AGaramond

Definition: Before you start the test, make sure the radio (Network Activate command) is enabled. If the radio is disabled, the test results on the Radio Test screen are not valid. For help, see “Network Activate” on page 210. Press ; to start the radio test. The results of the test appear on the screen once the test is complete. If SUCCESS or PASSED appear, the radio is working correctly. If FAILED appears, note the error number. You may have a problem with the radio inside the RF terminal. For help, contact your local Intermec service representative. If the Radio Test fails, stop using the terminal. Contact your local Intermec service representative. Attention: Si le test Radio échoue, veuillez ne plus utiliser le terminal. Contactez le représentant du service clientèle Intermec de votre région.

Scanner Test Purpose: Use the Scanner Test to make sure the integrated laser scanner and scan button or the tethered laser scanner and scanner trigger are operating correctly. Where Available: Hardware Diagnostics menu Sample Screen:

SCANNER TEST Press ENTER to turn the laser on for 3 seconds. Or, scan a label to test the laser.

[Enter] Execute test [Esc] Exit 24XXS074.eps

Definition: To start the test, press ;. If the laser scanner turns on, the scanner is working correctly. If the laser scanner does not turn on, you may have a problem with the scanner. If you are using a tethered scanner, make sure you are using one that is supported on the terminal. Note: If you are using a 241X with an integrated linear imager, it takes about 2 seconds for the laser to turn on after you press \. If you are using a 241X with an integrated PDF417 scanner, the laser briefly flashes and then turns on about 2 seconds after you press \.

84

Trakker Antares 2400 Family System Manual

Page 105

nugget

39 AGaramond Chapter 4 - Running Diagnostics

If the laser scanner did turn on in the first test, try scanning a bar code label. If the laser scanner turns on, the scan button or scanner trigger is working correctly. If the laser scanner does not turn on, you may have a problem with the scan button or scanner trigger. For help with scanner problems, contact your local Intermec service representative.

Serial Port Test Purpose: Use the Serial Port Test screen to test or troubleshoot serial communications between the terminal and the host computer or serial device. To run this diagnostic test, you must connect the terminal to a host or serial loopback connector. Where Available: System Diagnostics menu Sample Screen:

SERIAL PORT TEST Select Com. Port: 1,4, Esc : 1 F1:Port Select :1 F2:Keypad Echo : ON F3:Scanner Echo: ON F4:Continous TX: OFF

Input: Echo: [Esc] Exit 24XXS076.eps

Definition: Press 1 to test the RS-232 serial communications port. The screen displays the function key options you can use in this diagnostic screen. Serial Port Test Function Key Options Function Key F1

Description Selects the serial port.

F2

Toggles the keypad echo on and off. If you turn the keypad echo on, characters you type on the keypad are displayed on the bottom line of the screen and transmitted to the host.

F3

Toggles the scanner echo on and off. If you turn the scanner echo on, the bar code label you scan is displayed on the bottom line of the screen and transmitted to the host.

F4

Toggles the Continuous Transmit mode on and off. If you turn continuous transmit on, the terminal continuously sends out a string of characters.

Esc

Exits the Serial Port Test diagnostic screen.

On the host, you use an RS-232 serial communications package to receive data from the terminal. To test serial communications, enter or scan data on the terminal. If the terminal is communicating with the host, you will see the data. If there is a problem, check the serial port parameters and Trakker Antares 2400 Family System Manual

85

Page 106

Chapter 4 - Running Diagnostics nugget

39 AGaramond make sure they match the host settings. For help with serial port errors, see the Troubleshooting chapter in your user’s manual, or contact your local Intermec service representative.

Subsystem Versions Purpose: If you are discussing a problem with Intermec, you can use the Subsystem Versions screen to tell the Intermec representative the exact version of firmware subsystems loaded on the terminal. Radio driver, network, or radio subsystem information only applies to RF terminals. Where Available: System Diagnostics menu Sample Screen:

SUBSYSTEM

VERSIONS

Name UDP+ L 80211 DS Decodes Scanner Term Serv XMODEM Serial Port Keypad Label Task Menu System

[Enter] Next [Esc] Exit

Version 031000 031000 031000 031000 031000 031000 031000 031000 031000 031000 screen 24XXS077.eps

Definition: Press ; to display the next screen of subsystem information. If you are having a specific problem with one system, note the version loaded on the terminal before contacting your local Intermec service representative.

Task Status Purpose: A programmer can use the Task Status screens to view the task name, stack, and the percentage of time a task has been running. You can also use the Task Status screen to determine the type of RF network protocol, TCP/IP, UDP Plus, or WTP, loaded on the terminal. Where Available: Software Diagnostics menu Sample Screen:

TASK STATUS

TASK STATUS SLOT 0: 1: 2: 3: 4: 5: 6: 7: 8: 9: 10: 11:

TASK NAME ----:---SM UDP+ ----:---Label Task Serial Port Menu System PM APP ID ----:-------:----

%TIME 00.5% 00.1% 00.7% --.-% 00.0% 00.0% 02.0% 00.0% 00.0% 95.6% --.-% --.-%

[Enter] Next screen [Esc] Exit

SLOT 0: 1: 2: 3: 4: 5: 6: 7: 8: 9: 10: 11:

STACK ----:---1B8F:0010 1A48:0010 ----:---19F6:0010 19B5:0010 1944:0010 18E3:0010 18C2:0010 18A1:0010 ----:-------:----

UNUSED ---0381 0010 ---029C 0339 03A5 0394 011C 0110 -------

[Enter] Next screen [Esc] Exit 24XXS078.eps

86

Trakker Antares 2400 Family System Manual